• Title/Summary/Keyword: X8

Search Result 8,977, Processing Time 0.034 seconds

Studies on the Ecological Changes in the Plant Community of the Erosion Controlled Area at Yoju-Gun, Kyonggi-Do (사방시공지(砂防施工地) 식물사회(植物社會)의 생태학적(生態學的) 변화(變化)에 관(關)한 연구(硏究)(II) - 경기(京畿), 여주지역(驪州地域)을 중심(中心)으로 -)

  • Lee, Hyun Kyu
    • Journal of Korean Society of Forest Science
    • /
    • v.81 no.4
    • /
    • pp.303-309
    • /
    • 1992
  • This study eras carried out to investigate the ecological changes on the plant community at erosion controlled area in Yoju-gun, Kyonggi-do. The results of the study were as follows : 1. The depth of organic matters in the soil profile from 4 to 14 years was estimated to be $Y_{(cm)}=0.436X_{(yr)}-0.931$(r=0.978), and 02 layer was $Y_{(cm)}=0.339_{(yr)}-0.931$ (r=0.954). 2. On upper plant layer. Alnus spp. was decreased, on an average, 32% of relative coverage, 12.4% of relative density and 16.8% of relative frequency in each plot for 3 years, as this area was damaged by Agelastica coerulea Baly for 2-3 years. 3. On upper plant layer, relative coverage of Pinus spp. was increased after 6, 7 years in erosion controlled area and was taked the highest plant (more then 40%) from 10 to 14 years. 4. On lower plant layer, relative density of Quercus ssp. (these species has not been planted and sown on erosin controlling) was increased all the plot. 5. The increase of the whole crown projection area was estimated to be $Y_{(m^2)}=18.020X_{(yr)}+18.834$(r=0.954) 6. The biomass was estimated to be 14.88t/ha on elapsed 6 years, 22.84t/ha on 8 years, 35.08t/ha on 10 years, 47.80t/ha on 12 years, 58.13t/ha on 14 years.

  • PDF

Determination of Tb(III) in aqueous solution by fluorescence spectrometry (형광분광법에 의한 수용액 중의 Tb(III) 정량)

  • Lee, Sang Hak;Bae, Zun Ung;Chung, Hae Young;Choi, Sang Seob
    • Analytical Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.274-281
    • /
    • 1997
  • Methods to determine terbium(III) ion in aqueous solution by measuring the enhanced fluorescence intensity of terbium(III)-terephthalic acid(TPA) complex ion have been studied. The optimum analytical conditions for pH, excitation wavelength and concentration of TPA were found to be 6.0, 260nm and $4.0{\times}10^{-4}M$, respectively. The fluorescence intensity of the terbium(III) complex ion was further increased with addition of trioctylphosphine oxide (TOPO). In this case Triton X-100 was used to dissolve TOPO in aqueous solution. When TOPO was used, the optimum analytical conditions for pH, excitation wavelength, and concentrations of TPA, TOPO and Triton X-100 were found to be 4.5, 285nm. $4.0{\times}10^{-4}M$, $5.0{\times}10^{-5}M$, and 0.05%, respectively. Under the optimum experimental conditions, calibration curve for Tb(III) was linear over the range from $4.0{\times}10^{-8}M$ to $4.0{\times}10^{-5}M$ and the detection limit was $4.0{\times}10^{-8}M$. When TOPO was used, the concentration range of linear response, and the detection limit were $4.0{\times}10^{-9}M$ to $2.0{\times}10^{-6}M$, and $4.0{\times}10^{-9}M$, respectively. Effects of interferences from various cations for the determination of terbium(III) ion were also investigated.

  • PDF

Influence of Disease Severity of Bacterial Pustule Caused by Xanthomonas axonopodis pv. glycines on Soybean Yield (콩 불마름병 발생정도가 수량에 미치는 영향)

