DUPIC 핵연료봉 봉단 용접부 건전성 확인을 위한 미세초점 X-선 투과시험에 관한 연구 (A Study on the Micro-Focus X-Ray Inspection for Confirming the Soundness of End Closure Weld of DUPIC Fuel Elements)

  • 김웅기;김수성;이정원;양명승
    • Journal of Welding and Joining
    • /
    • 제19권1호
    • /
    • pp.88-94
    • /
    • 2001
  • DUPIC (Direct use of spent PWR fuel in CANDU reactors) nuclear fuel is a CANDU fuel fabricated remotely from spent PWR fuel materials in a hot cell. The soundness of the end closure welds of nuclear fuel elements is an important factor for the safety and performance of nuclear fuel. To evaluate the soundness of the end closure welds of DUPIC fuel element, a precise X-ray inspection system is developed using a micro-focus X-ray generator with an image intensifier and a real time camera system. The fuel elements made of Zircaloy-4 and stainless steel by an Nd:YAG laser welding and a TIG welding aye inspected by the developed inspection system. The soundness of the welds of the fuel elements was confirmed by the X-ray inspection process, and the irradiation test of DUPIC fuel elements has been successfully completed at the HANARO research reactor.

  • PDF

Authentication Technologies of X-ray Inspection Image for Container Terminal Automation

  • Kim, Jong-Nam;Hwang, Jin-Ho;Ryu, Tae-Kyung;Moon, Kwang-Seok;Jung, Gwang-S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1684-1688
    • /
    • 2005
  • In this paper, authentication technologies for X-ray inspection images in container merchandises are introduced and a method of authentication for X-ray inspection images is proposed. Until now, X-ray images of container merchandises have been managed without any authentication of inspection results and environments, it means that there was no any action for protection of illegal copy and counterfeiting of X-ray images from inspection results. Here, authentication identifies that who did inspect container X-ray images and, whether the container X-ray images were counterfeited or not. Our proposed algorithm indicates to put important information about X-ray inspection results on an X-ray image without affecting quality of the original image. Therefore, this paper will be useful in determining an appropriate technology and system specification for authentication of X-ray inspection images. As a result of experiment, we find that the information can be embedded to X-ray image without large degradation of image quality. Our proposed algorithm has high detection ratio by Quality 20 of JPEG attack.

  • PDF

X-ray 컨테이너 화물검색시스템의 전자선형가속기 주변 콘크리트 차폐벽 내 방사화생성물에 대한 몬테카를로법 평가 (Monte carlo estimation of activation products induced in concrete shielding around electron linac used in an X-ray container inspection system)

  • 조영호
    • 한국산학기술학회논문지
    • /
    • 제11권3호
    • /
    • pp.1035-1039
    • /
    • 2010
  • 고에너지 X-ray를 투시 방사선원으로 사용한 컨테이너 화물검색시스템에서 생성되는 광중성자에 의해 주변 콘크리트 차폐벽에서 발생되는 방사화생성물을 평가하였다. 몬테카를로 전산해석 코드인 MCNPX2.5.0을 사용하였으며, 참조시스템은 국내 주요 항만에 설치된 9MeV X-ray 고정식 양방향 컨테이너 화물검색시스템이다. 9MeV X-ray 조사에 따라 생성되는 광중성자의 (n,$\gamma$) 반응에 의한 방사화생성물 재고량을 계산하고 이에 따라 야기되는 방사선 피폭선량을 계산하였다.

