• Title/Summary/Keyword: X-ray Detector

Search Result 456, Processing Time 0.03 seconds

Fabrication and Characterization of Polycrystalline Mereuric Iodide Films using Particle-in-Binder Methods (Particle-in-Binder(PIB) 법을 이용한 다결정 $HgI_2$ 필름 제작 및 특성 연구)

  • Cha, Byung-Youl;Cho, Sung-Ho;Kim, So-Yeong;Woon, Min-Seuk;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.330-330
    • /
    • 2007
  • Polycrystalline mercuric iodide $HgI_2$) films are being developed as a new detector technology for digital x-ray imaging. The $HgI_2$ is generally vacuum deposited by physical vapor deposition (PVD) process. But the PVD thick deposition has been caused any instability in the biasing due to any defects or cracks. In this work we present a new particle-in-binder (PIB) methodologies used for the $HgI_2$ thick films. These growth techniques can be easily extended to produce much larger film areas. This paper, for the first time, presents results and comparison of polycrystalline $HgI_2$ films derived by various PIB methods. We investigated the structural and morphological properties of the films using X-ray diffraction (XRD) and scanning electron microscopy (SEM) analysis. The films were characterized with respect to their electrical properties and in response to x-ray photons. Physical and electrical results were also compared between conventional polycrystalline PVD and our detectors. Leakage current as low as $350\;pA/cm^2$ at the bias voltage of ~ 200 V has been observed. And high sensitivity and good linearity in the response to x-rays was obtained in the film derived by PIB sedimentation method. Our future efforts will concentrate on optimization of film growth techniques for uniform large area deposition on image readout arrays.

  • PDF

The fabrication and evaluation of CdS sensor for diagnostic x-ray detector application (진단 X선 검출기 적용을 위한 CdS 센서 제작 및 성능 평가)

  • Park, Ji-Koon;Lee, Mi-Hyun;Choi, Young-Zoon;Jung, Bong-Zae;Choi, Il-Hong;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.2
    • /
    • pp.21-25
    • /
    • 2010
  • Recently, various semiconductor compounds as radiation detection material have been researched for a diagnostic x-ray detector application. In this paper, we have fabricated the CdS detecton sensor that has good photosensitivity and high x-ray absorption efficiency among other semiconductor compounds, and evaluated the application feasibility by investigating the detection properties about energy range of diagnostic x-ray generator. We have fabricated the line voltage selector(LCV) for a signal acquisition and quantities of CdS sensor, and designed the voltage detection circuit and rectifying circuit. Also, we have used a relative relation algorithm according to x-ray exposure condition, and fabricated the interface board with DAC controller. Performance evaluation was investigated by data processing using ANOVA program from voltage profile characteristics according to resistive change obtained by a tube voltage, tube current, and exposure time that is a exposure condition of x-ray generator. From experimental results, an error rates were reduced according to increasing of a tube voltage and tube current, and a good properties of 6%(at 90 kVp) and 0.4%(at 320 mA) ere showed. and coefficient of determination was 0.98 with relative relation of 1:1. The error rate according to x-ray exposure time showed exponential reduction because of delayed response velocity of CdS material, and the error rate has 2.3% at 320 msec. Finally, the error rate according to x-ray dose is below 10%, and a high relative relation was showed with coefficient of determination of 0.9898.

Calculation of Gamma-ray Energy Spectrum for Spherical BGO Scintillation Detector (구형 BGO 섬광 검출기에 대한 감마선 에너지 스펙트럼 계산)

  • Doh, Sih-Hong;Kim, Jong-Il;Park, Hung-Ki;Chu, Min-Cheal;Jeong, Jung-Hyun;Kim, Gi-Dong;Lee, Dae-Won
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.4
    • /
    • pp.1-9
    • /
    • 1995
  • The ${\gamma}$-ray deposition spectra were calculated by Monte Calro method to obtain the scintillation characteristics of the ${\gamma}$-ray for BGO scintillation detector with the spherical shape of 1.25 cm radius. The code used in calculating the ${\gamma}$-ray deposition spectra was made for personal computer with qbasic language. Also the ${\gamma}$-ray energy spectra of $^{22}Na$, $^{137}Cs$ and $^{207}Bi$ were measured with the detector. The energy dependent resolution below 2000 keV for the detector was determined by estimating the standard deviation of the photopeak fitted with gaussian function, and $X^{2}$ fitting using Nardi's empirical formula. The measured spectra of $^{22}Na$ and $^{137}Cs$ were compared with the broadened spectra which were obtained by broadening the calculated ${\gamma}$-ray deposition spectra with the energy dependent resolution. The absolute efficiency and the intrinsic peak efficiency of the detector were obtained by calculating the ${\gamma}$-ray deposition spectrum with the code.

