• Title/Summary/Keyword: X-ray 구조

Search Result 2,288, Processing Time 0.027 seconds

The Study of the Geometric Structure Optimization for the Stereo X-ray Inspection System Using the Calibration (Calibration을 통한 스테레오 X-ray 검색장치의 기하구조 최적화 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho;Lee, Seung-Min;Park, Jong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3422-3427
    • /
    • 2010
  • In this paper, we presents a sensor calibration technique using stereo X-ray images to provide efficient inspection of fast moving cargo objects. Stereo X-ray scanned images are acquired from a specially designed equipment which consists of a X-ray source, dual-linear array detector, and a conveyor system. Dual detector is installed so that rectified stereo X-ray images of objects are acquired. Using the stereo X-ray images, we carry out a sensor calibration to find the correspondences between the images and reconstruct 3-D shapes of real objects. Using the Image acquired from the stereo detectors with varying distances, we calculated the GCP(ground control point)of the image. And we figure out the error by comparing calculated GCP and GCP of the real object. The experimental results show the proposed technique can enhance the accuracy of stereo matching and give more efficient visualization for cargo inspection image.

X-Ray Resonant Magnetic Scattering Study of Magnetic Structures and Magnetic Switching Mechanism in Magnetic Multilayers and Nanostructures (엑스선 공명 자기 산란을 이용한 자성 다층박막 및 나노 구조체의 자기 구조와 자기 스위칭 메커니즘의 연구)

  • Lee, Dong-Ryeol
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.4
    • /
    • pp.160-166
    • /
    • 2010
  • X-ray resonant magnetic scattering (XRMS) allows us to extract magnetic depth profiles in magnetic multilayers and magnetization distribution in magnetic nanostructures in element-specific manner using x-ray reflectivity and diffraction. XRMS is explained with a brief introduction and examples of magnetic structures and magnetic switching mechanism in magnetic multilayers and nanostructures.

Microscopic analysis of gas hydrates using X-ray diffraction method (X-ray diffraction을 이용한 가스 하이드레이트 미세구조 분석)

  • Lee, Jong-Won;Seol, Ji-Woong;Koh, Dong-Yeun;Lee, Huen
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.178-181
    • /
    • 2008
  • 다양한 조성을 갖는 $CH_4+CO_2$ 혼합 기체 하이드레이트 샘플의 미세 구조 분석을 위하여 X-ray 회절 방법을 이용하였다. X-ray 회절 분석을 이용할 경우, 하이드레이트로의 전환율과 같은 정성적인 분석뿐 아니라 각 객체별 cage occupancy와 같은 정량적인 분석까지도 가능한 것으로 나타났다. 또한 이렇게 얻어진 X-ray 회절 분석 결과 및 refinement 결과를 $^{13}C$ 고체 NMR 방법과 교차 비교함으로써 측정 결과의 신뢰도를 높이려 하였다. 얻어진 분석 결과는 이후 가스 하이드레이트를 이용한 다양한 연구 분야에서 저장용량 평가 및 객체 점유율과 같은 미세 구조 정보를 얻는 데에 유용하게 사용될 것으로 전망된다.

  • PDF

X-ray Reflection Mirror of the Periodic Multilayer Structure (주기적인 구조를 갖는 X-선 반사경 설계)

  • Gwon, Taek-Yong;Jeong, Jin-U;Sin, Jin-Uk;Choe, Jae-Ho
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2007.07a
    • /
    • pp.21-22
    • /
    • 2007
  • The periodic multilayer is considered as the X-ray reflection mirror. High X-ray reflectivity from the incident angle greater than the grazing critical angle can be obtained by the periodic multilayer structure. The Optical constants are investigated in order to determine the material for X-ray reflection mirror. The X-ray reflection mirror is designed for W, Si using computer simulation. The reflectivity is calculated for various incident angles and ratio of thickness.

  • PDF

Image Calibration Techniques for Removing Cupping and Ring Artifacts in X-ray Micro-CT Images (X-ray micro-CT 이미지 내 패임 및 동심원상 화상결함 제거를 위한 이미지 보정 기법)

  • Jung, Yeon-Jong;Yun, Tae-Sup;Kim, Kwang-Yeom;Choo, Jin-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.11
    • /
    • pp.93-101
    • /
    • 2011
  • High quality X-ray computed microtomography (micro-CT) imaging of internal microstructures and pore space in geomaterials is often hampered by some inherent noises embedded in the images. In this paper, we introduce image calibration techniques for removing the most common noises in X-ray micro-CT, cupping (brightness difference between the periphery and central regions) and ring artifacts (consecutive concentric circles emanating from the origin). The artifacts removal sequentially applies coordinate transformation, normalization, and low-pass filtering in 2D Fourier spectrum to raw CT-images. The applicability and performance of the techniques are showcased by describing extraction of 3D pore structures from micro-CT images of porous basalt using artifacts reductions, binarization, and volume stacking. Comparisions between calibrated and raw images indicate that the artifacts removal allows us to avoid the overestimation of porosity of imaged materials, and proper calibration of the artifacts plays a crucial role in using X-ray CT for geomaterials.

