• 제목/요약/키워드: X-Ray computed tomography

검색결과 701건 처리시간 0.029초

Tc-99m hydroxymethylene diphosphonate scintigraphy, computed tomography, and magnetic resonance imaging of osteonecrosis in the mandible: Osteoradionecrosis versus medication-related osteonecrosis of the jaw

  • Ogura, Ichiro;Sasaki, Yoshihiko;Sue, Mikiko;Oda, Takaaki;Kameta, Ayako;Hayama, Kazuhide
    • Imaging Science in Dentistry
    • /
    • 제49권1호
    • /
    • pp.53-58
    • /
    • 2019
  • Purpose: To present characteristic findings of Tc-99m hydroxymethylene diphosphonate (HMDP) scintigraphy, computed tomography (CT), and magnetic resonance (MR) imaging for osteonecrosis in the mandible, especially osteoradionecrosis(ORN) and medication-related osteonecrosis of the jaw(MRONJ). Materials and Methods: Thirteen patients with MRONJ and 7 patients with ORN in the mandible underwent Tc-99m HMDP scintigraphy, CT, and MR imaging (T1-weighted images[T1WI], T2-weighted images[T2WI], short inversion time inversion recovery images[STIR]), diffusion-weighted images[DWI], and apparent diffusion coefficient [ADC] mapping). The associations of scintigraphy, CT, and MR imaging findings with MRONJ and ORN were analyzed using the chi-square test with the Pearson exact test. Results: Thirteen patients with MRONJ and 7 patients with ORN in the mandible showed low signal intensity on T1WI and ADC mapping, high signal intensity on STIR and DWI, and increased uptake on scintigraphy. Periosteal bone proliferation on CT was observed in 69.2% of patients with MRONJ(9 of 13) versus 14.3% of patients with ORN(1 of 7)(P=0.019). Conclusion: This study presented characteristic imaging findings of MRONJ and ORN on scintigraphy, CT, and MR imaging. Our results suggest that CT can be effective for detecting MRONJ and ORN.

Prognosis in case of nerve disturbance after mandibular implant surgery in relation to computed tomography findings and symptoms

  • Na, Ji Yeon;Han, Sang-Sun;Jeon, KugJin;Choi, Yoon Joo;Choi, Seong Ho;Lee, Chena
    • Journal of Periodontal and Implant Science
    • /
    • 제49권2호
    • /
    • pp.127-135
    • /
    • 2019
  • Purpose: The aim of this study was to evaluate the computed tomography (CT) imaging findings and clinical symptoms of patients who complained of neurosensory disturbances after mandibular implant surgery, and to investigate the relationships of these parameters with the prognosis for recovery. Methods: CT scans were reviewed in 56 patients with nerve disturbance after mandibular implant surgery. Two oral radiologists classified the imaging findings into intrusion, contact, close, and separate groups according to the distance from the inferior border of the implant to the roof of the mandibular canal (MC). The symptoms of 56 patients were classified into 8 groups and the frequency of each group was investigated. Patients were categorized according to symptom improvement into no recovery and recovery groups, and the relationships of recovery with the CT classification and specific symptom groups were analyzed. Results: Thirty-eight of the 56 nerve disturbance cases showed improvement. The close and separate groups in the CT classification had a strong tendency for recovery (90.9% and 81.8%, respectively) (P<0.05). Although the lowest recovery rate was found in the intrusion group, it was non-negligible, at 50%. The 6 patients with a worm crawling feeling all improved, while the 8 cases with a tightening sensation showed the lowest recovery rate, at 12.5%, and the symptom of a tightening sensation occurred only in the intrusion and contact groups. Conclusions: The closer the implant fixture was to the MC on CT images, the less likely the patient was to recover. Regarding paresthesia symptoms, while a worm crawling feeling is thought to be a predictor of recovery, a tightening sensation appeared to be associated with a lower recovery rate.