  • Hong, Sung-Jun;Kim, Yong-Ki;Jee, Hyeong-Jin;Shim, Chang-Ki;Kim, Min-Jeong;Park, Jong-Ho;Han, Eun-Jung;Lee, Bong-Choon
    • Research in Plant Disease
    • /
    • v.17 no.3
    • /
    • pp.317-325
    • /
    • 2011
  • Bacterial pustule of soybean (Glycine max) caused by Xanthomonas axonopodis pv. glycines is one of the most prevalent bacterial diseases of soybean in Korea, where it causes considerable yield loss. This study was carried out to develop yield prediction model for bacterial pustule by analyzing correlation between the percentage of diseased leaf area and yield. The severe disease incidence of soybean bacterial pustule caused yield losses by 19.8% in 2006 and 16.8% in 2007, respectively. Severity of bacterial pustule greatly affected on 100 seed weight and yield, but did not on stem length, number of branches per plant, number of pods per plant, number of seeds per plant. On the other hand, correlation coefficients between diseased leaf area and yield were $-0.93^*$('06) and $-0.77^*$('07), respectively. The regression equation obtained by analyzing correlation between the percentage of diseased leaf area and yield loss in 2006 and in 2007 was y = -3.2914x + 348.19($R^2$ = 0.8603) and y = -2.9671x + 302.08($R^2$ = 0.9411), respectively. These results will be helpful in estimating losses on a field-scale and thereby predicting the production of soybean.

Epidemiological Studies on Ascaris lumbricoides Reinfection in Rural Communities in Korea 1. The Relationship between Prevalence and Monthly Reinfection Rate (한국 농촌지역의 회충재감염에 대한 역학적 조사연구 I. 현재감염률과 월재감염률의 상관관계)

  • 채종일
    • Parasites, Hosts and Diseases
    • /
    • v.21 no.2
    • /
    • pp.135-141
    • /
    • 1983
  • The epidemiological relationship between the current prevalence and monthly reinfection rate of Ascaris lumbricoides was observed in rural communities in Korea by means of blanket mass chemotherapy and worm collection for measurement of the prevalence and reinfection rates. During the period from 1975 to 1980, a total of 4,466 inhabitants in 10 different localities were treated with 10 mg/kg of pyrantel pamoate and 2 days' whole stools were collected from 2,547 inhabitants. The stools were examined for the presence of expelled adult and/or young worms, which represent the prevalence and reinfection rates for past 2 months respectively. After then, the obtained rates were correlated each other applying the timeprevalence curve proposed by Hayashi. It was observed that the prevalence (overall worm positive rate) and worm burden per individual ranged by areas from 13. 6 to 72. 3% and 1.4~10. 2 respectively. The calculated monthly reinfection rates (X) (from young worm positive rates) according to areas were in the range, 2.6~16.2%, and clearly correlated with the current prevalence (Y) under the equation, $Y=1-(l-X)^{7.2}$ where 7.2 is time in month. The equation means that after one time mass chemotherapy the period needed to attain equilibrium of prevalence again would be about 7~8 months. And it is inferred that the majority of reinfected worms in human host turn over every 7~8 months.

  • PDF

Drug Sensitivity and Relapsed Period of Relapsed Pulmonary Tuberculous Patients registered in Some Public Health Offices, in Seoul (폐결핵 재발 환자의 약제 감수성과 재발 간격에 관한 단면 연구 - 서울시 일부 보건소 등록 환자를 중심으로)

  • Park, Hye-Sook;Ha, Eun-Hee;Wie, Cha-Hyung;Kang, Ji-Yong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.1 s.52
    • /
    • pp.67-78
    • /
    • 1996
  • The purpose of this study was examine the general characteristics of relapsed pulmonary tuberculous patients (i.e. age, sex, weight, occupation, previous forms of treatment, drug sensitivity, and the frequency of relapse) in order to improve future treatments of tuberculosis as well as to perpetuate health education. The data was obtained from the medical records of 186 relapsed pulmonary tuberculosis patients who were registered for treatment at various public health offices in Seoul during the year of 1994. The major findings obtained from the study were as follows; 1) The male to female ratio of relapsed pulmonary tuberculous patients was about 7:3, more specifically 23.7% of the men and 30.9% of the women were between 20 and 29 years of age. 2) Comparing initial less aggravated states to relapsed states, patients with minimal X-ray findings later proved moderately advanced X-ray findings. Furthermore, patients with negative sputum AFB findings later proved positive sputum AFB findings. 3) Of the 186 patients studied, 91.9% suffered, relapse and 8.1% suffered 2 or more relapses. Of the patients who suffered at least 1 relapse, 54.8% received short-term treatment, 26.9% received long-term treatment, and 18.3% received treatment of an unknown during their initial tuberculosis treatment periods. 4) fifty five point four percent of the patients had no reaction to the drug treatment(not available), 25.9% of the patients had sensitive reaction to the drug treatment, 18.7% of the patients had resistant reaction to the- drug treatment. Drug resistance was higher in patients that exhibited positive X-ray findings as well as in patients that exhibited positive sputum AFB findings. furthermore, patients receiving treatment of an unknown nature(35.5%) exhibited higher drug resistance than those receiving short-term treatment(13.6%) and long-term treatment(17.0%). 5) Of the 160 patients who suffered relapses, 8.8% suffered a relapse within 1 year after treatment and 91.2% suffered a relapse at least 1 year after treatment. Furthermore, our study showed that women, under 30, who received short-term treatment and encounterd complications during their primary treatment suffered relapses faster than any other groups studied. In addition, minimal X-ray findings and sputum AFB findings were not correlated to the time relapse occured. Therefore, the seater efforts are needed to prevent relapsed pulmonary tuberculosis.

