Radiation Resistance Evaluation of Thin Film Transistors (박막트랜지스터의 방사선 내구성 평가)

  • Seung Ik Jun;Bong Goo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.625-631
    • /
    • 2023
  • The important requirement of industrial dynamic X-ray detector operating under high tube voltage up to 450 kVp for 24 hours and 7 days is to obtain significantly high radiation resistance. This study presents the radiation resistance characteristics of various thin film transistors (TFTs) with a-Si, poly-Si and IGZO semiconducting layers. IGZO TFT offering dozens of times higher field effect mobility than a-Si TFT was processed with highly hydrogenated plasma in between IGZO semiconducting layer and inter-layered dielectric. The hydrogenated IGZO TFT showed most sustainable radiation resistance up to 10,000Gy accumulated, thus, concluded that it is a sole switching device in X-ray imaging sensor offering dynamic X-ray imaging at high frame rate under extremely severe radiation environment such as automated X-ray inspection.

Implementation and Evaluation of Optimal Dose Control for Portable Detectors with SiPM (SiPM을 통한 휴대용 검출기의 최적 선량 제어에 대한 구현 및 평가)

  • Byung-Wuk Kang;Sun-Kook Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1139-1147
    • /
    • 2023
  • The purpose of this paper is to present and evaluate the performance of a method for controlling the dose for optimal image acquisition while minimizing patient exposure by applying a small-sized Photomultiplier(SiPM) sensor inside a portable detector. Portable detectors have the advantage of being able to quickly access the patient's location for rapid diagnosis, but this mobility comes with the challenge of dose control. This paper presents a method to identify the dose that can have the DQE and optimal image quality of the detector through image evaluation based on IEC62220-1-1, an international standard for X-ray imaging devices, and to identify the optimal dose by matching the ADU of the image and the output of the SiPM Sensor. The Skull AP image was acquired by implementing the detector manufacturer's reference dose. The optimal dose was 342.8 µGy, and the optimal controlled dose was 148.3 µGy, which is 57 % of the manufacturer's reference dose. The Chest AP image was 81.9 µGy and the optimal controlled dose was 27.9 µGy, which is a high dose reduction effect of 66 %. In addition, the two images were analyzed by five radiologists and found to have no clinically significant difference in anatomical delineation.

The Fabrication and Property Evaluation of Poly-crystalline CdTe based Photon Counting X-ray Sensor (다결정 CdTe 기반의 광계수형 X선 센서 제작 및 특성평가)

  • Kang, Sang Sik;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.439-443
    • /
    • 2015
  • An electrical signals of a conventional radiation medical imaging sensor are obtained by charge integration method. In this study, the polycrystalline cadmium telluride(p-CdTe) film was fabricated by a thermal evaporation method for the photon counting sensor development with excellent resolution in low exposure dose. From the fabricated p-CdTe sensor, the physical properties(SEM, XRD) and the electrical properties(leakage current, x-ray sensitivity, SNR) were evaluated. As a result, the leakage current of below $5nA/cm^2$ and $7{\mu}C/cm^2-R$ of the X-ray sensitivity were showed in below $1V/{\mu}m$. In addition, the signal to noise ratio showed the values of above 5000 at operating voltage.

Comparison of the Detection Efficiency $a-Se_{1-x}As_x$ in X-ray Detection Sensor of $Gd_2O_2S(Eu^{2+})/a$-Se Structure ($Gd_2O_2S(Eu^{2+} )/a$-Se$ 구조의 X선 검출 센서에서 $a-Se_{1-x}As_x$의 검출효율 비교)

  • Kang, Sang-Sik;Park, Ji-Koon;Lee, Dong-Gil;Mun, Chi-Wung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.436-439
    • /
    • 2002
  • Recently, It has performed that the basic research of the photoconductive material and the development and application of the digital radiograph detector which is divided into the direct and indirect method. The objective of this study investigate the effect of the electric characteristic about changing the composition of Arsenic in hybrid detector system for compensating a defect of conventional. We fabricated samples using the amorphous Selenium and Arsenic alloy with various concentrations of the Arsenic{seven step 0.1%, 0.3%, 0.5%, 1%, 1.5%, 3%, 5%). And using EFIRON optical adhesives the formed multi-layer$(Gd_{2}O_{2}S(Eu^{2+}))$ composed phosphor layer. X-ray and light sensitivity was measured to study x-ray response characteritics. As results, highest value was measured as output net charge and SNR were $315.7pC/cm^2/mR$ and 99.4 at 0.3%As doping ratio.

