Image Restoration in Dual Energy Digital Radiography using Wiener Filtering Method

  • Min, Byoung-Goo;Park, Kwang-Suk
    • 대한의용생체공학회:의공학회지
    • /
    • 제8권2호
    • /
    • pp.171-176
    • /
    • 1987
  • Wiener filtering method was applied to the dual energy imaging procedure in digital radiography(D.R.). A linear scanning photodiode arrays with 1024 elements(0.6mm H 1.3mm pixel size) were used to obtain chest images in 0.7 sec. For high energy image acquisition, X-ray tube was set at 140KVp, 100mA with a rare-earth phosphor screen. Low energy image was obtained with X-ray tube setting at 70KVp, 150mA. These measured dual energy images are represented in the vector matrix notation as a linear discrete model including the additive random noise. Then, the object images are restored in the minimum mean square error sense using Wiener filtering method in the transformed domain. These restored high and low energy images are used for computation of the basis image decomposition. Then the basis images are linearly combined to produce bone or tissue selective images. Using this process, we could improve the signal to noise ratio characteristics in the material selective images.

  • PDF

복부 단순 X선검사시 피복 선량에 관한 연구 (A study on the Radiation exposure of simple abdomen x-ray in Radiography)

  • 고인호;이경성;신동용
    • 대한방사선협회지
    • /
    • 제27권2호
    • /
    • pp.57-65
    • /
    • 2001
  • 본 연구는 복부 단순 X선 검사시 발생하는 피폭선량에 대하여 실험을 수행하였다. 피폭선량을 심부선량 백분율,표면선량,산란선량율으로 각각 측정하였다. 그결과는 다음과 같았다. 1. 관전압이 $60\~85kV$증가시 표면선량은 증가하고, 촬영거리를 50\~150cm$로 20cm씩 증가함에 mAs도 증가시킨 결과 표면선량은 감소되었다. 2. 심부선량 백분율은 $60kV\~75kV$에서는 4cm깊이에서

  • PDF

흉부 X-ray 사진 분석을 통한 코로나 판독 (COVID-19 Chest X-ray reading Technique based on Deep Learning)

  • 김성중;유재천
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2021년도 제63차 동계학술대회논문집 29권1호
    • /
    • pp.31-32
    • /
    • 2021
  • 신종 코로나바이러스 감염증(Coronavirus disease 2019; COVID-19)이 빠르게 확산됨에 따라 세계적인 전염병 대유행인 팬데믹(Pandemic)으로 선언되었다. 감염자들은 꾸준히 증가하고 있고 최근에는, 무증상 감염자들이 나타나고 있어 의심 환자를 조기에 판단하고 선별할 수 있는 기술이 필요하다. 본 논문에서는 흉부 방사선 검사(chest Radiography; CXR) 영상을 딥러닝(Deep Learning)하여 정상인, 폐렴 환자, 코로나바이러스 감염자를 분류할 수 있도록 한다.

  • PDF

흉부(胸部) X선촬영시(線撮影時) 부가여과사용(附加濾過使用)에 따른 선양(線量)과 선질(線質)에 관(關)한 연구(硏究) (A Study of Radiation Dose and Quality by Using Added Filtration in Chest Radiography)

  • 유병헌;추성실;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제10권1호
    • /
    • pp.13-23
    • /
    • 1987
  • Author has studied for finding the method of decreasing the radiation dose and increasing diagnostic range in chest X-ray radiography. The study for the added filter thickness from half value layer to 1/8 value layer by decreasing curve and research for the exposure factors, decreasing ratio of radiation dose, ratio of scatter ray and image quality in chest X-ray radiography. The results were as follows: 1. By using the rare earth intensifying screen system at 120 Kvp, the sensitivity is increased by times and the exposure ratio is decreased 0.22 by comparison with the $CaWO_{4}$ intensifying screen system at 80 Kvp. 2. By using Al added filter of 1/8 value layer, the scatter ray is increased more than no filter, But the scatter ray is decreased more in $G_{4}/RxOG$ intensifying system than in LT-II/Rx intensifying system. 3. At 120 Kvp, the image quality value of $G_{4}/RxOG$ system is increased more than LT-II/Rx system compared with slight decreasing image quality value at 80 Kvp. Concluded that by using the added filter could decrease the radiation dose by 1/3 and obtain effective image quality with the added filter at high voltage hard exposure.

