Change of PAE according to Detector Measurement Method (검출기 측정방법에 따른 PAE값의 변화)

  • Im, In-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.307-311
    • /
    • 2010
  • The aim of this study is to investigate PAE, as the result of the test of kVp accuracy, according to detector measurement method. Based on the indicated value of 70kVp, each distance between a focus and a kVp meter was 100cm, 80cm and 60cm and the angle of X-ray tube was set on $5^{\circ},\;10^{\circ},\;15^{\circ},\;20^{\circ},\;25^{\circ},\;30^{\circ}$. Each indicated value, 60kVp, 70kVp, 80kVp, 90kVp and 100 kVp, was used compare Small focus with Large focus. As a result, PAE on the side of cathode was higher than it on the side of anode in the case of 100cm and PAE on the side of anode was higher in the case of 80cm and 60cm. The coefficient rate was stable both the side of cathode and anode in the case of 100cm and it was fluctuated in the case of 80cm and 60cm. PAE in the case of Small focus was higher than Large focus and it was disproportionate to an indicated value. Error rate was in inverse proportion to the indicated value.

Designing boundary detector of the object on SSM (통계 지식 기반(SSM)에서 대상 물체의 경계 검출기 설계)

  • Yoo, Sang-Jin;Park, Jong-Koo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2003.11a
    • /
    • pp.511-514
    • /
    • 2003
  • 본 연구는 입력된 영상으로부터 특정한 형태를 이루고 있는 대상 물체를 추출함에 있어, 처리에 소요되는 시간 비용(Time cost)을 줄이는 것을 목적으로 하고 있다. 이를 위하여 특정 관심 지역(Region of Interest)이나 대상 물체(Tareet object)의 경계 검출(Boundary detection)을 하는 과정에 통계학적 수치자료(SSM : Statistical Shape Model)를 사용한 접근법을 이용하였다. 또한, 향후 연구 방향인 의료 영상해석(Medical image analysis)으로의 확장성을 고려, 의료 영상 해석에 많이 사용되어지는 MRI, CT, X-Ray 이미지가 Gray level 영상이라는 것을 감안하여 Gray level 영상을 연구 대상으로 삼았다.

  • PDF

Emission Properties of ZnO Grown by PLD (PLD로 증착한 ZnO 박막의 발광 특성 분석)

  • Bae, Sang-Hyuck;Lee, Sang-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.422-424
    • /
    • 2000
  • ZnO thin films for light emission device have been deposited on sapphire and silicon substrates by pulsed laser deposition technique(PLD). A Nd:YAG laser was used with the wavelength of 355 nm. In order to investigate the emission properties of ZnO thin films, PL measurements with an Ar ion laser as a light source using an excitation wavelength of 351 nm and a power of 100 mW are used. All spectra were taken at room temperature by using a grating spectrometer and a photomultiplier detector. ZnO exhibited PL bands centered around 390, 510 and 640 nm, labeled near ultra-violet (UV), green and orange bands. Structural properties of ZnO thin films are analized with X-ray diffraction (XRD).

  • PDF

Passivation effect on large volume CdZnTe crystals

  • B. Park;Y. Kim;J. Seo;J. Byun;K. Kim
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4620-4624
    • /
    • 2022
  • Several cadmium zinc telluride (CZT) crystals were fabricated into radiation detectors using methods that included slicing, dicing, lapping, polishing, and chemical etching. A wet passivation with sodium hypochlorite (NaOCl) was then carried out on the Br-etched detectors. The Te-rich layer on the CZT surface was successfully compensated to the Te oxide layer, which was analyzed with X-ray photoelectron spectroscopy data of both a Br-etched crystal and a passivated CZT crystals. We confirmed that passivation with NaOCl improved the transport property by analyzing the mobility-lifetime product and surface recombination velocity. The electrical and spectroscopic properties of large volume detectors were compared before and after passivation, and then the detectors were observed for a month. Both bar and quasi-hemispherical detectors show an enhancement in performance after passivation. Thus, we could identify the effect of NaOCl passivation on large volume CZT detectors.

