실리콘 핀 포토다이오드를 이용한 능동형 방사선 피폭 전자선량계의 구현 (Implementation of Electronic Personal Dosimeter Using Silicon PIN Photodiode)

  • 이운근;백광렬;권석근
    • 제어로봇시스템학회논문지
    • /
    • 제9권4호
    • /
    • pp.296-303
    • /
    • 2003
  • A personal portable type electronic dosimeter using silicon PIN photodiode and small GM tube is recently attracting much attention due to its advantages such as an immediate indication function of dose and dose rate, alerting function, and efficient management of radiation exposure history and dose data. We designed and manufactured a semiconductor radiation detector aimed to directly measure X-ray and v-ray irradiated in silicon PIN photodiode, without using high-priced scintillation materials. Using this semiconductor radiation detector, we developed an active electronic dosimeter, which measures the exposure dose using pulse counting method. In this case, it has a shortcoming of over-evaluating the dose that shows the difference between the dose measured with electronic dosimeter and the dose exposed to the human body in a low energy area. We proposed an energy compensation filter and developed a dose conversion algorithm to make both doses indicated on the detector and exposed to the human body proportional to each other, thus enabling a high-precision dose measurement. In order to prove its reliability in conducting personal dose measurement, crucial for protecting against radiation, the implemented electronic dosimeter was evaluated to successfully meet the IEC's criteria, as the KAERI (Korea Atomic Energy Research Institute) conducted test on dose indication accuracy, and linearity, energy and angular dependences.

원추형 빔 마이크로 단층촬영기술 및 그 응용 (Cone-Beam Microtomography and Its Application)

  • 김호경
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.7-14
    • /
    • 2005
  • 본 논고에서는 microfocus X 선 발생장치와 평판형 영상센서를 이용한 micro-CT 시스템의 개발과 그 응용에 대해 소개하였다. 개발과 관련하여서는 영상센서 및 시스템의 동작원리뿐만 아니라 성능평가 결과에 대해서도 간단히 언급하였는데, 이와 같은 성능평가는 추후 개선된 혹은 새로운 설계 및 제작을 위해서는 필수적으로 수반되어야 할 부분이다. 개발된 micro-CT 시스템의 응용분야 소개와 관련하여서는 몇 가지 획득 영상을 토대로 바이오 영상과 산업용 영상에 관하여 언급하였다. 바이오 영상분야에서는 현재 세계적으로 유수 의료기기업체에서 이미 제작하여 판매하고 있으며, 대부분 X선 영상증배관 혹은 CCD(charge-coupled device)를 X 선 영상획득 센서로 사용한 반면, 본 논고에서 소개한 시스템은 평판형 영상센서를 사용했다는 점에서 차별성이 있다. Micro-CT 시스템의 산업용 영상분야로의 적용은 이제 시작 단계이며, 기존 라미노그라피 시스템을 대체하거나 혹은 새로운 응용으로 자리매김할 것으로 기대된다.

현장 진단 서비스 시장 공략을 위한 '무선 X-ray 디텍터' 디자인개발에 관한 연구 (A research on remote X-ray detector design development for marketing in field diagnosis service)

  • 송성일
    • 한국결정성장학회지
    • /
    • 제27권4호
    • /
    • pp.196-205
    • /
    • 2017
  • 오늘날 의료분야의 서비스 디자인은 유 무형의 서비스 요소를 통합적으로 가시화하고 혁신적 해결책을 도출, 고객이 해당 서비스를 더 중요한 가치로 느낄 수 있도록 지원하는 실용적 서비스 연구개발로 발전하고 있는 상황이다. 개인의 소득수준이 향상되면서 의료복지와 웰빙에 대한 관심이 날로 높아지고 있어, 의료분야의 초점도 과거의 질병 질환에 대한 치료의 개념에서 예방 의료로 구심점이 이동하고 있다. 이런 추세에 맞추어 최근 의료복지에 유비쿼터스 개념을 접목하여 건강진단 및 건강관리의 시간과 공간 제약을 대폭 줄인 홈헬스케어 시스템의 연구개발이 활발히 진행되고 있고 헬스케어3.0 시대에 따른 사용자 중심의 의료 서비스와 사용자 니즈를 기반으로 한 제품 및 의료 환경 개선 요구가 증대하고 있어 그에 따라 사용자 중심 니즈와 요구가 반영된 현장 의료진단 제품 개발이 필요하다. 본 연구는 현장 의료진단 제품 중 하나인 '무선 X-ray 디텍터'를 연구 개발함에 있어 현장진단 제품에 적합한 소재와 외형을 적용하여 사용자의 요구가 충분히 반영된 제품을 개발 연구하는 것을 목표로 두고 있다.

