• 제목/요약/키워드: X8

Search Result 8,976, Processing Time 0.04 seconds

A Study on the Separation of X- and Y- Spermatozoa in Farm Animals (가축에 있어서 X-정자와 Y-정자의 분류에 관한 연구)

  • 고대환;박흠대;정길생
    • Korean Journal of Animal Reproduction
    • /
    • v.3 no.1
    • /
    • pp.41-47
    • /
    • 1979
  • This experiment was carried out to clarify the methods of the F-body test in human and the B-body test in buil and hog. The effect of pH and albumin concentration on the migration of X- and Y- sperm was also investigated. The results obtained were summarized as follows: 1. In the human semen, the frequency of sperm in which an F-body is visible was different by the fluorochrome. Namely, in case of quinacrine mustard, the F-body frequency was 48.8∼43.4 percent (average 49.6%), and in case of quinacrine dihydrochloride, that was 40.7∼50.8 percent (average 42.0%). 2. The frequency of a, pp.rance of B-body was 43.4${\pm}$1.3 percent in bull semen, and 45.5${\pm}$0.7 percent in hog semen. 3. A, pp.arance of B-body in bovine semen was increased due to duration of time after washing till 12 hours. 4. Separation of X- and Y- spermatozoa using diluents with different hydrogen ion concentration was impossible. 5. A, pp.arance of B-body separated in medium with 6, 10 and 20% ovalbumin was 51.1${\pm}$2.4, 50.6${\pm}$2.5 and 58.2${\pm}$3.0 percent, respectively, and those values were significiantly higher (p<0.01) than corresponding control values.

  • PDF

Spreading Pattern of Epidurally-Administered Contrast Media in Rabbits (토끼에서 경막외강으로 투여한 조영제의 분포양상)

  • Lee, Sang-Chul
    • The Korean Journal of Pain
    • /
    • v.10 no.2
    • /
    • pp.231-234
    • /
    • 1997
  • Background: The aim of this study was to examine the precise spreading pattern of contrast media in small increments in rabbits. Following pentobarbital anesthesia, the epidural puncture was done surgically with a blunt hook. Methods: The tip of epidural catheter was located at the mid-portion of T7 and T12, in the T7 group (n=7) and T12 group (n=8), respectively. Injection of the contrast media was started at 0.1 mL/kg and increased by 0.1 mL/kg up to a maximum of 0.6, mL/kg, under fluoroscopy. Results: In both groups, the extent of spread increased continuously as a Starling resistor with increasing injected volume(T7 group: $y=4.0+41.8x-28.1x^2$, T12 group: $y=0.2+57.7x-43.5x^2$) the total spread of contrast media was similar. The contrast media spread equally, both rostral and caudal, from catheter tip in T7 group; media spread approximately twice as far rostral as compared to caudal in T12 group (P<0.05). Conclusions: In rabbits, the position of epidural catheter tip should be positioned 2~3 segments below the aimed segment in lower thoracic or lumbar region, whereas in mid-thoracic region it should be positioned close to the level of aimed segment. Rabbits have relatively small epidural space therefore, the volume of injectant should be carefully determined with the suggested equations of this study.

  • PDF

Pyroelectric Infrared Microsensors Made by Micromachining Technology (강유전체 박막과 마이크로 가공 기술을 이용한 초전형 적외선 센서의 제작)

  • Choi, J.R.;Lee, D.H.;Nam, H.J.;Cho, S.M.;Lee, J.H.;Kim, K.Y.;Kim, S.T.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.66-68
    • /
    • 1994
  • 강유전체 박막과 마이크로 가공기술을 이용하여 초전형 적외선 센서를 제작하였다. 초전형 적외선 센서는 $Pb_{1-x}La_xTi_{1-x/4}O_3$ (x=0.05) (PLT) 강유전체 박막 커패시터를 RF 마그네트론 스퍼터링 방식으로 백금 전극이 증착된 MgO 기판상에 결정 성장시킨 구조를 갖고 있다. 스퍼터링된 PLT 바닥은 높은 c-축 결정 구조를 가지므로 센서로 사용하기 위한 poling 처리 과정이 필요하다. 이는 적외선 이미지 센서를 구현함에 있어서 수율 향상에 필수적인 요소이다. 마이크로 가공 기술을 사용하여 센서의 열용량을 극소화 함으로서 센서의 효율을 최대화하였다. 제작된 센서의 상부에 폴리이미드를 코팅하고 MgO 기판을 선택적으로 식각하여 코팅된 폴리이미드가 강유전체 박막 커패시터를 지지하고 있는 구조를 구현하였다. 이렇게 제작된 센서의 감도는 상온에서 $8.5{\times}10^8cm{\cdot}{\sqrt}{Hz/W}$로 측정되었으며 이는 마이크로 가공 기술을 사공하지 않은 경우보다 약 100 때의 감도 향상을 가져왔다.