  • PDF

Growth and Characterization of $CdGa_2Se_4$ Single Crystal Thin Films by Hot Wall Epitaxy (Hot Wall Epitaxy (HWE)에 의한 $CdGa_2Se_4$ 단결정 박막 성장과 특성)

  • Choi, S.P.;Hong, K.J.
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.328-337
    • /
    • 2001
  • The stochiometric mix of evaporating materials for the $CdGa_2Se_4$ single crystal thin films was prepared from horizontal furnace. To obtain the single crystal thin films, $CdGa_2Se_4$ mixed crystal was deposited on thoroughly etched semi-insulating GaAs(100) substrate by the Hot Wall Epitaxy (HWE) system. The source and substrate temperature were $630^{\circ}C$ and $420^{\circ}C$, respectively. The crystalline structure of single crystal thin films was investigated by the photoluminescence and double crystal X-ray diffraction (DCXD). The carrier density and mobility of $CdGa_2Se_4$ single crystal thin films measured from Hall effect by van der Pauw method are $8.27{\times}10^{17}cm^{-3}$, $345\;cm^2/V{\cdot}s$ at 293 K, respectively. From the photocurrent spectrum by illumination of perpendicular light on the c-axis of the $CuInSe_2$ single crystal thin film, we have found that the values of spin orbit splitting ${\Delta}So$ and the crystal field splitting ${\Delta}Cr$ were 106.5 meV and 418.9 meV at 10 K, respectively. From the photoluminescence measurement on $CdGa_2Se_4$ single crystal thin film, we observed free excition ($E_x$) existing only high quality crystal and neutral bound exiciton ($D^{\circ}$, X) having very strong peak intensity. Then, the full-width-at -half-maximum(FWHM) and binding energy of neutral donor bound excition were 8 meV and 13.7 meV, respectivity. By Haynes rule, an activation energy of impurity was 137 meV.

  • PDF

X-band Microstrip 4×4 Broadband Circularly Polarized Array Antenna Using Sequential Rotation Divider Structure (시퀀셜 로테이션 분배기 구조를 이용한 X-band 마이크로스트립 4×4 광대역 원형 편파 배열 안테나)

  • Kim, Jung-Han;Kim, Joong-Kwan;Kim, Yong-Jin;Lee, Hong-Min
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.2 s.117
    • /
    • pp.158-165
    • /
    • 2007
  • In this paper, the circularly polarized $4{\times}4$ array antenna is proposed for the X-band. A single antenna consists of square patch and unequal cross-aperture coupled feeding. The RHCP(Right Handed Circularly Polarization) is generated by unequal cross-aperture coupled feeding. By reducing space among elements of way antenna from 0.8 ${\lambda}_0$ to 0.45 ${\lambda}_0$, the mounting area of array antenna is miniaturized. The $2{\times}2$ array antenna is designed using sequential rotation feeding network. The good level of gain, axial ratio, and impedance bandwidth are achieved. The $4{\times}4$ array antenna is extended by ${\lambda}/4$ transformer and T-junction power divider. The simulated maximum radiation gain is 15.09 dBi at 10 GHz. The simulated 3 dB Axial Ratio bandwidth is from 9.05 to 10.4 GHz(13.5%). Also the measured impedance bandwidth($VSWR{\leq}2$) of manufactured $4{\times}4$ array antenna is from 8.45 to 11.84 GHz(33.9%). The measured maximum radiation gain is 11.10 dBi at 10 GHz. The measured 3 dB Axial Ratio bandwidth is from 9.42 to 10.47 GHz(10.5%).

