• Title/Summary/Keyword: X-ray Tube

Search Result 516, Processing Time 0.021 seconds

The Characteristic of Temperature and Dose Distribution of intra oral X-ray Tube (강내형 X선 튜브 온도 및 선량 분포 특성)

  • Cho, Sungho;Lee, Rena
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.262-266
    • /
    • 2013
  • A new concept of periapical radiography, intra oral x-ray tube and detector system is introduced. It is new system that a miniature x-ray tube is inserted into mouse and it acquired digital image using external detector. In this study, we have investigated temperature and dose distribution of insertional x-ray tube for periapical radiography. To analyze temperature characteristic of x-ray tube, we attached the thermocouple to surface of x-ray tube and we measured the temperature according to distance. Also, we measured the dose distribution of a miniature x-ray tube according to distance. As a result, temperature was constant to $27^{\circ}C$ over 2mm without cooling system, dose distribution of x-ray tube was 3.14 and 1.84mGy in 3 and 5cm, respectively. Therefore, the proposed x-ray system works in lower dose than conventional dental x-ray system. Thus, it is considered that new concept of system will have a significant effect on medical imaging technology.

Effect of the amount of battery charge on tube voltage in different hand-held dental x-ray systems

  • Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.42 no.1
    • /
    • pp.1-4
    • /
    • 2012
  • Purpose : Hand-held dental x-ray system is a self contained x-ray machine designed to perform intraoral radiography with one or two hands. The issue about its usage as general dental radiography is still in dispute. The aim of the present study was to assess the relationship between the amount of battery charge and the tube voltage in different handheld dental x-ray systems. Materials and Methods : Seven hand-held dental x-ray units were used for the study. Tube voltage was measured with Unfors ThinX RAD (Unfors Instruments AB, Billdal, Sweden) for 3 consecutive exposures at the different amount of battery charge of each unit. The average and the deviation percentage of measured kV from indicated kV of each unit were calculated. Results : Tube voltage of only 1 unit was 70 kV (indicated by manufacturer) and those of the others were 60 kV. Tube voltage deviation percentage from the indicated kV at the fully charged battery was from 2.5% to -5.5% and from -0.8% to -10.0% at the lowest charged battery. Conclusion : Tube voltages of all units decreased as the residual amount of the battery charge decreased. It is suggested that the performance test for hand-held x-ray system should be performed for the minimum residual charged battery as well as the full charged one. Persistent battery charging is suggested to maintain the proper tube voltage of the hand-held portable x-ray system.

A Study on the Distribution of X-ray according to the Thickness of Soft Tissue in Radiography (X선촬영시(線撮影時) 연부조직(軟部組織) 두께에 따른 선량분포(線量分布)에 관(關)한 연구(硏究))

  • Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.11 no.2
    • /
    • pp.3-15
    • /
    • 1988
  • When X-rays were projected into a patient, there occured the phenomena such as penetration, absorption and scattering etc. The penetrating rays were recorded on films as X-ray image used for diagnosis but scattered rays caused the radiation hazard both to the patient, specialist and technicians. The soft tissue includes many organs which are sensitive to the radiation and in may occupy $40{\sim}50%$ of body weight. Therefore X-rays should be carefully projected to the patient and it is strongly recommended to analyse the distribution of X-rays, when ever the patient is exposed to X-rays. In this study, the distribution of X-ray according to the thickness, the radiation field and the tube voltages (kVp) in soft tissue, the following results were obtained: 1. Total transmitted rays which kept the step with X-ray tube voltage (kVp) increased in proportion to the increasing of X-ray tube voltage. 2. The scattered ray rate in the total transmitted ray was not significantly found with X-ray tube voltage. 3. The affecting factors of the scattered ray rate in total transmitted ray were shown through the radiation field and the thickness. 4. The dose of scattered ray by the angle was observed more in direction of primary ray ($0^{\circ}$) and back scattering ($160^{\circ}$) than in direction of $90^{\circ}$. 5. The more the distance from phantom to the patient should be less distribution of scattered ray.

  • PDF

Influence of X-ray Tube Voltage and Object on X-ray Quality and Dose (X선촬영에 있어서 관전압과 피사체가 선질 및 선량에 미치는 영향의 실험)

  • Huh, Joon;Kim, Chang-Kyun;Kang, Hong-Seok;Kim, Chung-Min
    • Journal of radiological science and technology
    • /
    • v.7 no.1
    • /
    • pp.41-46
    • /
    • 1984
  • Authors investigated an influence of x-ray tube voltage on x-ray quality and dose with using objects of various thickness, and obtained the results as follows: 1. Radiographic effects were influenced by tube voltages and objects. 2. Dose decrement rates hade more influence upon primary-rays than total x-rays at lower tube voltages. 3. The quality of transmitted x-rays was affected by tube voltages and thickness of objects. 4. Scattered-ray contents were proportional to tube voltages with using grid.

