• 제목/요약/키워드: Xe

검색결과 530건 처리시간 0.031초

유도결합형 제논 플라즈마의 전자온도, 밀도 특성 (Properties of Electron Temperature and Density in Inductively Coupled Plasma of Xenon)

  • 허인성;양종경;이종찬;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.41-45
    • /
    • 2005
  • In this paper, parameters of electron temperature and density for the mercury-free lighting-source were measured to diagnosis and analyze in Xe based inductively coupled plasma(ICP). In results at several dependences of 20~100 mTorr Xenon pressure, 50~200W RF power and horizontal distribution were especially mentioned. When Xe pressure was 20mTorr and RF power was 200W, the electron temperature and density were respectively 3.58eV and $3.56{\times}10^{12}cm^{-3}$. The key parameters of Xe based ICP depended on Xe pressure more than RF power that could be verified. A high electron temperature and low electron density with a suitable Xe pressure are indispensible parameters for Xe based ICP lighting-source.

  • PDF

오픈소스 기반의 실습용 SIC/XE 컴퓨터 시뮬레이터의 구현 (Implementation of Open Source-based SIC/XE Computer Simulator for Educational Laboratory)

  • 김주현;김현아;문봉교
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2017년도 추계학술발표대회
    • /
    • pp.2-5
    • /
    • 2017
  • 기존의 어셈블러는 시각적으로 불편하고 사용자 편의를 위한 기능을 제공하지 않으며 최신의 컴퓨터와의 호환성 문제가 있었다. 이러한 문제점들의 해결책으로 나온 SIC/XE 어셈블러 시뮬레이터 오픈 소스를 GitHub에서 클론하여 분석하고 테스트하였다. 본 논문에서는 오픈 소스 SIC/XE 어셈블러 시뮬레이터의 다양한 오류를 분석하고 이를 수정하였다. 또한 리터럴 테이블, 심볼 테이블, 목적코드 및 오류 메시지의 시각화를 통해 기존의 SIC/XE 어셈블러 시뮬레이터를 개선시켜 사용자 편의를 높인 학습용 SIC/XE 어셈블러 시뮬레이터를 구현하였다.

A Comparison Study of the Effect of Adding Ar or Kr Gas into the Conventional Gas Mixtures in a Matrix Type PDP

  • Khorami, Alireza;Ghanbari, Shirin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.748-751
    • /
    • 2009
  • This paper provides a novel scheme to enhance luminous efficiency within Plasma Display Panels (PDPs). The He-Xe or Ne-Xe mixtures are mainly used in conventional PDP cells, where their discharge characteristics exemplify different behavior. Significantly, the excitation efficiency in He-Xe is lower than that of the Ne-Xe mixture. This paper demonstrates that by adding a small quantity of Ar or Kr gas in Ne-Xe mixture increases cell efficiency, while for the He-Xe mixtures their cell efficiency is reduced.

  • PDF

AC PDP에서 Kr-Ne-Xe 혼합가스의 방전 특성 연구 (A research of the discharge characteristics in Kr-Ne-Xe gas mixture of AC PDP)

  • 박현동;이돈규;조성용;이해준;이호준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1574-1575
    • /
    • 2006
  • 보통의 AC PDP에서는 Ne, Xe 혼합가스를 사용한다. Xe %가 높아짐에 따라 PDP의 효율은 올라가지만 그와 함께 최초의 방전을 일으키는 방전 개시 전압 또한 올라간다. 이러한 이유로 실제 PDP에서 무한정 Xe %를 올릴 수는 없다. 그래서 우리는 Xe gas보다 원자번호가 낮은 불활성기체인 Kr gas를 첨가시킴으로써 동일한 효율에서 방전개시전압이 낮은 최적의 3원 가스 조성비를 찾아보았다.

  • PDF

유도결합형 제논 플라즈마의 전자온도, 전자밀도 특성 (Properties of Electron Temperature and Electron Density in Inductively Coupled Xenon Plasma)

  • 허인성;최기승;이종찬;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2418-2420
    • /
    • 2005
  • In this paper, parameters of electron temperature and density for the mercury-free lighting-source were measured to diagnosis and analyze in Xe based inductively coupled plasma(ICP). In results at several dependences of $20{\sim}100mTorr$ Xenon pressure, $50{\sim}200W$ RF power and horizontal distribution were especially mentioned. When Xe pressure was 20mTorr and RF power was 200W, the electron temperature and density were respectively 3.58eV and $3.56{\times}10^{12}cm^{-3}$. The key parameters of Xe based ICP depended on Xe pressure more than RF power that could be verified. A high electron temperature and low electron density with a suitable Xe pressure are indispensible parameters for Xe based ICP lighting-source.