The Compensation of Image Distortion on the X - Ray Image Intensifier (X - Ray 검사 시스템에서 Image Intensifier의 왜곡 보정)

  • Shin, Dong-Chul;Oh, Choon-Suk
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.4
    • /
    • pp.1044-1047
    • /
    • 1998
  • Non-destructive x-ray inspection system needs image intensifier to obtain the x-ray image. Captured image from image intensifier is distorted because the input plate of image intensifier has a spherical surface. In the research, in order to compensate this image distortion, we created the model of image intensifier and show mathematically that the image distortion was compensated. To show the performance of the proposed method, experiment was performed in real x-ray inspection system.

  • PDF

Fabrication of a Micro-Structure by Modified DXRL Process (수정된 DXRL 공정에 의한 미세구조 제작)

  • Han, Sang-Pil;Jeong, Myung-Yung;Jung, Suk-Won;Kim, Jin-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.9
    • /
    • pp.1517-1523
    • /
    • 2003
  • Deep X-ray lithography (DXRL), a fabrication method for the production of microstructures with a high aspect ratio, plays an important role in the subsequent electroplanting process. However, secondary radiation is generated during X-ray exposure and damages the resist adhesion to the metal layer. To solve adhesion problems, we modified the conventional DXRL process, changing the sequence of polymer adhesion in DXRL process. With optimized X-ray exposure and development conditions based on a calculated and modified X-ray power spectrum, we fabricated various polymer microstructures and achieved a maximum aspect ratio of 40.

Fabrication of X-ray Mask Using Graphite Sheet (Graphite Sheet를 이용한 X-ray Mask 제작)

  • Cho, Jin-Woo;Hong, Sung-Jei;Park, Soon-Sup;Shin, Sang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3276-3278
    • /
    • 1999
  • LIGA 기술을 제품의 대량생산에 적용하기 위해서는 한번에 넓은 면적을 노광할 수 있는 X-ray 마스크가 요구된다. 기존에 널리 사용되고 있는 SiN 멤브레인 마스크는 내구성이 좋지 않고 면적을 크게하기 어렵다. 따라서 본 연구에서는 이러한 단점을 보완하기 위해 상용 graphite sheet를 이용하여 X-ray 마스크를 제작하였다. 제작된 graphite 마스크와 SiN 마스크를 이용하여 동일한 조건에서 X-ray 노광 실험을 하였고 마스크의 외형변화를 관찰하였다. 그 결과 SiN 마스크는 에너지 2.3GeV, 평균 전류 110mA에서 약 18시간 만에 파괴되었으나 graphite mask는 60시간 경과 후에도 육안상의 변화는 관찰되지 않았다. 또한 graphite 마스크를 이용하여 제작된 미세구조물의 치수측정결과 오차가 $1{\mu}m$ 미만인 정밀한 구조물 제작이 가능함을 확인하였다.

  • PDF

Synchrotron Radiation Imaging of Breast Tissue Using a Phase-contrast Hard X-ray Microscope (경 엑스선 위상차 현미경을 이용한 유방 조직의 방사광 영상)

  • Jeong, Young-Ju;Bong, Jin-Gu;Park, Sung-Hwan
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.117-123
    • /
    • 2011
  • Synchrotron radiation (SR) imaging enables us to observe internal structures of biologic samples without staining. In this study, we obtained X-ray microscopic images of human breast tissues with 11.1 KeV hard X-ray microscope of the Pohang light source and used zone plates and phase-contrast technique to get high resolution X-ray images. Hard X-ray microscopic images of fibrocystic change and breast cancer tissues with a spatial resolution of 60 nm were obtained and from these images, we could observe the micro-structures of human breast tissue. Also we analyzed and compared these images, which revealed distinct features of each condition. In conclusion, SR imaging with phase-contrast hard X-ray microscope for medical application, especially in breast disease can give some useful information for clinical research.

Crystal structure analysis of orthohombic $Sr_{0.6}Ca_{0.4}CuO_2$ compound (사방정계 $Sr_{0.6}Ca_{0.4}CuO_2$ 화합물의 결정구조해석)

  • Park, H.M.;Goetz, D.;Hahn, Th.
    • Korean Journal of Crystallography
    • /
    • v.7 no.1
    • /
    • pp.20-29
    • /
    • 1996
  • Sr0.6Ca0.4CuO2 single crystal has been synthesized by flux method and characterized by the single crystal X-ray diffraction. The compound has the orthorhombic system and the space group is Cmcm(63), lattice parameters are a=3.4645Å, b=16.1417Å, c=3.8727Å. In the (Sr1-xCax)CuO2 compound the limit of Ca from substitution for Sr was determined by the change of bond length. For this, X-ray diffraction, scanning electron microscopy (SEM), energy dispersive X-ray fluorescence (EDAX) and electron probe micro-analysis (EPMA) were used. From the change of Cu-O bond length as the Ca substitution, we concluded the limit of Ca incorporation Xca≒0.73.

  • PDF