• Title/Summary/Keyword: X-Ray computed tomography

Search Result 701, Processing Time 0.026 seconds

Improvement of Pneumonia in a Patient with Non-Small Cell Lung Cancer Treated with Herbal Medicine after Cessation of Antibiotics - a Case Report

  • Song, Si Yeon;Jeon, Hyeonjin;Lee, Sookyung
    • The Journal of Korean Medicine
    • /
    • v.38 no.2
    • /
    • pp.78-84
    • /
    • 2017
  • A 73-year-old non-small cell lung cancer (NSCLC) patient admitted due to cough, sputum, and dyspnea, aggravated a week ago. She was diagnosed as pneumonia based on the assessment of inflammation markers, chest X-ray and sputum culture. Computed tomography (CT) scan was conducted to exclude malignant tumor metastasis. At the initiation of treatment, considering underlying disease and inflammation marker level, herbal medicine and antibiotics were concurrently used and antibiotics had been discontinued after 10days. Using the monotherapy of herbal medicine in the next 6 days, chest X-ray showed remarkably decreased infiltration in right middle lung and right lower lung. This case represented additional improvement of chest X-ray when treated only with herb medicine after termination of antibiotic therapy and demonstrated the possibility of applying herbal medicine in patients with limited use of antibiotics.

On the Development of Digital Radiography Detectors: A Review

  • Kim, Ho-Kyung;Cunningham, Ian Alexander;Yin, Zhye;Cho, Gyu-Seong
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.4
    • /
    • pp.86-100
    • /
    • 2008
  • This article reviews the development of flat-panel detectors for digital radiography based on amorphous materials, Important design parameters and developments are described for the two main components of flat-panel detectors: the X-ray converter and the readout pixel array. This article also introduces the advanced development concepts of new detectors. In addition, the cascaded linear systems method is reviewed because it is a very powerful tool for improving the design and assessment of X-ray imaging detector systems.

A Study on the Fast Image Reconstruction Algorithm for Spiral CT (Spiral CT의 고속 영상재구성 알고리즘에 관한 연구)

  • Heo, Chang-Won;Jin, Seung-Oh;Lee, Jae-Duck;Huh, Young
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3207-3209
    • /
    • 2000
  • X-ray CT(Computed Tomography) has been a good modality for non-invasive diagnosis and recently, Conventional CT has been replaced rapidly with Spiral CT in recent. In X-ray CT, spiral scanning has various advantages such as better image quality, reduced scan time (in a single breath-hold), a lower x-ray dose. But, it requires very fast and high performance image processing system to reconstruct slice images from spiral scanning. This paper describes the fast image reconstruction techniques with filtered back projection from the viewpoints of fast algorithm as well as hardware implementation for real-time imaging.

  • PDF

Analysis of 3D Geometry and Compressive Behavior of Aluminum Open Cell Foam Using X-ray Micro CT (마이크로 X-ray CT를 활용한 알루미늄 개방형 폼의 형상 및 압축 거동 분석)

  • Kim, Y.I.;Kim, J.H.;Lee, J.K.;Kim, D.
    • Transactions of Materials Processing
    • /
    • v.20 no.7
    • /
    • pp.518-523
    • /
    • 2011
  • The three dimensional geometries of an aluminum open cell foam before and after uniaxial compressive loading were investigated using the X-ray micro CT(computed tomography). Aluminum 6101-T6 open cell foams of 10, 20, 40 ppi (pore per inch) were considered in this work. After the serial sectioning CT images of aluminum foams were obtained from non-destructive X-ray images, the exact 3D structure were reproduced and visualized with commercial image processing program. The relative density ratio was around the 7.0 to 9.0 range, the unit cells showed anisotropic shapes having the different dimensional ratios of 1.1 to 1.3 between the rise and the transverse directions. The yield stress increased with the relative density ratio and the volumetric strain increased proportionally with compressive strain. The plateau stress in the compressive stress-strain curve was caused by the buckling of ligaments.