Growth of HgCdTe thin film by the hot-wall epitaxy method (Hot-wall epitaxy 방법에 의한 HgCdTe 박막 성장)

  • 최규상;정태수
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.4
    • /
    • pp.406-410
    • /
    • 2000
  • Using the hot-wall epitaxy method, we grew a $Hg_{1-x}Cd_xTe$ (MCT) thin film in-situ after growing (111) CdTe of 9 $mu \textrm{m}$ as a buffer layer. The value of FWHM of double crystal x-ray diffraction rocking curve was 125 arcsec and the surface morphology was clean with a small roughness of 10 nm. From measuring the photocurrent of the grown MCT thin film, the maximum peak wavelength and the cut-off wavelength were 1.1050 $\mu\textrm{m}$ (1.1220 eV) and 1.2632 $\mu\textrm{m}$ (0.9815 eV), respectively. This peak wavelength corresponds to the peak of the band gap due to the intrinsic transition of the photoconductor. Therefore, the MCT thin film could be used as the photoconducting detector sensing a near-IR wavelength band from 1.0 to 1.6 $\mu\textrm{m}$.

  • PDF

Implementation of a Coded Aperture Imaging System for Gamma Measurement and Experimental Feasibility Tests

  • Kim, Kwangdon;Lee, Hakjae;Jang, Jinwook;Chung, Yonghyun;Lee, Donghoon;Park, Chanwoo;Joung, Jinhun;Kim, Yongkwon;Lee, Kisung
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.6 no.1
    • /
    • pp.66-70
    • /
    • 2017
  • Radioactive materials are used in medicine, non-destructive testing, and nuclear plants. Source localization is especially important during nuclear decommissioning and decontamination because the actual location of the radioactive source within nuclear waste is often unknown. The coded-aperture imaging technique started with space exploration and moved into X-ray and gamma ray imaging, which have imaging process characteristics similar to each other. In this study, we simulated $21{\times}21$ and $37{\times}37$ coded aperture collimators based on a modified uniformly redundant array (MURA) pattern to make a gamma imaging system that can localize a gamma-ray source. We designed a $21{\times}21$ coded aperture collimator that matches our gamma imaging detector and did feasibility experiments with the coded aperture imaging system. We evaluated the performance of each collimator, from 2 mm to 10 mm thicknesses (at 2 mm intervals) using root mean square error (RMSE) and sensitivity in a simulation. In experimental results, the full width half maximum (FWHM) of the point source was $5.09^{\circ}$ at the center and $4.82^{\circ}$ at the location of the source was $9^{\circ}$. We will continue to improve the decoding algorithm and optimize the collimator for high-energy gamma rays emitted from a nuclear power plant.

Acquisition of High Resolution Images and its Application using Synchrotron Radiation Imaging System (방사광 X-선을 이용한 고해상도 영상획득과 응용)

  • 홍순일;김희중;정해조;홍진오;정하규;김동욱;제정호;김보라;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2001
  • Synchrotron radiation (SR) has several advantages over convetional x-rays, including its phase, collimation, and high flux. A synchrotron radiation beamline 5C1 at Pohang Light Source (PLS) was recently built for imaging applications. We have shown that a SR imaging system is useful in imaging microscopic structures. SR with broad-band energy spectrum were adjusted to an object by Si wafers and their energy were approximately ranging from 6 keV to 30 keV. SR were passed through an object and finally transformed into visible lights by CdWO$_4$ scintillator screen. The visible lights which were reflected at an angle of 90 degrees by gold plated mirror were detected by a CCD camera and the image data were acquired using image acquisition system. A high-resolution phantom, capacitor, adult tooth, child tooth, cancerous breast tissue, and mouse lumbar vertebra were imaged with SR imaging system. The Objects were rotated within the field of view of the CCD detector, and their projection image data were obtained at 250 steps over 180 degrees rotation. Image reconstructions were carried out in a PC by using IDLTM(Research systems, Inc., US) program. The spatial resolution of the images acquired by the SR imaging system was measured with a high-resolution chart manufactured for several micrometer resolution. The specimens were also imaged with conventional x-ray radiography system to compare the image quality of radiography obtained with the SR imaging system. The results showed more structural details and high contrast images with SR imaging system than conventional x-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications, and clinical radiography.

