• Title/Summary/Keyword: X-Ray computed tomography

Search Result 701, Processing Time 0.028 seconds

Multiple fibro-osseous lesions of the jaws: A report of a rare case with a literature review

  • Makkad, Ramanpal Singh;Naidu, Giridhar S.;Nagi, Ravleen;Sagtani, Alok;Patil, Santosh;Shrivastava, Swatantra
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.461-466
    • /
    • 2021
  • Fibro-osseous lesions are a poorly defined category of conditions affecting the jaws and craniofacial bones, and include developmental lesions, reactive or dysplastic lesions, and neoplasms. Fibrous dysplasia and ossifying fibroma are the 2 main types of fibro-osseous lesions affecting the jaw, and ossifying fibroma is a true benign neoplasm of the bone-forming tissues with several well-recognized variants ranging from innocuous to extensively aggressive lesions. However, multiple simultaneous fibro-osseous lesions of the jaw bones involving all quadrants are exceedingly rare. One such case diagnosed by conventional radiography and computed tomography is discussed here.

Ancient schwannoma in the parotid gland: A case report and review of the literature

  • Young-Eun Kwon
    • Imaging Science in Dentistry
    • /
    • v.53 no.3
    • /
    • pp.239-245
    • /
    • 2023
  • Schwannomas are uncommon neoplasms of neurologic origin that are rare in the salivary glands. A schwannoma that persists for a long time is referred to as an ancient schwannoma if it is accompanied by degenerative changes on histology. The case described herein involved a 37-year-old man with an ancient schwannoma that had persisted for 20 years in his right parotid gland. Clinically, the lesion presented with swelling and pain. Computed tomography revealed a well-defined, multilocular enhanced lesion. T2-weighted magnetic resonance images displayed multilocular hyperintensity, while T1-weighted images showed a high signal at the lobulated margin and a homogeneous low signal internally. The preoperative diagnosis, based on the lesion's location and imaging diagnosis, was Warthin's tumor. However, a biopsy conducted after surgical excision identified the lesion as a schwannoma with cystic degeneration. This report also presents a summary of the characteristics of rare cases of schwannoma in the major salivary gland based on this case and a literature review.

2019 Novel Coronavirus (COVID-19) Pneumonia: Serial Computed Tomography Findings

  • Jiangping Wei;Huaxiang Xu;Jingliang Xiong;Qinglin Shen;Bing Fan;Chenglong Ye;Wentao Dong;Fangfang Hu
    • Korean Journal of Radiology
    • /
    • v.21 no.4
    • /
    • pp.501-504
    • /
    • 2020
  • From December 2019, Coronavirus disease 2019 (COVID-19) pneumonia (formerly known as the 2019 novel Coronavirus [2019-nCoV]) broke out in Wuhan, China. In this study, we present serial CT findings in a 40-year-old female patient with COVID-19 pneumonia who presented with the symptoms of fever, chest tightness, and fatigue. She was diagnosed with COVID-19 infection confirmed by real-time reverse-transcriptase-polymerase chain reaction. CT showed rapidly progressing peripheral consolidations and ground-glass opacities in both lungs. After treatment, the lesions were shown to be almost absorbed leaving the fibrous lesions.

Mediastinal Emphysema, Giant Bulla, and Pneumothorax Developed during the Course of COVID-19 Pneumonia

  • Ruihong Sun;Hongyuan Liu;Xiang Wang
    • Korean Journal of Radiology
    • /
    • v.21 no.5
    • /
    • pp.541-544
    • /
    • 2020
  • The coronavirus disease 2019 (COVID-19) pneumonia is a recent outbreak in mainland China and has rapidly spread to multiple countries worldwide. Pulmonary parenchymal opacities are often observed during chest radiography. Currently, few cases have reported the complications of severe COVID-19 pneumonia. We report a case where serial follow-up chest computed tomography revealed progression of pulmonary lesions into confluent bilateral consolidation with lower lung predominance, thereby confirming COVID-19 pneumonia. Furthermore, complications such as mediastinal emphysema, giant bulla, and pneumothorax were also observed during the course of the disease.

