• Title/Summary/Keyword: X-ray computed

Search Result 799, Processing Time 0.026 seconds

Improvement of Pneumonia in a Patient with Non-Small Cell Lung Cancer Treated with Herbal Medicine after Cessation of Antibiotics - a Case Report

  • Song, Si Yeon;Jeon, Hyeonjin;Lee, Sookyung
    • The Journal of Korean Medicine
    • /
    • v.38 no.2
    • /
    • pp.78-84
    • /
    • 2017
  • A 73-year-old non-small cell lung cancer (NSCLC) patient admitted due to cough, sputum, and dyspnea, aggravated a week ago. She was diagnosed as pneumonia based on the assessment of inflammation markers, chest X-ray and sputum culture. Computed tomography (CT) scan was conducted to exclude malignant tumor metastasis. At the initiation of treatment, considering underlying disease and inflammation marker level, herbal medicine and antibiotics were concurrently used and antibiotics had been discontinued after 10days. Using the monotherapy of herbal medicine in the next 6 days, chest X-ray showed remarkably decreased infiltration in right middle lung and right lower lung. This case represented additional improvement of chest X-ray when treated only with herb medicine after termination of antibiotic therapy and demonstrated the possibility of applying herbal medicine in patients with limited use of antibiotics.

On the Development of Digital Radiography Detectors: A Review

  • Kim, Ho-Kyung;Cunningham, Ian Alexander;Yin, Zhye;Cho, Gyu-Seong
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.4
    • /
    • pp.86-100
    • /
    • 2008
  • This article reviews the development of flat-panel detectors for digital radiography based on amorphous materials, Important design parameters and developments are described for the two main components of flat-panel detectors: the X-ray converter and the readout pixel array. This article also introduces the advanced development concepts of new detectors. In addition, the cascaded linear systems method is reviewed because it is a very powerful tool for improving the design and assessment of X-ray imaging detector systems.

A Study on the Fast Image Reconstruction Algorithm for Spiral CT (Spiral CT의 고속 영상재구성 알고리즘에 관한 연구)

  • Heo, Chang-Won;Jin, Seung-Oh;Lee, Jae-Duck;Huh, Young
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3207-3209
    • /
    • 2000
  • X-ray CT(Computed Tomography) has been a good modality for non-invasive diagnosis and recently, Conventional CT has been replaced rapidly with Spiral CT in recent. In X-ray CT, spiral scanning has various advantages such as better image quality, reduced scan time (in a single breath-hold), a lower x-ray dose. But, it requires very fast and high performance image processing system to reconstruct slice images from spiral scanning. This paper describes the fast image reconstruction techniques with filtered back projection from the viewpoints of fast algorithm as well as hardware implementation for real-time imaging.

  • PDF

The accuracy of the imaging reformation of cone beam computed tomography for the assessment of bone defect healing (골결손부 치유과정에서 cone beam형 전산화단층영상의 정확도)

  • Kang, Ho-Duk;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.37 no.2
    • /
    • pp.69-77
    • /
    • 2007
  • Purpose: To evaluate the accuracy of the imaging reformation of cone beam computed tomography for the assessment of bone defect healing in rat model. Materials and Methods: Sprague-Dawley strain rats weighing about 350 gms were selected. Then critical size bone defects were done at parietal bone with implantation of collagen sponge. The rats were divided into seven groups of 3 days, 1 week, 2 weeks, 3 weeks, 4 weeks, 6 weeks, and 8 weeks. The healing of surgical defect was assessed by multi planar reconstruction (MPR) images and three-dimensional (3-D) images of cone beam computed tomography, compared with soft X-ray radiograph and histopathologic examination. Results: MPR images and 3-D images showed similar reformation of the healing amount at 3 days, 1 week, 2 weeks, and 8 weeks, however, lower reformation at 3 weeks, 4 weeks, and 6 weeks. According to imaging-based methodologies, MPR image revealed similar reformation of the healing amount than 3-D images compare with soft X-ray image. Among the four threshold values for 3-D images, 400-500 HU revealed similar reformation of the healing amount. Histopathologic examination confirmed the newly formed trabeculation correspond with imaging-based methologies. Conclusion: MPR images revealed higher accuracy of the imaging reformation of cone beam computed tomography and cone beam computed tomography is a clinically useful diagnostic tool for the assessment of bone defect healing.

