• Title/Summary/Keyword: X8

Search Result 8,977, Processing Time 0.036 seconds

Determination of the Optimum Rates of P and K Fertilizer Application for Tong-il Line Rices in Different Paddy Soils (통일계(統一系) 수도품종(水稻品種)에 대(対)한 답토양별(畓土壤別) 인산(燐酸) 및 가리시비적량(加里施肥適量))

  • Lee, Choon-Soo;Huh, Beom-Lyang;Ryu, In-Soo;Park, Chon-Suh;Ko, Mi-Suk
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.15 no.2
    • /
    • pp.101-109
    • /
    • 1982
  • An attempt to determine the optimum levels of P and K fertilizers application for Tong-il lines (indica${\times}$Japonica) was made with the data obtained from the farm fields during 1976 to 1979. The detailed interpretation to obtains relationships between fertilizer recommendation of P and K with their balance with Ca and Mg contents in soil were made using yield data obtained in 1977. The results were summarized as follows : 1. The optimum rates of P and K fertilizer application varied with the kinds of paddy soils showing the ranges of 6.6-11.4 kg/10a for P (as $P_2O_5$) and 7.0-11.3 kg/10a for K (as $K_2O$). The amounts of optimum fertilizers increased in the order of unmatured soil, normal soil, sandy soil, saline soil, poorly drained soil for P, and unmatured soil, poorly drained soil, sandy soil, normal soil, saline soil for K. 2. The yield increment at the optimum levels of P and K in comparison with no fertilizer application were 3,5-7.5% for P and 2.1-9.1% for K. The effectiveness of P was greatest in the unmatured soils and that of K was greatest in the poorly drained soils, and in the saline soil, that of P and K was relatively high. 3. According to relationship between relative yield index and soil testing value, the critical $P_2O_5$ contents which showed the yield response in soil were about 100 ppm for normal soil and 200ppm for sandy soil. That of exchangeable K/Ka+Mg ratio in soil were about 0.08 for normal paddy soil and over 0.08 for sandy soil, and those for poorly drained soils were not obtained in the ranged below 0.08. 4. The regression equations of fertilizer recommendation for different soils were obtained between the available $P_2O_5$ in soil or ratio of K to base including Ca and Mg in soil (x) and the amount (Y) of P and K fertilizers applied. The equations for phosphorus recommendation were Y=11.27C-0.048x for normal paddy soil and Y=13.383-0.061x for sandy soil, and those for potassium recommendation were Y=9.526-0.569x for normal paddy soil, Y=11.727-1.004x for sandy soil, and Y=12.574-0.558x for poorly drained soil, respectively.

  • PDF

The Chemistry and Origin of Amphibolitic Rocks in the Sobaegsan Metamorphic Belt and the Ogbang and Sangdong Tungsten Mine Areas, Korea (소백산변성대(小白山變成帶)와 옥방(玉房) 및 상동중석광상내(上東重石鑛床內)의 각섬석질암(角閃石質岩)의 지화학(地化學) 및 성인(成因)에 관(關)한 연구(硏究))

  • So, Chil-Sup;Kim, Sang-Myeong
    • Economic and Environmental Geology
    • /
    • v.8 no.3
    • /
    • pp.147-164
    • /
    • 1975
  • 19 amphibolite samples from the Precambrian Sobaegsan metamorphic belt including the Ogbang mine amphibolites were analyzed for 24 elements each, by wet chemical and emission spectroscopic methods. All the chemical data were evaluated by the methods outlined by Evans and Leake(1960) and Leake(1964) and by Shaw and Kudo(1965). The chemical similarity of all the studied rocks analyzed to basic igneous rocks is consistently indicated particularly by trace element abundance and variation trends. Petrography and oxidation ratios were also considered in attempting to determine the nature of the parent rocks. 3 analyses of W-bearing mafic metamorphic rocks from Sangdong area of the Ogcheon geosynclinal zone are also presented and discussed. Geochemical data for these latter rocks have been possibly derived from mafic tuffs deposited in an area of carbonate deposition.