Calibration을 통한 스테레오 X-ray 검색장치의 기하구조 최적화 연구 (The Study of the Geometric Structure Optimization for the Stereo X-ray Inspection System Using the Calibration)

  • 황영관;이남호;이승민
    • 한국산학기술학회논문지
    • /
    • 제11권9호
    • /
    • pp.3422-3427
    • /
    • 2010
  • 본 논문에서는 빠르게 움직이는 화물 대상체의 효율적인 검색을 위해 스테레오 X-선 영상을 이용하여 장치 켈리브레이션을 통한 최적화된 구조에 대하여 연구하였다. 스테레오 X-선 스캔 영상은 X-선 발생장치, 듀얼 라인 어래이 검출기, 컨베이어 시스템 등으로 구성된 특별하게 제작된 스테레오 X-선 검색 장치로부터 획득하였다. 스테레오 X-선 영상을 이용하여 영상과 실제 대상체의 3차원 형상 구성사이의 관계를 찾기 위해 센서에 대한 캘리브레이션을 수행하였다. 스테레오 영상을 얻기 위해 구성된 두 개의 검출기 사이의 거리를 다양하게 변화 시키며 획득한 영상을 이용하여 영상에서의 GCP(Ground Control Point)에 대하여 계산 하였다. 계산된 GCP 값과 실제 대상체의 GCP의 좌표값을 비교하여 오차가 작은 효율적인 장치의 구조에 대하여 결과를 얻었다. 실험의 결과는 화물검색을 위한 영상의 효율적인 가시화 및 스테레오 매칭의 정확도를 향상시키기 위해 활용될 것이다.

PC based X-Ray Inspection system 개발에 관한 연구 (A Development of PC based X-Ray Inspection system)

  • 이기성;정태원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2049-2051
    • /
    • 2002
  • X-ray inspection of tires is now feasible and commercially available. The enabling technologies are economical yet powerful computing systems and high-resolution, high-dynamic range X-ray imaging systems customized for tire inspection. The key advantages of reduced inspection labor, highly consistent inspection and yield improvement are now realizable.

  • PDF

전파정류방식의 고전압발생장치를 이용한 X선 기기의 특성 평가 (Characteristic Analysis of X-ray Device using the High Voltage Generator on Full-wave Rectification Method)

  • 김영표;김태곤;이호식;박용필;천민우
    • 한국전기전자재료학회논문지
    • /
    • 제22권6호
    • /
    • pp.516-521
    • /
    • 2009
  • X-ray system which is usefully used in diagnosis of the patient, being bombed of radioactivity is a big weak point when irradiates a X-ray to the human body so that ICRP restricted the radiation exposure tolerance of the human body. In order to reduce being bombed, the many research and development is now advanced. A lots of diagnostic X-ray machines have currently used due to the increase of occurrence efficiency of X-ray and precisely the output control by using the inverter which is a high speed switching semiconductors. For getting the confidence of the X-ray machine, the same radiation occurrence, same evaluation, and same irradiation condition are necessary when evaluates X-ray irradiation. It is the most important part for the accuracy of the test result and the patient safety. This research has produced the high voltage occurrence system of full-wave rectification method by using the LC resonance inverter, and evaluated the irradiation reproducibility in order to use it in diagnosis of the patient.

중성자, 감마선, 엑스선 방사선 측정 및 통합 제어 시스템 개발 (Development of Neutron, Gamma ray, X-ray Radiation Measurement and Integrated Control System)