Impact of the spatial orientation of the patient's head, metal artifact reduction, and tube current on cone-beam computed tomography artifact expression adjacent to a dental implant: A laboratory study using a simulated surgical guide

  • Matheus Barros-Costa;Julia Ramos Barros-Candido;Matheus Sampaio-Oliveira;Deborah Queiroz Freitas;Alexander Tadeu Sverzut;Matheus L Oliveira
    • Imaging Science in Dentistry
    • /
    • 제54권2호
    • /
    • pp.191-199
    • /
    • 2024
  • Purpose: The aim of this study was to evaluate image artifacts in the vicinity of dental implants in cone-beam computed tomography (CBCT) scans obtained with different spatial orientations, tube current levels, and metal artifact reduction algorithm (MAR) conditions. Materials and Methods: One dental implant and 2 tubes filled with a radiopaque solution were placed in the posterior region of a mandible using a surgical guide to ensure parallel alignment. CBCT scans were acquired with the mandible in 2 spatial orientations in relation to the X-ray projection plane (standard and modified) at 3 tube current levels: 5, 8, and 11 mA. CBCT scans were repeated without the implant and were reconstructed with and without MAR. The mean voxel and noise values of each tube were obtained and compared using multi-way analysis of variance and the Tukey test(α=0.05). Results: Mean voxel values were significantly higher and noise values were significantly lower in the modified orientation than in the standard orientation (P<0.05). MAR activation and tube current levels did not show significant differences in most cases of the modified spatial orientation and in the absence of the dental implant (P>0.05). Conclusion: Modifying the spatial orientation of the head increased brightness and reduced spatial orientation noise in adjacent regions of a dental implant, with no influence from the tube current level and MAR.

Influence of Heart Rate and Innovative Motion-Correction Algorithm on Coronary Artery Image Quality and Measurement Accuracy Using 256-Detector Row Computed Tomography Scanner: Phantom Study

  • Jeong Bin Park;Yeon Joo Jeong;Geewon Lee;Nam Kyung Lee;Jin You Kim;Ji Won Lee
    • Korean Journal of Radiology
    • /
    • 제20권1호
    • /
    • pp.94-101
    • /
    • 2019
  • Objective: To investigate the efficacy of motion-correction algorithm (MCA) in improving coronary artery image quality and measurement accuracy using an anthropomorphic dynamic heart phantom and 256-detector row computed tomography (CT) scanner. Materials and Methods: An anthropomorphic dynamic heart phantom was scanned under a static condition and under heart rate (HR) simulation of 50-120 beats per minute (bpm), and the obtained images were reconstructed using conventional algorithm (CA) and MCA. We compared the subjective image quality of coronary arteries using a four-point scale (1, excellent; 2, good; 3, fair; 4, poor) and measurement accuracy using measurement errors of the minimal luminal diameter (MLD) and minimal luminal area (MLA). Results: Compared with CA, MCA significantly improved the subjective image quality at HRs of 110 bpm (1.3 ± 0.3 vs. 1.9 ± 0.8, p = 0.003) and 120 bpm (1.7 ± 0.7 vs. 2.3 ± 0.6, p = 0.006). The measurement error of MLD significantly decreased on using MCA at 110 bpm (11.7 ± 5.9% vs. 18.4 ± 9.4%, p = 0.013) and 120 bpm (10.0 ± 7.3% vs. 25.0 ± 16.5%, p = 0.013). The measurement error of the MLA was also reduced using MCA at 110 bpm (19.2 ± 28.1% vs. 26.4 ± 21.6%, p = 0.028) and 120 bpm (17.9 ± 17.7% vs. 34.8 ± 19.6%, p = 0.018). Conclusion: Motion-correction algorithm can improve the coronary artery image quality and measurement accuracy at a high HR using an anthropomorphic dynamic heart phantom and 256-detector row CT scanner.

Economic Scale of Radiation Application in Japan

  • Kume, Tamikazu
    • 방사선산업학회지
    • /
    • 제5권3호
    • /
    • pp.191-196
    • /
    • 2011
  • The economic scale of nuclear application is a good indicator to show how the radiation technology is useful and contribute to improve public welfare and living standard. Recent research in Japan shows that the economic scale of nuclear field was 4,112 B¥ for radiation application(46%) and 4,741 B¥ for nuclear energy (54%) playing a role of "two wheels of one cart" in nuclear field and the total 8,853 B¥ constitutes 1.8% of gross domestic products (GDP). The radiation application consisted of 2,295 B¥ (56%) in industry (semiconductor, sterilization, nondestructive testing, radiation processing of tires, etc.), 1,538 B¥ (37%) in medicine (therapy and diagnosis such as X-ray, nuclear medicine, computed tomography, etc.) and 279 B¥ (7%) in agriculture (mutation breeding, food irradiation, sterile insect technique, etc.). Radiation application by ${\gamma}$-ray, electron beam and ion beam is steadily increasing in Japan.