  • PDF

Stochastic nature of magnetic processes studied by full-field soft X-ray microscopy

  • Im, Mi-Young
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1174-1181
    • /
    • 2018
  • In nanomagnetism, one of the crucial scientific questions is whether magnetic behaviors are deterministic or stochastic on a nanoscale. Apart from the exciting physical issue, this question is also of paramount highest relevance for using magnetic materials in a wealth of technological applications such as magnetic storage and sensor devices. In the past, the research on the stochasticity of a magnetic process has been mainly done by macroscopic measurements, which only offer ensemble-averaged information. To give more accurate answer for the question and to fully understand related underlying physics, the direct observation of statistical behaviors in magnetic structures and magnetic phenomena utilizing advanced characterization techniques is highly required. One of the ideal tools for such study is a full-field soft X-ray microscope since it enables imaging of magnetic structures on the large field of view within a few seconds. Here we review the stochastic behaviors of various magnetic processes including magnetization reversal process in thin films, magnetic domain wall motions in nanowires, and magnetic vortex formations in nanodisks studied by full-field soft X-ray microscopy. The origin triggering the stochastic nature witnessed in each magnetic process and the way to control the intrinsic nature are also discussed.

A CMOS Bandgap Reference Voltage Generator for a CMOS Active Pixel Sensor Imager

  • Kim, Kwang-Hyun;Cho, Gyu-Seong;Kim, Young-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • v.5 no.2
    • /
    • pp.71-75
    • /
    • 2004
  • This paper proposes a new bandgap reference (BGR) circuit which takes advantage of a cascode current mirror biasing to reduce the V$\_$ref/ variation, and sizing technique, which utilizes two related ratio numbers k and N, to reduce the PNP BJT area. The proposed BGR is designed and fabricated on a test chip with a goal to provide a reference voltage to the 10 bit A/D(4-4-4 pipeline architecture) converter of the CMOS Active Pixel Sensor (APS) imager to be used in X-ray imaging. The basic temperature variation effect on V$\_$ref/ of the BGR has a maximum delta of 6 mV over the temperature range of 25$^{\circ}C$ to 70$^{\circ}C$. To verify that the proposed BGR has radiation hardness for the X-ray imaging application, total ionization dose (TID) effect under Co-60 exposure conditions has been evaluated. The measured V$\_$ref/ variation under the radiation condition has a maximum delta of 33 mV over the range of 0 krad to 100 krad. For the given voltage, temperature, and radiation, the BGR has been satisfied well within the requirement of the target 10 bit A/D converter.

Development of Amorphous Silicon Based Digital Radiography System (비정질 실리콘 디지털 방사선 촬영기의 개발)

  • Lee, H.K.;Suh, T.S.;Choe, B.Y.;Shin, K.S.;Kim, H.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.94-95
    • /
    • 1998
  • We developed a digital x-ray medical imaging system using commercially available amorphous silicon image sensor plate. The image readout could be accomplished within 3.5 sec after radiation exposure and be displayed on a monitor through computer interface. This system needs not the conventional x-ray films and film processors, and also provides digital radiographic images. This system is the fastest digital radiography system developed so far, and expected to replace many of the conventional x-ray film systems or digital radiography systems.

  • PDF

Settling time of dental x-ray tube head after positioning (치과용 X-선 관구의 조정시간)

  • Yoon Suk-Ja;Kang Byung-Cheol;Wang Se-Myung;Koh Chang-Sung
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.159-165
    • /
    • 2002
  • Purpose: The aim of this study was to introduce a method of obtaining the oscillation graphs of the dental x-ray tube heads relative to time using an accelerometer. Materials and Methods: An Accelerometer, Piezotron type 8704B25 (Kistler Instrument Co., Amherst, NY, USA) was utilized to measure the horizontal oscillation of the x-ray tube head immediately after positioning the tube head for an intraoral radiograph. The signal from the sensor was transferred to a dynamic signal analyzer, which displayed the magnitude of the acceleration on the Y-axis and time lapse on the X -axis. The horizontal oscillation of the tube head was measured relative to time, and the settling time was also determined on the basis of the acceleration graphs for 6 wall type, 5 floor-fixed type, and 4 mobile type dental x-ray machines. Results : The oscillation graphs showed that tube head movement decreased rapidly over time. The settling time varied with x-ray machine types. Wall-type x-ray machines had a settling time of up to 6 seconds, 5 seconds for fixed floor-types, and 1 I seconds for the mobile-types. Conclusion: Using an accelerometer, we obtained the oscillation graphs of the dental x-ray tube head relative to time. The oscillation graph with time can guide the operator to decide upon the optimum exposure moment after x-ray tube head positioning for better radiographic resolution.