CUDA-based Fast DRR Generation for Analysis of Medical Images (의료영상 분석을 위한 CUDA 기반의 고속 DRR 생성 기법)

  • Yang, Sang-Wook;Choi, Young;Koo, Seung-Bum
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.4
    • /
    • pp.285-291
    • /
    • 2011
  • A pose estimation process from medical images is calculating locations and orientations of objects obtained from Computed Tomography (CT) volume data utilizing X-ray images from two directions. In this process, digitally reconstructed radiograph (DRR) images of spatially transformed objects are generated and compared to X-ray images repeatedly until reasonable transformation matrices of the objects are found. The DRR generation and image comparison take majority of the total time for this pose estimation. In this paper, a fast DRR generation technique based on GPU parallel computing is introduced. A volume ray-casting algorithm is explained with brief vector operations and a parallelization technique of the algorithm using Compute Unified Device Architecture (CUDA) is discussed. This paper also presents the implementation results and time measurements comparing to those from pure-CPU implementation and open source toolkit.

Three Dimensional Dose Planning Using 6MV X-ray and Multiaxial Computed Tomography for Pituitary Adenoma (6MV X-선과 전산화 단층 촬영상을 이용한 뇌하수체 종양 치료계획)

  • Lee, Myung-Za;Choi, Tae-Jin
    • Radiation Oncology Journal
    • /
    • v.3 no.1
    • /
    • pp.59-64
    • /
    • 1985
  • Computation of three dimensional dose distribution using CT image and RT plan was applied to a case of pituitary adenoma. Algorithm was based on two dimensional Tissue Maximun Ratio model extended to the third dimension. The resulting isodose curve of transeverse, coronal and sagittal section was demonstrated. This RT plan allows computation of dose distribution in any arbitarily defined plane in addition to conventional cross sectional view.

  • PDF

Application of portable digital radiography for dental investigations of ancient Egyptian mummies during archaeological excavations: Evaluation and discussion of the advantages and limitations of different approaches and projections

  • Seiler, Roger;Eppenberger, Patrick;Ruhli, Frank
    • Imaging Science in Dentistry
    • /
    • v.48 no.3
    • /
    • pp.167-176
    • /
    • 2018
  • Purpose: In the age of X-ray computed tomography (CT) and digital volume tomography (DVT), with their outstanding post-processing capabilities, indications for planar radiography for the study of the dentition of ancient Egyptian mummies may easily be overlooked. In this article, the advantages and limitations of different approaches and projections are discussed for planar oral and maxillofacial radiography using portable digital X-ray equipment during archaeological excavations. Furthermore, recommendations are provided regarding projections and sample positioning in this context. Materials and Methods: A total of 55 specimens, including 19 skeletonized mandibles, 14 skeletonized skulls, 18 separate mummified heads, and 4 partially preserved mummies were imaged using portable digital X-ray equipment in the course of archaeological excavations led by the University of Basel in the Valley of the Kings between 2009 and 2012. Images were evaluated by 2 authors with regard to the visibility of diagnostically relevant dental structures using a 4-point grading system(Likert scale). Results: Overall, the visibility of diagnostically relevant dental structures was rated highest by both authors on X-ray images acquired using a dental detector. The tube-shift technique in the lateral projections of mandibular dentition achieved the second-best rating, and lateral projections achieved the third-best rating. Conclusion: Conventional planar digital X-ray imaging, due to its ubiquity, remains an excellent method-and often the only practicable one-for examining the skulls and teeth of ancient Egyptian mummies under field conditions. Radiographic images of excellent diagnostic quality can be obtained, if an appropriate methodology regarding the selected projections and sample placement is followed.

