• Title/Summary/Keyword: X-joint

Search Result 589, Processing Time 0.033 seconds

The Analysis of BMD in Forearm and Hip Joint with DEXA (DEXA에 의한 아래팔과 엉덩관절의 골밀도 분석)

  • Lee, Kwang-Sung;Park, Ui-Su;Jeon, Min-Cheol
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.3
    • /
    • pp.168-173
    • /
    • 2015
  • Use of forearm and hip joint bone density scan and find the clinical usefulness of the results that can be inferred as a result of any other region sites injured by a correction factor which if One part up. Groups of 60 patients, 10 patients by age 20-70 were composed of patients measured with the forearm and lumbar spine bone mineral density T-score and Z-score of the survey for each of the three factors that it was Find the correction factor to obtain the relationship. Bone mineral density of the correlation coefficient R = 0.8 correction factor is Y = 1.341X + 0.146. T-score of correlation coefficient R = 0.804 and the correction factor Y = 0.565X - 0.327 is Z-score of the correlation coefficient R = 0.637 correction factor Y = 0.539X - 0.225. It is regarded that there will be a clinical availability which can analogize the result of a part by using the result of the other part. It will be able to determine an auxiliary role in the clinical diagnosis. Correction factor to the equation Y = 1.341X + 0.146 is recommended.

The Implications of X-ray Use in Chuna Manual Therapy from the Viewpoint of Korean Medicine Doctors

  • Kim, Tae Gyu;Gi, Yumi;Yang, Kyu Jin;Lee, Ki-Beom;Jo, Hooin;Choi, Jongho;Lee, Yoon Jae;Lee, Sanghun;Ha, In-Hyuk
    • Journal of Acupuncture Research
    • /
    • v.35 no.3
    • /
    • pp.108-114
    • /
    • 2018
  • Background: The purpose of this survey study was to understand how utilization of X-rays as an adjunct to Chuna manual therapy (CT) supports treatment, as assessed by Korean medicine doctors (KMDs). Methods: A survey was emailed to all 18,289 members of the Association of Korean Oriental Medicine (AKOM)to determine the implications of X-ray use in CT. Surveys were collected from September 22, 2017 to October 15, 2017. Results: Of the 18,289 KMDs 562 completed the survey. The implications of a radiological diagnosis (X-ray) with CT was assessed using 5 items in a questionnaire: time to diagnosis, accuracy of treatment, patient comprehension and satisfaction, CT effect, and safety of CT. Survey participants identified improvement in patient comprehension and satisfaction as the most important factor for X-ray use with CT, followed by increased safety of CT. From the determinant factors for selection of CT intensity and specific techniques, severity of clinical symptoms was shown to be the most influential factor. Degenerative changes of the spine and degree of spinal malposition were also reported to be highly influential. Conclusion: The KMDs' that participated in this study indicated that utilization of X-rays in conjunction with CT administration improved patient comprehension and satisfaction, and CT safety. Installation of radiological equipment in Korean medicine clinics where CT is provided may increase safety and patients' satisfaction.

Survey on Online Continuing Education Requirements according to Practical Experience of Nurses at Small and Medium Sized Hospitals (중소병원 간호사의 실무 경험에 따른 온라인 보수교육 요구도 조사)

  • Eun, Young;Kang, Han Sol;Jeon, Mi Yang
    • Journal of muscle and joint health
    • /
    • v.23 no.3
    • /
    • pp.197-205
    • /
    • 2016
  • Purpose: The purpose of this study was to conduct a comparison analysis on requirements of online continuing education requirements according to practical experience of nurses at small and medium-sized hospitals. Methods: Data had been collected with 236 nurses from May to June, 2015. The data were analyzed with the use of SPSS. Results: Among them, 45.8% participated in online continuing education. Nurses in beginning level required musculoskeletal diseases (20.9%), care for injuries and stomas (5.8%), and surgical disease and operation care (4.7%). Competent nurses required musculoskeletal diseases (19.7%), cerebrovascular diseases (9.9%), emergency care and CPR (8.5%), and medical nursing (8.5%). Skillful nurses required cerebrovascular diseases (13.9%), care for internal diseases (8.9%), and rehabilitation care (8.9%). Among the educational contents of diseases, the items that were significantly different according to practical experience were operation management ($x^2$=23.92, p<.001) and drug care ($x^2$=7.85, p=.020). Among continuing education methods, the items that were significantly different were video ($x^2$=16.81, p<.001), webtoon ($x^2$=8.96, p=.011), and test ($x^2$=10.56, p=.005). Among continuing education evaluation methods, the items that were significantly different were multiple-choices ($x^2$=9.43, p=.009) and OX ($x^2$=6.47, p=.039) based quizzes. Conclusion: Based on the study results, it is necessary to develop a differentiated continuing education program according to practical experience of nurses.

