• Title/Summary/Keyword: X-ray computed

Search Result 799, Processing Time 0.033 seconds

Contribution of Scattered X Rays to Signal Imaging with Anti-scatter Grids

  • Maeda, Koji;Arimura, Hidetaka;Morikawa, Kaoru;Kanamori, Hitoshi;Matsumoto, Masao
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.404-406
    • /
    • 2002
  • We have investigated the contribution of the scattered x rays to the signal imaging in the radiographs acquired with anti-scatter grids of several grid ratios by separating the line spread functions (LSFs) derived from the signal edge image into the primary and the scatter components. By using a 1.0-mm lead plate in the scattering material, the blurred signal edge images were acquired by use of an imaging plate at a tube voltage of 80 kV with the anti-scatter grids of grid ratios for 5:1, 6:1, 8:1, 10:1 and 12:1. The edge profiles of the signal images were scanned and those in relative exposure were differentiated to obtain the LSFs. To investigate the contribution of the scattered x rays to the signal imaging, we proposed a method for separating the LSFs derived from the signal images into the primary and the scatter components, where the scatter component was approximated with exponential function. Our basic approach is to separate the area of the LSFs by ratios of the scattered x-ray exposure to the primary x-ray exposure, which were obtained for the grid ratios by use of a lead disk method. The LSFs and the two components were Fourier transformed to obtain the modulation transfer functions (MTFs) and their two components. As the result, we found that, by using the anti-scatter grids, the scattered x rays were reduced, but the shape of the LSFs of the scatter component hardly changed. The contributions of the scatter component to the MTFs were not negligible (more than 10 %) for spatial frequencies lower than about 1.0 mm$\^$-l/ and that was greater as the grid ratio decreasing. On the other hand, for higher frequencies, the primary component was dominant compared with the scatter component.

  • PDF

Numerical analysis of the thermal behaviors of cellular concrete

  • She, Wei;Zhao, Guotang;Yang, Guotao;Jiang, Jinyang;Cao, Xiaoyu;Du, Yi
    • Computers and Concrete
    • /
    • v.18 no.3
    • /
    • pp.319-336
    • /
    • 2016
  • In this study, both two- and three-dimensional (2D and 3D) finite-volume-based models were developed to analyze the heat transfer mechanisms through the porous structures of cellular concretes under steady-state heat transfer conditions and to investigate the differences between the 2D and 3D modeling results. The 2D and 3D reconstructed pore networks were generated from the microstructural information measured by 3D images captured by X-ray computerized tomography (X-CT). The computed effective thermal conductivities based on the 2D and 3D calculations performed on the reconstructed porous structures were found to be nearly identical to those evaluated from the 2D cross-sectional images and the 3D X-CT images, respectively. In addition, the 3D computed effective thermal conductivity was found to agree better with the measured values, in comparison with the 2D reconstruction and real cross-sectional images. Finally, the thermal conductivities computed for different reconstructed porous 3D structures of cellular concretes were compared with those obtained from 2D computations performed on 2D reconstructed structures. This comparison revealed the differences between 2D and 3D image-based modeling. A correlation was thus derived between the results of the 3D and 2D models.

The location of midfacial landmarks according to the method of establishing the midsagittal reference plane in three-dimensional computed tomography analysis of facial asymmetry

  • Kim, Min Sun;Lee, Eun Joo;Song, In Ja;Lee, Jae-Seo;Kang, Byung-Cheol;Yoon, Suk-Ja
    • Imaging Science in Dentistry
    • /
    • v.45 no.4
    • /
    • pp.227-232
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the influence of methods of establishing the midsagittal reference plane (MRP) on the locations of midfacial landmarks in the three-dimensional computed tomography (CT) analysis of facial asymmetry. Materials and Methods: A total of 24 patients (12 male and 12 female; mean age, 22.5 years; age range, 18.2-29.7 years) with facial asymmetry were included in this study. The MRP was established using two different methods on each patient's CT image. The x-coordinates of four midfacial landmarks (the menton, nasion, upper incisor, and lower incisor) were obtained by measuring the distance and direction of the landmarks from the MRP, and the two methods were compared statistically. The direction of deviation and the severity of asymmetry found using each method were also compared. Results: The x-coordinates of the four anatomic landmarks all showed a statistically significant difference between the two methods of establishing the MRP. For the nasion and lower incisor, six patients (25.0%) showed a change in the direction of deviation. The severity of asymmetry also changed in 16 patients (66.7%). Conclusion: The results of this study suggest that the locations of midfacial landmarks change significantly according to the method used to establish the MRP.

