• Title/Summary/Keyword: X-Ray image

Search Result 1,286, Processing Time 0.027 seconds

Microstructure Evaluation of Nano-thick Au-inserted Nickel Silicides (나노급 Au층 삽입 니켈실리사이드의 미세구조 변화)

  • Yoon, Ki-Jeong;Song, Oh-Sung
    • Korean Journal of Materials Research
    • /
    • v.18 no.1
    • /
    • pp.5-11
    • /
    • 2008
  • Thermally evaporated 10 nm-Ni/1 nm-Au/(30 nm-poly)Si structures were fabricated in order to investigate the thermal stability of Au-inserted nickel silicide. The silicide samples underwent rapid thermal annealing at $300{\sim}1100^{\circ}C$ for 40 seconds. The sheet resistance was measured using a four-point probe. A scanning electron microscope and a transmission electron microscope were used to determine the cross-sectional structure and surface image. High-resolution X-ray diffraction and a scanning probe microscope were employed for the phase and surface roughness. According to sheet resistance and XRD analyses, nickel silicide with Au had no effect on widening the NiSi stabilization temperature region. Au-inserted nickel silicide on a single crystal silicon substrate showed nano-dots due to the preferred growth and a self-arranged agglomerate nano phase due to agglomeration. It was possible to tune the characteristic size of the agglomerate phase with silicidation temperatures. The nano-thick Au-insertion was shown to lead to self-arranged microstructures of nickel silicide.

A Measurement Method of Internal Defects of Pressure Vessles by Using Real-Time Holographic Interferometry (실시간 홀로그래픽 간섭법을 이용한 압력용기의 내부결함 측정법)

  • Moon, Sang-Joon;Kang, Young-June;Baik, Sung-Hoon;Kim, Cheol-Jung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.4
    • /
    • pp.1233-1240
    • /
    • 1996
  • Conventional measurement methods using ultrasonic wave or x-ray, eddy current for non-destructive testing(NDT) in nuclear power plants and other industrial plants have been utilized as the method of contact with objects to be inspected. For this reason these methods require relatively much time and inspection area is limited by the location of probe or film. But holograpic interferometry which is a non-contact optical measurement method using a coherent light source has an advantage that quantative measurement can be performed at a time. In this paper a new method using realtime holographic interfreometry and image processing for detecting internal flaws of pressure vessels is presented.

Hair thickness measuring scheme based on portable camera image (포터블 카메라 영상 기반 모발 두께 측정 기법)

  • Kim, Hyungjun;Kim, Woogeol;Rew, Jehyeok;Hwang, Eenjun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.1420-1423
    • /
    • 2015
  • 기존의 영상처리 및 컴퓨터 비전 기술은 X-ray, 군사용 사진, CCTV 영상과 같은 제한적인 상황에서 주로 사용되었다. 스마트폰이 보급되면서 고해상도의 사진을 어디서든 촬영할 수 있게 되었고, 고성능 디바이스를 이용하여 촬영된 영상을 즉시 가공 및 처리가 가능하게 되었다. 그 결과 영상처리 기술이 이전보다 다양하고 좀 더 일반적인 분야에서도 쓰이게 되었다. 그러나 영상처리 기술은 조건이 제한될수록 처리가 용이하며, 일반적인 이미지들을 처리하기 위해서는 고려해야 할 사항이 많다. 특히 두피 영상 분석의 경우 머리카락이 겹치는 부분이나 그림자, 머리카락이 밀집하여 상대적으로 어두워지는 부분 등을 고려해야 하는 어려움이 있으며 현재까지 영상처리를 이용한 두피영상 분석에 대한 연구는 많지 않은 것이 현실이다. 본 논문에서는 스마트폰에 부착하는 포터블 카메라로 촬영된 두피영상을 분석하여 모발의 두께를 측정하는 기법을 제시한다. 먼저 영상에 대한 전처리로 Contrast stretching과 이 진화 과정을 수행한다. 얻어진 이진화 영상에 대해 머리카락의 Skeleton을 추출하고 각 pixel의 각도(angle)를 이용하여 법선을 구한다. 계산된 법선과 머리카락 사이의 교점을 구한 후 두 점사이의 거리를 통해 모발의 두께를 계산한다. 계산된 두께와 현미경을 이용하여 측정한 모발의 실제 두께와 비교하여 제안된 기법의 정확도를 평가한다.