  • PDF

Settling time of dental x-ray tube head after positioning (치과용 X-선 관구의 조정시간)

  • Yoon Suk-Ja;Kang Byung-Cheol;Wang Se-Myung;Koh Chang-Sung
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.159-165
    • /
    • 2002
  • Purpose: The aim of this study was to introduce a method of obtaining the oscillation graphs of the dental x-ray tube heads relative to time using an accelerometer. Materials and Methods: An Accelerometer, Piezotron type 8704B25 (Kistler Instrument Co., Amherst, NY, USA) was utilized to measure the horizontal oscillation of the x-ray tube head immediately after positioning the tube head for an intraoral radiograph. The signal from the sensor was transferred to a dynamic signal analyzer, which displayed the magnitude of the acceleration on the Y-axis and time lapse on the X -axis. The horizontal oscillation of the tube head was measured relative to time, and the settling time was also determined on the basis of the acceleration graphs for 6 wall type, 5 floor-fixed type, and 4 mobile type dental x-ray machines. Results : The oscillation graphs showed that tube head movement decreased rapidly over time. The settling time varied with x-ray machine types. Wall-type x-ray machines had a settling time of up to 6 seconds, 5 seconds for fixed floor-types, and 1 I seconds for the mobile-types. Conclusion: Using an accelerometer, we obtained the oscillation graphs of the dental x-ray tube head relative to time. The oscillation graph with time can guide the operator to decide upon the optimum exposure moment after x-ray tube head positioning for better radiographic resolution.

  • PDF

A Study on Radition-Induced Current in Insulating Oil during X-ray Irradiation (방사선(放射線) 조사(照射) 중(中) 절연유(絶緣油)의 유기전류(誘起電流)에 관한 연구(硏究))

  • Kim, Young-Il;Lee, Duck-Chool;Chung, Yon-Tack
    • Journal of radiological science and technology
    • /
    • v.11 no.1
    • /
    • pp.33-41
    • /
    • 1988
  • This study was measured the radiation-induced current - X-ray dose, dose rate, X-ray quality, time, temperature, electric field characteristics and the dependence of gap length in insulating oil under of D.C. Voltage before, during and after X-ray irradiation. The obtained results can be summarized as following. 1. The radiation - induced current is more the dependence of X-ray quality (tube voltage) than quantity (tube current), the dependence of quantity is appeared at the high than low X-.ay tube voltage. 2. The dependence of dose rate is appeared at the more dose rate, and ${\triangle}\;=\;0.64{\sim}0.74$. 3. The higher temperature of insulating oil and X-ray tube voltage (X-ray quality) is increased, at the low electric field, the more radiation-induced current. 4. $G_{eq}-G_{o}(={\triangle}G)$ is increased at the low than high temperature, high than low X-ray quality. 5. The dependence of temperature is appeared before than during X-ray irradiation. 6. The RIC saturation region is appeared at the high than low insulating oil temperature during (1000 V/cm above) than before (4000 V/cm above) X-ray irradiation.

  • PDF

Study on Generator Control for a Small X-Ray Tube (X-선 튜브의 고전압 발생장치 제어에 관한 연구)

  • Lee, Soonhyouk;Ji, Yun-Seo;Choi, Sang Gyu;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.248-254
    • /
    • 2014
  • The purpose of this study is to develope a control system for a small X-ray tube generator and investigate control methods for the X-ray generator. The small X-ray tube was developed for electronic brachytherapy, and thus, the new control method should be investigated, if the small X-ray tube is used for the imaging system. The Axxent S700 X-ray tube and the XF060NZZ485 high voltage generator were used to compose a X-ray imaging system and control board was developed by using AT90CAN128 MCU. The two control methods were investigated after tube voltage was set to 50 kV, one was filament current control method and the other was beam current control method. The former was subdivided into two methods according to the filament heating time, the 5 and the 10 seconds respectively. In the filament current method, the beam current did not rise up to the desired value, if the filament current had not been maintained for at least 10 seconds. The onset filament currents to generate beam current were varied from 1,300 to 1,350 mA and over 5 seconds were needed in order to reach the desired tube current value after beam current was generated. However, in the tube current control method, the beam current reached to the desired value without any time delay with the filament current of 1,500 mA. In this study, we found that the beam current control method was appropriate for the use of small X-ray tube developed for brachytherapy in the X-ray imaging system.

