Application of spherical coordinate system to facial asymmetry analysis in mandibular prognathism patients

  • Yoon, Suk-Ja;Wang, Rui-Feng;Hwang, Hyeon-Shik;Kang, Byung-Cheol;Lee, Jae-Seo;Palomo, Juan Martin
    • Imaging Science in Dentistry
    • /
    • 제41권3호
    • /
    • pp.95-100
    • /
    • 2011
  • Purpose : The purpose of this study was to compare asymmetric mandibular prognathism individuals with symmetric mandibular prognathism individuals using a new alternate spherical coordinate system. Materials and Methods : This study consisted of 47 computed tomographic images of patients with mandibular prognathism. The patients were classified into symmetric and asymmetric groups. Mandibular and ramal lines were analyzed using an alternate spherical coordinate system. The length as well as midsagittal and coronal inclination angle of the lines was obtained. The bilateral differences of the spherical coordinates of the facial lines were statistically analyzed in the groups. Results : There were significant differences between the groups in bilateral difference of the length and midsagittal inclination angle of the lines (p<0.05). The bilateral difference of the length and midsagittal inclination angle of the lines has significant correlation with chin deviation (p<0.05). Conclusion : The new alternate spherical coordinate system was able to effectively evaluate facial lines. The bilateral difference of lengths and midsagittal inclination of the facial lines might contribute to the facial asymmetry in mandibular prognathism individuals.

호흡동조전산화단층촬영과 콘빔전산화단층촬영의 팬텀 영상 체적비교 (Comparison of Volumes between Four-Dimensional Computed Tomography and Cone-Beam Computed Tomography Images using Dynamic Phantom)

  • 김성은;원희수;홍주완;장남준;정우현;최병돈
    • 대한방사선치료학회지
    • /
    • 제28권2호
    • /
    • pp.123-130
    • /
    • 2016
  • 목 적 : Computerized imaging reference systems 동적팬텀을이용한 cone-beamcomputed tomography(CBCT) 영상과 four-dimensionalcomputed tomography(4DCT) 영상의 체적을 비교분석 하고자 한다. 대상 및 방법 : 동적팬텀 내에 직경 1, 2, 3 cm 노드를 각각 삽입하고, CT simulator와 TruebeamSTx X-ray Imaging system을 이용하여 4DCT 영상과 CBCT 영상을 얻었다. 4DCT 영상은 maximum intensity projection(MIP), minimum intensity projection(MinIP), 그리고 average intensity projection(AVG)영상으로 재구성 하고 노드의 체적은 Eclipse system의 CT ranger tool로 CT number를 설정하여 측정하였다. 결 과 : CBCT를 기준으로 노드1, 2, 3 cm의 체적을 비교하였을 때 4DCT의 MIP는 0.54~2.33, 5.16~8.06, 9.03~20.11 ml, MinIP는 0.00~1.48, 0.00~8.47, 1.42~24.85 ml, AVG는 0.00~1.17, 0.00~2.19, 0.04~3.35 ml의 차이를 보였다. 결 론 : 노드의 체적을 비교한 결과 CBCT 영상은 4DCT의 AVG 영상과 유사한 것으로 확인되었다.

  • PDF

디지털 검출기에서 샘플링 간격에 따른 MTF의 변화 (Change of MTF for Sampling Interval in Digital Detector)

  • 조형욱;천권수
    • 한국방사선학회논문지
    • /
    • 제8권5호
    • /
    • pp.225-230
    • /
    • 2014
  • 엑스선 의료영상이 디지털 시스템으로 발전함에 따라 의료영상의 평가 방법 또한 디지털 시스템에 맞춰 새롭게 개선되었으며 그 중 MTF(Modulation Transfer Function) 측정법은 Fujita이론에 기초한 에지법으로 ISO에 규정되었다. 에지법의 기초인 Fujita이론은 MTF 측정을 위해 슬릿의 각도를 디지털 검출기의 픽셀 열에 대하여 $1^{\circ}{\sim}2^{\circ}$ 기울여 영상을 획득한 후 LSF를 합성하는 것으로 샘플링 간격은 각도에 따라 크게는 1/54배, 작게는 1/28배 감소하게 된다. 본 연구에서 사용된 장비는 Simens사의 MAMMOMAT Inspiration으로 비정질 셀레늄(amorphous selenium) 기반의 $0.085{\times}0.085mm^2$ 의 픽셀 사이즈를 갖는 검출기를 이용하여 presampling MTF를 측정하였다. 측정 방법은 Fujita의 슬릿법와 동일한 방법인 와이어법를 이용하였으며 측정된 영상에서 얻은 픽셀값을 이용하여 엑셀에서 이산 푸리에 변환을 시행하였다. 실험 결과 Fujita이론 대비 약 3배 이상의 샘플링 간격(sampling interval)의 경우 해상도 평가 지수인 10% MTF에서 약 85% 이하의 정확도를 보였으며 선예도 평가 지수인 50% MTF에서 약 93% 이하의 정확도를 나타내었다. 하지만 샘플링 간격이 Fujita 이론 대비 2배 정도 늘어난 경우는 50%와 10% MTF 모두 96% 이상의 정확도를 가진다는 것을 알 수 있었다.

