• Title/Summary/Keyword: X-ray fluorescence spectrometry

Search Result 56, Processing Time 0.027 seconds

Determination of Trace Elements in Atmospheric Dust by X-Ray Fluorescence Spectrometry(II) : X-ray Fluorescence Spectrometric Determination of Light Elements (형광 X선에 의한 대기분진중의 미량성분의 측정(II): 대기부유분진 중 경원소의 X-선 형광분석)

  • 이용근;박현미;이동수;이보경
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.247-254
    • /
    • 1993
  • A simple and direct method is developed for the determination of light Elements in atmospheric particulates by X-ray fluorescence spectrometry. Calibration standards for the light elements such as Al, Mg, K, Ca, etc are prepared by filtering real atmospheric particulates over variable time and subsequently standardizing them by Inductively Coupled Plasma-Mass Spectrometry(ICP-MS) or Atomic Absorption Spectrophotometry(AAS) analysis. The validity of this calibration method is tested by analyzing more than 100 aerosol samples, collected at urban(Seoul) and rural(Padori) sites over a two year period with this method and then comparing them with those by other accuracy proven methods such as AAS or ICP-MS: for all metals tested the results showed reasonably good agreements (R $\geq$ 0.95).

  • PDF

Comparative Studies on the Discrimination of Angelicae Gigantis Radix by Near-infrared Spectroscopy, Electronic Nose and X-ray Fluorescence Spectrometry (근적외선분광법, 전자코 및 엑스선형광법을 이용한 당귀의 기원판별법 비교 연구)

  • 조창희;김수정;김효진
    • YAKHAK HOEJI
    • /
    • v.46 no.3
    • /
    • pp.161-167
    • /
    • 2002
  • Angelicae gigantis radix is the root of the perennial plant, which belongs to the family Umbelliferae. However, this herbal drug is represented quite different chemical components according to its different genus name, though other herbal drugs (i.e. Leonuri Herba, Xanthii Fructus and so on) show similar constituents on the same name. The root of Angelica gigas containing the coumarin compounds is commonly used in Korea, while Angelica sinensis and Angelica acutiloba including phthalide compounds are used in China and Japan, respectively as Angelicae gigantis radix. In this paper, a nearinfrared spectroscopic method was developed to determine genus name of Angelica spp., especially A. gigas and A. sinensis which are commonly misused in herbal markets. X-ray fluorescence spectrometry and electronic nose have been also applied as nondestructive methods to discriminate A. gigas from A. sinensis according to their specific properties.

The Determination of Rare Earth Oxides by X-Ray Fluorescence Spectrometry Using Empirical Coefficient Method (실험계수법을 이용한 희토류산화물의 X-선 형광분광분석)

  • Young Man Kim;Beom Suk Choi;Sun Tae Kim;Chong Wook Lee
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.1
    • /
    • pp.64-70
    • /
    • 1987
  • Rare earth elements including Y and Th in the monazite were separated and determined by X-ray fluorescence spectrometry. The matrix effects among the rare earth elements were simultaneously corrected by means of empirical coefficient method. The values of the coefficients were quite dependent on the number of the standards. However, the different set of coefficients led to the same results. The analytical results corrected by the present method agreed with those by the inductively coupled plasma spectrometry.

  • PDF

Manjang Cave of Twinrock Composition obtained by Fundamen Parameter Method in X-Ray Fluorescence Spectrometry (Fundamental Parameter 법에 의한 만장굴 용암 석주의 형광X선분석)