  • PDF

Mechanical Property Evaluation of Dielectric Thin Films for Flexible Displays using Organic Nano-Support-Layer (유기 나노 보강층을 활용한 유연 디스플레이용 절연막의 기계적 물성 평가)

  • Oh, Seung Jin;Ma, Boo Soo;Yang, Chanhee;Song, Myoung;Kim, Taek-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.3
    • /
    • pp.33-38
    • /
    • 2021
  • Recently, rollable and foldable displays are attracting great attention in the flexible display market due to their excellent form factor. To predict and prevent the mechanical failure of the display panels, it is essential to accurately understand the mechanical properties of brittle SiNx thin films, which have been used as an insulating film in flexible displays. In this study, tensile properties of the ~130 nm- and ~320 nm-thick SiNx thin films were successfully measured by coating a ~190 nm-thick organic nano-support-layer (PMMA, PS, P3HT) on the fragile SiNx thin films and stretching the films as a bilayer state. Young's modulus values of the ~130 nm and ~320 nm SiNx thin films fabricated through the controlled chamber pressure and deposition power (A: 1250 mTorr, 450 W/B: 1000 mTorr, 600 W/C: 750 mTorr, 700 W) were calculated as A: 76.6±3.5, B: 85.8±4.6, C: 117.4±6.5 GPa and A: 100.1±12.9, B: 117.9±9.7, C: 159.6 GPa, respectively. As a result, Young's modulus of ~320 nm SiNx thin films fabricated through the same deposition condition increased compared to the ~130 nm SiNx thin films. The tensile testing method using the organic nano-support-layer was effective in the precise measurement of the mechanical properties of the brittle thin films. The method developed in this study can contribute to the robust design of the rollable and foldable displays by enabling quantitative measurement of mechanical properties of fragile thin films for flexible displays.

Early Clinical Experience in Aortic Valve Replacement Using On-X$^{circledR}$Prosthetic Heart Valve (On-X$^{circledR}$ 기계판막을 이용한 대동맥판 치환술의 조기 임상 경험)

  • 안병희;전준경;류상완;최용선;김병표;홍성범;박종춘;김상형
    • Journal of Chest Surgery
    • /
    • v.36 no.9
    • /
    • pp.651-658
    • /
    • 2003
  • Since the first implanted in September 1997, the use of On-X prosthetic heart valve has been increasing around in the world. This study was designed to assess the feasibility, safety, and the postoperative hemodynamics with this new valve in clinical setting. Material and Method: The current study was carried out on 52 patients undergoing aortic valve replacement with this prosthesis between April 1999 to August 2002 at Chonnam National University Hospital to evaluate the surgical results. 52% of the patients were male and the average age at implant was 50$\pm$13 years. The study followed the guidelines of the AATS/STS. Preoperatively, 32(61.5%) patients were in NYHA functional class III or IV and 2 patients had previous aortic valve surgery. Concomitant cardiac surgery was performed in 71.1%. The implanted valve sizes were 19 mm in 13 patients, 21 mm in 26, 23 mm in 10 and 25 mm in 3, respectively. Mean follow-up was 16.6$\pm$10.5 months (1∼39 months). Echocardiographic assessment was performed pre- and immediate postoperatively, as well as 3, 6, 12 months after surgery, evaluating pressure loss and regression of left ventricular hypertrophy. Result: Mean cardiopulmonary bypass time was 191$\pm$94.7 minutes with an aortic cross-clamp time of 142$\pm$51.7 minutes. There was no early and late mortality, Freedom from adverse events at 1 year in the study were as follows: thromboembolism, 95.6$\pm$6%; bleeding events, 90.2$\pm$4%; paravalvular leakage 92.3$\pm$4%; and overall valve-related morbidity at 1 year was 76.6$\pm$3%. There were no cases of valve thrombosis, prosthetic valve endocarditis and structural or non-structural failure. Left ventricular function at 12 months after surgery (EF=62.7$\pm$9.8%) revealed a statistically significant improvement compared to preoperative investigation (EF=55.8$\pm$15.9%, p=0.006). Left ventricular mass index was 247.3$\pm$122.3 g/$m^2$ on preoperative echocardiographic study, but regressed to 155.5$\pm$58.2 g/$m^2$ at postoperative 1 year (p=0.002). Over the follow-up period a further decrease of peak transvalvular gradients was observed in all patients: 62.5$\pm$38.0 mmHg on preoperative assessment, 18.2$\pm$6.8 mmHg at immediate postoperative period (p < 0.0001), 7.6$\pm$5.09 mmHg (p<0.0001) at 6 month, 18.0$\pm$10.8 mmHg (p<0.0001) at 1 year. Conclusion: The On-X prosthetic heart valve performs satisfactorily in the first 1 year period. Clinical outcome by examining NYHA functional classification revealed especially good results. Effective regression of left ventricular hypertrophy and statistically significant decrease of transvalvular gradient were observed over the first year, but longer-term follow-up of this patient group is needed to establish the expected rates for late valve-related events as well as the long-term clinical efficacy of this valve.