  • PDF

Performance Characteristic of a CsI(Tl) Flat Panel Detector Radiography System (CsI(TI) Indirect Flat Panel Detector의 선질에 따른 물리적 영상 평가)

  • Jeong, Hoi-Woun;Min, Jung-Hwan;Kim, Jung-Min;Park, Min-Seok;Lee, Gaung-Young
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.109-117
    • /
    • 2012
  • The purpose of this work was to evaluate an amorphous silicon cesium iodide based indirect flat-panel detector (FPD) in terms of their modulation transfer function (MTF), Wiener spectrum (WS, or noise power spectrum, NPS), and detective quantum efficiency (DQE). Measurements were made on flat-panel detector using the International Electrotechnical Commission (IEC) defined RQA3, RQA5, RQA7, and RQA9 radiographic technique. The MTFs of the systems were measured using an edge method. The WS(NPS) of the systems were determined for a range of exposure levels by two-dimensional (2D). Fourier analysis of uniformly exposed radiographs. The DQEs were assessed from the measured MTF, WS(NPS), exposure, and estimated ideal signal-to-noise ratios. Characteristic curve in the RQA3 showed difference in the characteristic curve from RQA5, RQA7, RQA9. MTFs were not differences according to x-ray beam quality. WS(NPS) was reduced with increasing dose, and RQA 3, RQA5, RQA7, RQA9 as the order is reduced. DQE represented the best in the 1mR, RQA 3, RQA5, RQA7, RQA9 decrease in the order. The physical imaging characteristics of FPD may also differ from input beam quality. This study gives an initial motivation that the physical imaging characteristics of FPD is an important issue for the right use of digital radiography system.

Investigation of molten fuel coolant interaction phenomena using real time X-ray imaging of simulated woods metal-water system

  • Acharya, Avinash Kumar;Sharma, Anil Kumar;Avinash, Ch.S.S.S.;Das, Sanjay Kumar;Gnanadhas, Lydia;Nashine, B.K.;Selvaraj, P.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1442-1450
    • /
    • 2017
  • In liquid metal fast breeder reactors, postulated failures of the plant protection system may lead to serious unprotected accidental consequences. Unprotected transients are generically categorized as transient overpower accidents and transient under cooling accidents. In both cases, core meltdown may occur and this can lead to a molten fuel coolant interaction (MFCI). The understanding of MFCI phenomena is essential for study of debris coolability and characteristics during post-accident heat removal. Sodium is used as coolant in liquid metal fast breeder reactors. Viewing inside sodium at elevated temperature is impossible because of its opaqueness. In the present study, a methodology to depict MFCI phenomena using a flat panel detector based imaging system (i.e., real time radiography) is brought out using a woods metal-water experimental facility which simulates the $UO_2-Na$ interaction. The developed imaging system can capture attributes of the MFCI process like jet breakup length, jet front velocity, fragmented particle size, and a profile of the debris bed using digital image processing methods like image filtering, segmentation, and edge detection. This paper describes the MFCI process and developed imaging methodology to capture MFCI attributes which are directly related to the safe aspects of a sodium fast reactor.

Hybrid Filter Based on Neural Networks for Removing Quantum Noise in Low-Dose Medical X-ray CT Images

  • Park, Keunho;Lee, Hee-Shin;Lee, Joonwhoan
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.15 no.2
    • /
    • pp.102-110
    • /
    • 2015
  • The main source of noise in computed tomography (CT) images is a quantum noise, which results from statistical fluctuations of X-ray quanta reaching the detector. This paper proposes a neural network (NN) based hybrid filter for removing quantum noise. The proposed filter consists of bilateral filters (BFs), a single or multiple neural edge enhancer(s) (NEE), and a neural filter (NF) to combine them. The BFs take into account the difference in value from the neighbors, to preserve edges while smoothing. The NEE is used to clearly enhance the desired edges from noisy images. The NF acts like a fusion operator, and attempts to construct an enhanced output image. Several measurements are used to evaluate the image quality, like the root mean square error (RMSE), the improvement in signal to noise ratio (ISNR), the standard deviation ratio (MSR), and the contrast to noise ratio (CNR). Also, the modulation transfer function (MTF) is used as a means of determining how well the edge structure is preserved. In terms of all those measurements and means, the proposed filter shows better performance than the guided filter, and the nonlocal means (NLM) filter. In addition, there is no severe restriction to select the number of inputs for the fusion operator differently from the neuro-fuzzy system. Therefore, without concerning too much about the filter selection for fusion, one could apply the proposed hybrid filter to various images with different modalities, once the corresponding noise characteristics are explored.