검출기 필터를 이용한 화질의 향상 (Enhancement of Image Quality Using Detector Filter)

  • 임종남;김형태;김민혜;천권수
    • 한국방사선학회논문지
    • /
    • 제10권6호
    • /
    • pp.451-456
    • /
    • 2016
  • 방사선 검사로 환자의 병을 진단하기 위해서는 방사선 피폭이 따르게 된다. 최소한의 피폭으로 병변을 진단하는 일반촬영에 이중 엑스선 에너지 기법의 임상적용 가능성을 SNR 및 화질 점수화의 지표로 조사하였다. 이중 엑스선 에너지 기법은 검출기로 사용되는 두 개의 Image Plate 사이에 0.5 mm 두께의 Cu와 Al 필터를 추가함으로써 구현하였다. 한 번의 엑스선 조사로 획득된 두 IP 영상을 Subtraction 및 Enhance Contrast 기법을 적용하여 획득하였다. Enhance 영상은 첫 번째 IP에서 획득한 First 영상보다 SNR이 우수한 것으로 측정되었다. 이 일반촬영의 이중 엑스선 에너지 기법은 피폭선량을 줄이면서 영상의 품질을 높일 수 있는 방법으로 임상에서 매우 유용하게 적용될 수 있을 것이다.

THE EFFECT OF SURFACE ROUGHNESS OF CSI(TL) MICRO-COLUMNS ON THE RESOLUTION OF THE X-RAY IMAGE; OPTICAL SIMULATION STUDY

  • Kim, Hyun-Ki;Bae, Jun-Hyung;Cha, Bo-Kyung;Jeon, Ho-Sang;Kim, Jong-Yul;Kim, Chan-Kyu;Cho, Gyu-Seong
    • Journal of Radiation Protection and Research
    • /
    • 제34권1호
    • /
    • pp.25-30
    • /
    • 2009
  • Micro-columnar CsI(Tl) is the most popular scintillator material which is used for many indirect digital X-ray imaging detectors. The light scattering at the surface of micro-columnar CsI(Tl) scintillator was studied to find the correlation between the surface roughness and the resultant image resolution of indirect X-ray imaging detectors. Using a commercially available optical simulation program, Light Tools, MTF (Modulation Transfer Function) curves of the CsI(Tl) film thermally evaporated on glass substrate with different thickness were calculated and compared with the experimental estimation of MTF values by the edge X-ray image method and CCD camera. It was found that the standard deviation value of Gaussian scattering model which is determined by the surface roughness of micro-columns could certainly change the MTF value of image sensors. This model and calculation methodology will be beneficial to estimate the overall performance of indirect X-ray imaging system with CsI(Tl) scintillator film for optimum design depending on its application.

2400 grooves/mm 비등간격 오목에돌이발을 이용하는 평면결상형 연엑스선 분광기의 특성 해석 (Analysis of a flat-field soft x-ray spectrometer using a 2400-grooves/mm varied line-spacing concave grating)

  • 최일우;남창희
    • 한국광학회지
    • /
    • 제13권3호
    • /
    • pp.189-196
    • /
    • 2002
  • 파장 50 $\AA$ 이하의 연엑스선 영역에서 사용될 평면결상형 연엑스선 분광기의 구성요소와 정렬조건을 결정하고 분광기의 분광학적 특성을 해석하였다. 평면결상형 연엑스선 분광기는 토로이드거울, 실틈, 비등간격 오목에돌이발, 연엑스선 검출기로 구성되어 있다. 토로이드거울과 홈간격이 2400 grooves/mm인 비등간격 오목에돌이발을 사용하여 공간분해된 빛띠가 단일 평면 위에 결상되도록 분광기를 구성하였다. 토로이드거울은 연엑스선 광선이 에돌이발에 비스듬하게 입사할 때 발생되는 비점 수차를 보상하기 위해 사용되었다. 파면수차 이론을 적용하여 분광기가 가지는 파장분해와 공간분해를 계산하고, 에돌이 현상에 대한 스칼라 이론을 적용하여 에돌이발의 에돌이효율을 계산하였다.