Optimization of the Addition of Garlic in Cheonggukjang using Response Surface Methodology (반응표면분석을 이용한 청국장 제조시 마늘의 첨가조건 최적화)

  • Hwang, Cho-Rong;Sim, Hye-Jin;Kim, Gyeong-Min;Cho, Kye-Man;Kim, Jeong-Hwan;Shin, Jung-Hye
    • Korean journal of food and cookery science
    • /
    • v.29 no.6
    • /
    • pp.661-669
    • /
    • 2013
  • This study was performed to determine the optimal composition of Cheonggukjang added with garlic. The experiment utilized a central composite design (CCD). The evaluation was carried out by means of response surface methodology (RSM), which included 18 experimental points with three independent variables : the content of the garlic (1.3~9.7%, $X_1$), the steaming time of garlic (0~15.1 min, $X_2$), and the fermentation time of Cheonggukjang (48.2~71.8 h, $X_3$). The viscous substance ($Y_1$), acidity ($Y_2$), amino-type nitrogen ($Y_3$), ${\gamma}$-GTP activity ($Y_4$) and ABTS radical scavenging activity ($Y_5$). were assessed in four replicates with five dependent variables. The maximum content of the viscous substance was 13.02% at 6.53% ($X_1$), 6.81 min ($X_2$) and 55.18 h ($X_3$). The acidity was increased when the fermentation time was longer, and the minimum acidity point was 0.50% at 7.75% ($X_1$), 3.42 min ($X_2$) and 58.60 h ($X_3$), respectively. The content of the amino-type nitrogen at the experimental range studied was was 80.58~158.82 mg%, and the stationary point was at saddle point. Using ridge analysis, the maximum point was 156.97 mg% at 6.21% ($X_1$), 14.85 min ($X_2$) and 58.04 h($X_3$). The optimum conditions of ${\gamma}$-GTP activity was 5.73% ($X_1$), 6.99 min ($X_2$) and 57.96 h($X_3$), respectively, at the maximum point was 353.66 mU/mL. The maximum point of ABTS radical scavenging activity was 76.43% at 3.78% ($X_1$), 14.28 min ($X_2$) and 57.99 h($X_3$) at the saddle point, when the garlic steaming time was longer.