  • PDF

Comparison of Echocardiography and Computed Tomography on Cardiac Wall Thickness and Internal Dimension Size of Left Ventricle in Normal Adults (정상 성인의 좌심실 벽두께와 내강 크기에 대한 심초음파영상과 전산화단층영상의 비교)

  • Ji, Myeong-Hoon;Kim, Seoung-Hwan;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.545-552
    • /
    • 2018
  • The purpose of this study was evaluated the relationship between echocardiography and cardiac computed tomography in normal adults by visual assessment, and evaluated the effective doses of cardiac computed tomography. The subjects were 100 normal patients who visited two general hospitals in Chungnam, from January 1 to May 30, 2018. We obtained images by using these modalities and evaluated the wall thickness and internal dimension of the Left Ventricle with visual assessment. To evaluate the appropriateness of the visual evaluation, two evaluators who were trained for one week were measured and the agreement between the evaluators were verified by statistical analysis. The effective doses of computed tomography were evaluated using the dose length product. As a result, there was a high correlation between the two modalities. The agreement between the two visual evaluator were also highly agreed. The mean X-ray dose of the subjects was $11.1{\pm}3.1mSv$. Although the purpose of imaging is somewhat different in the clinical setting, echocardiography could achieve the same results as radiation-invasive computed tomography. It is thought that utilization will become even larger.

CUDA-based Fast DRR Generation for Analysis of Medical Images (의료영상 분석을 위한 CUDA 기반의 고속 DRR 생성 기법)

  • Yang, Sang-Wook;Choi, Young;Koo, Seung-Bum
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.4
    • /
    • pp.285-291
    • /
    • 2011
  • A pose estimation process from medical images is calculating locations and orientations of objects obtained from Computed Tomography (CT) volume data utilizing X-ray images from two directions. In this process, digitally reconstructed radiograph (DRR) images of spatially transformed objects are generated and compared to X-ray images repeatedly until reasonable transformation matrices of the objects are found. The DRR generation and image comparison take majority of the total time for this pose estimation. In this paper, a fast DRR generation technique based on GPU parallel computing is introduced. A volume ray-casting algorithm is explained with brief vector operations and a parallelization technique of the algorithm using Compute Unified Device Architecture (CUDA) is discussed. This paper also presents the implementation results and time measurements comparing to those from pure-CPU implementation and open source toolkit.

Average Glandular Dose In Mammography

  • Kim, K.H.;Ryu, Y.C.;Oh, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.319-321
    • /
    • 2004
  • The average glandular dose (AGD) is determined by the breast entrance skin exposure, x-ray tube target material, beam quality (half-value layer), breast thickness, and breast composition. Almost breast cancer always arises in glandular breast tissue. As a result, the average radiation absorbed dose to glandular tissue is the preferred measure of the radiation risk associated with mammography. If the normalized average glandular dose is known, the average glandular dose can be computed from the product of the normalized average glandular dose and breast entrance skin exposure. In this study, AGD was calculated by the breast thickness and various x-ray energy (HVL) in 50% glandular 50% adipose breast by Mo.-Rh. assembly. AGD is 84 mrad in compressed 5 cm breast. These results show that as increasing the breast thickness, dose also increases. But as increasing the x-ray tube voltage, dose decreases because of high penetrating ratio through the object. But high tube voltage is reducing the subject contrast. From this result, we have to consider the trade-off between subject contrast of image and dose to the patient and choose proper x-ray energy range.