Quantitative Analysis of Spatial Resolution for the Influence of the Focus Size and Digital Image Post-Processing on the Computed Radiography (CR(Computed Radiography)에서 초점 크기와 디지털영상후처리에 따른 공간분해능의 정량적 분석)

  • Seoung, Youl-Hun
    • Journal of Digital Convergence
    • /
    • v.12 no.11
    • /
    • pp.407-414
    • /
    • 2014
  • The aim of the present study was to carry out quantitative analysis of spatial resolution for the influence of the focus size and digital image post-processing on the Computed Radiography (CR). The modulation transfer functions of an edge measuring method (MTF) was used for the evaluation of the spatial resolution. The focus size of X-ray tube was used the small focus (0.6 mm) and the large focus (1.2 mm). We evaluated the 50% and 10% of MTF for the enhancement of edge and contrast by using multi-scale image contrast amplification (MUSICA) in digital image post-processing. As a results, the edge enhancement than the contrast enhancement were significantly higher the spatial resolution of MTF 50% in all focus. Also the spatial resolution of the obtained images in a large focus were improved by digital image processing. In conclusion, the results of this study should serve as a basic data for obtain the high resolution clinical images, such as skeletal and chest images on the CR.

Primary intraosseous carcinoma occurring in the maxilla (상악골에 발생한 원발성 골내암종)

  • Kim Mi-Ja
    • Imaging Science in Dentistry
    • /
    • v.34 no.1
    • /
    • pp.49-54
    • /
    • 2004
  • Primary intraosseous carcinoma (PIOC) is a rare odontogenic carcinoma defined as a squamous cell carcinoma arising within a jaw having no initial connection with the oral mucosa, and presumably developing from residues of the odontogenic epithelium. A 56-year-old patient who complained of delayed healing after extraction of upper left central incisor visited our department. The conventional radiographs showed a bony destructive lesion with ill-defined margin and moth-eaten appearance. On the computed tomographic images, the lesion perforated the labial cortex of alveloar bone, elevated the left nasal floor superiorly, and perforated partially both nasal floor. The magnetic resonance images showed low signal intensity at T2 and Tl weighted images at the area and adjacent soft tissue. Histologically, there were irregular epithelial islands with cell atypia, nuclear hyperchromatism, pleomorphism, atypical mitosis. The final diagnosis was PIOC.

  • PDF

Cerebral Toxoplasmosis Combined with Disseminated Tuberculosis

  • Hwang, Eui-Ho;Ahn, Poong-Gi;Lee, Dong-Min;Kim, Hyeok-Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.5
    • /
    • pp.316-319
    • /
    • 2012
  • A 24-year-old man presented with mental change, fever, abdominal pain, tenderness and palpable mass on the lower abdomen. He was a non-Korean engineer and did not accompany a legal guardian, so medical history taking was difficult due to his mental status. Brain magnetic resonance imaging showed multiple rim-enhanced lesions of the brain, and abdominal computed tomography showed huge paraspinal abscess. Chest X-ray and computed tomography showed poorly defined nodular opacities. We initially thought that this patient was infected with toxoplasmosis with typical cerebral image finding and immunoglobulin laboratory finding of cerebrospinal fluid and serum study. The abdominal abscess was confirmed as tuberculosis through the pathologic finding of caseous necrosis. We used anti-tuberculosis medication and anti-toxoplasmosis medication for almost 4 months, and then his clinical state and radiological findings were considerably improved.

