• Title/Summary/Keyword: X-ray target

Search Result 471, Processing Time 0.031 seconds

Evaluation of Image Quality using Monte Carlo Simulation in Digital Mammography System (디지털유방영상시스템에서 몬테카를로 시뮬레이션을 이용한 영상평가)

  • Kim, Changsoo;Kang, Se-Sik;Kim, Jung-Hoon;Lee, Jin-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.6
    • /
    • pp.247-254
    • /
    • 2014
  • For the purpose of early diagnosis of the breast cancer, the attention on the screening mammography has been increasing-with supply of digital mammography day by day. Image quality is decided by target materials and filter combinations. Optimized selection by a glandular density and a thickness is needed, because these combinations change x-ray spectrum and effect to image quality. The purpose of this study is to find out optimized target and filter combinations through the evaluation of quantitative image quality and to suggest means which minimize patient dose through MCNPX. In results, spatial frequency resolution evaluation which is quantitative image quality evaluation method, MTF, NPS, DQE shows that we have to select Mo/Mo combinations or Mo/Rh combinations when compressed breast is thin. but in case of that when compressed breast is thick, we have to select Rh/Rh combinations or W /Rh combinations. In a comprehensive evaluation, W!Rh combinations which are not used in thin breasts in practice was superior to all image quality evaluation. This result is somewhat different-with clinical examination results. Secondary end point was organ dose evaluation, radiation dose of opposite breast was approximately 47 ~73% effectiveness when selecting standard breast. In conculsion, the most important point is that we have to select the optimal combinations-with considering dose evaluation and various thickness.

Characteristic of ITO-Ag-ITO multilayer thin films grown by linear facing target sputtering system (선형대향타겟 스퍼터로 성장시킨 ITO-Ag-ITO 다층박막의 특성 연구)

  • Jeong, Jin-A;Choi, Kwang-Hyuk;Lee, Jae-Young;Lee, Jung-Hwan;Bae, Hyo-Dae;Tak, Yoon-Heung;Ye, Min-Su;Kim, Han-Ki
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.66-66
    • /
    • 2008
  • 본 연구에서는 ITO/Ag/ITO 다층 박막을 유기발광소자와 플렉시블 광전소자의 전극으로 적용하기 위하여 선형 대항 타겟 스퍼터(Linear facing target sputter) 시스템을 이용하여 성막하였고, ITO/Ag/ITO 다층박막의 전기적, 광학적, 구조적 특성을 분석하였다. 선형 대항 타겟 스퍼터 시스템은 강한 일방항의 자계와 타겟에 걸린 음극에 의해 전자의 회전, 왕복 운동이 가능해 마주보는 두 ITO 타겟 사이에 고밀도의 플라즈마를 구속 시켜 플라즈마 데미지 없이 산화물 박막을 성막시킬 수 있는 장치이다. 대항 타겟 스퍼터 시스템을 이용하여 성막한 ITO 전극을 DC power, working pressure, Ar/O2 ratio 에 따른 특성을 각각 분석하였다. glass 기판위에 최적화된 ITO 전극을 bottom layer로 두고, bottom ITO layer 위에 thermal evaporation 을 이용하여 Ag 박막을 6~20nm의 조건에 따라 두께를 다르게 성막하고, Ag 박막을 성막한 후에 다시 bottom ITO 전극과 같은 조건으로 ITO 전극을 top layer로 성막 하였다. 두 비정질의 ITO 전극 사이에 매우 앓은 Ag 박막을 성막 함으로 해서 glass 기판위에 ITO/Ag/ITO 다층 박막전극은 매우 낮은 저항과 높은 투과도를 나타낸다. ITO/Ag/ITO 박막의 전기적 광학적 특성을 보기 위해 hall measurement와 UV/visible spectrometer 분석을 각각 진행하였다. ITO/Ag/ITO 다층 박막 전극이 매우 얇은 두께임에도 불구하고 $4\Omega$/sq.의 낮은 면저항과 85%의 높은 투과도를 나타내는 이유는 ITO/Ag/ITO 전극 사이에 있는 Ag층의 표면 플라즈몬 공명 (SPR) 현상으로 설명할 수 있다. ITO/Ag/ITO 전극의 Ag의 거동을 분석 하기위해 FESEM분석과 synchrotron x-ray scattering 분석을 하였다. ITO/Ag/ITO 전극의 Ag층이 islands의 모양에서 연속적으로 연결되는 변화과정 중에 SPR현상이 일어남을 알 수 있다. 여기서, 대항 타겟 스퍼터 시스템을 이용하여 성막한 ITO/Ag/ITO 다층박막을 OLED 또는 inverted OLEDs의 top 전극으로의 적용 가능성을 보이고 있다.