The Effect of Sling Lumbar Stabilization Exercise to Muscle Body Type and Subjective Pain Degree of Men Who Have Sacroiliac Joint Syndrome (8주간의 슬링을 이용한 요부안정화 운동이 천장관절 증후군 남성의 근체형 및 주관적 통증정도에 미치는 효과)

  • Baek, Soon-Gi
    • Journal of Digital Convergence
    • /
    • v.12 no.12
    • /
    • pp.651-658
    • /
    • 2014
  • The purpose of this study is to see how the sling lumbar stabilization exercise affects muscle body type and subjective pain degree of 17 middle-age men who are diagnosed with sacroiliac joint syndrome and investigate the effectiveness. The subjects of this study are patients who have been diagnosed with sacroiliac joint syndrome through tests like X-ray in S Orthopedics in C City and have had chronic lumbar pain for more than 6 months and the before and after results about subjective pain degree through three dimension Moire Muscle Body Type Tester and subjective pain degree through VAS Pain Awareness after sling lumbar stabilization exercise 3 times a week, 30 minutes a time, total 24 times for 8 weeks have revealed the following: The change of muscle body type has been comprehensively improved in the statistics before and after the exercise and the subjective pain degree has also comprehensively decreased in the statistics. Therefore, sling lumbar stabilization exercise is proved to give positive affect to muscle body type and pain improvement of the patients with sacroiliac joint syndrome.

Effects of the Electroless Ni-P Thickness and Assembly Process on Solder Ball Joint Reliability (무전해 Ni-P 두께와 Assembly Process가 Solder Ball Joint의 신뢰성에 미치는 영향)

  • Lee, Ji-Hye;Huh, Seok-Hwan;Jung, Gi-Ho;Ham, Suk-Jin
    • Journal of Welding and Joining
    • /
    • v.32 no.3
    • /
    • pp.60-67
    • /
    • 2014
  • The ability of electronic packages and assemblies to resist solder joint failure is becoming a growing concern. This paper reports on a study of high speed shear energy of Sn-4.0wt%Ag-0.5wt%Cu (SAC405) solder with different electroless Ni-P thickness, with $HNO_3$ vapor's status, and with various pre-conditions. A high speed shear testing of solder joints was conducted to find a relationship between the thickness of Ni-P deposit and the brittle fracture in electroless Ni-P deposit/SAC405 solder interconnection. A focused ion beam (FIB) was used to polish the cross sections to reveal details of the microstructure of the fractured pad surface with and without $HNO_3$ vapor treatment. A scanning electron microscopy (SEM) and an energy dispersive x-ray analysis (EDS) confirmed that there were three intermetallic compound (IMC) layers at the SAC405 solder joint interface: $(Ni,Cu)_3Sn_4$ layer, $(Ni,Cu)_2SnP$ layer, and $(Ni,Sn)_3P$ layer. The high speed shear energy of SAC405 solder joint with $3{\mu}m$ Ni-P deposit was found to be lower in pre-condition level#2, compared to that of $6{\mu}m$ Ni-P deposit. Results of focused ion beam and energy dispersive x-ray analysis of the fractured pad surfaces support the suggestion that the brittle fracture of $3{\mu}m$ Ni-P deposit is the result of Ni corrosion in the pre-condition level#2 and the $HNO_3$ vapor treatment.

Synovial Chondromatosis of the Ankle Joint (족관절에 생긴 활액막성 연골종증)

  • Suh, Jin-Soo;Kim, Ji-Hoon;Kim, Jong-In;Kim, Han-Seong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.1
    • /
    • pp.14-18
    • /
    • 2009
  • Purpose: We evaluated the results of treatment and clinical symptoms of 11 cases of synovial chondromatosis in the ankle joint. Material and Method: From February 2001 to May 2008, 11 cases with synovial chondromatosis involving ankle joint underwent surgical treatment. There were 5 males and 6 females. The average age at surgery was 51 years. The average follow-up period was 42 months. Duration from onset of symptom to treatment was 117 months. Chief complaints of patients, 9 cases were pain and 1 case was mass like lesion, 1 case was found on x-ray. Preoperatively, all cases were evaluated on simple x-ray, 4 cases on CT, 4 cases on MRI and 1 case on ultrasonogram. 10 cases underwent synovectomy and loose body removal. 5 cases of 10 cases underwent open synovectomy and loose body removal and arthrosocpic surgery. 4 cases of 10 cases underwent only open synovectomy and loose body removal and 1 case of 10 cases underwent only arthroscopic surgery. 1 case underwent tibiotalar arthrodesis. Results: The location of loose bodies was 7 cases on posterior and 4 cases on anterior and 4 case on lateral and 3 cases on multiple site. Postoperatively, all patients showed marked clinical improvement and had subjective satisfaction except reoperation 2 cases and arthrodesis 1 case. AOFAS score of all patients was average 82.2. Conclusion: Clinical results of the synovial chondromatosis of ankle joint were satisfactory. More accurate preoperative evaluation is required to achieve prevention of postoperative recurrence and better outcome.