  • PDF

Microstructure and Magnetic Properties of Nanocomposite Sm2Fe15Ga2Cx/α-Fe Permanent Magnets

  • Cheng, Zhao-hua
    • Journal of Magnetics
    • /
    • v.8 no.1
    • /
    • pp.18-23
    • /
    • 2003
  • In our previous work, microstructure and magnetic properties of two-phase exchange-coupled $Sm_2Fe_{15}Ga_2C_{x}$/$\alpha$-Fe nanocomposites have been investigated by means of x-ray diffraction, transmission electron microscopy and magnetization measurement. It was found the exchange coupling between the magnetically hard phase $Sm_2Fe_{15}Ga_2C_{x}$ and the magnetically soft one ${\alpha}$-Fe results in an enhancement of the remanence. The sizes of crystallites of both phases are, however much larger than the Block domain-wall width of the magnetically hard phase. This microstructure gives rise to a concave demagnetization curve and consequently reduces the maximum energy Product. In order to improve their magnetic properties, a few Percent of Zr, which may be effective to refine the microstructure through rapid quenching, was introduced into the nanocomposites. The addition of Zr was found to improve the magnetic properties significantly, Under optimum heat-treatment conditions, the remanence, coercivity and maximum energy Product increase from 0.65 T, 0.48 T and 50 kJ/$m^{3}$ for the Zr-free sample to 0.72 T, 0.77 T and 71.6 kJ/$m^{3}$ for the 1 at.% Zr-containing one, respectively, The improvements of magnetic properties are due to the refinement of microstructure by the addition of Zr.

The Multipactor Test results on the X Band filter of Space Qualification Model appropriated for the Geostationary Satellite considering for space environments (우주환경을 고려한 정지궤도위성에 적합한 X대역 필터의 멀티팩터 시험 결과 연구)

  • Park, Jong-hee;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.65-68
    • /
    • 2017
  • In this paper, a multipactor test for the space qualification model of the X-band dual-mode high-power channel filter for high-speed data transmission of geostationary satellite observation payloads was conducted and compared with the 8 dB margin required for design. It was confirmed that analytically required margins were met through testing and that satisfactory test results were obtained. The design and test of the multipactor are tested according to the ECSS standard. Based on this, it is suggested that if the margin of design is sufficiently secured, it can be used in the development of the filter for space qualification model without any test.

  • PDF

The effect of $Co_{3}O_{4}$ substitution on properties of Ni-Zn Ferrite (Ni-Zn 페라이트 물성의 $Co_{3}O_{4}$ 치환효과)

  • An, Yong-Woon;Kim, Jong-Ryung;Oh, Young-Woo;Kim, Hyun-Sik;Lee, Hae-Yun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.92-95
    • /
    • 2003
  • 전력선 통신용 LC 공진필터에 사용되는 Ni-Zn 페라이트를 제조하기 위해 $Ni_{0.8}Zn_{0.2}Fe_{2}O_{4}$를 기본조성으로 첨가제 $Bi_{2}O_{3}$, CaO와 x (co mol 비)를 변화시켜 전자기적 특성을 조사하였다. $Bi_{2}O_{3}$ CaO가 첨가됨으로써 균일한 입자성장과 입계에 고저항층이 형성되어 주파수 손실이 감소하였으며, $Ni_{0.8-x}Zn_{0.2}Co_{x}Fe_{2}O_{\delta}$의 기본조성에 Co의 함량을 증가시키면 x = 0.05에서 투자율 75, 공진주파수 20MHz의 특성을 나타내고 결정 입자 크기와 같은 구조적 특성에는 영향을 거의 미치지 않지만 전자기적 특성에는 영향을 미친다. 또한, $Ni_{0.75}Zn_{0.2}Co_{0.05}Fe_{2}O_{4.017}$ 조성의 페라이트 코어의 발열량은 큐리온도 이하에서 일어난다.