  • 고태영;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제21권4호
    • /
    • pp.408-411
    • /
    • 2017
  • 본 논문에서는 중성자, 감마선, 엑스선 등의 방사선을 측정하는 통합 제어 시스템을 제안한다. 제안하는 시스템은 원격 또는 네트워크상으로 측정 및 분석한 데이터를 디스플레이를 통해 모니터링 및 제어할 수 있는 장비로서, 현장에 가지 않고도 시스템 각 구성 부분의 상태를 보고 변경하여 원격으로 감시 및 관리할 수 있다. 제안하는 시스템은 감마선/엑스선 센서부, 중성자 센서부, 주제어 임베디드 시스템부, 전용 디스플레이 장치 및 GUI부, 원격 UI부 등으로 구성된다. 감마선/엑스선 센서부는 NaI(Tl) Scintillation Detector를 사용하여 저준위의 감마선 및 엑스선을 측정한다. 중성자 센서부는 Proportional Counter Detector(저준위 중성자)와 Ion Chamber Type Detector(고준위 중성자)를 사용하여 중성자를 측정한다. 주제어 임베디드 시스템부는 방사선을 검출하여 초단위로 샘플링하고 누적된 펄스 및 전류값에 대한 방사선량으로 변환한다. 전용 디스플레이 장치 및 GUI부는 방사선 측정 결과와 변환된 방사선량 및 방사능량 측정 수치를 출력하고, 사용자에게 제어 조건 설정 및 검출부에 대한 캘리브레이션 기능을 제공한다. 원격 UI부는 측정된 값들을 취합, 저장하여 원격 감시 시스템에 전달한다. 제안된 시스템의 성능을 평가하기 위하여 공인시험기관에서 실험한 결과는 중성자 검출부는 ${\pm}8.2%$ 이하의 측정 불확도가 측정되었고, 감마선, 엑스선 검출부는 7.5%이하의 불확도가 측정되어 국제 표준인 ${\pm}15%$ 이하에서 정상동작 됨이 확인되었다.

경사조사(傾斜照射) 강판튜브 방사선 관측영상의 수직 방향 공간분석 (Vertical Space Analysis for Gradient Radiating Steel-tube Radiographic Image)

  • 황중원;황재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.29-31
    • /
    • 2007
  • In this paper we propose an directional analytic approach in image data space for X-ray image which is detected from the X-ray projection system. Such a radiographic nondestructive testing has long been used for steel-tube inspection and weld monitoring. The welded area and thickness of steel-tube are detected from gradient radiating mechanism based on the evaluation of biased X-ray source position. The welded area is an ellipse type on low contrast X-ray image including noise. Noise originates from most of elements of the system. such as shielding CCD camera, imaging screen, X-ray source, inspected object, electronic circuits and etc.. Projection incorrectness and noise influence on imaging quality is to be represented by vertical pixels' distribution. Space analysis due to vertical direction also shows the segmental possibility between regions by visual edge evaluation.

  • PDF

X-선 튜브의 고전압 발생장치 제어에 관한 연구 (Study on Generator Control for a Small X-Ray Tube)

  • 이순혁;지윤서;최상규;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제25권4호
    • /
    • pp.248-254
    • /
    • 2014
  • 본 연구에서는 미국 Xoft 사에서 근접치료 장치(elecronic brachytherapy)를 목적으로 개발된 소형 X-선 튜브를 치과용 영상장비로 사용함에 있어서 고전압 발생장치의 제어용 장치를 개발하고 영상용 제어 방식으로 최적화하고자 한다. 연구에서 사용된 X-선 튜브와 고전압 발생 장치는 각각 Axxent S700과 XF060NZZ485를 사용하였고, AT90CAN128 MCU를 사용하여 제어보드를 제작하였다. 관전압을 50 kV로 고정한 후에 제어 방식에 따라서 필라멘트 전류 제어 방식과 관전류제어 방식으로 나누었다. 필라멘트 제어 방식은 다시 필라멘트 가열 시간에 따라서 5초와 10초의 두 가지로 나누어 실험하였다. 필라멘트 전류 제어 방식에서는 필라멘트 예열 시간이 10초 이상이 되지 않으면 설정된 관전류 값에 도달하기 어려웠고, 관전류가 발생하는 필라멘트 전류도 1,300~1,350 mA로 가변적이었으며, 관전류가 발생된 이후에도 설정된 목표 값에 도달하기 위해서는 약 5초 이상의 시간이 소요되었다. 하지만 관전류 제어 방식에서는 관전류가 설정된 목표 값에 시간 지연 없이 즉각적으로 도달하였으며 그 때의 필라멘트 전류 값은 1,500 mA였다. 본 연구에서는 소형의 X-선 튜브에 고전압을 안정적으로 공급하는 제어 장치를 개발하였고, 방사선 영상장비로 사용함에 있어서는 관전류 제어 방식이 적합함을 보였다.