  • PDF

Behavior of Implanted Dopants and Formation of Molybdenum Siliclde by Composite Sputtering (Composite target으로 증착된 Mo-silicide의 형성 및 불순물의 거동)

  • Cho, Hyun-Choon;Paek, Su-Hyon;Choi, Jin-Seog;Hwang, Yu-Sang;Kim, Ho-Suk;Kim, Dong-Won;Shim, Tae-Earn;Jung, Jae-Kyoung;Lee, Jong-Gil
    • Korean Journal of Materials Research
    • /
    • v.2 no.5
    • /
    • pp.375-382
    • /
    • 1992
  • Molybdenum silicide films have been prepared by sputtering from a single composite MoS$i_2$ source on both P, B$F_2$respectively implanted (5${\times}10^{15}ions/cm^2$ single crystal and P implanted (5${\times}10^{15}ions/cm^2$) polycrystalline silicon substrates followed by rapid thermal annealing in the ambient of argon. The heat treatment temperatures have been varied in the range of 600-l20$0^{\circ}C$ for 20 seconds. The properties of Mo-silicide and the diffusion behaviors of dopant after the heat treatment are investigated using X-ray diffraction, scanning electron microscopy(SEM) , secondary ions mass spectrometry(SIMS), four-point probe and $\alpha-step.$ Annealing at 80$0^{\circ}C$ or higher resulted in conversion of the amorphous phase into predominantly MoS$i_2$and a lower sheet resistance. There was no significant out-diffusion of dopants from both single crystal and polycrystalline silicon substrate into molybdenum silicide layers during annealing.

  • PDF

Evaluation of Biological Characteristics of Neutron Beam Generated from MC50 Cyclotron (MC50 싸이클로트론에서 생성되는 중성자선의 생물학적 특성의 평가)

  • Eom, Keun-Yong;Park, Hye-Jin;Huh, Soon-Nyung;Ye, Sung-Joon;Lee, Dong-Han;Park, Suk-Won;Wu, Hong-Gyun
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.280-284
    • /
    • 2006
  • $\underline{Purpose}$: To evaluate biological characteristics of neutron beam generated by MC50 cyclotron located in the Korea Institute of Radiological and Medical Sciences (KIRAMS). $\underline{Materials\;and\;Methods}$: The neutron beams generated with 15 mm Beryllium target hit by 35 MeV proton beam was used and dosimetry data was measured before in-vitro study. We irradiated 0, 1, 2, 3, 4 and 5 Gy of neutron beam to EMT-6 cell line and surviving fraction (SF) was measured. The SF curve was also examined at the same dose when applying lead shielding to avoid gamma ray component. In the X-ray experiment, SF curve was obtained after irradiation of 0, 2, 5, 10, and 15 Gy. $\underline{Results}$: The neutron beams have 84% of neutron and 16% of gamma component at the depth of 2 cm with the field size of $26{\times}26\;cm^2$, beam current $20\;{\mu}A$, and dose rate of 9.25 cGy/min. The SF curve from X-ray, when fitted to linear-quadratic (LQ) model, had 0.611 as ${\alpha}/{\beta}$ ratio (${\alpha}=0.0204,\;{\beta}=0.0334,\;R^2=0.999$, respectively). The SF curve from neutron beam had shoulders at low dose area and fitted well to LQ model with the value of $R^2$ exceeding 0.99 in all experiments. The mean value of alpha and beta were -0.315 (range, $-0.254{\sim}-0.360$) and 0.247 ($0.220{\sim}0.262$), respectively. The addition of lead shielding resulted in no straightening of SF curve and shoulders in low dose area still existed. The RBE of neutron beam was in range of $2.07{\sim}2.19$ with SF=0.1 and $2.21{\sim}2.35$ with SF=0.01, respectively. $\underline{Conclusion}$: The neutron beam from MC50 cyclotron has significant amount of gamma component and this may have contributed to form the shoulder of survival curve. The RBE of neutron beam generated by MC50 was about 2.2.

