• Title/Summary/Keyword: X8

Search Result 8,976, Processing Time 0.04 seconds

Development of Salted Semi-dried Common Gray Mullet Mugil cephalus using Response Surface Methodology (Response Surface Methodology를 이용한 숭어(Mugil cephalus) 반염건품의 개발)

  • Park, Kwon Hyun;Heu, Min Soo;Kim, Jin-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.48 no.6
    • /
    • pp.839-848
    • /
    • 2015
  • This study examined the optimal salting drying method and processing conditions (salt concentration, curing time, dry temperature, and drying time) for preparing salted semi-dried common gray mullet (SSD-CGM) Mugil cephalus based on the moisture content, salinity, and overall acceptance using response surface methodology (RSM). The moisture content, salinity, and overall acceptance of SSD-CGM prepared with different salting methods revealed that dry salting was the optimal salting method for preparing high-quality SSD-CGM. The optimal drying method for preparing high-quality SSD-CGM based on the drying velocity and sensory color was hot air-blast drying. The results of the RSM program indicated that the optimal independent variables ($X_1$, salt concentration; $X_2$, curing time; $X_3$, dry temperature; $X_4$, drying time) based on the dependent variables ($Y_1$, moisture content; $Y_2$, salinity; $Y_3$, overall acceptance) for high-quality SSD-CGM were 5.6% for $X_1$, 2.7 h for $X_2$, $47.0^{\circ}C$ for $X_3$, and 8.5 h for $X_4$ for uncoded values. The predicted values of $Y_1$, $Y_2$, and $Y_3$ for SSD-CGM prepared under optimal conditions were 54.4%, 4.2%, and 6.3, respectively, while the experimental values were $55.2{\pm}1.0%$, $4.1{\pm}0.3%$ and $6.7{\pm}0.8$. The actual and predicted values did not differ.

Three Dimensional Volume Reconstruction of an Object from X-ray Iamges using Uniform and Simultaneous ART (USART 방법에 의한 X선 영상으로부터의 삼차원 물체의 형상 복원)

  • Roh, Young-Jun;Cho, Hyung-Suck;Kim, Hyeong-Cheol;Kim, Jong-Hyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.1
    • /
    • pp.21-27
    • /
    • 2002
  • Inspection and shape measurement of three-dimensional objects are widely needed in industries for quality monitoring and control. A number of visual or optical technologies have been successfully applied to measure three-dimensional surfaces. However, those conventional visual or optical methods have inherent shortcomings such as occlusion and variant surface reflection. X-ray vision system can be a good solution to these conventional problems, since we can extract the volume information including both the surface geometry and the inner structure of any objects. In the x-ray system, the surface condition of an object, whether it is lambertian or specular, does not affect the inherent characteristics of its x-ray images. In this paper, we propose a three-dimensional x-ray imaging method to reconstruct a three dimensional structure of an object out of two dimensional x-ray image sets. To achieve this by the proposed method, two or more x-ray images projected from different views are needed. Once these images are acquired, the simultaneous algebraic reconstruction technique(SART) is usually utilized. Since the existing SART algorithms have several shortcomings such as low performance in convergence and different convergence within the reconstruction volume of interest, an advanced SART algorithm named as USART(uniform SART) is proposed to avoid such shortcomings and improve the reconstruction performance. Because, each voxel within the volume is equally weighted to update instantaneous value of its internal density, it can achieve uniform convergence property of the reconstructed volume. The algorithm is simulated on various shapes of objects such as a pyramid, a hemisphere and a BGA model. Based on simulation results the performance of the proposed method is compared with that of the conventional SART method.

The study for electric readout of X-ray signal using MOSFET (MOSFET를 이용한 X선 신호의 전기적 획득에 관한 연구)

  • Park, S.K.;Kang, Y.S.;Seo, J.H.;Park, J.K.;Nam, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.295-296
    • /
    • 1998
  • With xeroradiography appearance, DR (Digital Radiography) system have been studying for X-ray detection using photoreceptor. Also detection method for receptor charge change have been developing variably. We use photoreceptor material of a-Se(Amorphous Selenium) with high DQE, high SNR(Signal to Noise Ratio) and high transformation efficiency of X-ray signals into electrical signals. After a-Se receptor is uniformly charged by using Arc discharge, X-ray is exposed. Then a-Se receptor produce subtle charge variation and MOSFET detect charge variations. The detected signal pass A/D converter and signal processing by PC. As results, the initial voltage is 8V. It has wide dynamic range needed digital radiography system. In this study, we obtained data with changing kVp(tube potential voltage) and fixed 8mAs(tube current by exposure time) in X-ray system. However MOSFET detector for X-ray signal is not tested X-ray mAs variations. But if MOSFET detector is tested X-ray mAs variation and exactly calibrated multichannel is made and noise-reduction is done, suitable DR system readout method will be done.