흉부 둔상환자에서 흉부전산화단층촬영이 진단과 치료에 미치는 영향 (The Effect of a Chest CT Scan on the Treatment and Diagnosis of Major Blunt Chest Trauma)

  • 박일환;오중환;이종국
    • Journal of Chest Surgery
    • /
    • 제42권2호
    • /
    • pp.226-232
    • /
    • 2009
  • 배경: 흉부 둔상은 전체 흉부 손상의 90%정도를 차지하며 외상과 관련된 사망률의 20%를 유발시킨다. 흉분 둔상에 의한 손상 후 이환율과 사망률의 주요 원인은 발견되지 못한 손상이 남아있기 때문이다. 그리하여 흉부전산화단층 촬영은 외상환자의 진단적 검사에서 매우 자주 사용되어져 왔다. 그러나 흉부 컴퓨터 촬영은 가격이 비싸고, 방사선 노출을 증가시킬 수 있다. 이번 연구를 통하여 흉부둔상 환자에서 흉부단순촬영과 비교하여 흉부전산화단층촬영을 통하여 얼마나 더 많은 정보를 얻을 수 있는지 조사해 보고 그리고 흉부 컴퓨터 촬영의 진단과 치료에 있어서의 역할을 알아보고자 한다. 대상 및 방법: 2006년 11월부터 2007년 7월까지 응급실로 내원한 환자 100명을 대상으로 하였다. 이 중 74명의 자동차 관련사고 환자와 26명의 낙상 사고 환자가 있었으며 흉부엑스선과 흉부전산화단층 촬영을 동시에 시행한 환자를 전체 응급실 환자 중에 선택하였다. 자료는 차트를 통하여 혈역학적 소견, 중재적 치료 여부, 손상의 중증도(RTS)와 종류를 조사하였으며, 초기 응급실 내원환자 중 흉부단순촬영과 흉부전산화단층촬영을 시행한 환자를 대상으로 발견되지 못한 병적 소견을 각각 질환별로 분석하였다. 결과: 100예의 환자 중 흉부엑스선 검사상 하나 이상의 병적소견을 보인 환자가 79예였으며 21예의 환자에서는 흉부엑스선 검사상 정상 소견을 보였으며, 이 21예의 환자 중 17예에서 흉부전산화단층촬영상 이상소견이 발견되었다. 흉부엑스선 검사상 발견하지 못한 소견으로는 기흉, 혈흉, 폐좌상, 흉골 골절 등이 있었으며 이러한 병적 소견의 진단은 흉부전산화단층촬영이 흉부엑스선 검사보다 통계적으로 유의하게 우수한 것으로 나타났다. 하지만 치료에 있어서는 흉부전산화촬영 시행 후 발견된 병변으로 흉관삽입술등의 치료를 시행한 환자는 31명에 불과했고 흉관삽입술, 개흉술 등의 흉부외과적인 치료 없이 집중관찰을 위하여 입원한 환자가 42명이었으며, 흉부엑스선촬영과 환자의 이학적 소견으로 진단되어 치료를 시행한 환자가 27명이었다. 결론: 흉부전산화단층촬영은 진단에 있어서 흉부엑스선 촬영보다 통계적으로 의미 있게 진단에 도움이 되는 것을 알 수 있었으나 발견되지 못한 병변이 증가할지라도 치료의 변화와 방법의 변화가 있는 경우는 매우 소수에 불과했다. 그리하여 응급실에서의 흉부전산화단층촬영의 오남용을 막기 위하여 선별적인 흉부전산화단층 촬영을 고려해야 할 것이다.