  • PDF

Numerical Study of High-strength Steel CHS X-joints Including Effects of Chord Stresses (주관응력효과를 고려한 고강도강 X형 원형강관접합부의 수치해석 연구)

  • Kim, Seon Hu;Lee, Cheol Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.30 no.2
    • /
    • pp.115-126
    • /
    • 2018
  • Internationally representative steel design standards have forbidden or limited the application of high-strength steels to tubular joints, partly because of concerns about their unique material characteristics such as high yield ratio. Most of design standards stipulate that for steels whose yield strengths exceed 355 or 360 MPa, the strength equations cannot be utilized or strength reduction factor below 1.0 should be multiplied. However, the mechanical background behind these limitations is not clear. Experimental testing of high-strength steel CHS (circular hollow section) X-joints recently conducted by the authors also clearly indicated that the current limitations might be unduly conservative. As a continuing work, extensive, test-validated numerical analyses were made to investigate the behavior of high-strength steel CHS X-joint under axial compression. Three steel grades covering ordinary to very high strength steels were considered in the analysis. Again it was found that the high strength penalty to the joint strength in current standards is too severe and needs to be relaxed. The high-strength steel joints under the effects of chord stress generally showed higher strength than the ordinary steel joints and their strengths were conservatively predicted by current standards. It is also emphasized that current format of the CHS X-joint strength equation does not reflect observed behavior and needs to be recast.

The Solderability and Mechanical Properties of In, Bi Added Sn-9Zn/Cu Joint (In, Bi가 첨가된 Sn-9wt.%Zn/Cu 접합부의 납땜성 및 기계적 성질)

  • Baek, Dae-Hwa;Lee, Kyung-Ku;Lee, Doh-Jae
    • Journal of Korea Foundry Society
    • /
    • v.20 no.2
    • /
    • pp.116-121
    • /
    • 2000
  • Interfacial reaction and mechanical properties between Sn-Zn-X ternary alloys(X : 3wt.%In, 4wt.%Bi) and Cu-substrate were studied. Cu/solder joints were subjected to aging treatments for up to 50days to see interfacial reaction at $100^{\circ}C$ and then were examined changes of microstructure and interfacial compound by optical microscopy, SEM and EDS. Cu/solder joints were aged to 30days and then loaded to failure at cross head speed of 0.3 mm $min^{-1}$ to measure tensile strength. According to the results of the solderability test, additions of In and Bi in the Sn-9wt.%Zn solder improve the wetting characteristics of the alloy and lower the melting temperature. Through the EDS and XRD analysis of Cu/Sn-9wt.%Zn solder joint, it was concluded that the intermetallic compound was the ${\gamma}-Cu_5Zn_8$ phase. Cu-Zn intermetallics at Cu/solder interfaces played an important role in both the microstructure evolution and failure of solder joints. Cu/solder joint strength was decreased by aging treatment, and those phenomenon was closely related to the thickening of intermetallic layer at Cu/solder joints.

  • PDF

Laser Welding of Seal Tube for Instrumented Irradiation Fuel Test (계장핵연료 조사시험용 실튜브 레이저용접기술)

  • Kim Soo-Sung;Lee Chul-Yong;Kim Woong-Ki;Park Geun-Il;Koh Jinh-Yun;Seo Jun-Seok
    • Journal of Welding and Joining
    • /
    • v.23 no.6
    • /
    • pp.43-48
    • /
    • 2005
  • This work was carried out to obtain sound welds and to select a most suitable binary metal joint among three different dissimilar binary metal combinations such as Zr-4/Ta, Mo/Ta and Ti/Ta(seal tube/sensor sheath) joints fur the instrumented nuclear fuel irradiation test. To do this, Taguchi experimental method was employed to optimize the experimental data. In addition, metallography, micro-focus x-ray radiography and hardness test were conducted to examine the welds. From the weld bead appearance, penetration depth and bead width as well as weld defects standpoint, Zr-4/Ta joint is suggested for the circumferential joining between a seal tube and a sensor sheath. The optimized welding parameters based on Zr-4/Ta joint are suggested as well.

An Analysis of Human Knee Joint Motion for Anterior Cruciate Ligament reconstruction (전십자 인대 재건을 위한 인체 슬관절의 굴신 운동 해석)

  • Moon, Byung-Young;Son, Kwon;Park, Jung-Hong;Suh, Jeung-Tak
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.929-934
    • /
    • 2003
  • Three dimensional joint motion data were obtained using precise magnetic sensors and X-ray. Six metal markers were inserted on the femur and the tibia to set the coordinate system. Two magnetic position sensors were used to record motion data and these positions were transformed into the knee motion. The quadriceps muscle was extended in an automatic manner by an extraction machine. Results of the knee motion were the same as the clinical data. The proposed method is found to be reasonable in describing the knee motion so that these motion data can be used to simulate the normal knee joint.

  • PDF