Comparison of Average Glandular Dose in Screen-Film and Digital Mammography Using Breast Tissue-Equivalent Phantom (유방조직등가 팬텀을 이용한 Screen-Film과 Digital Mammography에서의 평균 유선선량)

  • Shin, Gwi-Soon;Kim, Jung-Min;Kim, You-Hyun;Choi, Jong-Hak;Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.13-23
    • /
    • 2007
  • In recent years, mammography system is changed rapidly from conventional screen-film system to digital system for application to screening and diagnosis. Digital mammography system provides several advantages over screen-film mammography system. According to the information provided by the manufacturer, digital mammography system offers radiation dose reduction in comparison with screen-film mammography system, because of digital detector, particularly direct digital detector has higher x-ray absorption efficiency than screen-film combination or imaging plate(IP). We measured average glandular doses(AGD) in screen-film mammography(SFM) system with slow screen-film combination, computed mammography(CM) system, indirect digital mammography(IDM) system and direct digital mammography(DDM) system using brest tissue-equivalent phantom(glandularity 30%, 50% and 70%). The results were shown as follows : AGD values for DDM system were highest than those for other systems. Although automatic exposure control(AEC) mode was selected, the curve of the AGD values against thickness or glandularity increased significantly for the SFM system with the uniform target/filter(Mo/Mo) combination. Therefore, the AGD values for the high energy examinations were highest in the SFM system, and those for the low energy examinations were highest in the DDM system. But the curve of the AGD values against thickness and glandularity increased gently for CM system with the automatic selection of the target/filter combination (from Mo/Mo to Mo/Rh or from Mo/Rh to Rh/Rh), and the AGD values were lowest. Consequently, the parameters in mammography for each exposure besides detection efficiency play an important role in oder to estimate a patient radiation dose.

  • PDF

Vacuum Web-coater with High Speed Surface Modification Equipment for fabrication of 300 mm wide Flexible Copper Clad Laminate (FCCL) (초고속 대면적 표면 처리 장치가 부착된 300 mm 폭 연성 동박적층 필림 제작용 진공 웹 코터)

  • Choi, H.W.;Park, D.H.;Kim, J.H.;Choi, W.K.;Sohn, Y.J.;Song, B.S.;Cho, J.;Kim, Y.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.2
    • /
    • pp.79-90
    • /
    • 2007
  • Prototype of $800{\ell}$ vacuum web coater (Vic Mama) consisting of ion source with low energy less than 250 eV for high speed surface modification and 4 magnetron sputter cathodes was designed and constructed. Its performance was evaluated through fabricating the adhesiveless flexible copper clad laminate (FCCL). Pumping speed was monitored in both upper noncoating zone pumped down by 2 turbo pumps with 2000 l/sec pumping speed and lower surface modification and sputter zone vacuumed by turbo pumps with 450 1/sec and 1300 1/sec pumping speed respectively. Ion current density, plasma density, and uniformity of ion beam current were measured using Faraday cup and the distribution of magnetic field and erosion efficiency of sputter target were also investigated. With the irradiation of ion beams on polyimide (Kapton-E, $38{\mu}m$) at different fluences, the change of wetting angle of the deionized water to polyimide surface and those of surface chemical bonding were analyzed by wetting anglometer and x-ray photoelectron spectroscopy. After investigating the deposition rate of Ni-Cr tie layer and Cu layer was investigated with the variations of roll speed and input power to sputter cathode. FCCL fabricated by sputter and electrodeposition method and characterized in terms of the peel strength, thermal and chemical stability.

Magnetic Properties of RF Diode Sputtered FeN Multilayer Films (RF Diode 스퍼터 방법으로 증착된 FeN 다층 박막의 자기적 특성)

