• Title/Summary/Keyword: X70

Search Result 1,787, Processing Time 0.028 seconds

Effects of Ni Addition on the Microstructures and Magnetic Properties of Fe70-xPd30Nix High-Temperature Ferromagnetic Shape Memory Alloys

  • Lin, Chien-Feng;Yang, Jin-Bin
    • Journal of Magnetics
    • /
    • v.17 no.2
    • /
    • pp.86-95
    • /
    • 2012
  • This study investigated the effects of adding a third alloying element, Ni, to create $Fe_{70-x}Pd_{30}Ni_x$ (x = 2, 4, 6, 8 at.% Ni) ferromagnetic shape memory alloys (FSMAs). The Ni replaced a portion of the Fe. The $Fe_{70-x}Pd_{30}Ni_x$ alloys were homogenized through hot and cold forging to gain a ~38% reduction in thickness, next they were solution-treated (ST) with annealing recrystallization at $1100^{\circ}C$ for 8 h and quenched in ice brine, and then aged at $500^{\circ}C$ for 100 h. Investigation of the microstructures and magnetostriction indicated that the greater Ni amount in the $Fe_{70-x}Pd_{30}Ni_x$ alloys reduced saturation magnetostriction at room temperature (RT). It was also observed that it was more difficult to generate annealed recrystallization. However, with greater Ni addition into the $Fe_{70-x}Pd_{30}Ni_x$ (x = 6, 8 at.% Ni) alloys, the $L1_0+L1_m$ twin phase decomposition into stoichiometric $L1_0+L1_m+{\alpha}_{bct}$ structures was suppressed after the $500^{\circ}C$/100 h aging treatment. The result was that the $Fe_{70-x}Pd_{30}Ni_x$ (x = 6, 8 at.% Ni) alloys maintained a high magnetostriction and magnetostrictive susceptibility (${\Delta}{\lambda}{_\parallel}{^s}/{\Delta}H$) after the alloys were aged at $500^{\circ}C$ for 100 h. This magnetic property of the $Fe_{70-x}Pd_{30}Ni_x$ (x = 6, 8 at.% Ni) alloys make it suitable for application in a high temperature (T > $500^{\circ}C$) and high frequency environments.

The Test of Combining Ability and Heterosis on the Silkworm(Bombyx mori) Breeding (누에 견.사질에 관한 잡종강세 및 조합능력검정)

  • 문병원;한경수
    • Journal of Sericultural and Entomological Science
    • /
    • v.36 no.1
    • /
    • pp.8-25
    • /
    • 1994
  • The study was conducted to obtain the genetic information on heterosis and combining ability of the quantitative characters for F1 hybrid breeding in silkworms. Six parental varieties and each set of 30 diallel crosses in F1's were used as materials, and bred on the randomized complete block design with three replications. Fourteen characters were observed with the twenty samples in each tray. The data were analyzed for (1) heterosis and combining ability in F1 hybrid. The heterosis in the weight and the length of cocoon showed positively high at 24.51%, and 23.4%, respectively and the weight of the whole cocoon as well as the weight of the whole cocoon layer showed a siginificant heterosis ranging from 15.56% to 15.71% and from 17.14% to 19.01%, but the fifth and the total instar period showed negative heterosis. It was found that the combination between, C70XRomogua and N9 X Romogua showed highly a negative heterosis on the fifth instar period and for the cocoon weight. The female of N9+Sansuian and the male of Romogua X Sansurian have a high heterosis effect, on the cocoon shell weight, and Sansurian X Romogua(reciprocal) on the length and the weight of cocoon filament with no regard to sexuality. The significant maternal and cytoplasmic effect on heterosis of the cocoon weight and the cocoon shell weight were observed with the combinations, N9 X C5, N63 X C70 and on the length of the cocoon filament with the combinations, Sansurian X N63, Sansurian X C5, Sansurian X C70 and N9 X C70, N63 X C70 on the weight of cocoon filament. As mean squared of GCA, SCA and RCA were significant with these combining ability for all characters resulted from additive and non-additive altogether and there is a significant difference between reciprocals. Sansurian showed a negative GCA effect on the fifth and total larval duration, but the higher positive GCA effects took places with varieties N9 and C5 on the length, width, weight of cocoon, cocoon shell weight, percentage of cocoon shell weight, length and weight of cocoon filament, percentage of raw-silk with no regard to both generations and silkworm sexuality. The values of SCA between the cross combinations varied generation-wise and sex-wise. It was shown that SCA value for the fifth instar period was highly negative for Sansurian X C70, Romogua X C70, Sansurian X C5, Romogua X C5, but it was positive effect on the cocoon weight, cocoon shell weight with N9 X C5, and C70 X Sansurian, on the length of cocoon filament with N9 X C5, Romogua X Sansurian on the weight of cocoon filament between Romogua and N63 and on the percentage of raw-silk between the combination of Sansurian X Romoga.