  • SAWA, ISAO
    • Journal of the Speleological Society of Korea
    • /
    • v.21 no.22
    • /
    • pp.17-56
    • /
    • 1990
  • Cheju Island, which was formed by volcanic activity, is an oval in its shape with the major axis of 80km and the minor axis of 40km. The island holds in its heart Mt. Hanla rising 1,950m above the sea. Petrological study of this volcanic island has been made actively by Sang-Man Lee, Chong-Kwan won and Moon-Won Lee. The chronological measurements of the island by Chong-Kwan Won and Moon-Won Lee showed that it is composed of Sanbangsan trachytes and Backlokdam trachytes(25,000 year ago). These reports are based on the chemical analysis and the rediometric chronological measurements on the ground. However, there has been no reports about the inside of caves. We made an (composition) analysis of the inside of Manjang Cave by the fundamental parameter method in X-ray fluorescence spectrometry. The fundamental parameter method in X-ray fluorescence spectrometry is nondestructive analysis, and it enables us to make the values processed by a computer. The results obtained by this methods are as follows : SiO$_2$(49%), $Al_2$O$_3$(17%), Fe$_2$O$_3$(13%), CaO(8.1%), MgO(5.5%), Na$_2$O(3.6%), TiO$_2$(2.1%), $K_2$O(0.86%), P$_2$O$_{5}$(0.28%), and MnO(0.20%), respectively. The data obtained by the fundamental parameter method in X-ray fluorescence was compared with the data provided by Chong-Kwan and Moon-Won Lee. Our measurement was made by K-Ar-method in cooperation with T.ITAYA. The samples are of 30,000~420,000 year ago. The composition of the values of our underground analysis with the existing values obtained by the analyses on the ground produced new data about Cheju volcanic island.d.

  • PDF

Development of Monoenergetic Photon Source in the Energe Range below 100 keV by the X-ray Fluorescence Method (형광 X 선을 이용한 100 KeV 이하의 에너지 영역에서의 단색 Photon 선원개발에 관한 연구)

  • Lee, Youn-Myoung;Lee, Kun-Jai;Hah, Suck-Ho;Hwang, Sun-Tae;Lee, Kyung-Ju
    • Journal of Radiation Protection and Research
    • /
    • v.10 no.1
    • /
    • pp.14-28
    • /
    • 1985
  • The development of mono energetic photon sources using $K_{\alpha}$ fluorescence X-ray of pure material was carried out in the energy range below 100 keV. The monoenergetic photons are very useful in the calibration of the radiation measuring instruments and can be produced as the $K_{\alpha}$ fluorescence X-ray by irradiating the bremsstrahlung to the thin pure metal foils called ‘radiators’. In this experiment, several radiators such as $_{47}Ag,\;_{50}Sn,\;_{68}Er,\;_{70}Yb,\;and\;_{82}Pb$ provide the wide monoenergetic photon energy ranging from 20 keV to 80 keV. By the spectrometry with HpGe LEPS, spectral purity factors which measure the monochrometicity for the $K_{\alpha}$ fluorescence X-ray, were determined as $0.64{\sim}0.94$. Dosimetry for the purpose of the determination of the exposure rate with a 600cc thin window ionization chamber, which was calibrated by the standard free-air ionization chamber, was performed. Exposure rates ranging $8.3{\sim}232.5mR/h$ was obtained according to the $K_{\alpha}$ fluorescence X-ray energy for each radiator.

  • PDF

Discrimination of Geographic Origin by Trace Elements Contents in Rehmannia Radix Preparat using X-ray Fluorescence Analysis (X-선 형광 분석방법을 이용한 숙지황의 무기원소 함량분석과 지리적 특성 규명)

  • Bae, Hey-Ree;Lee, Si-Kyung;Whang, In-Jae;Kang, Jeong-Mi;Lee, Jin-Ho;Kim, Jeong-Han
    • Journal of Applied Biological Chemistry
    • /
    • v.58 no.4
    • /
    • pp.345-348
    • /
    • 2015
  • Dried Rehmannia Radix Preparat, produced in different geographic origins of Korea and China, were investigated for the trace element contents using X-ray fluorescence spectrometry. When the estimated data for 35 kind of elements including K, P, S, Cl, Si, Al, Fe, Sn, etc on 143 samples were analyzed by canonical discrimination technique, the average classification correct rate was 92.3% and the significance was less than 0.0001. In case of reducing the number of elements for statistic analysis from 35 to 8 and to 3, the correct rates were also reduced to 88.1% and to 84.6%. The correct rate for Chinese samples ranged from 94.6-96.0%, while those for Korean ranged from 72.5-89.9%.