흰쥐 미세구조 관찰을 위한 Micro-CT 3D 영상의 유용성에 관한 연구 (A Study on the Usefulness of 3D Imaging in Micro-CT for Observing the Microstructure of Mice)

  • 이상호;이종석;임청환;정홍량;채규윤;한범휘;한상현;홍동희;한태종;박성훈;모은희;전홍영
    • 디지털융복합연구
    • /
    • 제12권3호
    • /
    • pp.367-375
    • /
    • 2014
  • 본 연구는 실시간 동적영상(Real-time dynamic image)을 획득할 수 있는 고해상도 엑스선 영상장치인 마이크로 CT 을 이용하여 흰쥐의 미세 혈관구조를 관찰함은 물론 국내 원광 방사선영상 과학연구 센터에서 개발한 마이크로 CT 에 대한 유용성을 알아보고자 한다. 흰쥐 몸 전체의 2D 영상을 얻은 후 MIP(maximum intensity projection), VRT(volume rendering technique)기법을 이용하여 혈관구조의 조영된 3D 영상을 얻을 수 있었고 이 3D 혈관 영상을 머리, 복부, 심장과 몸 전체의 혈관시스템으로 각각 분류하였다.

확산 모형에 의한 고가 의료기기의 수요 확산의 특성분석 및 중장기 수요예측에 관한 연구 (A Study on a Long-term Demand Forecasting and Characterization of Diffusion Process for Medical Equipments based on Diffusion Model)

  • 홍정식;김태구;임달오
    • 보건행정학회지
    • /
    • 제18권4호
    • /
    • pp.85-110
    • /
    • 2008
  • In this study, we explore the long-term demand forecasting of high-price medical equipments based on logistic and Bass diffusion model. We analyze the specific pattern of each equipment's diffusion curve by interpreting the parameter estimates of Bass diffusion model. Our findings are as follows. First, ultrasonic imaging system, CT are in the stage of maturity and so, the future demands of them are not too large. Second, medical image processing unit is between growth stage and maturity stage and so, the demand is expected to increase considerably for two or three years. Third, MRI is in the stage of take-off and Mammmography X-ray system is in the stage of maturity but, estimates of the potential number of adopters based on logistic model is considerably different to that based on Bass diffusion model. It means that additional data for these two equipments should be collected and analyzed to obtain the reliable estimates of their demands. Fourth, medical image processing unit have the largest q value. It means that the word-of-mouth effect is important in the diffusion of this equipment. Fifth, for MRI and Ultrasonic system, q/p values have the relatively large value. It means that collective power has an important role in adopting these two equipments.

국내 의료기관에서 측방두부규격방사선촬영시 임상에서의 촬영조건 및 환자 선량 (Radiographic examination protocol and patient dose in lateral cephalometric radiography in Korea)

