• 제목/요약/키워드: X-Ray CT

검색결과 960건 처리시간 0.023초

후종격동 갑상선종;1례 보고 (Posterior Mediastinal Goiter - A Case Report -)

  • 조용준
    • Journal of Chest Surgery
    • /
    • 제25권10호
    • /
    • pp.1116-1120
    • /
    • 1992
  • Posterior mediastinal goiter extending to carotid sheath posteriorly is rare repoted case. Recently we experienced huge posterior mediastinal goiter with compressin of trachea in 57-year old male, The patient that complained of dyspnea referred to our hospital for further evaluation of mediasitnal tumor. We confirmed huge secondary posterior mediastinal intrathoracic goiter with diagnostic methods following by chest X-ray, thyroid scan, chest CT, and CT guided fine needle aspiration biopsy in this patient, and performed operation for excision Exision of posterior mediasitnal goiter performed through initial transeverse cervical incision and additional median sternotomy, and the mass removed completely without any complications. The postoperative course were uneventful.

  • PDF

A method of X-ray source spectrum estimation from transmission measurements based on compressed sensing

  • Liu, Bin;Yang, Hongrun;Lv, Huanwen;Li, Lan;Gao, Xilong;Zhu, Jianping;Jing, Futing
    • Nuclear Engineering and Technology
    • /
    • 제52권7호
    • /
    • pp.1495-1502
    • /
    • 2020
  • A new method of X-ray source spectrum estimation based on compressed sensing is proposed in this paper. The algorithm K-SVD is applied for sparse representation. Nonnegative constraints are added by modifying the L1 reconstruction algorithm proposed by Rosset and Zhu. The estimation method is demonstrated on simulated spectra typical of mammography and CT. X-ray spectra are simulated with the Monte Carlo code Geant4. The proposed method is successfully applied to highly ill conditioned and under determined estimation problems with a good performance of suppressing noises. Results with acceptable accuracies (MSE < 5%) can be obtained with 10% Gaussian white noises added to the simulated experimental data. The biggest difference between the proposed method and the existing methods is that multiple prior knowledge of X-ray spectra can be included in one dictionary, which is meaningful for obtaining the true X-ray spectrum from the measurements.

기흉에서 흉강조영술(Thoracography)의 진단적 가치 (Diagnostic Value of Thoracography in Pneumothorax)

  • 박영식;한재열;장지원
    • Journal of Chest Surgery
    • /
    • 제31권7호
    • /
    • pp.730-734
    • /
    • 1998
  • 배경: 기흉 환자를 수술하기 전에 폐기포의 위치, 숫자, 크기와 모양을 파악하기 위하여 단순 흉부 X선 사진이나 흉부 컴퓨터 단층 촬영등을 이용한다. 단순 흉부 X선 사진은 간편하고 저렴하나 정확도가 낮고, 흉부 컴퓨터 단층 촬영은 정확하나 비용이 많이든다. 그러나 흉강조영술을 이용하면, 폐기포의 상태를 비교적 저렴하고 정확히 파악할수 있으리라 예상되어, 이를 확인하기 위하여 본 임상 실험을 계획하였다. 대상 및 방법: 대상은 개흉이나 흉강내시경을 이용하여 폐기포 절제를 시행한, 원발성 자연 기흉 환자 22명이었다. 수술전에 단순 흉부 X선 사진과 흉강조영술을 시행하여, 이를 수술시의 폐기포의 소견과 비교하였다. 결과: 흉강조영술의 Sensitivity는 75%로 단순 흉부 X선 사진의 30%에 비하여 높았고, 정확도(Accuracy)도 72.7%로 단순 흉부 X선 사진의 36.4%에 비하여 높았다. 그러나 Specificity는 흉강조영술이 50%로 단순 흉부 X선 사진의 100%에 비하여 낮았다. 검사로인한 합병증은 없었다. 결론: 결론적으로 기흉의 수술전 검사로서 흉강조영술은 단순 흉부 X선 사진에 비하여 높은 진단적 가치를 지녔으며, 안전하게 이용될 수 있으리라 생각된다.