  • PDF

Estimation of fracture toughness of X65 and X70 steels by DWTT (X65 및 X70강 가스배관의 DWTT 및 파괴인성평가)

  • Cho, Ye-Won;Song, Young-Ho;Kim, Jeong-Min;Kim, Woo-Sik;Park, Joon-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.3
    • /
    • pp.54-64
    • /
    • 2012
  • DWTT (Drop Weigh Tearing Test) is one critical method that can exhibit the fracture properties of line pipe steel, since it estimates the properties with real pipe steel. In this study, the ductile portion, inverse fracture ratio and absorbed energy of API X65 and X70 line pipe steels were estimated with temperature variation. Both steels showed that the ratio of ductile area and absorbed energy were decreased with respect to decreasing the test temperature. However, while the ductile fracture behavior exhibited until $-40^{\circ}C$ for the X70 steel, but it showed until $-30^{\circ}C$ for the X65 steel. The fracture properties were discussed with respect to test temperatures.

Development of the Imaging Optical System for the 545 nm Fluorescent Plate of X-ray (X선용 545 nm 형광판 결상광학계 개발)

  • Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.17-22
    • /
    • 2008
  • To develop an imaging optical system for the 545 nm fluorescent plate of X-ray. Methods: We designed and manufactured a new imaging optical system for the 545 nm fluorescent plate of X-ray by Sigma 2000 program after deciding the design comparison standards referred to Canon CX2-70 model. Results: The characteristics of the new imaging optical system for the 545 nm fluorescent plate of X-ray have the magnification of -0.225x, the image field size of $90mm{\times}90mm$, and the 0.033 mm resolution line width at the 30% MTF value criterion. These mean that the new model has a capability of deciphering for the more large screen and the resolution of deciphering is superior to that of Canon CX2-70 model. Also the image side NA (-0.196) of the new model is about $\sqrt{2}$ times than that (-0.139) of CX2-70 and the object side NA (0.044) of the new model is about 2 times than that (0.022) of CX2-70. These mean that the sensitivity of the film in the new design model is able to be increased to about 4 times and there is the possibility of reducing the bombed time of X-ray to 1/4 times. Conclusions: We could design and manufacture the imaging optical system for the 545 nm fluorescent plate of X-ray having the possibility of reducing the bombed time of X-ray to 1/4 times in comparision to Canon CX2-70 model, the characteristics of which have the image field size of $90mm{\times}90mm$ and the MTF of 30% or more at 15 lines/mm criterion.

  • PDF

A Study on Hydrogen Damage in Base Metal of API X70 (API X70강 배관 모재부의 수소 손상에 관한 연구)

  • LEE, HO JUN;YU, JONG MIN;DAO, VAN HUNG;BAE, JAE HYEON;KIM, WOO SIK;YOON, KEE BONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.3
    • /
    • pp.284-292
    • /
    • 2020
  • In this study, hydrogen charging was conducted for API X70 steel by the electro-chemical hydrogen charging method. Right after hydrogen was diffused from the specimen surface to the inside of the X70, the small punch tests and hydrogen concentration analysis was conducted within 5 minutes. Hydrogen was analyzed by melting the whole specimen and detect the gas after melting. Mechanical properties were measured by the small punch (SP) testing. Fracture surface and specimen surface were observed using scanning electron microscope. Three tests were repeated for study sensitivity of the SP test results under a same charging condition. It was observed that the variation of the maximum load, SP displacement at failure, hydrogen concentration as the charging period was not much in the case of X70 as the other steel such as Inconel. It can be argued that X70 base metal may have high hydrogen damage resistance and hydrogen diffusion in the base metal would not cause much embrittlement. Limitations of the SP test with 0.5 mm thickness for hydrogen damage test for X70 were discussed.