  • PDF

Determination of the Equivalent Energy of a 6 MV X-ray Beam (6 MV X-선 빔의 등가에너지 결정)

  • Kim, Jong-Eon;Park, Byung-Do
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.591-596
    • /
    • 2016
  • The purpose of this study is to determine the equivalent energy of a 6MV X-ray beam in the experiment. The half-value layer (HVL) of lead for the 6 MV X-ray beam was measured using an ionization chamber. The linear attenuation coefficients were calculated with HVL. And, the mass attenuation coefficient was obtained by dividing the linear attenuation coefficient by the density of lead. The equivalent energy of mass attenuation coefficient was determined using the photon energy versus mass attenuation coefficient data of lead given by National Institute of Standards and Technology (NIST). In conclusion, the equivalent energy of the 6 MV X-ray beam was determined to be 1.61 MeV. This equivalent energy was determined to be about 30% lower than reported by Reft. The reason is presumed to be due to the presence of an air cavity between the lead attenuators.

Cloning and mulecular characterization of a nprX gene of bacillus subtilis NS15-4 encoding a neutral protease (Cloning and Molecular Characterization of a nprX gene of Bacillus subtilis NS15-4 Encoding a Neutral protease)

  • Lee, Seung-Hwan;Yoon, Ki-Hong;Nam, Hee-Sop;Oh, Tae-Kwang;Lee, Seog-Jae;Chae, Keon-Sang
    • Journal of Microbiology
    • /
    • v.34 no.1
    • /
    • pp.68-73
    • /
    • 1996
  • An nprX gene of Bacillus subtilis NS15-4 encoding a neutral protease was cloned and its molecular characteristics were analyzed. The complete nucleotide sequence indicated that there is an open reading frame (0RF) possibly encoding 521 amino acid polypeptide. The ORF used all codons expected two cysteine and a proline having a codon bias index (CBI) of 0.09 in Escherichia coli. There were homologous sequences to the consensus sequence of -35 and -10 regions of E. coli promoters and to a Shine-Dalgarno (SD) sequence located 25 bp downstream of a mojor transcription initiation site. Moreover, there were also five minor transcription initiation sites at 6. 7. 8. 14 and 15 nt downstream of the major site. Northern blot analysis revealed the presence of about 1.8 kb mRNA transcript in E. coli having the nprX gene. The nucleotide sequence was identified in GenBank to be a gene for a neutral protease of B. sutilis with six nucleotide difference in the ORF region. The flanking regions of the NprX ORF showed much more differences form those of other neutral protease genes except the nprE gene of B. subtilis, which has the most homology to the nprX gene, and of which the flanking regions were identical to those of the nprX gene.

  • PDF

Structural and Electrical Properties of Zn-Mn-O System Ceramics for the Application of Temperature Sensors (온도센서로의 응용을 위한 Zn-Mn-O계 세라믹의 구조적, 전기적 특성)

  • Kim, Kyeong-Min;Lee, Sung-Gap;Lee, Dong-Jin;Park, Mi-Ri;Kwon, Min-Soo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.8
    • /
    • pp.470-475
    • /
    • 2016
  • In this study, $Zn_xMn_{3-x}O_4$ (x=0.95~1.20) specimens were prepared by using a conventional mixed oxide method. All specimens were sintered in air at $1,200^{\circ}C$ for 12 h and cooled at a rate of $2^{\circ}C/min$ to $800^{\circ}C$, subsequently quenching to room temperature. We investigated the structural and electrical properties of $Zn_xMn_{3-x}O_4$ specimens with variation of ZnO amount for the application of NTC thermistors. As results of X-ray diffraction patterns, all specimens showed the formation of a complete solid solution with tetragonal spinel phase. And, the second phase was observed by the solubility limit of Zn ions in $x{\geq}1.10$ composition. The average grain size was increased from $2.72{\mu}m$ to $4.18{\mu}m$ with increasing the compositional ratio of Zn ion from x=0.95 to 1.20, respectively. $Zn_{1.10}Mn_{1.90}O_4$ specimen showed the minimum electrical resistance of $57.5k{\Omega}$ at room temperature and activation energy of 0.392 eV.

Usability Testing of OpenCourseWare(OCW) - Focusing on Students with Visual and Hearing Impairments - (오픈코스웨어(OCW)에 대한 장애학생 사용성 평가 - 시각 및 청각장애 대학생을 중심으로 -)

  • Son, Jiyoung;Yeom, Myungsook
    • Journal of Digital Contents Society
    • /
    • v.17 no.1
    • /
    • pp.43-50
    • /
    • 2016
  • The purpose of the study is to identify the usability of OpenCouresWare(OCW) from the perspective of students with visual and hearing impairments. Twelve college students with disabilities(8 visual and 4 hearing impairment) implemented usability testing. Two modules in both edX and KOCW were selected for testing. Students with disabilities implemented usability testing and then each individual case was analyzed through quantitative and qualitative methods. As results, the degree of general usability in both edX and KOCW indicated an average level and the degree of accessibility in edX module was evaluated higher than KOCW. Specifically, the module of edX was rated highly by students with hearing impairments and the usability level of KOCW module was highly appreciated by blind students.