  • PDF

이중 에너지 검출기를 이용한 영상 시스템 (Image System Using Dual Energy Detector)

  • 여화연
    • 한국산학기술학회논문지
    • /
    • 제11권9호
    • /
    • pp.3517-3523
    • /
    • 2010
  • 본 논문은 이중 에너지 DR(Digital Radiography) 방식 중, 단일 조사 X-선(single shot X-ray exposure) 장치와 이중 모드 검출기 모듈 (Low Energy Detector & High Energy Detector)을 이용한 이중 X-선 이미징이 가능한 검출기 모듈에 관한 연구이다. 상용 BIS(baggage inspection system)에서 사용되고 있는 X-선 발생장치의 스펙트럼과 이중 모드 검출기에 대한 특징 및 방사선적 특성을 분석하여 새롭게 제안 할 검출기 모듈의 최적 설계 방향을 기술하고 상용화된 용화된 LED 및 HED 검출기와 새롭게 제안 한 검출기 모듈에 대해 전기적, 광학적, 방사선적 특성 실험을 실시하여, 새롭게 제안된 검출기 모듈이 BIS 용도로 사용 가능함을 증명하였다. 새롭게 제안 된 검출기 모듈이 적용된 BIS에 대해, 기본 특성 실험에 대한 X-선 영상을 획득하여 실험 및 분석을 실시하였다.

CR을 이용한 일반촬영장치의 MTF 측정 (The MTF Measurement of the Conventional X-ray System by using the Computed Radiography)

  • 김창복
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권2호
    • /
    • pp.111-115
    • /
    • 2005
  • X-선을 이용하여 의료영상을 생성하는 시스템은 X-선 발생장치, 피사체, 영상전달매체 등의 여러 가지 차이에 따라 영상의 질이 결정된다. 즉, X-선 발생에서 최종영상에 이르기까지 화질에 영향을 미치는 요소가 다양하다는 것이다. 따라서 임상에서 영상을 생성하는 사용자는 최종영상에서 계속적인 영상의 평가와 관찰이 필요하다. 의료영상을 평가하는 방법에는 여러 가지가 있지만, 그 중 실질 또는 실효해상도를 측정하는 방법으로 MTF 측정방법이 적절하다고 할 수 있다. 따라서 본 연구에서는 X-선 필름을 이용하여 MTF를 계산하는 방법을 탈피하고, 디지털 의료영상의 MTF를 측정할 수 있는 소프트웨어(Borland C++ builder 소프트웨어와 LEAD tools 소프트웨어를 이용한 프로그램)를 이용하여 X-선 장비의 노후화 정도에 따른 MTF 특성을 측정하였다. 측정결과, 사용연수와 사용횟수가 오래된 X-선 발생장치는 최신 장치에 비해 해상력(resolution)과 선예도(sharpness) 등의 화질이 저하되는 것을 MTF 그래프를 통해 확인할 수 있었다. 또한, 디지털 의료영상에서도 간단하고 쉽게MTF를 측정할 수 있는 방법을 얻을 수 있었다.

  • PDF

방사선촬영 보조기구를 이용한 어린이 흉부 엑스선 검사에 관한 연구 (A Study on Chest X-ray Using Ancillary Device for Child Radiography)

  • 이도병;이소미;최현우;김종기;이종민
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권1호
    • /
    • pp.48-54
    • /
    • 2018
  • In this study, We developed a Ancillary device for child radiography for X-ray of children under 5 years old and verified its effectiveness. Chest X-rays of children younger than 5 years of age were performed by Supine method at the position of Table detector, Short - Source to Image Receptor Distance(SID). Existing Supine and Short -SID imaging methods cause many problems, such as errors in image reading and excessive radiation exposure dose to patients, but the use of an Ancillary device for child radiography(ADCR) solves these problems. A total of 160 children were divided into the Upright group using ADCR and Supine group without ADCR. The chest X-ray image was visually evaluated by two radiologists with reference to the European Commission's List of Quality Criteria for Diagnostic Radiographic Images in Pediatrics. The total score of the qualitative evaluation was 5.15% higher in the chest upright method using ADCR than in the chest supine method without ADCR, and the chest upright method score was higher than that of the chest supine method in items 1 to 7. whether infants have deep inspiration or not, 4.87% higher for item 1, whether infants rotate or not and the degree of tilting, 0% higher for the item 2, the reproduction of image from just above apices of lungs to T12/L1, 0% for the item 3, reproduction of the vascular pattern in central 2/3 of the lungs, 6.92% higher for the item 4, reproduction of the trachea and the proximal bronchi, 12.9% higher for the item 5, visually sharp reproduction of the diaphragm and costo-phrenic angles, 10% higher for the item 6, reproduction of the spine and paraspinal structures and visualisation of the retrocardiac lung and the mediastinum, and 3.65% higher for the item 7. Items 2 and 3 showed no statistically significant differences(P > 0.05), and items 1, 4, 5, 6, and 7 showed statistically significant differences(P < 0.05). In conclusion, Upright method using ADCR in pediatric chest X-ray is considered as a good alternative to existing Supine method.