Study on the Treesize Prediction Model : A case study of Zelkova serrata, Pinus strobus and Magnolia denudata (주요조경수목의 크기 예측 " 모델 "에 관한 연구 : 느티나무, 스트로브잣나무, 백목련을 대상으로)

  • 김남춘;최준수;문석기
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.16 no.1
    • /
    • pp.27-35
    • /
    • 1988
  • Size characteristics of three widely used landscape trees were analized to establish a methodology of size prediction as time Passes. Tree height, tree width, stem diameter(breast or surface), canopy length and tree age were measured directly and indirectly(by using photograph), and the data were analized by using regression analysis through PC-SAS. The results are summarized as follows : 1. Zelkova serrata MAKINO showed relatively slow growth rate and the tree form was changed as aged. Size predictions were available by using the regression equations listed below : Surface diameter = 0.8293 x AGE Tree height = 0.4109(0.8293 x AGE) - 0.0039(0.7273 x AGE)$^2$Tree width = 0.3240(0.8293 x AGE) - 0.0024(0.1293 x AGE)$^2$Canopy length = 0.1337(0.8293 x AGE) - 0.0020(0.7293 x AGE)$^2$2. Pinus strobus L. showed relatively fast growth rate and the tree form did not change much as aged. Size predictions were available by using the regression equations listed below. Breast diameter = 0.756 x AGE Tree height = 0.7695(0.756 x AGE) - 0.0164(0.75\ulcorner x AGE)$^2$Tree width = 0.4331(0.756 x AGE) - 0.0079(0.75\ulcorner x AGE)$^2$Canopy length = 0.1365(0.756 x AGE) - 0.0032(0.75f x AGE)$^2$ 3. In case of Magnolia denudata DESROUX, tree form was determined relatively earlier than the other two species. Si2e predictions were available by using the regression equations listed below : Surface diameter = 0.88 x AGE Tree height = 0.5412(0.88 x AGE) - 0.0110(0.88 x AGE)$^2$ Tree width = 0.3752(0.88 x AGE) - 7.0061(0.88 x AGE)$^2$Canopy length = 0.1110(0.88 x AGE) - 0.0022(0.88 x AGE)$^2$ This study aimed to find a way to predict size change of landscaping plants. This methodology will be applied to a wide range of landscape plants to provide practical data to landscape designers.

  • PDF

Electrochemical Characteristics of Nanotubular Ti-25Nb-xZr Ternary Alloys for Dental Implant Materials

  • Byeon, In-Seop;Park, Seon-Young;Choe, Han-Cheol
    • Journal of Korean Dental Science
    • /
    • v.10 no.1
    • /
    • pp.10-21
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the electrochemical characteristics of nanotubular Ti-25Nb-xZr ternary alloys for dental implant materials. Materials and Methods: Ti-25Nb-xZr alloys with different Zr contents (0, 3, 7, and 15 wt.%) were manufactured using commercially pure titanium (CP-Ti), niobium (Nb), and zirconium (Zr) (99.95 wt.% purity). The alloys were prepared by arc melting in argon (Ar) atmosphere. The Ti-25Nb-xZr alloys were homogenized in Ar atmosphere at $1,000^{\circ}C$ for 12 hours followed by quenching into ice water. The microstructure of the Ti-25Nb-xZr alloys was examined by a field emission scanning electron microscope. The phases in the alloys were identified by an X-ray diffractometer. The chemical composition of the nanotube-formed surfaces was determined by energy-dispersive X-ray spectroscopy. Self-organized $TiO_2$ was prepared by electrochemical oxidation of the samples in a $1.0M\;H_3PO_4+0.8wt.%$ NaF electrolyte. The anodization potential was 30 V and time was 1 hour by DC supplier. Surface wettability was evaluated for both the metallographically polished and nanotube-formed surfaces using a contact-angle goniometer. The corrosion properties of the specimens were investigated using a 0.9 wt.% aqueous solution of NaCl at $36^{\circ}C{\pm}5^{\circ}C$ using a potentiodynamic polarization test. Result: Needle-like structure of Ti-25Nb-xZr alloys was transform to equiaxed structure as Zr content increased. Nanotube formed on Ti-25Nb-xZr alloys show two sizes of nanotube structure. The diameters of the large tubes decreased and small tubes increased as Zr content increased. The lower contact angles for nanotube formed Ti-25NbxZr alloys surfaces showed compare to non-nanotube formed surface. The corrosion resistance of alloy increased as Zr content increased, and nanotube formed surface showed longer the passive regions compared to non-treatment surface. Conclusion: It is confirmed that corrosion resistance of alloy increased as Zr content increased, and nanotube formed surface has longer passive region compared to without treatment surface.