  • 최진우
    • Imaging Science in Dentistry
    • /
    • 제40권4호
    • /
    • pp.165-169
    • /
    • 2010
  • Purpose : To survey the radiographic examination protocol for lateral cephalometric radiographic examinations and to measure their patient doses in Korea and to compare the dose according to the size of hospital, the type of image receptor system, and the installation duration. Materials and Methods : The radiographic examination protocols (kVp, mA, and exposure time) for lateral cephalometric radiography were surveyed with 61 cephalometric radiographic equipments and their patient dose-area product (DAP) measured with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for 51 cephalometric radiographic equipments. The radiographic examination protocols and patient doses were compared according to the size of hospital (university dental hospital, dental hospital, and dental clinic), the type of image receptor system (film-based, DR and CR type) and the installation duration, respectively. SPSS 12.0.1 for Windows (SPSS Inc., Chicago, USA) was used for independent t-test and ANOVA test. Results : The average protocols were 77.0 kVp, 12.7 mA, 6.2 second for cephalometric radiography. The average patient dose (DAP) was $128.0mGy\;cm^2$ and 3rd quartile dose (DAP) $161.1mGy\;cm^2$ for cephalometric radiography for adult male. There was no statistically significant difference at average patient DAP according to the size of hospital, the type of image receptor system, and the installation duration, repectively. Conclusion : The average patient dose was $128.0mGy\;cm^2$ and the third quartile patient dose $161.1mGy\;cm^2$ for lateral cephalometric radiography for adult male in Korea.

Is the Frozen Shoulder Classification a Reliable Assessment?

  • Gwark, Ji-Yong;Gahlot, Nitesh;Kam, Mincheol;Park, Hyung Bin
    • Clinics in Shoulder and Elbow
    • /
    • 제21권2호
    • /
    • pp.82-86
    • /
    • 2018
  • Background: Although a common shoulder disease, there are no accepted classification criteria for frozen shoulder (FS). This study therefore aimed to evaluate the accuracy of the conventionally used FS classification system. Methods: Primary FS patients (n=168) who visited our clinic from January 2010 to July 2015 were included in the study. After confirming restrictions of the glenohumeral joint motion and absence of history of systemic disease, trauma, shoulder surgery, shoulder muscle weakness, or specific x-ray abnormalities, the Zuckerman and Rokito's classification was employed for diagnosing primary FS. Following clinical diagnosis, each patient underwent a shoulder magnetic resonance imaging (MRI) and blood tests (lipid profile, glucose, hemoglobin A1c, and thyroid function). Based on the results of the blood tests and MRIs, the patients were reclassified, using the criteria proposed by Zuckerman and Rokito. Results: New diagnoses were ascertained including blood test results (16 patients with diabetes, 43 with thyroid abnormalities, and 149 with dyslipidemia), and MRI revealed intra-articular lesions in 81 patients (48.2%). After re-categorization based on the above findings, only 5 patients (3.0%) were classified having primary FS. The remaining 163 patients (97.0%) had either undiagnosed systemic or intrinsic abnormalities (89 patients), whereas 74 patients had both. Conclusions: These findings demonstrate that most patients clinically diagnosed with primary FS had undiagnosed systemic abnormalities and/or intra-articular pathologies. Therefore, a modification of the Zuckerman and Rokito's classification system for FS may be required to include the frequent combinations, rather than having a separate representation of systemic abnormalities and intrinsic causes.

The Effects of Computer Game Exposure on Musculoskeletal Pathological Symptoms in Adolescents

  • Chae, Woen-Sik;Jung, Jae-Hu
    • 한국운동역학회지
    • /
    • 제28권1호
    • /
    • pp.55-60
    • /
    • 2018
  • Objective: This study aimed to analyze the effects of computer game exposure on pathological musculoskeletal symptoms in adolescents. Method: This study included 10 male junior high school students who used computers less than 3 times a week for 1 hr per day. The subjects were asked to play computer games for 4 hr. Magnetic resonance imaging of the hand and wrist, from the distal radius and ulnar head to the distal phalanges, and radiography of the cervical vertebrae were performed before and after playing computer games. For each dependent variable, a paired t-test was performed to identify significant changes before and after a 4-hr active computer game (p<.05). Results: The horizontal diameters of the flexor tendons in the index and middle fingers were significantly reduced after playing computer games. The horizontal diameters of the flexor tendons of other fingers did not show any significant differences, but there was a tendency toward a decrease after playing computer games. There was no significant change in the cervical lordosis angle before and after playing computer games. However, the cervical lordosis angle was relatively decreased. Conclusion: The results of this study showed that computer game exposure had direct and indirect effects on morphological changes of flexor tendons. In addition, playing computer games for long periods of time can have a negative effect on normal functioning of the musculoskeletal system, with the possible development of abnormalities. However, computer game exposure in adolescents cannot be decisively identified as a factor causing pathological symptoms, based on the results of this study alone. Thus, longterm longitudinal studies on the overall musculoskeletal system are necessary.