Study of Suitable Angle of Tibia-Foot and X-ray Tube for Navicular in Foot X-ray Examination (족부 X선 검사에서 주상골 관찰에 용이한 Tibia-Foot angle과 X-ray tube 각도에 대한 연구)

  • Moon, Joo-Wan;Han, Jae-Bok;Choi, Nam-Gil
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.39-46
    • /
    • 2018
  • The purpose of this study was to determine suitable angle of Tibia-foot and the X-ray tube for scaphoid in foot X-ray examination. A total of twenty patients(mean age $32.12{\pm}years)$ are participated in this study. In the positions of Foot AP, internal and external oblique, tibia-foot angle was defined as $90^{\circ}$ and $135^{\circ}$, and x-ray tube angle was defined as $0^{\circ}$, $5^{\circ}$, $10^{\circ}$, $15^{\circ}$ and $20^{\circ}$ respectively. The image quality was evaluated with blind test yielding scores ranging from 0 to 5 by the evaluation team consisted of 2 radiogical technologists, 2 radiologists, and 2 orthopedic surgeons. In case of Foot AP position, the degree of overlap between cuneiform and navicular was 3% and the blind test result was 4.89 at tibia-foot angle of $90^{\circ}$ and $15^{\circ}$ X-ray tube angle. When the tibia-foot angle is $135^{\circ}$, the degree of overlap was 5%, also the blind test result was 4.30 at $15^{\circ}$ X-ray tube angle. The degree of overlap and blind test result were 30% and 3.75 respectively at $0^{\circ}$ X-ray tube angle. In case of internal oblique position, at tibia-foot angle of $90^{\circ}$ and $0^{\circ}$ X-ray tube angle, the degree of overlap was 4% and the blind test result was 4.70. The 5% overlapping and highest score as 4.55 were obtained on tibia-foot angle of $135^{\circ}$ and $0^{\circ}$ X-ray tube angle. In case of external oblique position, at tibia-foot angle of $90^{\circ}$ and $15^{\circ}$ X-ray tube angle, the degree of overlap was 4% and the blind test score was 4.85. The 5% overlapping and highest score as 4.75 were obtained on tibia-foot angle of $135^{\circ}$ and $15^{\circ}$ X-ray tube angle. In conclusion, we confirmed suitable angle of tibia-foot and X-ray tube for scaph46oid in foot X-ray examination in this study. These findings will be helpful for us to reading for navicular fracture.

Characteristic Evaluation of Medical X-Ray Using High-Voltage Generator with Inverter System (인버터방식의 고전압 발생장치를 이용한 의료용 X선 기기의 특성평가)

  • Kim, Young-Pyo;Cheon, Min-Woo;Park, Yong-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.1
    • /
    • pp.36-41
    • /
    • 2011
  • Medical X-ray has been brought many changes according to the rapid development of high technology. Especially, for high-voltage generator which is the most important in X-ray generation the traditional way is to use high-voltage electric transformers primarily. However, since it is large and heavy and the ripple rate of DC high-voltage applied to X-ray tube is too big, it has a disadvantage of low X-ray production efficiency. To solve these problems, the studies about high-voltage power supply are now proceeding. At present, the high-voltage generator that generates high-voltage by making high frequency using inverter control circuit consisting of semiconductor device is mainly used. High-voltage generator using inverter has advantages in the diagnosis using X-ray including high performance with short-term use, miniaturization of power supply and ripple reduction. In this study, the X-ray high-voltage device with inverter type using pulse width modulation scheme to the control of tube voltage and tube current was designed and produced. For performance evaluation of produced device, the control signal analysis, irradiation dose change and beam quality depending on the load variation of tube voltage and tube current were evaluated.

A 16kw Rotating Anode type Monoblock X-ray Generator (16kW 회전 Aonde형 모노블럭 X-선 발생장치)

  • Oh, Jun-Yong;Kim, Yuen-Chung;Kim, Hack-Seong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.97-103
    • /
    • 2006
  • This paper designs mono block type with rotating high power radiography x-ray generator and studies 16kW X-ray generator possible to adapt hospital mobile radiography and industrial X-ray equipment and design. This equipment uses rotating anode type x-ray tube at high voltage generator to generate x-ray and adds rotor operating circuit to operate rotor of x-ray tube. The size of high voltage transformer and high voltage generator is minimized by high voltage high frequency inverter has 100kHz switching frequency. Also this paper shows result of x-ray tube voltage and tube current correspond to variable load.