The Contamination of Sventoji River Bottom Sediments by Heavy Metals in Ukmerge, Lithuania

  • Valskys, Vaidotas;Motiejunas, Mindaugas;Ignatavicius, Gytautas;Sinkevicius, Stanislovas
    • Journal of Environmental Science International
    • /
    • v.25 no.1
    • /
    • pp.1-10
    • /
    • 2016
  • Bottom sediment pollution with heavy metals of the Sventoji River in Ukmerge, Lithuania using X-ray fluorescence spectrometry is analyzed in this article. During the research, qualitative and quantitative parameters of heavy metal concentrations and their distribution were investigated. This article presents obtained results of study, where bottom sediment samples were examined from both shores of the river of Sventoji. During this research, received data was treated using GIS software, which helped to interpolate the data of concentrations into the research polygon of the river. GIS software also helped to evaluate the urban runoff influence to the bottom sediment quality and exclude sources of pollution. The runoff dischargers which transport surface wastewater to the river were registered before sampling. At the mouth of streams, flowing into the river of Sventoji, additional samples were taken. After comprehensive river bottom sediment research there is a possibility to assess the extent of anthropogenic activity and its impact on the river ecosystem and human health.

A Study on the Correction of Spectral Line Overlaps for the Determination of Rare Earth Elements by X-Ray Fluorescence Spectrometry (X-선 형광분광법에 의한 희토류원소 분석에서 스펙트럼선 겹침 방해의 보정에 관한 연구)

  • Young-Man Kim;Young-Sang Kim;Yoon-Chang Park;Chong-Wook Lee
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.6
    • /
    • pp.538-547
    • /
    • 1986
  • The 8 rare earth elements were determined in the monazite concentrates by X-ray fluorescence spectrometry. The spectral line overlapping interferences from the other elements were investigated and the correction methods of interferences were studied using line overlap coefficients. The coefficients were calculated from the ratios of the intensities measured at the diffracted angle (2${\theta}$) of the analytical lines of other elements to the intensity of pure rare earth oxide. The coefficients were used to correct the line overlaps by a regression analysis. The linearities of calibration curves from the corrected intensities were remarkably improved, and their standard deviations were decreased. The analytical results agreed with that of the inductively coupled plasma(ICP) spectrometry within an allowable error range.

  • PDF

Low-level Determinations of Uranium and Thorium in Geologic Samples by X-ray Fluorescence (x-선 형광분석기톨 이용한 지질시료 중 우라늄과 토륨의 미량분석)

  • Park, Yong Joon;Kim, Jung Suk;Choi, Kwang Soon;Suh, Moo Yul
    • Analytical Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.20-25
    • /
    • 1996
  • Trace levels of uranium and thorium in geologic samples are determined rapidly by a direct wavelength-dispersive X-ray fluorescence method. Relative intensity of scattered tube radiation was used as an internal standard to compensate for variations in instrumental operating characteristics. U and Th can be determined within a precision of ${\pm}10%$ and accuracy of ${\pm}15%$ or less with measuring times of 50 seconds for Th and 400 seconds for U, respectively. The results of XRF analysis were in good agreement with those of other methods such as nutron activation analysis and inductively coupled plasma atomic emission spectrometry.

  • PDF

A study on development of CRM by means of XRF analysis for fine ceramic ($BaTiO_3$) (티탄산바륨 소재의 XRF 분석용 CRM 개발에 관한 연구)

  • Kim, Young Man;Jeong, Chan Yee;Lim, Chang Ho;Song, Taek Yong;Lee, Dong Soo
    • Analytical Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.382-391
    • /
    • 1996
  • In this study, 12 different chemical species of fine ceramic($BaTiO_3$) were synthesized as the standard materials for the fast and accurate measurements of X-ray fluorescence spectrometry. Samples were diluted to sixteen times with the filling compound ($Li_2B_4O_7+LiBO_2$) in order to remove the matrix effect, and to get the convenient storage and homogeneity of ingredients. The matrix effects among the ingredients were corrected by the empirical coefficient method based on the Lucas-Tooth and Price model. The standard curve on 12 standard materials containing 15 elements were obtained by using X-ray fluorescence spectrometry at three different laboratories. The correlation factors of BaO, PbO, SrO, $Fe_2O_3$, $La_2O_3$, $SnO_2$, ZnO, $ZrO_2$, CaO indicated the relati vely good agreement over 0.995 among the three different laboratories. $SiO_2$ and $Al_2O_3$ showed the poor linearity because of their low fluorescence intensities.

  • PDF