  • 최연봉;박세익;조순철
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.1
    • /
    • pp.42-47
    • /
    • 1995
  • FeN thin films for inductive recording heads were sputter deposited using RF diode sputtering mehtod from a pure iron target onto 7059 glass substrates, and their magnetic properties were measured. The magnetic properties were greatly affected by film thickness, gas pressure, sputter power and flow ratio of $N_{2}$ to Ar. Single layer FeN films with their thickness varied from $1,000\;{\AA}$ to $6,000\;{\AA}$ were doposited. 800 W sputter power, 3 mT gas pressure, $N_{2}$ to Ar flow ratio of 6.6 : 100 were the sputtering conditions. Up to 7 layers of FeN films having total thickness of $6,000\;{\AA}$ were deposited using $SiO_{2}$ of $30\;{\AA}$ thickness as intermediate layers and their coercivity and saturation magnetization were measured. The sputtering conditions were the same as those in the single layer films. Easy axis coercivity of the single layer FeN films gradually decreased as their thickness was increased, but for the films with their thicknesses above $3,000\;{\AA}$, the coercivity changed very little. As the number of the FeN layers were increased, the coercivity decreased We estimated the grain size of FeN films from the FWHM (Full Width at Half Maximum) of X-ray diffraction peaks. The grain size steadily decreased from about $200\;{\AA}$ to $120\;{\AA}$ as the number of layers were increased. Minimum hard axis coercivity of 0.4 Oe was obtained when the number of layers was four. Maximum relative permeability was 2,900 when the number of layers was three. The cut off frequeocy of the multilayer films were above 100 MHz.

  • PDF

RADIOPACITY OF CAD/CAM CERAMICS (CAD/CAM용 도재의 방사선 불투과성에 관한 연구)

  • Lee, Jong-Hyeok;Choi, Han-Seuk;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.357-365
    • /
    • 1998
  • 목적: 치과용 수복재료의 방사선 불투과성은 매우 다양하다. 따라서 다양한 수복재료의 방사선 불투과성을 인지하여 치질과 비교하면 이차우식의 진단에 도움이 될 수 있다. 도재의 방사선 불투과성에 따라 적절한 luting cement의 선택이 가농해진다. 수복재료의 방사선 불투과성은 알루미늄 step wedge 의 후경과 방사선 불투과성과의 상관관계 의해 측정된다. 본 연구의 목적은 CAD/CAM용 도재와 이틀의 접착에 쓰이는 접착재료의 방사선 불투과성을 조사해 적절한 재료의 선택과 이차우식 진단의 효율결정에 도움이 되게 하는데 있다. 방법: 본 실험에서는 CAD/CAM용 도재인 Vita MarkII, Dicor MGC와 이의 접착에 사용되는 Z-100, 그리고 luting cement인 Duo cement, Scotchbond resin cement를 사용해 방사선 불투과성을 측정하였다. 시편 제작을 위해 도재를 저속절단기로 두께 2mm, 3mm로 절단하였으며 Z-100과 cement시편은 두께 2mm와 3mm, 직경 7.0mm의 금속 주형을 제작한 후 재료를 양쪽 면에 유리판을 대고 조임쇠로 압접하였으며 광조사기를 사용하여 각 재료마다 두 가지 두께로 10개씩 100개의 시편을 제작하였다. 치질의 시편을 얻기 위해 교정 목적으로 최근에 발거된 정상적인 상악 소구치를 저속 절단기를 사용하여 협설측 교두정을 기준 삼아 2mm, 3mm 두께로 절단하였으며 방사선 불투과성의 기준을 위해 12개의 step으로 구성된 12mm두께의 aluminum step wedge를 사용하였다. Kodak E-Speed occlusal film에 aluminum step wedge와 시편들을 위치시킨 후 70kVp, 7mA, 2.16mm aluminum filtration으로 고정된 dental X-ray unit을 사용하여 target과 film 사이의 거리는 25cm, 노출시간은 0.2초로 하여 방사선 촬영을 한 다음, 현상된 방사선 사진상에 나타난 방사선 불투과성을 X-rite 301 densitometer를 이용하여 측정한 값들의 평균을 냈다. 얻어진 결과는 one-way ANOVA Duncan test(P<0.01)로 검증하였다. 결론: 1. Dicor MGC의 방사선 불투과성은 법랑질보다 약간 높게 나타났다.(P<0.01) 2. Vita Mark Il는 상아질보다 낮은 방사선 불투과성을 보였다.(P<0.01) 3. Z-100과 Luting cement들의 방사선 불투과성은 법랑질보다 높았다. Duo cement가 방사선 불투과성이 가장 높았고 그 다음이 Z-100, 그리고 Scotchbond resin cement 순이었다. 4. Z-100과 2종류의 방사선 불투과성 luting cement들은 Vita Mark II 와 같이 사용하면 2차우식 진단에 도움이 된다.