Direct Conversion for the Production of 5-HMF from Cellulose over Immobilized Acidic Ionic Liquid Catalyst with Metal Chloride (고정화 산성 이온성 액체 촉매와 금속염화물 촉매를 이용한 셀룰로우스의 5-HMF로의 직접 전환 연구)

  • Park, Yong Beom;Choi, Jae Hyung;Lim, Han-Kwon;Woo, Hee-Chul
    • Clean Technology
    • /
    • v.20 no.2
    • /
    • pp.108-115
    • /
    • 2014
  • Various metal chlorides and acid catalysts in ionic liquid solvent were investigated to directly convert cellulose into 5-hydroxymethylfurfural (5-HMF). Metal chlorides containing Sn(II), Zn(II), Al(III), Fe(III), Cu(II), and Cr(III) were used and acidic ionic liquid immobilized on silica gel as an acid catalyst and commercial acid catalysts (sulfuric acid, chloric acid, Amberlyst-15,DOWEX50x8) were used for comparison studies. The acid strength and amount of acid catalysts were probed with Hammett indicator. The selectivity and yield of 5-HMF were determined with reaction temperature, reaction time and catalyst ratio. A catalyst containing $CrCl_3-6H_2O$ and $SiO_2-[ASBI]HSO_4$ showed the highest selectivity and it was found that this catalyst had higher activity than commercial solid acid catalysts such as Amberlyst-15 and DOWEX50x8. The selectivity of 5-HMF appeared to be mainly dependent on the acid strength and catalyst ratio, it was found that levulinic acid was produced from 5-HMF by rehydration.

Comparative Analysis by Batch Size when Diagnosing Pneumonia on Chest X-Ray Image using Xception Modeling (Xception 모델링을 이용한 흉부 X선 영상 폐렴(pneumonia) 진단 시 배치 사이즈별 비교 분석)

  • Kim, Ji-Yul;Ye, Soo-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.547-554
    • /
    • 2021
  • In order to quickly and accurately diagnose pneumonia on a chest X-ray image, different batch sizes of 4, 8, 16, and 32 were applied to the same Xception deep learning model, and modeling was performed 3 times, respectively. As a result of the performance evaluation of deep learning modeling, in the case of modeling to which batch size 32 was applied, the results of accuracy, loss function value, mean square error, and learning time per epoch showed the best results. And in the accuracy evaluation of the Test Metric, the modeling applied with batch size 8 showed the best results, and the precision evaluation showed excellent results in all batch sizes. In the recall evaluation, modeling applied with batch size 16 showed the best results, and for F1-score, modeling applied with batch size 16 showed the best results. And the AUC score evaluation was the same for all batch sizes. Based on these results, deep learning modeling with batch size 32 showed high accuracy, stable artificial neural network learning, and excellent speed. It is thought that accurate and rapid lesion detection will be possible if a batch size of 32 is applied in an automatic diagnosis study for feature extraction and classification of pneumonia in chest X-ray images using deep learning in the future.

Research on Surface Contamination Analysis of Radiology Examination Equipment in Medical Institutions (의료기관 내 영상의학 검사 장비의 표면 오염도 분석 연구)

  • Shin-Woo Lee;Da-eun Kim;Chae-won Mun;Gap-Jung Kim;Sang-Ha Kim;Hye-mi Park;Se-Jong Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.171-177
    • /
    • 2024
  • In this study, two general X-ray device, CT, and MRI inspection devices were selected from general hospitals in the Daejeon area and an experiment was conducted to predict the level of infection by measuring the surface contamination of the inspection devices at different times and to use it as basic data for infection prevention. As a result, the surface contamination level by time zone for general X-ray devices and MRI examination devices was in the order of 13H > 8H > 16H, and for CT examination devices, it was 13H > 16H > 8H, which appeared to be influenced by the number of tests. In addition, the surface contamination results for each part of the test device showed that the highest ATP contamination value was found on the stand bucky handle for the general X-ray device, the headrest for the CT examination device, and the operation switch for the MRI examination device, which was closely related to the number of contacts. As a result of comparing before and after disinfection, all devices showed a significant decrease after disinfection. Based on the results of the experiment, it is believed that it can be used as basic data to identify the level of contamination in radiology laboratories and prevent infectious diseases.