  • PDF

COMPARATIVE STUDY OF DIRECT DIGITAL RADIOGRAPHIC SYSTEM WITH FILM-BASED DIGITAL IMAGING SYSTEM USING EKTASPEED AND EKTASPEED PLUS FILM (직접 디지탈 방사선 촬영시스템과 Ektaspeed 및 Ektaspeed Plus 필름을 이용한 방사선 사진용 디지탈 영상시스템과의 비교 연구)

  • Do Jung-Joo;Kim Eun-Kyung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.1
    • /
    • pp.51-70
    • /
    • 1995
  • The purpose of this investigation was to compare the direct digital radiographic system with film-based digital imaging system using Ektaspeed and Ektaspeed Plus film with respect to image characteristics and detectability and evaluate the sensor noise with the use of subtraction method. Direct digital radiographic system which used was Sens-A-Ray system(Regam Medical Systems, Sundsvall, Sweden) and film-based digital imaging system was composed of Macintosh II ci computer, high resolution Sony XC-77 CCD camera and intraoral x-ray film(Kodak Ektaspeed film, Kodak Ektaspeed Plus film). Images were taken by using CCD sensor of Sens-A-Ray system, Ektaspeed film and Ektaspeed Plus film with variable exposure time(0.06s, 0.1s, 0.16s, 0.2s, 0.3s, 0.4s, 0.5s, 0.6s, O.8s, LOs), 5 times at each exposure time. And then ektaspeed films and ektaspeed plus films were digitized using CCD camera. Image groups were divided into 3 groups; Sens-A-Ray group(direct digital radiographic system), Ektaspeed group and Ektaspeed Plus group (film-based digital imaging system) They were assessed by the following three aspects; image density, image contrast and detectability and sensor noise of Sens-A-Ray system was also evaluated. The results were as follow : 1. S group showed higher density than E , EP group except at the low exposure time(p<0.01). 2. S group showed higher contrast than E,EP group except at the high exposure time(p<0.01). 3. All groups showed good detectability at the each proper exposure time. Lowest exposure time which shows maximum detectability in S,EP group(0.5s) was lower than that in E group(0.6s). 4. Sensor noise of Sens-A-Ray system generally increased according to exposure time. On the basis of the above results, it was considered that Sens-A-Ray system could show higher speed, higher contrast than Ektaspeed, Ektaspeed Plus film except at too high and low exposure time and the same detectability as the conventional intraoral film.

  • PDF

Development of portable digital radiography system with device for sensing X-ray source-detector angle and its application in chest imaging (엑스선촬영 각도를 측정할 수 있는 장치 개발과 흉부 X선 영상촬영에서의 적용)

  • Kim, Tae-Hoon;Heo, Dong-Woon;Ryu, Jong-Hyun;Jeong, Chang-Won;Jun, Hong Young;Kim, Kyu Gyeom;Hong, Jee Min;Jang, Mi Yeon;Kim, Dae Won;Yoon, Kwon-Ha
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2017.01a
    • /
    • pp.235-238
    • /
    • 2017
  • This study was to develop a portable digital radiography (PDR) system with a function measuring the X-ray source-with-detector angle (SDA) and to evaluate the imaging performance for the diagnosis of chest imaging. The SDA device consisted of an Arduino, an accelerometer and gyro sensor, and a Bluetooth module. According to different angle degrees, five anatomical landmarks on chest images were assessed using a 5-point scale. Mean signal-to-noise ratio and contrast-to-noise ratio were 182.47 and 141.43. Spatial resolution (10% MTF) and entrance surface dose were 3.17 lp/mm ($157{\mu}m$) and 0.266mGy. The angle values of SDA device were not significant difference as compared to those of the digital angle meter. In chest imaging, SNR and CNR values were not significantly different according to different angle degrees (repeated-measures ANOVA, p>0.05). The visibility scores of the border of heart, 5th rib and scapula showed significant differences according to different angles (rmANOVA, p<0.05), whereas the scores of the clavicle and 1st rib were not significant. It is noticeable that the increase in SDA degree was consistent with the increase of visibility score. Our PDR with SDA device would be useful to be applicable to clinical radiography setting according to the standard radiography guideline at various fields.

  • PDF