Diagnosis and Treatment of Patient with Radiopaque Material in Temporomandibular Joint : Case Report (측두하악관절 내에 방사선 불투과성 물질을 가지 환자의 진단과 치료 : 증례보고)

  • Yang, Dong-Gul;Choi, Jong-Hoon;Kim, Chong-Youl
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.2
    • /
    • pp.215-221
    • /
    • 2000
  • A 69-year-old male pateint was admitted for discomfort on right temporomandibular joint during opening, closing and chewing that started few months ago. The patient had no special medical history except for lung tuberculosis approximately 30 years ago and nothing specific appeared on a physical exam taken 2 months ago. Clinical tests show that mouth opening of 53mm which was normal and no joint sound, deviation, pain during opening. But tenderness to palpation on Rt masseter muscle and pain existed on Rt temporomandibular joint during loading test on the right joint. No pain existed during resistance test and protrusion and range of lateral movement was normal. Rt temporomandibular joint was not swollen and no palpable mass was observed. No previous trauma history to the face existed. On X-ray calcific material existed in the joint cavity and on CT image, approximately 2mm sized calcific material appeared on the Rt temporomandibular joint but no change in bone appeared on the condyle nor the temporal bone. The patient was diagnosed as loose body, and the symptoms were relived after 2 physical therapies and is under regular check ups. The purpose of this case is to review disease that cause loose bodies.

  • PDF

Three-Dimensional Metal Complex Host with Alternating Arrangement of the Occupied and Vacant Channels. The Crystal Structure of Cd(NH₂CH(CH₃)CH₂NH₂)Ni(CN)₄· 0.25G (G=$CH_3C_6H_5, p-(CH_3)_2C_6H_4$)

  • 박기민;이욱;Toschitake Iwamoto
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.10
    • /
    • pp.919-924
    • /
    • 1996
  • Crystal structure of two inclusion compounds Cd(pn)Ni(CN)4·0.25G (G=toluene and p-xylene, pn=1,2-diaminopropane) have been determined from single-crystal X-ray diffraction data; toluene clathrate: monoclinic P21/n, a=13.838(6), b=26.893(5), c= 7.543(5) Å, γ=90.92(3)°, Z=4, R=0.0616; p-xylene clathrate: monoclinic P21/n, a=13.895(2), b=26.900(3), c=7.613(1) Å, γ=91.06(1)°, Z=4, R=0.0486. The host structures determined for toluene- and pxylene-guest clathrates are substantially identical to the U-type structures observed for the straight chain aliphatic-guest clathrates. However, the alternating arrangement of occupied channels with the guest molecules and vacant channels appears in the host structure. The non-centrosymmetric toluene molecules are distributed about the inversion center to give an image like p-xylene molecule. The guests, toluene and p-xylene, prefer the U-type channel, favoring the interaction between the π-electrons of the aromatic ring and the pn-amino groups to hold the aromatic ring vertical to the cyanometallate meshes.

Atomic Force Microscopy Study of Conducting Layered Transition Metal Ditellurides

  • Kim Sung-Jin;Park So-Jung;Oh Hoon-Jung;Jeon, Il Cheol;Song Sunae
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.12
    • /
    • pp.1098-1103
    • /
    • 1994
  • Atomic force microscopy (AFM) images of two conducting layered transition-metal ditellurides, $TaTe_2$ and $Ta_{0.5}$$V_{0.5}$$Te_2$, were examined and their surface and bulk structural features were compared. All the measured unit cell parameters from AFM image were consistent and in complete agreement with the results of the X-ray diffraction. The microscopic structures of corrugated surface tellurium sheets were strongly affected by the modification of metal double zig-zag chains underneath Te surface. Large difference in the height amplitudes of AFM images in $TaTe_2$ and $Ta_{0.5}$$V_{0.5}$$Te_2$ phases was observed and this reflects large difference in the surface electron densities of two phases. On surface, the shorter intralayer Te…Te contacts in $TaTe_2$ induce more electron transfer from Te p-block bands to Ta d-block bands, thus electron density on surface observed in $TaTe_2$ is much lower than that of $Ta_{0.5}$$V_{0.5}$$Te_2$. However, in bulk, interlayer Te…Te contacts in V substituted phase are shorter than those in $TaTe_2$ phase, thus tellurium-to-metal electron transfer occurs more easily in $Ta_{0.5}$$V_{0.5}$$Te_2$ phase.

Design of a single-pixel photon counter using a self-biased folded cascode operational amplifier (자체 바이어스를 갖는 Folded Cascode OP Amp를 사용한 Single Pixel Photon Counter 설계)

  • Jang, Ji-Hye;Hwang, Yoon-Guem;Kang, Min-Cheol;Jeon, Sung-Chae;Huh, Young;Ha, Pan-Bong;Kim, Young-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.678-681
    • /
    • 2009
  • A single-pixel photon counter is designed using a folded cascode CMOS operational amplifier which is self-biased. Since there is no need for a voltage bias circuit, the layout area and power consumption of the designed counter are reduced. The signal voltage of the designed charge sensitive amplifier (CSA) with the MagnaChip $0.18{\mu}m$ CMOS process is simulated to be 138mv, near the theoretical voltage of 151mV. And the layout area of the designed counter is $100{\mu}m{\times}100{\mu}m$.

