• 제목/요약/키워드: X-ray method

검색결과 4,399건 처리시간 0.031초

A method of X-ray source spectrum estimation from transmission measurements based on compressed sensing

  • Liu, Bin;Yang, Hongrun;Lv, Huanwen;Li, Lan;Gao, Xilong;Zhu, Jianping;Jing, Futing
    • Nuclear Engineering and Technology
    • /
    • 제52권7호
    • /
    • pp.1495-1502
    • /
    • 2020
  • A new method of X-ray source spectrum estimation based on compressed sensing is proposed in this paper. The algorithm K-SVD is applied for sparse representation. Nonnegative constraints are added by modifying the L1 reconstruction algorithm proposed by Rosset and Zhu. The estimation method is demonstrated on simulated spectra typical of mammography and CT. X-ray spectra are simulated with the Monte Carlo code Geant4. The proposed method is successfully applied to highly ill conditioned and under determined estimation problems with a good performance of suppressing noises. Results with acceptable accuracies (MSE < 5%) can be obtained with 10% Gaussian white noises added to the simulated experimental data. The biggest difference between the proposed method and the existing methods is that multiple prior knowledge of X-ray spectra can be included in one dictionary, which is meaningful for obtaining the true X-ray spectrum from the measurements.

The Compound Refractive Lens for Hard X-ray Focusing

  • Choi, J.;Jung, J.;Park, S.;Kwon, T.
    • Journal of the Optical Society of Korea
    • /
    • 제11권2호
    • /
    • pp.76-81
    • /
    • 2007
  • The compound refractive X-ray lens (CRL) for focusing hard X-rays is investigated to determine the parameters such as the focal length, the focal spot size, and spatial distribution at the focal spot using a simple theoretical calculations and CRLs fabricated by the self-assembly method. The number of individual compound lenses are defined for the given focal length of 1 m. The X-ray energy of 1 to 40 keV is used in the calculations. The CRL for focusing hard X-rays which generated from the X-ray tube is fabricated by nanoparticle-polymer composite in the form of circular concaves. The self-assembly method is applied to form the nanoaluminum-poly (methly meth-acrylate) composite and carbon-polymer composite CRL lenses. Aluminum nanoparticles of 100 nm and carbon microparticles are diffused in the polymer solution then the high gravity up to 6000G is applied in it to form the concave lens shape. X-ray energy at 8 keV is used for characterization of the composite CRLs. The FWHM of intensity for the fabricated nanoaluminium composite CRL system, N=10 is measured as 1.8 mm, which would give about $70{\mu}m$ in FWHM at 1 m of the focal length.

Experimental Evaluation of Scattered X-Ray Spectra due to X-Ray Therapeutic and Diagnosis Equipment for Eye Lens Dosimetry of Medical Staff

  • Kowatari, Munehiko;Nagamoto, Keisuke;Nakagami, Koich;Tanimura, Yoshihiko;Moritake, Takashi;Kunugita, Naoki
    • Journal of Radiation Protection and Research
    • /
    • 제47권1호
    • /
    • pp.39-49
    • /
    • 2022
  • Background: For proper monitoring of the eye lens dose, an appropriate calibration factor of a dosimeter and information about the mean energies of X-rays are indispensable. The scattered X-ray energy spectra should be well characterized in medical practices where eye lenses of medical staffs might be high. Materials and Methods: Scattered X-ray energy spectra were experimentally derived for three different types of X-ray diagnostic and therapeutic equipment, i.e., the computed tomography (CT) scan, the angiography and the fluoroscopy. A commercially available CdZnTe (CZT) spectrometer with a lead collimator was employed for the measurement of scattered X-rays, which was performed in the usual manner. Results and Discussion: From the obtained energy spectra, the mean energies of the scattered X-rays lied between 40 and 60 keV. This also agreed with that obtained by the conventional half value layer method. Conclusion: The scattered X-rays to which medical workers may be exposed in the region around the eyes were characterized by means of spectrometry. The obtained mean energies of the scattered X-rays were found to match the flat region of the dosimeter response.