  • PDF

Control of Chlorinated Volatile Pollutants at Indoor Air Levels Using Polymer-based Photocatalyst, Composite

  • Kim, Byeong-Chan;Kim, Hye-Jin;Kim, Ji-Eun;Park, Eun-Ju;Noh, Ji-Sun;Kang, Hyun-Jung;Shin, Seung-Ho;Jo, Wan-Kuen
    • Clean Technology
    • /
    • v.19 no.2
    • /
    • pp.105-112
    • /
    • 2013
  • In this study, polyaniline (PANI)-based $TiO_2$ (PANI-$TiO_2$) composites calcined at different temperatures were prepared and their applications for control of trichloroethylene (TCE) and tetrachloroethylene (TTCE) at indoor air levels were investigated. For these target compounds, the photocatalytic control efficiencies of PANI-$TiO_2$ composites did not exhibit any trend with varying calcination temperatures (CTs). Rather, the average control efficiencies of PANI-$TiO_2$ composites over 3-h photocatalytic process increased from 61 to 72% and from 21 to 39% for TCE and TTCE, respectively, as the CT increased from 350 to $450^{\circ}C$. However, for both the target compounds, the average control efficiencies of PANI-$TiO_2$ composites decreased gradually as the CT increased further to 550 and $650^{\circ}C$. These results were ascribed to contents of anatase crystal phase and specific surface area of different particle sizes in the PANI-$TiO_2$ composites, which were demonstrated by the X-ray diffraction and scanning electron microscopy images, respectively. At the lowest input concentration (IC, 0.1 ppm), average control efficiencies of TCE and TTCE were 72 and 39%, respectively, whereas at the highest IC (1.0 ppm) they were 52 and 18%, respectively. As stream flow rate increased from 0.1 to 1.0 L $min^{-1}$, the average control efficiencies of TCE and TTCE decreased from ca. 100 to 47% and ca. 100 to 18%, respectively. In addition, the average control efficiencies of TCE and TTCE decreased from ca. 100 to 23% and ca. 100 to 8%, respectively as the relative humidity increased from 20 to 95%. Overall, these findings indicated that as-prepared PANI-$TiO_2$ composites could be used efficiently for control of chlorinated compounds at indoor air levels;if operational conditions were optimized.

A Study on Apoptotic Signaling Pathway in HL-60 Cells Induced by Radiation (급성전골수성백혈병 HL-60 세포주에서 방사선조사에 의한 세포고사기전)

  • Kim Hye Jung;Moon Sung Keun;Lee Jae Moon;Moon Sun Rock
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.153-162
    • /
    • 2001
  • Purpose : The mechanical insights of death of cancer cells by ionizing radiation are not of yet clearly defined. Recent evidences have demonstrated that radiation therapy may induce cell death via activation of signaling pathway for apoptosis in target cells. This study is designed whether ionizing radiation may activate the signaling cascades of apoptosis including caspase family cysteine pretenses, $Bcl_2/Bax$, cytochrome c and Fas/Fas-L in target cells. Materials and Methods : HL-60 cells were irradiated in vitro with 6 MV X-ray at dose ranges from 2 Gy to 32 Gy. The cell viability was tested by M assay and the extent of apoptosis was determined using agarose gel electrophoresis. The activities of caspase proteases were measured by proteolytic cleavages of substrates. Western blot analysis was used to monitor PARP, Caspase-3, Cytochrome-c, Bcl-2, Bax, Fas and Fas-L. Results : Ionizing radiation decreases the viability of HL-60 cells in a time and dose dependent manner. Ionizing radiation-induced death in HL-60 cells is an apoptotic death which is revealed as characteristic ladder-pattern fragmentation of genomic DNA over 16 Gy at 4 hours. ionizing radiation induces the activation of caspase-2, 3, 6, 8 and 9 of HL-60 cells in a time-dependent manner. The activation of caspase-3 pretense is also evidenced by the digestion of poly (ADP-ribose) polymerase and procaspase 3 with 16Gy ionizing irradiation. Anti-apoptotic Bcl2 expression is decreased but apoptotic Bax expression is increased with mitochondrial cytochrome c release in a time- dependent manner. In addiiton, expression of Fas and Fas-L is also increased in a time dependent manner. Conclusion : These data suggest that ionizing radiation-induced apoptosis is mediated by the activation of various signaling pathways including caspase family cysteine proteases, $Bcl_2/Bax$, Fas and Fas-L in a time and dose dependent manner.

  • PDF