X-선 투과특성을 고려한 외주형 수술용 테이블 개발 (Development of a Cantilevered Patient Table Considering X-ray Transparency)

  • 원병희;전경진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.189-190
    • /
    • 2006
  • A patient table considering x-ray transparency, mechanical safety and compact multi-axis moving mechanism has been developed. The goal of medical imaging technology is to keep radiation exposure of patients during x-raying to a minimum. In order to obtain clear pictures at low dose, however, the x-ray table which supports the patient must be sufficiently permeable to radiation to allow good image resolution. The table top is made of low density foam for x-ray transparent effective area and structural aluminum plate to connect moving mechanism under the table, covered with thin carbon fiber. This sandwich construction is very rigid and lightweight, so the table top can handle relatively heavy load comparing to its cantilevered structure which is unavoidable as long as cooperate with C-arm radiography. To verify the design results finite element static analysis and experimental tests have been done. According to the verification the results well satisfy certification guide lines as a medical device.

  • PDF

한국인의 디지털파노라마 방사선영상에서 하악관에 관한 연구 (A study of the mandibular canal in digital panoramic radiographic images of a selected Korean population)

  • 김재덕;김진수
    • Imaging Science in Dentistry
    • /
    • 제37권1호
    • /
    • pp.9-14
    • /
    • 2007
  • Purpose : To determine the more valuable information to detect the mandibular canal and the mental foramen in panoramic radiographs of a selected Korean population for the implant. Materials and Methods : This study analysed 288 panoramic radiographic images of patients taken at the Dental hospital of Chosun University retrospectively. Indirect digital panoramic X-ray machine (ProlineXC, PLANMECA, Finland) with processing by using Directview $CR950^@$ (Kodak, U.S.A.) and Direct digital panoramic X-ray machine (Promax, PLANMECA, Finland) were used for all exposures. All images were converted into Dicom format. Results : The common position of the mental foramen was in line with the longitudinal axis of the second premolar (68.1%). The mental foramen was symmetrical in 81.8% of cases. The mandibular canal was not identified at anterior portion and discontinued with the mental foramen in 27.8% of all cases, in 42.4% identified with lower border line continued with the mental foramen, in 14.6% with both upper and lower border lines, and in 15.3% unilaterally identified with lower border line. Conclusion : Clinicians can estimate the upper border line of the mandibular canal from the confirmation of the mental foramen and the lower border line of the mandibular canal symmetrically on the panoramic radiography taken in adjusted midsaggital plane of patient's head.

  • PDF

GATE 시뮬레이션을 사용한 알루미늄 부가필터 두께에 따른 Digital Radiography의 영상 화질 비교 평가 (Comparison Evaluation of Image Quality with Different Thickness of Aluminum added Filter using GATE Simulation in Digital Radiography)

  • 오민주;홍주완;이영진
    • 한국방사선학회논문지
    • /
    • 제13권1호
    • /
    • pp.81-86
    • /
    • 2019
  • X-선 영상에서 필터를 통한 여과의 역할은 영상 형성에 유용한 광자를 이용해 환자의 피폭량을 낮춤과 동시에 영상의 대조도를 높이는 것이다. 영상을 형성하는 데 있어서 저에너지 X-선은 환자 조직의 최초 몇 cm 부위에서 흡수되고 고에너지 부분만을 통과하여 형성되므로, 방사선 여과는 여과물질을 삽입하여 저에너지 X-선을 여과물질로 하여금 흡수시켜 환자의 피폭량을 낮추고 영상의 질을 높인다. 본 연구의 목적은 시뮬레이션을 통해 이상적인 환경에서 부가 필터가 방사선 영상 촬영 시 영상의 화질에 미치는 영향을 확인하고, 실제 방사선 영상을 촬영할 경우와 비교하는 것이다. 이를 위해 시뮬레이션 프로그램인 Geant4 Application for Tomographic Emission (GATE)를 이용해 Polymethylmethacrylate (PMMA) Phantom의 실제 크기, 모양과 재질을 모사하고 부가 필터의 사용유무 및 필터의 두께에 따른 촬영 조건을 설정하여 시뮬레이션 결과 영상을 얻어냈다. 또한, Digital Radiography (DR)장비로 실제 PMMA Phantom을 필터가 없는 경우와 필터가 있을 때 그 두께를 변화시키며 촬영했다. 시뮬레이션의 결과 영상과 실제 실험을 통해 얻은 영상을 각각 Image J 프로그램을 이용해 Contrast-to-noise ratio (CNR) 평가를 실행한 뒤, 시뮬레이션 결과 영상과 최종적으로 도출된 두 영상의 변화 추이를 비교 측정했다. 실험 결과 DR장비와 시뮬레이션 영상 모두 CNR이 감소하는 추세를 보였으며, 이는 결국 영상에서의 대조도 감소로 인해 나타난 결과였다. 이론적으로 관전압 (kVp)이 증가하면 대조도가 감소하고, 이를 통해보았을 때 필터는 저에너지부의 X-선을 흡수하면서 전체적인 선량을 감소시키지만, X-선의 평균에너지를 증가시키는 역할을 한다는 것을 알아볼 수 있었다.