고전압 방전 플라즈마에 의한 질화탄소 박막 층착 시 레이저 애블레이션 효과 (Effect of a Laser Ablation for Carbon Nitride Film Deposition)

  • 김종일
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.240-243
    • /
    • 2002
  • Carbon nitride films have been deposited on Si(100) substrate by a high voltage discharge plasma combined with laser ablation in a nitrogen atmosphere. The films were grown both with and without the Presence of an assisting focused Nd:YAG laser ablation. The laser ablation of the graphite target leads to vapor Plume plasma expending into the ambient nitrogen arc discharge area. X-ray photoelectron spectroscopy and Auger electron spectroscopy were used to identify the binding structure and the content of the nitrogen species in the deposited films. The surface morphology of the films was studied using a scanning electron microscopy Data of infrared spectroscopy and x-ray photoelectron spectroscopy indicate the existence of carbon-nitrogen bonds in the films. The x-ray diffraction measurements have also been taken to characterize the crystal properties of the obtain films.

  • PDF

Estimating Mass and Radius of a Neutron Star in Low-Mass X-ray Binary

  • 곽규진;성광현;김영민;김명국;이창환
    • 천문학회보
    • /
    • 제44권1호
    • /
    • pp.48.1-48.1
    • /
    • 2019
  • Mass and radius of a neutron star in low-mass X-ray binary (LMXB) can be estimated simultaneously when the observed light curve and spectrum show the photospheric radius expansion feature. This method has been applied to 4U 1746-37 and the mass and radius were found to be unusually small in comparison with typical neutron stars. We re-estimate the mass and radius of this target by considering that the observed light curve and spectrum can be affected by other X-ray sources because this LMXB belongs to a very crowded globular cluster NGC 6441. The new estimation increases the mass and radius but they do not reach the typical values yet.