Evaluation of HIC/SSCC Resistance for API-X70 Pipe Manufactured by JCO Bending Process and SA Welding (JCO 밴딩과 SA용접으로 제조된 API-X70급 강관의 HIC/SSCC 저항성 평가)

  • Ryoo, Hoi-Soo;Kim, Hee Jin;Lee, Dong-Eon
    • Journal of Welding and Joining
    • /
    • v.32 no.5
    • /
    • pp.1-6
    • /
    • 2014
  • This study aims at manufacturing SA welded API-X70 line-pipe with sour gas resistance. A pipe was manufactured by JCO bending process and SA welding using the API-X70 plate guaranteed HIC resistance. SA welded pipe was expanded in order to reduce the residual stress. The evaluation of a pipe for resistance to HIC and SSCC were performed by the RS D 0004 and RS D 0005 standards. For verification that a pipe has acceptable resistance to HIC, fullscale test was carried out. Results showed no cracking for the HIC and SSCC.

Effect of Spherodizing Heat-treatment Time on Microstructure and Mechanical Property in Accelerated Cooling-treated API-X70 Steel (가속냉각처리한 API-X70강의 미세조직과 기계적 특성에 미치는 구상화 열처리시간의 영향)

  • Bae, Dong-Su
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.5
    • /
    • pp.525-530
    • /
    • 2021
  • The purpose of this study was to investigate the effect of spherodizing heat treatment holding time on the microstructure and mechanical properties of the accelerated cooling-treated API X70 steel, which is mainly used as a structural material for line pipe steel for natural gas pipes. The accelerated cooling-treated API X70 steel was spherodizing treated at 700℃ for 12~48 h. The microstructure was observed using an OM and a FEG-SEM, and mechanical properties were obtained by tensile test. The microstructure of the API X70 steel was banded in the hot rolling direction, and the polygonal ferrite(PF) adjacent to pearlite(P) has mainly a fine size, and coarse PF and fine acicular ferrite were formed in the middle of P and P. As the spherodizing treatment time increased, the number of carbide particles decreased and its distribution interval increased, and the ferrite grain size was coarsened. The tensile strength decreased and the ductility increased with spherodizing treatment time, and the yield point elongation was disappeared in a stress-strain curve after the spherodizing treatment.

Monitoring Oxidation Behavior of [C70]Fullerene by Ultrasonic Spectroscopy ([C70]풀러렌 산화 반응의 거동에 관한 초음파 분광학적 고찰)

  • Ko, Weon Bae
    • Elastomers and Composites
    • /
    • v.49 no.2
    • /
    • pp.155-159
    • /
    • 2014
  • High resolution ultrasonic spectroscopy was used to observe the oxidation of [$C_{70}$]fullerene with 3-chloroperoxy benzoic acid in 1,2-dichlorobenzene. UV-vis spectroscopy and X-ray diffraction confirmed the resulting roducts of [$C_{70}$]fullerene oxidation.

Effect of Target Angle and Thickness on the Heel Effect and X-ray Intensity Characteristics for 70 kV X-ray Tube Target

  • Kim, Gyehong;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.272-276
    • /
    • 2016
  • To investigate the optimum x-ray tube design for the dental radiology, factors affecting x-ray beam characteristics such as tungsten target thickness and anode angle were evaluated. Another goal of the study was to addresses the anode heel effect and off-axis spectra for different target angles. MCNPX has been utilized to simulate the diagnostic x-ray tube with the aim of predicting optimum target angle and angular distribution of x-ray intensity around the x-ray target. For simulation of x-ray spectra, MCNPX was run in photon and electron using default values for PHYS:P and PHYS:E cards to enable full electron and photon transport. The x-ray tube consists of an evacuated 1 mm alumina envelope containing a tungsten anode embedded in a copper part. The envelope is encased in lead shield with an opening window. MCNPX simulations were run for x-ray tube potentials of 70 kV. A monoenergetic electron source at the distance of 2 cm from the anode surface was considered. The electron beam diameter was 0.3 mm striking on the focal spot. In this work, the optimum thickness of tungsten target was $3{\mu}m$ for the 70 kV electron potential. To determine the angle with the highest photon intensity per initial electron striking on the target, the x-ray intensity per initial electron was calculated for different tungsten target angles. The optimum anode angle based only on x-ray beam flatness was 35 degree. It should be mentioned that there is a considerable trade-off between anode angle which determines the focal spot size and geometric penumbra. The optimized thickness of a target material was calculated to maximize the x-ray intensity produced from a tungsten target materials for a 70 keV electron energy. Our results also showed that the anode angle has an influencing effect on heel effect and beam intensity across the beam.