  • PDF

The X-ray Detection Characteristic of vacuum evaporated CsI for Digital X-ray Image Sensor (디지털 X선 영상센서 적용을 위한 진공증착 CsI 특성평가)

  • Shin, Jung-Wook;Park, Ji-Koon;Choi, Jang-Yong;Seok, Dea-Woo;Kim, Jea-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.15-18
    • /
    • 2003
  • In recent years, there has been keen interest in phosphor materials responding X-ray. Cesium iodide of the materials is a material with a high $\gamma$-ray stopping power due to its relative high density and atomic number. CsI is noted for its high resistance to thermal and mechanical shock due to the absence of a cleavage plane. To design the structure of CsI detector, we analysed the structure with SEM and XRD and measured UV meter.

  • PDF

A K-Ray Image Reconstruction by the Direct Detection Method (직접검출방식(直接檢出方式)에 의한 X선영상(X線影像)의 재구성(再構成)에 관(關)한 연구(硏究))

  • Kang, Hee-Doo
    • Journal of radiological science and technology
    • /
    • v.14 no.1
    • /
    • pp.61-72
    • /
    • 1991
  • In this paper, the rotating plate method extracting signal and reconstructing original image was proposed. The rotating methode has cell detector array each of which has used in the medical diagnosis X-ray photography. The major problem using the simple horizontal moving or non-moving methode is the size and number of detector cells which have the considerable affection on the sharpness and resolution of the reconstructed image. Secondary, the estimated pixel values of non-detected real points which are placed between detector cells will be the distorted pixels in the reconstructed image. Therefore, the proposed rotating plate method has the exact distribution on the uncertain pixels which were reconstructed by conventional methods to solve there problems. And then, the image using the rotated plate's cell out put signal was reconstructed on the computer simulation. The method will rotated the detector array plate to solve the reconstruction from the detector size and number of conventional methods. The result of simulation has estimated the original pixel position and 81 pixel/mm resolution which the reconsiderlation of the detector's moving orientation, the proposed method has 25 pixel/mm resolution. These results have been represented by 3-D computer graphics.

  • PDF

Study of Noise Reducion in X-ray image (X-선 영상에서의 노이즈 제거에 대한 연구)

  • Park, Jong-Duk;Jeon, Sung-Chae;Huh, Young;Jin, Seong-Oh
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.391-392
    • /
    • 2006
  • In x-ray imaging system, twokinds of noises are involved. First, the charge generated from the radiation interaction with the detector during exposure is modeled by Poisson process. Second, the signal is then added by readout electronics noise, which is modeled by Gaussian distribution. In this paper, we applied Wiener filter and Wavelet to remove noise from medical X-ray image, the result shows that wavelet yield better segmentation results than the wiener filter.

  • PDF

Stability of a QD-blended Organic Photodiode for X-ray Imaging (X-선 영상 취득을 위한 양자점 혼합 유기재료 광다이오드의 안정성에 관한 연구)

  • Lee, Jehoon;Kang, Jungwon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.2
    • /
    • pp.15-18
    • /
    • 2017
  • In this study, we have studied the characteristics of the organic photodiode varying due to the blending conditions of the quantum dots (QDs). The active layer of the photodiode was formed with poly (3-hexylthiophene) and phenyl-C61-butyric acid methyl ester, and CdSe QDs with and without ZnS shell were blended in the active layer. The photodiode with CdSe/ZnS QDs showed the highest power conversion efficiency (PCE) and short-circuit current (Jsc). The performance change of the organic photodiode by X-ray irradiation was also measured. Regardless of X-ray irradiation conditions, the photodiode with CdSe/ZnS QDs showed better stability than other cases.

  • PDF