  • PDF

양산에 적합한 구조의 X-ray 검출기 공정에 대한 연구

  • 권준환;오경민;송용근;김지나;노성진;남상희
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.265-266
    • /
    • 2012
  • 의료용 X-ray의 발전에 따라, 영상의 Digital화가 필요하게 되었다. Digital 영상 구현을 위해 다양한 형태의 영상 검출기가 개발되었다. 진단 영상의 조건으로는 구현 시간이 빠르고 해상도가 높아야 한다. 조건에 부합하는 Flat panel 형태의 직접방식과 간접방식 검출기의 개발이 주로 이루어졌으며, X-ray 검출 효율이 높고 공간 분해능이 높은 직접 방식의 검출기에 대한 연구가 활발히 진행되고 있다. 기존 직접방식의 X-ray 검출물질로는 A-Se이 이용되었다. 하지만 A-Se의 경우 낮은 원자번호로 인해 X-ray에 대한효율이 낮으며, 제조 공정과 수율의 문제로 인해 대체 물질의 개발과 공정의 개선이 필요하다. 선행 연구를 통해 X-ray 검출물질의 전기적 특성을 파악을 통해 대체 물질로서 가능성을 알아보았다. 본 연구에서는 기존에 제작된 X-ray 검출물질의 상부전극 증착 물질과 증착법 선정에 대한 연구이다. 선행 연구를 통해 선정된 X-ray 검출물질은 HgI2이다. 상, 하부 전극 선택에 있어 HgI2의 일함수 값(4.15eV)을 고려하여 그와 비슷한 일함수 값을 가진 물질로 전기적 장벽을 제거하여야 한다. 따라서, ITO (일함수 4.45eV)와 Au (일함수 5.1eV)을 선택하였다. ITO의 증착으로 이용된 방법으로는 on-axis 형태의 magnetron plasma sputtering을 이용하였으며, Au의 증착으로 이용된 방법은 Thermal evaporation deposition을 이용하였다. plasma sputtering에 이용된 타겟은 In2O3;SnO2 (조성비:90:10wt%)를 사용하였으며, Chamber의 크기는 넓이 456 ${\phi}cm^2$ 높이 25 cm이며, 로 target과 기판과의 거리는 15cm이다. plasma발생에 필요한 가스로는 Ar과 O2를 이용하였다. 고 진공 환경 조성에 이용된 장비로는 Rotary pump와 Turbo molecular pump이다. plasma 발생 전 진공도는 $3.2{\times}10^{-5}$ Torr, 발생 후 진공도는 $5.1{\times}10^{-5}$ Torr이다. plasma 환경이 조성된 후 증착 시간은 1분 30초이다. Au는 순도 99.999%를 이용하였으며, 이용된 금은 1회 증착에 0.3 g을 이용하였다. Chamber의 넓이 1,444 ${\phi}cm^2$이며, 높이 40 cm, boat와 기판과의 거리는 25 cm이다. 고 진공 환경 조성에 이용된 장비로는 Rotary pump와 diffusion pump를 이용하였다. Au의 승화 전 진공도는 $2.4{\times}10^{-5}$ Torr 증착 시 진공도는 $4.2{\times}10^{-5}$ Torr이며, Boat에 가해준 전압, 전류는 0.97 V, 47 A이며, 증착 시간은 1분 30초이다. 광도전체 층에 각각 증착된 전극의 저항을 통해 증착상태를 판단하였다. DMM (Digital Multimeter)로 1 cm 간격으로 측정된 표면의 저항은 ITO 약 $8{\Omega}$, Au 약 $3{\Omega}$으로 전극으로서 이용이 가능한 상태이다. Au와 ITO가 증착된 HgI2 시편의 전기적 특성은 기존에 이용된 X-ray 변환물질의 성능보다 우수하였다. 하지만 Au와 ITO가 각각 증착된 시편의 전기적 특성은 큰 차이를 보이지 않았다. ITO의 경우 진공 상태에서 이용되는 Gas가 이용되며, Plasma 환경 조성 유지가 어려운 점이 있다. Au전극은 증착 환경 조성이 쉽지만, 전극 물질 이용효율이 떨어지는 단점이 있다. 본 연구를 통해 X-ray 변환물질인 HgI2의 전극물질로 Au와 ITO의 이용가능성을 알아보았다. 두 전극으로 제작된 검출기의 성능은 큰 차이 없이 우수하였고, 전기적 장벽 상태가 낮아 높은 검출 효율을 보였다. 상대적으로 Au 전극의 공정이 간단하고 수율이 높다. 하지만 Au Source의 이용 효율이 떨어지는 단점이 있다. 본 연구의 결과를 통해 공정상의 유리함과 Source의 이용효율을 고려한 분석에 대한 연구가 필요할 것으로 사료된다.

  • PDF

다이오드 검출기를 이용한 초소형 X선관(Miniature X-ray Tube)의 반가층 측정 (HVL Measurement of the Miniature X-Ray Tube Using Diode Detector)

  • 김주혜;안소현;오윤진;지윤서;허장용;강창무;서현숙;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제23권4호
    • /
    • pp.279-284
    • /
    • 2012
  • X선은 방사선 진단과 치료 분야에 있어서 다양하고 광범위하게 이용되고 있으며, 최근에는 방사선 치료용 초소형 X선관이 개발되었다. 초소형 X선관은 조사 목적 부위에 직접 삽입하여 사용되므로 제작 시준기에 따라 다양한 각도로 X선 조사가 가능하고, 검사 목적 외의 환자 피폭선량을 최소화한다. 이러한 초소형 X선관의 장점을 이용해서 X선 영상을 획득하는데 적용한다면 X선 진단 분야의 새로운 장을 열 것으로 기대된다. 하지만 초소형 X선관은 본래 치료용으로 설계되었기 때문에 진단용 장비에 적합한 시준기, 필터(added filter) 등이 필요하다. 따라서 자체 제작한 시준기와 필터를 적용하여 초소형 X선관의 빔 특성이 진단용에 적합한지 평가 하였고, 이를 위해서 다이오드 검출기를 이용하여 반가층을 측정하고 측정의 가능성을 평가하였다. 본 연구에서는 Si PIN Photodiode type인 Piranha 검출기(Piranha, RTI, Sweden)를 사용하여 필터 적용 유무에 따른 초소형 X선관의 반가층을 측정하고, 알루미늄 필터를 사용한 측정을 통하여 Piranha 검출기의 반가층 측정의 정확성을 평가하였다. 측정 결과에 따르면 초소형 X선관의 반가층은 필터의 장착에 따라 약 1.9배 증가하여 진단용 방사선 발생 장치의 적합성을 확인하였다. Piranha 검출기의 반가층 자동 측정값은 필터를 미장착한 경우에 실제 반가층 측정값에 비해 50% 높게 측정되어 적용이 불가능하나, 필터를 장착한 경우에는 실제 반가층 측정값과 약 15%의 차이로 감소되었다. 따라서 진단용 필터를 적용했을 경우는 Piranha 검출기의 반가층 자동측정이 가능하여 kV-X선 특성평가를 수월하게 수행할 것으로 기대된다.