디지털 영상 합성에 의한 X선 단층 영상의 형상 정확도와 선명도 분석 (Analysis of X-ray image Qualities -accuracy of shape and clearness of image using X-ray digital tomosynthesis)

  • 노영준;조형석;김형철;김성권
    • 제어로봇시스템학회논문지
    • /
    • 제5권5호
    • /
    • pp.558-567
    • /
    • 1999
  • X-ray laminography and DT(digital tomosynthesis) that can form a cross-sectional image of 3-D objects promis to be good solutions for inspecting interior defects of industrial products. DT is a kind of laminography technique and the difference is in the fact that it synthesizes the several projected images by use of the digitized memory and computation. The quality of images acquired from the DT system varies according to image synthesizing methods, the number of images used in image synthesizing, and X-ray projection angles. In this paper, a new image synthesizing method named 'log-root method' is proposed to get clear and accurate cross-sectional images, which can reduce both artifact and blurring generated by materials out of focal plane. To evaluate the quality of cross-sectional images, two evaluating criteria : (1) shape accuracy and (2) clearness of the cross-sectional images are defined. Based on these criteria, a series of simulations are performed, and the results show the superiority of the new synthesizing method over the existing ones such as averaging and minimum methods.

  • PDF

퍼지를 이용한 X-ray 영상의 대비제한 적응 히스토그램 평활화 한계점 결정 (The Clip Limit Decision of Contrast Limited Adaptive Histogram Equalization for X-ray Images using Fuzzy Logic)

  • 조현지;계희원
    • 한국멀티미디어학회논문지
    • /
    • 제18권7호
    • /
    • pp.806-817
    • /
    • 2015
  • The contrast limited adaptive histogram equalization(CLAHE) is an advanced method for the histogram equalization which is a common contrast enhancement technique. The CLAHE divides the image into sections, and applies the contrast limited histogram equalization for each section. X-ray images can be classified into three areas: skin, bone, and air area. In clinical application, the interest area is limited to the skin or bone area depending on the diagnosis region. The CLAHE could deteriorate X-ray image quality because the CLAHE enhances the area which doesn't need to be enhanced. In this paper, we propose a new method which automatically determines the clip limit of CLAHE's parameter to improve X-ray image quality using fuzzy logic. We introduce fuzzy logic which is possible to determine clip limit proportional to the interest of users. Experimental results show that the proposed method improve images according to the user's preference by focusing on the subject.

PIB법을 이용한 대면적 $HgI_2$ 검출기의 I-V 특성평가 (I-V Measurements of large area $HgI_2$ X-ray detector produced by PIB method)

  • 김경진;박지군;강상식;차병열;조성호;신정욱;문치웅;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.254-255
    • /
    • 2005
  • In this paper, we investigated electrical characteristics of the X-ray detector of mercuric iodide (HgI2) film fabricated by PIB(Particle-in-Binder) Method on ITO substrates 17cm$\times$20cm in size with thicknesses ranging from approximately 200${\mu}m$ to 240${\mu}m$. In the present study, using I-V measurements, their electrical properties such as leakage current, X-ray sensitivity, and signal-to-noise ratio (SNR),were investigated. The results of our study can be useful in the future design and optimization of direct active-matrix flat-panel detectors (AMFPD) for various digital X-ray imaging modalities.

  • PDF

MOSFET를 이용한 X선 신호의 전기적 획득에 관한 연구 (The study for electric readout of X-ray signal using MOSFET)

  • 박성광;강영수;서지현;박지군;남상희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.295-296
    • /
    • 1998
  • With xeroradiography appearance, DR (Digital Radiography) system have been studying for X-ray detection using photoreceptor. Also detection method for receptor charge change have been developing variably. We use photoreceptor material of a-Se(Amorphous Selenium) with high DQE, high SNR(Signal to Noise Ratio) and high transformation efficiency of X-ray signals into electrical signals. After a-Se receptor is uniformly charged by using Arc discharge, X-ray is exposed. Then a-Se receptor produce subtle charge variation and MOSFET detect charge variations. The detected signal pass A/D converter and signal processing by PC. As results, the initial voltage is 8V. It has wide dynamic range needed digital radiography system. In this study, we obtained data with changing kVp(tube potential voltage) and fixed 8mAs(tube current by exposure time) in X-ray system. However MOSFET detector for X-ray signal is not tested X-ray mAs variations. But if MOSFET detector is tested X-ray mAs variation and exactly calibrated multichannel is made and noise-reduction is done, suitable DR system readout method will be done.