Anatomical structure of lingual foramen in cone beam computed tomography (Cone beam형 전산화 단층촬영장치를 이용한 설공의 해부학적 구조)

  • Ki Min-Woo;Hwang Eui-Hwan;Lee Sang-Rae
    • Imaging Science in Dentistry
    • /
    • v.34 no.3
    • /
    • pp.129-136
    • /
    • 2004
  • Purpose: To evaluate whether cone beam computed tomography can depict the distribution, position, frequency, relative vertical dimension, and the diameter of the lingual foramen and direction of lingual bone canal. Materials and Methods : Cone beam computed tomography of mandible was performed on 25 males and 25 females with no history of any orthodontic treatments or any other dental surgeries. A statistical comparison was done on the mean values of males and females. Results: In the location and distribution of lingual foramina, median lingual foramen was found in all subjects and lateral lingual foramen in 58%. In the lateral lingual foramen, bilateral type was found in 28% and unilateral type in 30%. In the number of lingual foramina, median lingual foramen had two foramina and lateral lingual foramen had one foramen, mostly. In the relative mean vertical dimension of lingual foramina, median lingual foramen was 0.03±0.08, and both lateral lingual foramina was 0.20±0.04. The mean diameter of lingual foramina, median lingual foramen was 0.9mm±0.28, right lateral lingual foramen was 0.92mm±0.23, and left lateral lingual foramen was 0.88mm±0.27. The most frequent direction of the lingual bone canals, median lingual bone canal proceeded in anteroinferior direction and lateral lingual bone canal in anterosuperolateral direction. Conclusion : Cone beam computed tomography can be helpful for surgery and implantation on the mandibular area. Radiologist should be aware of this anatomical feature and its possible implications.

  • PDF

Morphological Analysis of Hydraulically Stimulated Fractures by Deep-Learning Segmentation Method (딥러닝 기반 균열 추출 기법을 통한 수압 파쇄 균열 형상 분석)

  • Park, Jimin;Kim, Kwang Yeom ;Yun, Tae Sup
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.8
    • /
    • pp.17-28
    • /
    • 2023
  • Laboratory-scale hydraulic fracturing experiments were conducted on granite specimens at various viscosities and injection rates of the fracturing fluid. A series of cross-sectional computed tomography (CT) images of fractured specimens was obtained via a three-dimensional X-ray CT imaging method. Pixel-level fracture segmentation of the CT images was conducted using a convolutional neural network (CNN)-based Nested U-Net model structure. Compared with traditional image processing methods, the CNN-based model showed a better performance in the extraction of thin and complex fractures. These extracted fractures extracted were reconstructed in three dimensions and morphologically analyzed based on their fracture volume, aperture, tortuosity, and surface roughness. The fracture volume and aperture increased with the increase in viscosity of the fracturing fluid, while the tortuosity and roughness of the fracture surface decreased. The findings also confirmed the anisotropic tortuosity and roughness of the fracture surface. In this study, a CNN-based model was used to perform accurate fracture segmentation, and quantitative analysis of hydraulic stimulated fractures was conducted successfully.

Influence of threshold value of computed tomography on the accuracy of 3-dimensional medical model (전산화단층 촬영상의 임계치가 3차원 의학모델 정확도에 미치는 영향에 대한 연구)

  • Lee Byeong-Do;Lee Wan
    • Imaging Science in Dentistry
    • /
    • v.32 no.1
    • /
    • pp.27-33
    • /
    • 2002
  • Purpose: To evaluate the influence of threshold value of computed tomography on the accuracy of rapid prototyping (RP) medical model Material and Methods : CT datas of a human dry skull were transferred from CT scanner via compact disk to a personal computer (PC). 3-dimensional image reconstruction on PC by V-works/sup TM/ 3.0 (CyberMed. Inc.) software and RP models fabrication were followed. 2-RP models were produced by threshold value of 500 and 800 selected in surface rendering process. Linear measurements between arbitrary 12 anatomical landmarks on dry skull, 3-D image model, and 2-RP models were done and compared. Thus, the accuracy of 500 RP and 800RP models was respectively evaluated. Results: There was mean difference (% difference) in absolute value of 2.27 mm (2.73%) between linear measurements of dry skull and 500 RP model. There was mean difference (% difference) in absolute value of 1.94 mm (2.52%) between linear measurements of dry skull and 800 RP model. Conclusion: Slight difference of threshold value in rendering process of 3-D modelling made a influence on the accuracy of RP medical model.

  • PDF