Corrosion Characteristics of TiN/Ti Multilayer Coated Ti-30Ta-xZr Alloy for Biomaterials (TiN/Ti 다층막 코팅된 생체용 Ti-30Ta-xZr 합금의 부식특성)

  • Kim, Y.U.;Cho, J.Y.;Choe, H.C.
    • Corrosion Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.162-169
    • /
    • 2009
  • Pure titanium and its alloys are drastically used in implant materials due to their excellent mechanical properties, high corrosion resistance and good biocompatibility. However, the widely used Ti-6Al-4V is found to release toxic ions (Al and V) into the body, leading to undesirable long-term effects. Ti-6Al-4V has much higher elastic modulus than cortical bone. Therefore, titanium alloys with low elastic modulus have been developed as biomaterials to minimize stress shielding. For this reason, Ti-30Ta-xZr alloy systems have been studied in this study. The Ti-30Ta containing Zr(5, 10 and 15 wt%) were 10 times melted to improve chemical homogeneity by using a vacuum furnace and then homogenized for 24 hrs at $1000^{\circ}C$. The specimens were cut and polished for corrosion test and Ti coating and then coated with TiN, respectively, by using DC magnetron sputtering method. The analyses of coated surface were carried out by field emission scanning electron microscope(FE-SEM). The electrochemical characteristics were examined using potentiodynamic (- 1500 mV~+ 2000 mV) and AC impedance spectroscopy(100 kHz~10 mHz) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The equiaxed structure was changed to needle-like structure with increasing Zr content. The surface defects and structures were covered with TiN/Ti coated layer. From the polarization behavior in 0.9% NaCl solution, The corrosion current density of Ti-30Ta-xZr alloys decreased as Zr content increased, whereas, the corrosion potential of Ti-30Ta-xZr alloys increased as Zr content increased. The corrosion resistance of TiN/Ti-coated Ti-30Ta-xZr alloys were higher than that of the TiN-coated Ti-30Ta-xZr alloys. From the AC impedance in 0.9% NaCl solution, polarization resistance($R_p$) value of TiN/Ti coated Ti-30Ta-xZr alloys showed higher than that of TiN-coated Ti-30Ta-xZr alloys.

Crystal Structures of Ni2$^{2+}$ - and Tl$^+$ - Exchanged Zeolite X, $Ni_{17}Tl_{58}Si_{100}Al_{92}O_{384} and Ni_{12}Tl_{68}Si_{100}Al_{92}O_{384}$

  • Song, Mi Gyeong;Yun, Bo Yeong;Kim, Yang
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.2
    • /
    • pp.164-170
    • /
    • 2001
  • The crystal structures of fully dehydrated Ni2+- and Tl+ -exchanged zeolite X (Ni17Tl58-X, and Ni12Tl68-X; X=Si100Al92O384) have been determined by single-crystal X-ray diffraction techniques in the cubic space group Fd3 at $21(1)^{\circ}C$ (a=24.380(4) $\AA$, 24.660(4) $\AA$, respectively). Their structures have been refined to the final error indices R1=0.037 and R2=0.043 with 485 reflections, and R1=0.039 and R2=0.040 with 306 reflections, respectively, for which I >36(I). In Ni17Tl58-X, 17 Ni2+ ions per unit cell were found at only two sites: 15 at site I at the center of the hexagonal prism (Ni-O=2.203(9) $\AA)$ and the remaining 2 at site II near single six-oxygen rings in the supercage (Ni-O=2.16(3) $\AA).$ Fifty-eight Tl+ ions were found at five crystallographic sites: 28 at site II (Tl-O=2.626(8) $\AA)$, 2 at site I' in the sodalite cavity near the hexagonal prism (Tl-O=2.85(1) $\AA)$, another 2 at site II' in the sodalite cavity (Tl-O=2.77(1) $\AA).$ The remaining 26 were found at two nonequivalent Ⅲ' sites with occupancies of 23 and 3. In Ni12Tl68-X, 12 Ni2+ ions per unit cell were found at two sites: 10 at site I (Ni-O=2.37(2) $\AA)$ and the remaining 2 at site II (Ni-O=2.13(2) $\AA).$ Sixty-eight Tl+ ions were found at five crystallographic sites: 28 at site II (Tl-O=2.63(1) $\AA)$, 12 at site I' (Tl-O=2.62(1) $\AA)$, 2 at site II' (Tl-O=3.01(2) $\AA)$, and the remaining 26 at two III' sites with occupancies of 23 and 3. It appears that Ni 2+ ions prefer to occupy site I and II, in that order. The large Tl+ ions occupy the remaining sites, I', II, II' and two different III' sites. In both crystals, only the Ni2+ ions at site II were reduced and migrated to the external surface of zeolite X when these crystals were treated with hydrogen gas.