  • PDF

Synthesis and X-ray Crystal Structure of the Ethylenediammonium Monohydric Phosphate (Ethylenediammonium Monohydric Phosphate의 합성 및 X-선 결정구조)

  • Tae-Sun Chang;Chong-Hyeak Kim;Deug-Hee Cho;Dong-Koo Lee;Tianyou Song
    • Korean Journal of Crystallography
    • /
    • v.13 no.2
    • /
    • pp.96-100
    • /
    • 2002
  • The title compound, (H/sub 3/NCH/sub 2/CH/sub 2/NH/sub 3/)HPO/sub 4/ (Ⅰ), has been synthesized by hydrothermal technique for the first time and its novel structure analyzed by X-ray single crystallography. The compound (Ⅰ) crystallizes in the monoclinic system, P2/sub 1//c space group with a=10.209(1), b=7.891(1), c= 8.039(1) (equation omitted), β= 92.138(9)°, V=: 647.2(2) (equation omitted), Z=4, R/sub 1/=0.0295 and ωR/sub 2/=0.0811 for 1141 independent reflections. The compound (Ⅰ) is interconnected to give a three-dimensional network through hydrogen-bonding interactions.

Characterization of Metal/Cobalt Ferrite Magnetic Thin Films

  • Park, C.H.;Na, J.G.;Heo, N.H.;Lee, S.R.;Kim, J.;Park, K.
    • Journal of Magnetics
    • /
    • v.3 no.1
    • /
    • pp.31-35
    • /
    • 1998
  • Metal/cobalt ferrite composite thin films with the saturation magnetization (M_s$)of~580 emu/cm3 and the coercivity(Hc) of 1700 Oe were prepared by the reactive sputtering. With increasing substrate temperature, Ms of the thin films increased, while Hc of the thin films decrease. This sttributed to the precipitation of $Co_xFe_{1-x}(x {\appro}x0.62)$ metal phase in the thin films. The metal phase showed the BCC structure ($a_0$=2.89 $\AA$) and Im3m space group. Also, the cobalt ferrite phase was identified as$ CoFe_2O_4$ with a cubic structure ($a_0=8.39 $\AA$$) and a space group of Fd3m. For the higher cobalt content than the stoichiometric composition,$ Co_{37.8}Fe_{62.2}$, the thin films with high Ms and Hc could be obtained in the wide substrate temperature range (200-40$0^{\circ}C$).

  • PDF

A Novel Varactor Diodeless Push-Push VCO with Wide Tuning Range (바렉터 다이오드를 이용하지 않은 광대역 Push-Push 전압제어 발진기)

  • Lee Moon-Que;Moon Seong-Mo;Min Sangbo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.4 s.95
    • /
    • pp.345-350
    • /
    • 2005
  • An X-band push-push VCO for low cost applications is proposed. The designed push-push oscillator achieves a wide tuning range in the X-band by the collector bias tuning instead of extra varactor diodes. The measurement shows a wide tuning bandwidth of $900\;\cal{MHz}\;from\;10.9\;\cal{GHz}\;to\;11.8\;\cal{GHz}$ with a drain bias voltage varying from 4 to 9 V, excellent fudamental suppression of $-30\;\cal{dBc}$ and good phase noise of $-115\;\cal{dBc/Hz}\;@\;1\;\cal{MHz}$ offset.

Design of Voltage Controlled Oscillator for X-band Radar Using CSRR loaded microstrip line (마이크로스트립 종단형 CSRR구조를 이용한 X-band 레이다용 전압제어발진기의 설계)

  • Kim, Gue-Chol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.9
    • /
    • pp.1277-1283
    • /
    • 2013
  • In this paper, a novel voltage controlled oscillator(VCO) using CSRR loaded microstrip line for X-band RADAR is proposed. Using the microstrip line loaded CSRR inserted between the oscillator and buffer to the filter, the harmonic suppression has been improved. The measured results of the fabricated oscillator shows that its oscillation frequencies are from 9.28 to 9.39GHz according to the tuning voltage 0~10V, its output power level are about 16.6dBm at 9.35GHz. Compared with VCO using the conventional VCO, VCO using CSRR loaded microstirp, the harmonic suppression characteristic has been improved in 10.4dB