IEC 60601-1: 3판이 적용된 진단용 X선장치 관련 개별규격의 동향 및 특징 (Features and Trends of IEC Particular Standards for Medical Equipment Related to Diagnostic X-ray Based on IEC 60601-1:2005 Ed. 3.0)

  • 김현지;김정민;최인석;윤용수;서덕남;김정수;김대영;박성용
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제36권1호
    • /
    • pp.1-10
    • /
    • 2013
  • IEC 규격은 유럽, 일본 등 해외 여러 나라에서 자국의 규격으로서 이용되고 있으며, 우리나라에서는 현재 산업표준인 KS 형태와 더불어 강제성을 갖는 식품의약품안전청 고시로서도 발행되고 있다. 전자의료기기에 관한 IEC 규격인 IEC 60601 시리즈의 공통규격(IEC 60601-1:2005)이 3판으로 개정됨에 따라, 보조규격과 개별규격 또한 그에 맞추어 제 개정이 필요하다. IEC 규격의 변화 동향을 파악하는 것은 국내 의료기기 제조 수입업체 및 시험검사기관에서 매우 중요하다. 따라서 본 연구에서는, 진단용X선기기와 관련한 3개 규격 IEC 60601-2-44(CT의 기본안전과 필수성능에 관한 규격), IEC 60601-2-45(유방촬영용X선장치의 기본안전과 필수성능에 관한 규격), IEC 60601-2-54(진단용 X선장치의 기본안전과 필수성능에 관한 개별규격)에 대하여 IEC 60601-1의 3판에 맞추어 제 개정된 최신판의 동향 및 특징을 살펴보고자 하였다. 또한 현행 식품의약품안전청 고시가 IEC 60601-1의 2판이 적용된 개별규격을 참고로 하고 있어, 현행 식품의약품안전청 고시와 대비하여 그 특징을 살펴보았다. IEC 60601-1의 3판이 적용된 진단용X선장치 외 2개의 IEC 개별규격의 특징은 다음과 같다. 1) 기계적 위해요인, 특히 움직이는 부분에 대한 내용이 강화되었다. 2) 환자 선량을 표시 및 기록하도록 명시하고 있다. 3) 잠재적인 위험요소에 대해 체계적으로 관리가 가능한 위험관리 프로세스를 도입하고 있다. 4) 과거 Film-Screen System과 더불어 DR system(digital radiography system)에 대해서도 적용하고 있다. 현재 IEC 60601-1의 3판이 적용된 개별규격이 식품의약품안전청 고시로 개정될 예정이므로, 국내 시험 검사기관 및 의료기기 제조 수입업체 등에 유용한 자료가 되기를 기대한다.

폐종양과 폐암의 병기결정에 대한 양전자단층촬영(PET)의 유용성 -전산화단층촬영 (CT)과의 비교- (Efficacy of Positron Emission Tomography in Diagnosing Pulmonary Tumor and Staging of Lung Cancer : Comparing to Computed Tomography)

  • 김오곤;조중행;성숙환
    • Journal of Chest Surgery
    • /
    • 제36권2호
    • /
    • pp.79-85
    • /
    • 2003
  • 배경: 흉부 전산화 단층촬영(CT)의 폐암 진단율의 한계로 인하여 최근 폐암에 대한 진단과 병기결정에 양전자단층촬영(PET)이 유정한 것으로 알려져 있다. 이에 우리나라 폐암 환자에서 진단 및 병기 결정에 전산화 단층촬영과 양전자단층촬영의 진단율의 차이점과 유용성을 비교하고자 하였다. 대상 및 방법: 1998년 6월부터 1999년 12월까지 흥부 X-선 촬영과 CT에서 폐암이 의심퇴거나 진단된 55명에서, 차 장기에서 폐로 전이된 9명과 폐암수술후 재발된 5명을 제외한 41명을 대상으로 수술전 CT와 PET 소견과 종격동경이나 개흉술로 확진된 조직병리 소견을 비교하였다. 결과: 41명 대상환자 중 폐종양의 조직학적 진단은 악성병변이 35례 (편평세포암 19례, 선암 14례, 선편평세포암 2례)있고, 양성병변은 6례였다. 폐종양의 악성여부에 대한 CT와 PET 두가지 검사의 민감도, 특이도, 정확도는 같았으며 각각 100%, 50%, 92.7%였다. 최종적인 병리적 림프 절군 병기는 N0-Nl 31례, N2 8례, N3 2례 였다. 림프절군 병기가 일치하는 경우는 CT가 31례, PET가 28례였고, CT와 PET의 각간 6례에서 병리학적 림프절 병기보나 낮게 평가되었고, CT의 4례, PET의 7례에서 병기보다 높게 평가되었다. 조직검사가 가능했던 108개비 종격동 림프절군 중 18개 림프절군에서 악성으고 나왔고, 종격동 림프절군 침범여부에 대한 CT와 PET의 민감도, 특이도, 정확도는 각각 39.8%, 93.3%. 84.3%와 61.1%, 90.0%, 85.2% 였다. 종격동 림프절군 대한 CT와 PET 검사를 종합하여 같이 분석하였을 때 민감도 77.8%, 특이도 93.3%, 정확도 90.7%이었다. 결론: 폐종양과 림프절군의 병기 설정에 있어 PET검사는 CT와 비교하여 비슷한 유용성이 있는 건사로 사료되며, CT와 PET두 검사를 같이 시행하여 검토할 때 정착도를 높일 수 있다고 여겨진다.