  • PDF

의료영상에 적합한 무손실 압축 알고리즘 (The Lossless Compression Algorithm for Medical Images)

  • 오명신;한승조
    • 한국음향학회지
    • /
    • 제17권8호
    • /
    • pp.34-40
    • /
    • 1998
  • 본 논문에서는 일반 X-ray 필름을 사용하는 기존 아날로그 의료 영상 진단 체계의 문제점들을 해결하기 위해 연구 개발된 포괄적인 영상관리 전송 시스템(PACS)에서의 효율 적인 영상 전송과 저장을 위해 병원에서 매일 다량으로 발생하는 의료 영상들 중 CT와 MR영상을 대상으로 하여 새로운 무손실 영상 압축 기법인 CRAC 압축 알고리즘을 설계하 였다. CRAC 압축 알고리즘에서는 CT와 MR 영상의 파일구조를 분석하여 런랭스 코딩에 적합하도록 데이터를 재배열하는 전처리 작업을 설계하였으며, 이를 CT와 MR 영상에 최적 화 시킨 개선된 런랭스 알고리즘으로 1차 압축시켜 그 결과를 산술 부호화 알고리즘과 결합 함으로써 압축효율을 향상시켰다. 이러한 CRAC 압축 알고리즘은 무손실 압축 기법으로, 의 료 영상을 압축한 수 손실 없이 원 영상을 그대로 복원할 수 있기 때문에 PACS에서의 CT, MR 영상의 판독을 위한 단기 저장시에 적합한 압축 알고리즘으로 CT와 MR 영상의 무손 실 압축에 대해 새로운 전처리 방법을 제시하였고, 기존 무손실 압축 방법들과 비교 분석한 결과 압축률이 2.1%∼5.9% 정도 향상되었다.

  • PDF

데이터 획득장치에 이용되는 포토센서에 대한 DAS의 신호분석연구 (A Study on Signal Analysis of the Data Aquisition System for Photosensor)

  • 황인호;유선국
    • 재활복지공학회논문지
    • /
    • 제10권3호
    • /
    • pp.237-242
    • /
    • 2016
  • slip-ring 기술을 가진 spiral CT의 주요 장점으로는 X-ray 튜브의 연속적인 회전에 의해 환자에 대한 정보의 손실 없이 데이터를 연속적으로 획득할 수 있다는 것이다. 또한, X-선량의 인체 흡수의 감소를 위해서, 고시그널 저노이즈 및 빠른 데이터 획득 시간을 갖는 시스템이 요구되어 진다. 본 연구에서, CT 적용을 위해 다채널 포토센서 및 데이터 획득 시스템이 개발되어 졌다. 포토센서의 모듈은 16채널 CdWO4 크리스탈 및 실리콘 베이스의 포토다이오드가 사용되었다. 또한, 포토센서로 부터의 입력 신호에 대한 전기적인 증폭을 위해, 트랜스 임피던스 스위치 인테그레이터가 사용되었다. 스위치 인테그레이터는 CT 적용에 대해 적합한 시그널 밴드와 노이즈 퍼포먼스를 갖고 있다. 데이터 획득과 20 bit ADC 의 컨트롤은 FPGA를 이용하였고, 코딩은 VHDL을 사용하였다. CdWO4 기반의 실리콘 포토센서와 고SNR 및 좁은 시그널 밴드를 가진 증폭단 및 FPGA기반의 디지털 하드웨어는 CT적용 이외에 하드웨어 변경 없이 다른 분야에서도 이용 가능하다.

반복적인 복부 컴퓨터단층촬영 시행 시 환자선량 감소를 위한 관전압 변화 적용의 유용성 (Usefulness of Application of Tube Voltage Changes to Reduce Patient Dose during Abdominal CT Follow up)

  • 윤준;김현주
    • 한국방사선학회논문지
    • /
    • 제15권3호
    • /
    • pp.293-299
    • /
    • 2021
  • CT 장치를 이용하여 주기적인 검사를 시행하는 환자의 불가항력적 방사선 피폭을 줄이기 위해 다양한 스캔 파라미터 중 X선의 투과력과 밀접한 관전압의 변화를 통해 환자 선량을 감소시킬 수 있는 스캔 방법을 알아보았다. 실험결과 일반적으로 임상에서 많이 적용하는 120 kVp 대신 100 kVp를 적용하여 스캔 시 CTDI가 약 41 % 감소하였다. 또한 화질 변화정도는 CT value는 1046.1±3.7 HU, Pixel value는 71.4±7.9로 측정되었으며 통계분석결과 큰 차이가 없는 것으로 분석되었다(0.05

The ability of panoramic radiography in assessing maxillary sinus inflammatory diseases