Electronic Spectroscopy and Ligand Field Analysis of trans-[CrX2([15]aneN4)]+(X=F,CI) (trans-[CrX2([15]aneN4)]+(X=F,CI)의 전자분광학과 리간드장 해석)

  • Jong-Ha Choi;In-Gyung Oh;Sang Hak Lee;Yu Chul Park
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.2
    • /
    • pp.109-114
    • /
    • 2003
  • The electronic absorption spectra of trans-$[CrX_2([15]aneN_4)]ClO_4\;([15]aneN_4$=1,4,8,12-tetraazacyclopentadecane; X=F, Cl) complexes have been interpreted using the ligand field theory. An AOMX program is used to optimize the differences between the calculated and the observed positions for the spin-allowed transition bands. The crystal field theory(CFT) parameter is directly related to the angular overlap model(AOM), normalized spherical harmonic hamiltonians(NSH), and semiempirical parameters. The various ligand field parameters are discussed in terms of their chemical significances. According to the ligand field analysis, we can confirm that the fluoride ligand is a very strong ${\sigma}-$ and ${\pi}-$donor while the chloride has weak ${\sigma}-$ and ${\pi}-$donor properties toward chromium(III) ion.

The Development of Measuring Method of Coated Steel Corrosion in Mortar by Transient Electro-Magnetic(TEM) Method (과도전자탐사법에 의한 모르타르 중의 코팅 철근의 부식 측정 방법 개발)

  • Lee, Sang-Ho;Han, Jeong-Sub
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.2 s.32
    • /
    • pp.108-115
    • /
    • 1999
  • To study measurement of coated steel corrosion in mortar, a transient electro-magnetic(TEM) method was adapted. The sensors were made of enamelled wire with diameter of 0.25mm(transmitter), 0.1mm(receiver) and the secondary electro motive force(EMF) was measured with SIROTEMIII. The sensors configuration was used as in loop configuration. After coated steels were corroded by the salt spray during 3, 7, 15, 25days, they were embedded in mortar which were made from sand : cement : water ratio of 2 : 1 :0.5. To investigate coated steel corrosion in mortar, the sensors were used. ( sensorl - $T_x$ : $4{\Omega}$, $R_x$ : $10{\Omega}$, $3{times}3cm$, sensor2 - $T_x$ : $8{\Omega}$, $R_x$ : $10{\Omega}$, $3{times}3cm$, sensor3 - $T_x$ : $4{\Omega}$, $R_x$ : $10{\Omega}$, $6{times}6cm$, sensor4 - $T_x$ : $8{\Omega}$, $R_x$ : $10{\Omega}$, $6{times}6cm$). The obtained results showed that the secondary EMF was decreased with specimens of 3, 7days corroded coationg steel in mortar and then increased with specccimens of 15, 25days corroded one. And it was confirmed that measurement of coated steel corrosion in mortar by a transient electro-magnetic(TEM) method is possible.

  • PDF

Effect of Triton X-100 on Compactin Production from Penicillium citrinum

  • Park, Du-Bok;Cho, Ki-An;Cha, Wol-Suk;Ryu, Seong-Ryeol
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.3
    • /
    • pp.171-178
    • /
    • 2004
  • Glucose alone was found to be the most effective carbon source for producing compactin. An initial glucose concentration of 40 g/L gave the highest compactin concentration of 250mg/L. Among the various nitrogen sources, when 5g/L of pharmamedia and soybean meal as the sole nitrogen source were used, respectively, the compactin concentration was higher than 250mg/L. Especially, in the case of the mixture of 6 g/L of pharmamedia and 8 g/L of soybean meal, the compactin concentration was 400mg/L. To select the best surfactant for effective compactin production, various surfactants were investigated. When Triton X-100 was used, the maximum compactin concentration was 445mg/L. With the initial concentration ranging from 1.5 to 2.0 g/L, the compactin concentration was the highest at 465-450mg/L. The cell concentration was similar to that of the control without the addition of Triton X-100. On the other hand, when the above 4.0 g/L of Triton X-100 were used, the cell concentration decreased. Using the based results, the continuous fed-batch cultures by adding the Triton X-100 were carried out for 10 days in an air-lift bioreactor. When 1.5 g/L of Triton X-100 was added to the culture broth at 0, 4, and 8 days of culture, respectively, the compactin production was increased with the increase of culture time. The maximum compactin concentration after 10days of culture was 1,200mg/L, which was about 2.0-fold higher than that of the control without the addition of Triton X-100.