  • PDF

Evaluation of Pore Size Distribution of Berea Sandstone using X-ray Computed Tomography (X-ray CT를 이용한 베레아 사암의 공극크기분포 산정)

  • Kim, Kwang Yeom;Kim, Kyeongmin
    • The Journal of Engineering Geology
    • /
    • v.24 no.3
    • /
    • pp.353-362
    • /
    • 2014
  • Pore structures in porous rock play an important role in hydraulic & mechanical behaviour of rock. Porosity, size distribution and orientation of pores represent the characteristics of pore structures of porous rock. While effective porosity can be measured easily by conventional experiment, pore size distribution is hard to be quantified due to the lack of corresponding experiment. We assessed pore size distribution of Berea sandstone using X-ray CT image based analysis combined with associated images processing, i.e., image filtering, binarization and skeletonization subsequently followed by the assessment of local thickness and star chord length. The aim of this study is to propose a new and effective way to evaluate pore structures of porous rock using X-ray CT based analysis for pore size distribution.

Dynamically Collimated CT Scan and Image Reconstruction of Convex Region-of-Interest (동적 시준을 이용한 CT 촬영과 볼록한 관심영역의 영상재구성)

  • Jin, Seung Oh;Kwon, Oh-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.151-159
    • /
    • 2014
  • Computed tomography (CT) is one of the most widely used medical imaging modality. However, substantial x-ray dose exposed to the human subject during the CT scan is a great concern. Region-of-interest (ROI) CT is considered to be a possible solution for its potential to reduce the x-ray dose to the human subject. In most of ROI-CT scans, the ROI is set to a circular shape whose diameter is often considerably smaller than the full field-of-view (FOV). However, an arbitrarily shaped ROI is very desirable to reduce the x-ray dose more than the circularly shaped ROI can do. We propose a new method to make a non-circular convex-shaped ROI along with the image reconstruction method. To make a ROI with an arbitrary convex shape, dynamic collimations are necessary to minimize the x-ray dose at each angle of view. In addition to the dynamic collimation, we get the ROI projection data with slightly lower sampling rate in the view direction to further reduce the x-ray dose. We reconstruct images from the ROI projection data in the compressed sensing (CS) framework assisted by the exterior projection data acquired from the pilot scan to set the ROI. To validate the proposed method, we used the experimental micro-CT projection data after truncating them to simulate the dynamic collimation. The reconstructed ROI images showed little errors as compared to the images reconstructed from the full-FOV scan data as well as little artifacts inside the ROI. We expect the proposed method can significantly reduce the x-ray dose in CT scans if the dynamic collimation is realized in real CT machines.

Development of Triaxial Cells Operable with In Situ X-ray CT for Hydro-Mechanical Laboratory Testing of Rocks (원위치 X-ray CT 촬영이 가능한 암석의 수리-역학 실험용 삼축셀 개발)

  • Zhuang, Li;Yeom, Sun;Shin, Hyu-Soung
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.9
    • /
    • pp.45-55
    • /
    • 2020
  • X-ray computed tomography (CT) is very useful for the quantitative evaluation of internal structures, particularly defects in rock samples, such as pores and fractures. In situ CT allows 3D imaging of a sample subjected to various external treatments such as loading and therefore enables observation of changes that occur during the loading process. We reviewed state-of-the-art of in situ CT applications for geomaterials. Two triaxial cells made using relatively low density but high strength materials were developed aimed at in situ CT scanning during hydro-mechanical laboratory testing of rocks. Preliminary results for in situ CT imaging of granite and sandstone samples with diameters ranging from 25 mm to 50 mm show a resolution range of 34~105 ㎛ per pixel pitch, indicating the feasibility of in situ CT observations for internal structural changes in rocks at the micrometer scale. Potassium iodide solution was found to improve the image contrast, and can be used as an injection fluid for hydro-mechanical testing combined with in situ CT scanning.