  • PDF

몬테 칼로 전산코드 MCNPX를 이용한 I-123 생산량 예측 (Prediction of 123I production using the monte Carlo code MCNPX)

  • 유재준;김계홍;김병일;이동훈
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 춘계학술대회
    • /
    • pp.816-818
    • /
    • 2014
  • 갑상선암 진단 방사성의약품인 $^{123}I$ 생산을 목적으로 한 가스타겟챔버를 개발하고 MCNPX를 이용해 30MeV 빔에너지 가 가스타겟챔버에 어떻게 들어가는지와 들어갔을 경우의 $^{124}Xe$와 핵반응은 어떻게 발생하는지를 모델링하였다. 빔에너지 가 확산되어 가스타겟챔버 내경에 맞아 에너지 손실이 생긴다. 그것은 즉 손실된 에너지가 열로 바뀜으로 타겟챔버가 변형이 일어나기 않게 냉각수를 이용한다. 쿨링시스템도 타겟챔버를 효율적으로 냉각하기위해 냉각수라인을 나선형으로 설계하였다. KIRAMS에서 보유하고 있는 사이크로트론 C30을 이용하여 30MeV 에너지에 100A 빔을 조사해 $^{124}Xe(p,2n)$, $^{124}Xe(p,n)$, $^{124}Xe(p,pn)$ 각각의 핵반응이 일어나는걸 알 수 있었고 생산량을 예측 할 수 있었다.

  • PDF

Comparison of the fluid simulation with experimental data of excited Xe species density in PDP cell

  • Yang, Sung-Soo;Ko, Sang-Woo;Kim, Hyun-Chul;Mukherjee, Sudeshna;Lee, Jae-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.739-742
    • /
    • 2003
  • We have compared 2-D and 3-D fluid simulation results of alternating current plasma display panel (AC-PDP) cell with experimentally measured two kinds of excited Xe species $Xe^{\ast}(^{3}P_{1})$ and $Xe^{\ast}(^{3}P_{2})$ characteristics. Although direct experimental access and diagnostics of the discharge in a PDP cell is problematic due to the small cell size, some of experimental technologies have made it possible to diagnose the behavior of excited Xe species [1, 2]. The simulation shows the similar characteristics to the experimental results in the excited Xe species density distribution and the number of excited Xe atoms in anode and cathode region. In certain cases, we obtained the arch-shaped discharge path between two sustain electrodes due to the additional pulse applied to address electrode analogous to experiment. This long path discharge induced higher luminous and discharge efficiency compared to the standard case.

  • PDF

ICP 광원 시스템의 Ne:Xe, Ne:Ar 혼합가스의 단일탐침법을 이용한 플라즈마 진단 (Plasma Diagnosis of Ne:Xe, Ne:Ar Mixed Gases by Single Langmuir Probe in Inductively Coupled Plasma Light Source System)

  • 최용성;이우기;;이경섭;이상헌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 영호남 합동 학술대회 및 춘계학술대회 논문집 센서 박막 기술교육
    • /
    • pp.91-95
    • /
    • 2006
  • In whole world consciousness of environment maintenance have increased very quickly for the end of the 20th century. To use and disuse toxic substances have been controled at the field of industry. Also the field of lighting source belong to environmental control. And in the future the control will be strong. In radiational mechanism of fluorescence lamp mechanism is the worst environmental problem. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem root. In the mercury free lighting source system the Xe gas lamp is one type. And the Ne:Xe mixing gas lamp improvements firing voltage of Xe gas lamp. Purpose and subject of this study are understand, efficiency, ideal of Ne:Xe plasma which mercury free lamp. Before ICP was designed, basic parameters of plasma, which are electron temperature and electron density, were measured and calculated by Langmuir probe data. Property of electron temperature and electron density were confirmed by changing ratio of Ne:Xe.

  • PDF

Kr과 Xe 원자기체의 전자수송계수의 해석 (The Analysis of Electron Transport Coefficients in Kr and Xe Atom Gas)

  • 전병훈
    • 조명전기설비학회논문지
    • /
    • 제22권8호
    • /
    • pp.104-108
    • /
    • 2008
  • 플라즈마 현상의 정량적 이해를 위해서는 원자나 분자기체가 가지고 있는 정확한 전자충돌단면적과 그 전자수송 계수의 값을 필요로 한다. 본 연구에서 사용하고 있는 Kr과 Xe 원자기체는 PDP와 무전각램프 등 다양한 산업 응용분야에 이용되고 있다. 따라서 2항 근사 볼츠만 해석에 의해 기체압력 1[torr]의 조건에 $0.001{\sim}500$[Td]의 광범위한 E/N에서 순수 Kr과 Xe 원자기체의 전자이동속도 W, 종 횡축확산계수 $ND_L$$ND_T$, 전리계수 $\alpha$/N의 전자수송 계수를 계산하고 물성 해석하였다.

ICP 광원 시스템의 Ne:Xe Ne:Ar 혼합가스의 전자온도 및 전자밀도의 특성 연구 (The Electron temperature and Density properties of Mixing gas in ICP Lighting system(Ne:Xe, Ne:Ar))

  • 최기승;이종찬;최용성;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2424-2426
    • /
    • 2005
  • In whole world consciousness of environment maintenance have increased very quickly for he end of the 20th century. To use and disuse toxic substances have been controled at the field of industry. Also the field of lighting source belong to environmental control. And in the future the control will be strong. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem root. In the mercury free lighting source system the Xe gas lamp is one type. And the Ne:Xe and Ne:Ar mixing gas lamp improvements firing voltage of Xe gas lamp. Purpose and subject of this study are understand, efficiency, ideal of Ne:Xe and Ne:Ar plasma which mercury free lamp. Before ICP was designed, basic parameters of plasma, which are electron temperature and electron density, were measured and calculated by langmuir probe data. Property of electron temperature and electron density were confirmed by changing ratio of Ne:Xe and Ne:Ar.

  • PDF