  • PDF

X-선 분석법을 이용한 난연 EPS 샌드위치 패널의 화재성능평가 방법에 관한 연구 (Fire Performance Testing Method for Fire Retardant EPS Sandwich Panel Using X-ray Analysis)

  • 심지훈;조남욱
    • 한국화재소방학회논문지
    • /
    • 제29권6호
    • /
    • pp.76-83
    • /
    • 2015
  • EPS 샌드위치 패널은 난연제의 첨가로 화재 시 발화를 늦춰주며 발열을 적게 발생시켜 연소의 확대를 막는다. 하지만 난연성능 기준에 미달하는 샌드위치 패널을 사용할 경우, 재산 및 인명 피해가 확대되는 사례가 발생할 수 있다. 마감재료의 난연성능은 육안으로는 확인이 어려워 간편하면서도 빠른 평가방법의 개발이 요구된다. 본 연구에서는 X-선 분석법(XRF, XRD)을 이용하여 EPS 샌드위치 패널의 화재안전평가 방법에 대해 분석하였다. X-선 분석법을 적용한 결과 화재시험을 통한 난연 성능에 따라 특정 성분이 검출되는 것을 확인하였다. X-선 형광분석(XRF)을 통해 알루미늄성분이 부적합제품에 비해 적합제품에 훨씬 많이 함유되어있는 것을 알 수 있었다. X-선 회절분석(XRD)을 통해 난연 EPS의 주된 결정성 물질로 확인된 깁사이트(gibbsite)는 적합제품과 부적합제품에 공통으로 함유되어 있었지만 결정성에 있어 차이가 나는 것을 확인하였다. 이러한 X-선 분석을 통한 원소분석과 결정분석으로 난연성능 평가 가능성을 확인하였다.

유한요소법을 이용한 X-선관 양극각도에 의존하는 전자빔 초점 특성 연구 (Property of Focal Spot of Electron Beam Depending on the Anode Angle of X-ray Tube Using a Finite Element Method)

  • 박태영;노영일;이상석;박래준;김기선
    • 한국자기학회지
    • /
    • 제25권2호
    • /
    • pp.52-57
    • /
    • 2015
  • 텅스텐 타겟인 양극의 각도에 의존하는 X-선관 집속관의 전자빔 초점 크기를 오페라-3차원/스칼라(OPERA-3D/SCALAR) 프로그램을 이용하여 구하였다. 시뮬레이션 분석은 X-선관을 음극과 양극 그리고 4영역을 나누어 유한요소법을 적용하였다. X-선 집속관의 필라멘트로부터 방출되는 열전자 궤적은 전자밀도 분포함수에 따라 양극에 도달할 때 실초점으로 집속되고 양극에 부딪쳐서 유효 초점 크기로 X-선을 발생하게 된다. 전자빔 실초점 크기는 X-선 집속관 모양을 결정짓는 폭, 길이, 높이를 조절하여 줄일 수 있었고, 양극각도의 크기에 따라 미세하게 변하였다. 양극각도가 $10^{\circ}{\sim}17^{\circ}$에서는 전자빔 실초점 크기를 $70{\mu}m$ 이내로 유지하였고, 가장 최소 초점크기는 $15^{\circ}$에서 실초점 크기가 $40{\mu}m$로 나타났다. 최적화된 X-선 집속관의 변수들로 시뮬레이션하는 열전자의 방출 궤적을 분석하여 얻은 마이크로 크기인 실초점을 활용하는 새로운 의료 영상진단기기 개발이 가능할 것으로 보여진다.

입력전원의 변화에 따른 X선 기기의 특성평가 (Characteristic of X-ray Equipment according to the Input Power Condition)

  • 김영표;김태곤;천민우;박용필
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 추계학술대회
    • /
    • pp.773-775
    • /
    • 2010
  • 의료용 X-선 고전압발생장치는 작동 시 높은 용량의 입력전원이 필요하며, 만약 전원환경이 적합하지 않을 경우 X-선 고전압발생장치를 사용하지 못하거나 불안정한 작동으로 인해 원활한 작동이 불가능해 진다. 전원환경에 따라 제품이 불안정 할 경우 환자 진료에 지장이 생길 수 있는 것을 감안하여 상용전원을 사용하지 않고 의료용 X-선 고전압발생장치를 작동 할 수 있는 전원장치를 배터리를 활용하도록 하였다. 전원회로를 설계한 후 시제품을 제작하여 본 논문에 제시된 방법에 따라 상용전원과 배터리 전원을 각각 비교하여 의료용 X-선 고전압발생장치가 입력전원방식에 따라 어떤 특성과 효율을 가지고 있는지 확인하였다.

  • PDF