Average Glandular Dose In Mammography

  • Kim, K.H.;Ryu, Y.C.;Oh, C.H.
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.319-321
    • /
    • 2004
  • The average glandular dose (AGD) is determined by the breast entrance skin exposure, x-ray tube target material, beam quality (half-value layer), breast thickness, and breast composition. Almost breast cancer always arises in glandular breast tissue. As a result, the average radiation absorbed dose to glandular tissue is the preferred measure of the radiation risk associated with mammography. If the normalized average glandular dose is known, the average glandular dose can be computed from the product of the normalized average glandular dose and breast entrance skin exposure. In this study, AGD was calculated by the breast thickness and various x-ray energy (HVL) in 50% glandular 50% adipose breast by Mo.-Rh. assembly. AGD is 84 mrad in compressed 5 cm breast. These results show that as increasing the breast thickness, dose also increases. But as increasing the x-ray tube voltage, dose decreases because of high penetrating ratio through the object. But high tube voltage is reducing the subject contrast. From this result, we have to consider the trade-off between subject contrast of image and dose to the patient and choose proper x-ray energy range.

  • PDF

Development of a neural network method for measuring the energy spectrum of a pulsed electron beam, based on Bremsstrahlung X-Ray

  • Sohrabi, Mohsen;Ayoobian, Navid;Shirani, Babak
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.266-272
    • /
    • 2021
  • In the pulsed electron beam generators, such as plasma focus devices and linear induction accelerators whose electron pulse width is in the range of nanosecond and less, as well as in cases where there is no direct access to electron beam, like runaway electrons in Tokamaks, measurement of the electron energy spectrum is a technical challenge. In such cases, the indirect measurement of the electron spectrum by using the bremsstrahlung radiation spectrum associated with it, is an appropriate solution. The problem with this method is that the matrix equation between the two spectrums is an ill-conditioned equation, which results in errors of the measured X-ray spectrum to be propagated with a large coefficient in the estimated electron spectrum. In this study, a method based on the neural network and the MCNP code is presented and evaluated to recover the electron spectrum from the X-ray generated by collision of the electron beam with a target. Multilayer perceptron network showed good accuracy in electron spectrum recovery, so that for the X-ray spectrum with errors of 3% and 10%, the network estimated the electron spectrum with an average standard error of 8% and 11%, on all of the energy intervals.

수침 문화재 보존 처리에 있어 엑스선 조사의 연속성에 따른 살균력 효과 비교 (Comparison of the Effectiveness of Disinfection According to the Permanence of X-ray Irradiation for Preservation of Water-logged Cultural Heritages)

  • 조경서;곽영혁;이면주;정래동;박해준
    • 방사선산업학회지
    • /
    • 제17권4호
    • /
    • pp.533-542
    • /
    • 2023
  • We developed an emergency national manual for preservation of cultural heritage using irradiation disinfection technic under flood disaster. And we examined its practicality with a critical radiation dose on fungi that occur at water-logged event in order to prevent fungal damage that occurs during submersion. The X-ray irradiation for this experiment was conducted at the Production Technology Research Institute located in Yeongcheon, Gyeongsangbuk-do. A disinfection critical dose of 12 kGy was selected for two types of fungi known to spread rapidly and are resistant to radiation to submerged cultural properties, and this experiments were conducted by setting a target dose of 12kGy at 8.37mA at 5MeV. Under the above conditions, only continuity of irradiated samples were completely disinfected. This suggests that continuity of irradiation is important for fungal disinfection.