Comparative Health Status of Rural Urban and Aged Perosons by Some Screening Tests (농촌 및 대도시의 노인건강진단에 있어서의 검사치 비교 고찰)

  • Han, In-Soo;Hong, Kwang-Sun;Park, Sun-Ju;Rim, Han-Jong
    • Journal of agricultural medicine and community health
    • /
    • v.14 no.1
    • /
    • pp.5-15
    • /
    • 1989
  • To compare the health status of rural and urban aged persons(over 65 years old) by an abnormality of a hematologic and some biochemical values as well as urinalysis and chest X-ray, following examinations were done on 8,756(male : 4,339: female 4,417) by hemoglobin, total cholesteol, GOT, and glucose, on 9,207(male: 4,467; female : 4.740) by urinalysis and on 9,148(male : 4,426: female : 4,722) by chest X-ray. The results are as follows: 1) The proportion of outlier of normal range of the GOT(over 40 unit) showed higher in rural aged persons(5.3%) than in urban aged(2.8%). There was no significant difference in both of urban and rual female, but the rural male(7.4 showed significantly higher than the urban male(3.9% ). 2) The proportion of abnormality of the total cholesterol value(over 260 mg/dl) was 7,0% in urban and 1.7% in rural aged persons. In the male, there was no significant difference in both urban(2.2%) and rural(1.4%), however the urban female(10.5%) showed significantly higher than the rural female(2.2%). 3) In the blood glucose level, the proportion of abnormality(over 120 mg/dl) showed 17.1% in urban and 19.3% in rural aged persons. The rural aged persons in both sexes(male : 18.1% : female : 20.7%) were relatively higher abnormality rates than those of the urban aged(male : 15. 3%: female : 18.4% ) respectively. 4) The proportion of abnormality of hemoglobin level(less than 12.0 g/dl in male: less than 11.0 g/dl in female) showed 7.1% in urban and 2.6%J in rural aged persons. The urban aged persons in both sexes(male : 8.3%: female 6.3%) were relatively higher abnormality rates than those of the rural aged(male : 3.0%: female : 2.2%) 5) In the urinalysis by urine stix(Korea Green Cross Co.), the positive rates of urine protein were 1.0% in urban and 0.5% in rural aged per-sons, and there was no any significant differences in both areas by sex. 6) The positive rates of urine glucose in urban aged persons(5.8'% : male : 7.3% : female : 4.7%). showed relatively higher than those of rural aged (3.4% : male : 3.9%: female : 2.8%). 7) The positive findings of pulmonary tuberculosis by indirect X-ray examination were observed in 7.7% of aged persons in both rural and urban areas respectively. However, the positive rates of male in both areas(urban : 12.8% ; rural : 10.0%) showed higher than those of female (urban 4.2% ; rural 5.0%).

  • PDF