  • Nah, Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • 제38권4호
    • /
    • pp.209-213
    • /
    • 2008
  • Purpose : To evaluate the relative diagnostic accuracy of panoramic radiography and Water's projection in maxillary sinus inflammatory diseases by comparing the radiodensities of the images with those of CT. Materials and Methods : Panoramic radiographs, Waters' projection, and CT images from 55 subjects (11O sinuses) were included in this retrospective study. The radiodensity of each maxillary sinus in panoramic radiography was recorded separately as upper and lower divided horizontally by hard palate. In Waters' projection, the overall sinus radiodensity was recorded. The CT images were considered as gold standard. Results : In panoramic radiography, 83 sinuses had same upper and lower radiodensity and 72 of these were consistent with those of CT, 26 sinuses had different upper and lower radiodensity and 15 of these, upper radiodensity was consistent with CT, the remaining 11, lower radiodensity was consistent with CT. One sinus had upper radiolucency with lower radiopacity and both were consistent with those of CT. Altogether 73 (66.4%) among 110 sinuses in panoramic radiography showed full agreement with CT, 26 (23.6%) showed partial agreement with CT. 9 sinuses had no lower image under the hard palate in panoramic radiography due to the smaller size of sinus. In Waters' projection, the radiodensity of 105 sinuses (95.5%) were consistent with that of CT. Conclusion : The panoramic radiography showed 90.0% of the sinus conditions fully or partially which may appear less accurate than that of Water's view (95.5%) but with more detailed information of the inferior part of sinuses. (Korean J Oral Maxillofac Radiol 2008; 38 : 209-13)

  • PDF

Cone beam CT와 일반 CT의 흡수선량 및 유효선량 비교평가 (Comparison of cone beam CT and conventional CT in absorbed and effective dose)

  • 김상연;한진우;박인우
    • Imaging Science in Dentistry
    • /
    • 제38권1호
    • /
    • pp.7-15
    • /
    • 2008
  • Purpose: This study provides comparative measurements of absorbed and effective doses for newly developed cone beam computed tomography (CT) in comparison with these doses for conventional CT. Materials and Methods: Thermoluminescent dosimeter rods (TLD rod: GR-200, Thermo Fisher Scientific Inc., Waltham, MA, USA) were placed at 25 sites throughout the layers of Male ART Head and Neck Phantom (Radiology Support Devices Inc., Long Beach, USA) for dosimetry. Implagraphy, DCT Pro (Vatech Co., Hwasung, Korea) units, SCT-6800TXL (Shimadzu Corp., Kyoto, Japan), and Crane x 3+(Soredex Orion Corp., Helsinki, Finland) were used for radiation exposures. Absorption doses were measured with Harshaw 3500TLD reader (Thermo Fisher Scientific Inc., Waltham, MA, USA). Radiation weighted doses and effective doses were measured and calculated by 2005 ICRP tissue weighting factors. Results: Absorbed doses in Rt. submandibular gland were 110.57 mGy for SCT 6800TXL (Implant), 24.56 mGy for SCT 6800TXL (3D), 22.39 mGy for Implagraphy 3, 7.19 mGy for DCT Pro, 5.96 mGy for Implagraphy 1, 0.70 mGy for Cranex 3+. Effective doses $(E_{2005draft)$ were 2.551 mSv for SCT 6800TXL (Implant), 1.272 mSv for SCT 6800TXL (3D), 0.598 mSv for Implagraphy 3, 0.428 mSv for DCT Pro and 0.146 mSv for Implagraphy 1. These are 108.6, 54.1, 25.5, 18.2 and 6.2 times greater than panoramic examination (Cranex 3+) doses (0.023mSv). Conclusion: Cone beam CT machines recently developed in Korea, showed lower effective doses than conventional CT. Cone beam CT provides a lower dose and cost alternative to conventional CT, promising to revolutionize the practice of oral and maxillofacial radiology.

  • PDF

이동형 전산화단층촬영장치의 기본 안전 및 필수 성능 기준을 마련하기 위한 연구 (A Study on Establishment of Basic Safety and Essential Performance Criteria of Mobile Computed Tomography)

  • 김은혜;박혜민;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.261-267
    • /
    • 2021
  • As the number of Coronavirus Disease-19 (COVID-19) patients increases in a global pandemic situation, the usefulness of mobile computed tomography (CT) is gaining attention. Currently, mobile CT follows the basic safety and essential performance evaluation criteria of whole-body or limited-view X-ray CT in order to obtain device approval and evaluation in the Republic of Korea. Unlike stationary CT, mobile CT is not operated in shielded areas but rather areas such as intensive care units, operating rooms, or isolation rooms. Therefore, it requires a different basic safety and essential performance evaluation standard than stationary CT. In this study, four derived basic safety evaluation criteria related to electrical, mechanical, and radiation safety were included (dose indication test, protection against stray radiation, safety measures against excessive X-rays, half-value layer measurement); and seven essential performance evaluation criteria were included (tube voltage accuracy, mAs accuracy, radiation dose reproducibility, CT number of water, noise, uniformity, and spatial resolution); total eleven basic safety and essential performance evaluation criteria were selected. This study aims to establish appropriate basic safety and essential performance evaluation criteria for simultaneously obtaining images with diagnostic value and reducing the exposure of nearby patients, medical staff, and radiologic technologists during the use of mobile CT.