Small Solitary Ground-Glass Nodule on CT as an Initial Manifestation of Coronavirus Disease 2019 (COVID-19) Pneumonia

  • Tianyi Xia;Jiawei Li;Jiao Gao;Xunhua Xu
    • Korean Journal of Radiology
    • /
    • v.21 no.5
    • /
    • pp.545-549
    • /
    • 2020
  • The 2019 novel coronavirus (2019-nCoV) outbreak in Wuhan, Hubei Province, China in 2019 led to large numbers of people being infected and developing atypical pneumonia (coronavirus disease 2019, COVID-19). Typical imaging manifestations of patients infected with 2019-nCoV has been reported, but we encountered an atypical radiological manifestation on baseline computed tomography (CT) images in three patients from Wuhan, China infected with the 2019-nCoV. Surprisingly, the only similar CT finding was a solitary sub-centimeter ground-glass nodule adjacent to bronchovascular bundles, which could be easily overlooked. In addition, the follow-up images in these patients showed how COVID-19 pneumonia evolved from these small nodules. The radiologic manifestation of the three cases will expand contemporary understanding of COVID-19.

The location of midfacial landmarks according to the method of establishing the midsagittal reference plane in three-dimensional computed tomography analysis of facial asymmetry

  • Kim, Min Sun;Lee, Eun Joo;Song, In Ja;Lee, Jae-Seo;Kang, Byung-Cheol;Yoon, Suk-Ja
    • Imaging Science in Dentistry
    • /
    • v.45 no.4
    • /
    • pp.227-232
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the influence of methods of establishing the midsagittal reference plane (MRP) on the locations of midfacial landmarks in the three-dimensional computed tomography (CT) analysis of facial asymmetry. Materials and Methods: A total of 24 patients (12 male and 12 female; mean age, 22.5 years; age range, 18.2-29.7 years) with facial asymmetry were included in this study. The MRP was established using two different methods on each patient's CT image. The x-coordinates of four midfacial landmarks (the menton, nasion, upper incisor, and lower incisor) were obtained by measuring the distance and direction of the landmarks from the MRP, and the two methods were compared statistically. The direction of deviation and the severity of asymmetry found using each method were also compared. Results: The x-coordinates of the four anatomic landmarks all showed a statistically significant difference between the two methods of establishing the MRP. For the nasion and lower incisor, six patients (25.0%) showed a change in the direction of deviation. The severity of asymmetry also changed in 16 patients (66.7%). Conclusion: The results of this study suggest that the locations of midfacial landmarks change significantly according to the method used to establish the MRP.

APPLICATION OF A DUAL-ENERGY MONOCHROMATIC XRAY CT ALGORITHM TO POLYCHROMATIC X-RAY CT: A FEASIBILITY STUDY

  • Chang, S.;Lee, H.K.;Cho, G.
    • Nuclear Engineering and Technology
    • /
    • v.44 no.1
    • /
    • pp.61-70
    • /
    • 2012
  • In this study, a simple post-reconstruction dual-energy computed tomography (CT) method is proposed. A dual-energy CT algorithm for monochromatic x-rays was adopted and applied to the dual-energy CT of polychromatic x-rays by assigning a representative mono-energy. The accuracy of algorithm implementation was tested with mathematical phantoms. To test the sensitivity of this algorithm to the inaccuracy of representative energy value in energy values, a simulation study was performed with mathematical phantom. To represent a polychromatic x-ray energy spectrum with a single-energy, mean energy and equivalent energy were used, and the results were compared. The feasibility of the proposed method was experimentally tested with two different micro-CTs and a test phantom made of polymethyl methacrylate (PMMA), water, and graphite. The dual-energy calculations were carried out with CT images of all possible energy pairs among 40, 50, 60, 70, and 80 kVp. The effective atomic number and the electron density values obtained from the proposed method were compared with theoretical values. The results showed that, except the errors in the effective atomic number of graphite, most of the errors were less than 10 % for both CT scanners, and for the combination of 60 kVp and 70 kVp, errors less than 6.0 % could be achieved with a Polaris 90 CT. The proposed method shows simplicity of calibration, demonstrating its practicality and feasibility for use with a general polychromatic CT.