몰리브덴(Mo) 특성방사선 획득을 위한 다층박막 거울의 최적 설계 및 공차 분석 (Optimum Design and Tolerance Analysis of Multilayer Mirror for Obtaining Characteristic X-ray of 17.5 keV)

  • 천권수
    • 한국방사선학회논문지
    • /
    • 제3권4호
    • /
    • pp.23-28
    • /
    • 2009
  • 단색 엑스선은 적은 방사선 피폭으로 대조도가 높은 의료영상을 만들 수 있다. 엑스선 튜브와 다층박막 거울을 결합하면 높은 플루언스의 단색 엑스선을 얻을 수 있다. 몰리브덴(Mo) 타깃을 갖는 엑스선 튜브에서 Mo 특성방사선(17.5keV)을 높은 반사율로 획득하기 위한 W/C 다층박막 거울의 최적화를 수행하였다. 반사율이 최대가 되는 조건에서 두께주기와 두께비를 결정하였다. 최적 설계된 다층박막 거울에 대한 두께주기와 브래그 정렬에 대한 공차를 구하였다. 증착(deposition) 공차 0.2nm와 회전정렬 공차 ${\pm}0.01^{\circ}$에서 이론 반사율의 85% 이상에 해당하는 반사율이 얻어질 수 있다. 다층박막 거울을 이용하면 높은 플루언스의 특성방사선을 얻어 낼 수 있기 때문에 의료영상 획득 장치에 많이 사용될 것이다.

  • PDF

The X-ray Emission Properties of G308.3-1.4 and Its Central X-ray Sources

  • 서경애;우연주
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.147.2-147.2
    • /
    • 2011
  • We have initiated a long-term identification campaign of supernova remnant candidates in X-ray regime. In the short-listed unidentified sources from the ROSAT All Sky Survey, we have chosen the brightest candidate, G308.3-1.4, as our pilot target for a dedicated investigation with Chandra X-ray Observatory. Our observation has revealed an incomplete shell-like X-ray structure which well-correlated with the radio feature. Together with the spectral properties of a shocked heated plasma, we confirm that G308.3-1.4 is indeed a supernova remnant. A bright X-ray point source which locates close to the remnant center is also uncovered in this observation. Its spectral behavior conform with those observed in a rare class of neutron stars. The properties of its optical/infrared counterpart suggests the evidence for a late-type companion star. Interestingly, possible excesses in B-band and H-alpha have been found which indicate this can be an accretion-powered system. With the further support from the putative periodicity of ~1.4 hrs, this source can possibly provide the direct evidence of a binary system survived in a supernova explosion for the first time.

  • PDF

디지털유방촬영에서 Geant4-GATE를 이용한 산란선의 영향분석과 감소방안에 관한 연구 (Analysis of Scatter Ray Distribution Using GEANT4-GATE Simulation and Effectiveness of Silicone Pad in Digital Mammography)

  • 김명수;김영근;장영일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권3호
    • /
    • pp.175-180
    • /
    • 2019
  • In this study, we have researched the effectiveness of silicone pad. A distribution of scatter ray in mammography was evaluated using Monte-Carlo (MC) simulation technique and then a silicone pad was applied to remove the scatter ray for improving image quality. Molybdenum target and Molybdenum filter combination made a difference of 59.8% to a number of photon at 17.5 keV. On the other hand, Tungsten target and Rhodium filter showed a variation of 24.5% at 20 keV. Mean 68 of SNR was increased in Selenia and mean 1.04 of SNR was raised in Senographe. Silicone pad was significantly effective to reduce the scatter ray that was generated by primary X-ray. It can decrease an absorption rate of scatter ray to patient body and whilst it improve the image quality from increasing SNR.