Diagnosis and Treatment of misdiagnosed odontogenic cutaneous sinus tract : a Case report (오진된 치성 피부 누공의 진단과 치료)

  • Kim, Sung-Joon;Kahm, Se-Hoon
    • The Journal of the Korean dental association
    • /
    • v.52 no.6
    • /
    • pp.363-369
    • /
    • 2014
  • The cutaneous sinus tract is an uncommon disease. It is difficult to diagnose exactly of odontogenic cutaneous sinus tract for dentists or dermatologists except experienced clinicians or previously known clinicians. Many patients may be treated with repeated surgical excisions, biopsies, and antibiotic medications, but most of them could be frustrated with the recurrence of disease. There are several methods for diagnosis of odontogenic cutaneous sinus tract - such as GP cone tracing, conventional computed tomography(CT), periapical x-ray imaging, and cone beam computed tomography(CBCT). This case report describes the diagnosis and treatment of odontogenic cutaneous sinus tract that referred from medical doctors.

개인용 컴퓨터를 이용한 뇌 합성영상에 대한 재구성

  • Min, Hyeong-Gi;Nam, Sang-Hui
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.3 no.1
    • /
    • pp.110-118
    • /
    • 1997
  • Recently, to make a diagnosis of the patient different X-Ray examinations are used. To name a few, Computed Tomography(CT). Magnetic Resonance Image(MRI) Single Photon Emission Computed Tomography(SPET) and Positron Emission Tomography(PET). But diagnosticians face difficulties sometimes when they make a diagnosis with images from those examinations. One of the problem is whether the Lesions of the patient is captured in the image correctly. Another one is whether the images are taken with same angle. in this paper, a study 9 on the method to obtain the hybrid image from the different images to different examinations. The procedure done in this paper is described as future study. Although small errors in position between images would occurred, this method more useful as it does not make patients in convenient. To reconstruct a image, some images are scanned by scanner and stored to personal computer for further image processing with Aldus photostyler program. The method to generate a sharpened image are also described.

  • PDF

Comprehensive understanding of atrial septal defects by imaging studies for successful transcatheter closure

  • Song, Jinyoung
    • Clinical and Experimental Pediatrics
    • /
    • v.57 no.7
    • /
    • pp.297-303
    • /
    • 2014
  • Transcatheter closure of atrial septal defects has become a popular procedure. The availability of a preprocedural imaging study is crucial for a safe and successful closure. Both the anatomy and morphology of the defect should be precisely evaluated before the procedure. Three-dimensional (3D) echocardiography and cardiac computed tomography are helpful for understanding the morphology of a defect, which is important because different defect morphologies could variously impact the results. During the procedure, real-time 3D echocardiography can be used to guide an accurate closure. The safety and efficiency of transcatheter closures of atrial septal defects could be improved through the use of detailed imaging studies.

Accuracy of Preoperative Computed Tomography in Comparison with Histopathologic Findings in Staging of Lung Cancer (폐암의 병기결정시 임파절의 조직학적 소견과 전산화단층활영의 정확도에 관한 고찰)

  • 박기진;김대영
    • Journal of Chest Surgery
    • /
    • v.29 no.1
    • /
    • pp.52-58
    • /
    • 1996
  • Sixty six patients who were operated as lung cancer during the period from Mar. 1991 to Sep. 1993 at the department of Thoracic and cardiovascular surgery, were reviewed retrospectively and the accuracy of regional lymph node in preoperative CT were compared with histopathologlc report obtained from operation. The age ranged from 30 to 72 years old (mean age : 56.5), and 51 patients were male and 15 patients were female. The author analysed the true positive, true negative, false positive and false negative and sensitivity, specificity, positive predictive index, negative predictive index and accuracy of each nodes. The result is that there were differences between seven nodal groups in specificity, sensitivity, positive predictive Index, negative predictive index and accuracy. The range of each nodal group is from 81.7 to 98.3% The nodes of the most poor accuracy are aortopulmonary area and hilar area.

  • PDF