소아복부 종괴의 방사선학적 고찰 (Radiologic Evaluation of Intraabdomenal Masses in Childhood)

  • 권혁포;변우목;황미수;김선용;장재천;박복환
    • Journal of Yeungnam Medical Science
    • /
    • 제5권1호
    • /
    • pp.33-42
    • /
    • 1988
  • 최근 5년간의 소아의 복부종괴 23예를 발생빈도, 부위 및 방사선학적 소견을 중심으로 비교분석하여 다음과 같은 결론을 얻었다. 1. 전체 23예중 신경아세포종이 6예로 가장 많았고 그 다음이 Wilms 종양 5예, 담도낭종, 난소종양, 수신종 등의 순위였다. 2. 발생연령별로 분석해 본 결과 6세 이하가 78%(14예)를 차지했고 특히 후복강 종양은 6세 이하에 집중되어 있었다. 3. 부위별로는 후복강 종양이 60%(14예)로 가장 많았다. 4. 방사선학적 소견을 분석하여 본 결과 1) 단순 복부촬영상 신경아세포종의 50%에서 특징적인 석회와 음영을 볼 수 있었고 후복강 종양의 대부분에서 비특이적인 석회화 음영을 볼 수 있었다. 2) 초음파 소견상 저에코, 고에코 또는 혼합에코 등의 종괴 내부성상을 알 수 있었으나 종괴의 정확한 해부학적 위치를 파악할 수 없는 경우가 많았다. 3) 경정맥 신우 조영촬영상 신우신배의 비정상적인 소견과 신장의 전위 소견으로부터 신장내 종양과 신장의 다른 부위의 종양을 구분할 수 있었다. 4) 전산화 단층촬영상 종괴 내부의 성상뿐만 아니라 종괴의 해부학적인 위치, 주위 구조와의 관계, 임파절이나 다른 부위로의 전이유무를 알 수 있었다.

  • PDF

디지털방사선시스템에서 IEC표준을 이용한 방사선 영상 품질의 평가 (Evaluation of Image Quality for Radiographic Positioning using IEC Radiation Quality in the Digital Radiography System)

  • 안현;김창수;김정훈
    • 한국콘텐츠학회논문지
    • /
    • 제15권7호
    • /
    • pp.289-299
    • /
    • 2015
  • 본 연구의 목적은 디지털방사선시스템의 영상 품질을 비교하고 평가함에 있다. 영상의 정량적인 분해능을 나타내는 변조전달함수, 노이즈 특성을 나타내는 잡음력 스펙트럼을 이용하여 영상 품질평가를 하였다. IEC61267 선질을 사용하여 IEC62220-1에서 제시하는 기하학적인 조건과 실제 임상에서 사용되어지는 기하학적인 조건을 사용하여 부가필터 및 그리드, 임상선량을 이용하여 edge 팬텀을 사용하여 MTF값을 측정하였다. Grid, Filter, SID, kVp, mAs에 따른 MTF 결과는 임상조건 100, 180cm 와 IEC62220-1 기하학적인 조건 150cm에서 MTF 공간주파수 측정값은 비슷하게 나타났으며, 오히려 임상조건 100, 180cm에서 공간주파수가 높은 경우도 있었다. NPS 결과는 선량이 증가함에 따라 감소함을 나타내었다. IEC61267 선질을 이용한 영상품질평가에서는 IEC62220-1기하학적인 조건을 이용한 품질평가보다 임상조건 기하학적인 조건을 사용한 영상의 품질이 좋았다. IEC 와 임상조건에서의 MTF와 NPS는 크게 차이가 나지 않았음을 알 수 있었다. 그러므로 향후 IEC 표준에서 제시하는 영상품질 평가보다는 임상 조건을 적용한 영상품질 평가방법을 적용하기 위해서 부가필터사용 유 무, 그리드사용 유 무, SID변화, 선질, 선량 등의 파라메터를 적절히 이용하여 가장 적은 선량으로 공간분해능이 좋고, NPS가 감소하는 방법들을 찾는다면 향후 실제 임상에서 사용되고 있는 디지털방사선시스템을 최적의 품질로 유지할 수 있는 참고 자료로 활용될 수 있을 것으로 사료된다.