A study of incisive canal using a cone beam computed tomography (cone beam형 전산화 단층촬영장치를 이용한 절치관의 연구)

  • Kim Gyu-Tae;Hwang Eui-Hwan;Lee Sang-Rae
    • Imaging Science in Dentistry
    • /
    • v.34 no.1
    • /
    • pp.7-12
    • /
    • 2004
  • Purpose: To investigate the anatomical structure of the incisive canal radiographically by a cone beam computed tomography. Materials and Methods: 38 persons (male 26, female 12) were chosen to take images of maxillary anterior region in dental CT mode using a cone beam computed tomography. The tube voltage were 65, 67, and 70kVp, the tube current was 7 mA, and the exposure time was 13.3 seconds. The FH plane of each person was parallel to the floor. The images were analysed on the CRT display. Results: The mean length of incisive canal was 15.87 mm±2.92. The mean diameter at the side of palate and nasal fossa were 3.49 mm±0.76 and 3.89 mm± 1.06, respectively. In the cross-sectional shape of incisive canal, 50% were round, 34.2% were ovoid, and 15.8% were lobulated. 87% of incisive canal at the side of nasal fossa have one canal, 10.4% have two canals, and 2.6% have three canals, but these canals were merged into one canal in the middle portion of palate. The mean angles of the long axis of incisive canal and central incisor to the FH plane were 110.3°±6.96 and 117.45°±7.41, respectively. The angles of the long axis of incisive canal and central incisor to the FH plane were least correlated (r= 0.258). Conclusion : This experiment suggests that a cone beam computed radiography will be helpful in surgery or implantation on the maxillary incisive area.

  • PDF

Three-dimensional intraoperative computed tomography imaging for zygomatic fracture repair

  • Peleg, Oren;Ianculovici, Clariel;Shuster, Amir;Mijiritsky, Eitan;Oz, Itay;Kleinman, Shlomi
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.47 no.5
    • /
    • pp.382-387
    • /
    • 2021
  • Objectives: Zygomatic complex (ZMC) fractures comprise up to 40% of all facial fractures. Misaligned bone fragments and misplaced fixation hardware traditionally detected postoperatively on plain radiographs of the skull might require re-operation. The intraoperative O-Arm (Medtronic, USA) is a three-dimensional (3D) computed tomographic imaging system. Materials and Methods: This retrospective single-center study evaluated the utility of O-Arm scanning during corrective surgeries for ZMC and zygomatic arch (ZA) fractures from 2018 to 2020. Three females and 16 males (mean age, 31.52 years; range, 22-48 years) were included. Fracture instability (n=6) and facial deformity (n=15) were the most frequent indications for intraoperative 3D O-Arm scan. Results: The images demonstrated that all fracture lines were properly reduced and fixed. Another scan performed at the end of the fixation or reduction stage, however, revealed suboptimal results in five of the 19 cases, and further reduction and fixation of the fracture lines were required. Conclusion: Implementation of an intraoperative O-Arm system in ZMC and ZA fracture surgeries assists in obtaining predictable and accurate results and obviates the need for revision surgeries. The device should be considered for precise operations such as ZMC fracture repairs.

A comparison of canal centering abilities of four root canal instrument systems using X-ray micro-computed tomography (방사선 미세컴퓨터단층촬영을 이용한 네 종류 file systems의 중심유지능에 관한 비교)

  • Ko, Hye-Suk;You, Heyon-Mee;Park, Dong-Sung
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.61-68
    • /
    • 2007
  • The purpose of this study was to compare the centering abilities of four root canal instrument systems and the amounts of dentin removed after root canal shaping using them. The mesial canals of twenty extracted mandibular first molars having $10-20^{\circ}$ curvature were scanned using X-ray micro-computed tomography (XMCT)-scanner before root canals were instrumented. They were divided into four groups (n = 10 per group). In Group 1, root canals were instrumented by the step-back technique with stainless steel K-Flexofile after coronal flaring. The remainders were instrumented by the crown-down technique with Profile (Group 2), ProTaper (Group 3) or K3 system (Group 4). All canals were prepared up to size 25 at the end-point of preparation and scanned again. Scanned images were processed to reconstruct three-dimensional images using three-dimensional image software and the changes of total canal volume were measured. Pre-and post-operative cross-sectional images of 1, 3, 5, and 7 mm from the apical foramen were com pared. For each level, centering ratio were calculated using Adobe Photoshop 6.0 and image software program. ProTaper and K3 systems have a tendency to remove more dentin than the other file systems. In all groups, the lowest value of centering ratio at 3 mm level was observed. And except at 3 mm level, ProTaper system made canals less centered than the other systems (p < 0.05).