방사선 노출에 따른 3T APS 성능 감소와 몬테카를로 시뮬레이션을 통한 픽셀 내부 결함의 비교분석 (A Comparison between the Performance Degradation of 3T APS due to Radiation Exposure and the Expected Internal Damage via Monte-Carlo Simulation)

  • 김기윤;김명수;임경택;이은중;김찬규;박종환;조규성
    • 방사선산업학회지
    • /
    • 제9권1호
    • /
    • pp.1-7
    • /
    • 2015
  • The trend of x-ray image sensor has been evolved from an amorphous silicon sensor to a crystal silicon sensor. A crystal silicon X-ray sensor, meaning a X-ray CIS (CMOS image sensor), is consisted of three transistors (Trs), i.e., a Reset Transistor, a Source Follower and a Select Transistor, and a photodiode. They are highly sensitive to radiation exposure. As the frequency of exposure to radiation increases, the quality of the imaging device dramatically decreases. The most well known effects of a X-ray CIS due to the radiation damage are increments in the reset voltage and dark currents. In this study, a pixel array of a X-ray CIS was made of $20{\times}20pixels$ and this pixel array was exposed to a high radiation dose. The radiation source was Co-60 and the total radiation dose was increased from 1 to 9 kGy with a step of 1 kGy. We irradiated the small pixel array to get the increments data of the reset voltage and the dark currents. Also, we simulated the radiation effects of the pixel by MCNP (Monte Carlo N-Particle) simulation. From the comparison of actual data and simulation data, the most affected location could be determined and the cause of the increments of the reset voltage and dark current could be found.

영상유도 양성자치료를 위한 콘빔 CT 재구성 알고리즘: 기하학적 보정방법에 관한 연구 (Geometric Calibration of Cone-beam CT System for Image Guided Proton Therapy)

  • 김진성;조민국;조영빈;윤한빈;김호경;윤명근;신동호;이세병;이레나;박성용;조관호
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.209-218
    • /
    • 2008
  • IMRT, 양성자 치료와 같이 방사선 치료 기술이 발전할수록 치료 시 환자의 위치를 확인하고 그 정확성을 평가하는 기술의 중요성이 강조되고 있다. 현재 국립암센터 양성자치료센터에 설치되어 있는 양성자 치료기의 단순 X-선 영상시스템을 이용하여 콘빔 CT (cone-beam CT) 3차원 영상을 획득, 영상유도 방사선 치료의 가능성을 확인하고자 하였다. 양성자 치료기에 설치되어있는 X-선 영상시스템(SDD: 2,108 mm, SOD: 1,511 mm, Varian a277 x-ray tube & Varian Paxscan 4030: a-Si+DRZ screen)을 이용하여 양성자 갠트리를 $2^{\circ}$씩 회전시켜가면서 기하학적인 오차 측정을 위한 팬톰과 인체 팬톰 (Humanoid phantom, Rando, CA, USA)의 투사영상을 획득하였다. 현재 시스템적으로 연속적인 회전과 영상획득이 지원되지 않아서 영상획득 후 갠트리를 회전하는 방법으로 투사영상을 획득하였다. 기하학적 오차측정을 위한 팬텀과 두경부 팬텀에 대해서 $360^{\circ}$를 회전하며 180장의 투사영상($2,304{\times}3,200$, 14 bit with 127${\mu}m$ pixel pitch)을 관전압 85 kVp, 관전류 80 mA, 조사시간 0.5 s의 조건으로 촬영하였다. 콘빔 CT 영상재구성을 위해 Ram-Lak filter를 적용한 Feldkamp cone-beam 알고리즘을 사용하였으며, 획득한 180장의 투사영상을 사용하여 $0.4{\times}0.4{\times}0.4mm^3$의 voxel size를 가진 $512{\times}512{\times}512$ CT영상을 재구성하였다. 기하학적인 오차 측정방법을 통해 X-선 선원, 검출기와 갠트리의 기하학적 정보를 측정하였다. 측정된 결과에 의하면 검출기가 $0.25^{\circ}$ 회전된 오차를 보이는 것을 발견하였다. 기하학적 교정으로 재구성된 콘빔 CT 영상을 multi-planar view (axial, sagittal and coronal view) 및 3차원 영상으로 재구성하여 비교 평가 하였다. 현재 양성자치료기에 설치되어있는 단순 X-선 영상 시스템에서 기하학적 오차 측정을 위한 볼 팬텀을 이용하여 시스템의 오차를 측정하였다. 측정한 오차를 바탕으로 기하학적 교정을 통해서 두경부 및 복부 팬텀에 대한 3차원 영상인 콘빔 CT 영상들을 재구성하였다. 추후 연속적인 회전을 통한 영상획득이 가능하게 된다면, 보다 정확하고 신속한 영상재구성이 가능 하며 콘빔 CT가 영상유도 양성자 치료에 매우 유용할 것으로 사려된다.