A Pulmonary Paragonimiasis Case Mimicking Metastatic Pulmonary Tumor

  • Kim, Ki-Uk;Lee, Kwang-Ha;Park, Hye-Kyung;Jeong, Yeon-Joo;Yu, Hak-Sun;Lee, Min-Ki
    • Parasites, Hosts and Diseases
    • /
    • 제49권1호
    • /
    • pp.69-72
    • /
    • 2011
  • Pulmonary paragonimiasis is a relatively rare cause of lung disease revealing a wide variety of radiologic findings, such as air-space consolidation, nodules, and cysts. We describe here a case of pulmonary paragonimiasis in a 27-year-old woman who presented with a 2-month history of cough and sputum. Based on chest computed tomography (CT) scans and fluorodeoxyglucose positron emission tomography (FDG-PET) findings, the patient was suspected to have a metastatic lung tumor. However, she was diagnosed as having Paragonimus westermani infection by an immunoserological examination using ELISA. Follow-up chest X-ray and CT scans after chemotherapy with praziquantel showed an obvious improvement. There have been several reported cases of pulmonary paragonimiasis mimicking lung tumors on FDG-PET. However, all of them were suspected as primary lung tumors. To our knowledge, this patient represents the first case of paragonimiasis mimicking metastatic lung disease on FDG-PET CT imaging.

한국인에 있어 깊은아래배벽동맥(Deep Inferior Epigastric Artery)의 천공지(Perforator)에 관한 해부학적 연구 (Anatomical Study for Vascular Distribution of the Perforator of Deep Inferior Epigastric Artery in Koreans)

  • 김지훈;이백권;이종원;김덕임;한승호
    • Archives of Plastic Surgery
    • /
    • 제35권1호
    • /
    • pp.28-35
    • /
    • 2008
  • Purpose: The pedicle of transverse rectus abdominis myocutaneous(TRAM) flap and deep inferior epigastric arterial perforator flap is deep inferior epigastic artery (DIEA) and accurate anatomic knowledge about perforator of DIEA is very important for the elevation of these flap. The authors investigated a detailed vascular network of perforator of DIEA in Koreans. Methods: 24 fresh cadavers were studied. Among them, 15 were examined based on the plain X-ray examination for the distribution and location of perforator of DIEA. And 9 fresh cadavers were examined based on the 3-dimensional computed tomography(CT) study for the distance between ending point of perforator of DIEA and mother artery, the distance between most medial mother artery and midline, the distance between most lateral mother artery and midline, and the running type of perforators of DIEA. Results: Based on the plain X-ray examination, suitable(external diameter$${\geq_-}0.5mm$$) perforators of DIEA are located between the level of umbilicus and 8 cm below it. Based on the 3D-CT study, average distance between the ending point of perforator of DIEA and the mother artery is 30.26 mm on the left, 28.62 mm on the right, respectively. The average distance between most medial mother artery and midline is 17.13 mm on the left, 15.76 mm on the right, respectively. The average distance between most lateral mother artery and midline is 56.31 mm on the left, 50.90 mm on the right, respectively. The main running course of suitable perforators of DIEA is type a, which is a direct musculocutaneous perforator vessel from main vascular axis passing outward to join the subdermal plexus, directly. Conclusion: 3-dimensional computed tomography study as well as plain X-ray examination provided more accurate and detail informations about perforators of DIEA in Koreans. These informations will help us understand the detailed vascular anatomy and operation with ease and safe in the lower abdomen of Koreans.