  • PDF

Validity and Reliability of Ultrasound Measurement of Knee Joint Space Width in Individuals With Knee Osteoarthritis

  • Kim, Geon;Cha, Young-joo;Shin, Ji-won;You, Sung-hyun
    • Physical Therapy Korea
    • /
    • v.26 no.1
    • /
    • pp.60-66
    • /
    • 2019
  • Background: Knee osteoarthritis (OA) is a single most arthritic disease. Knee joint space width (JSW) is commonly used for grading severity of knee OA. However, previous studies did not established criterion validity and test-retest reliability of ultrasound (US) image for measuring JSW. Objects: The aim of this study was to establish criterion validity and test-retest reliability of US measurement of medial and lateral knee JSW. Methods: Twenty-nine subjects with knee OA were participated. The US and X-ray were used to measure knee JSW. One sample Kolmogorov-Smirnov test was used to confirm the data normal distribution. Pearson correlation coefficient and ICC were used to calculated and establish criterion validity and test-retest reliability, respectively. Results: US measurement of medial and lateral knee JSW was highly correlated with radiographic imaging measure (r=.714 and .704, respectively). Test-retest reliabilities of medial and lateral knee JSW were excellent correlated (ICC=.959 for medial side and .988 for lateral side, respectively). Conclusion: US may be valid tool to measure knee JSW.

Mid-level Feature Extraction Method Based Transfer Learning to Small-Scale Dataset of Medical Images with Visualizing Analysis

  • Lee, Dong-Ho;Li, Yan;Shin, Byeong-Seok
    • Journal of Information Processing Systems
    • /
    • v.16 no.6
    • /
    • pp.1293-1308
    • /
    • 2020
  • In fine-tuning-based transfer learning, the size of the dataset may affect learning accuracy. When a dataset scale is small, fine-tuning-based transfer-learning methods use high computing costs, similar to a large-scale dataset. We propose a mid-level feature extractor that retrains only the mid-level convolutional layers, resulting in increased efficiency and reduced computing costs. This mid-level feature extractor is likely to provide an effective alternative in training a small-scale medical image dataset. The performance of the mid-level feature extractor is compared with the performance of low- and high-level feature extractors, as well as the fine-tuning method. First, the mid-level feature extractor takes a shorter time to converge than other methods do. Second, it shows good accuracy in validation loss evaluation. Third, it obtains an area under the ROC curve (AUC) of 0.87 in an untrained test dataset that is very different from the training dataset. Fourth, it extracts more clear feature maps about shape and part of the chest in the X-ray than fine-tuning method.

Characterization of jute fibre reinforced pine rosin modified soy protein isolate green composites

  • Sakhare, Karishma M.;Borkar, Shashikant P.
    • Advances in materials Research
    • /
    • v.11 no.3
    • /
    • pp.191-209
    • /
    • 2022
  • Very slow degradation of synthetic based polymers has created a severe environmental issue that increased awareness towards research in polymers of biodegradable property. Soy protein isolate (SPI) is a natural biopolymer used as matrix in green composites but it has limitations of low mechanical properties and high water sensitivity. To enhance mechanical properties and reduce water sensitivity of Jute-SPI composites, SPI was modified with pine rosin which is also a natural cross-linking agent. 30% glycerol on the weight basis of a matrix was used as a plasticizer. The fibre volume fraction was kept constant at 0.2 whereas the pine rosin in SPI ranged from 5% to 30% of the matrix. The effects of pine rosin on mechanical, thermal, water sensitivity and surface morphology have been characterized using various techniques. The mechanical properties and water absorbency were found to be optimum for 15% pine rosin in Jute-SPI composite. Therefore, Jute-SPI composite without pine rosin and with 15% pine rosin were chosen for investigation through characterization by Fourier transforms infrared spectroscopy (FTIR), Thermo-gravimetric analysis (TGA), X-Ray diffraction (XRD) and Scanning electron microscope (SEM). The surface morphology of the composite was influenced by pine rosin which is shown in the SEM image. TGA measurement showed that the thermal properties improved due to the addition of pine rosin. Antimicrobial test showed antimicrobial property in the composite occurring 15% pine rosin. The research paper concludes that the modification of SPI resin with an optimum percentage of pine rosin enhanced mechanical, thermal as well as water-resistant properties of jute fibre reinforced composites.