• Title/Summary/Keyword: X-Ray CT

Search Result 949, Processing Time 0.033 seconds

Analysis of Correlation between Flexural Strength and Pore Characteristics on CFRP Rebar as Fabrication Method (탄소보강근의 제조 조건에 따른 휨강도와 기공 특성과의 상관성 분석)

  • Kim, Nam-Il;Kwon, Do-Young;Chu, Yong-Sik
    • Composites Research
    • /
    • v.35 no.5
    • /
    • pp.328-333
    • /
    • 2022
  • In this study, the fabrication conditions of CFRP rebar were controlled to derive the correlation between flexural strength and pore characteristics. The fabrication conditions of CFRP rebar were adjusted for presence or absence of rib, resin temperature, and curing furnace temperature. Flexural strength and pore characteristics of fabricated CFRP rebar were analyzed. The flexural strength of CFRP rebar was changed depending on the fabrication condition, such as the presence or absence of rib, the resin temperature, and the curing furnace temperature. It was confirmed that the flexural strength of CFRP rebar was significantly lowered when the rib was not wound. As a result of Nano X-ray CT analysis, the max. pore diameter was shown in CFRP rebar prepared at a resin temperature of 60℃. According to optical microscopic analysis, the maximum porosity was 6.89% in No. 1, and the minimum porosity was 2.88% in No. 7. The correlation coefficient between porosity used optical microscopy and flexural strength was -0.64, which was higher than the correlation coefficient between porosity or pore size used Nano X-ray CT and flexural strength.

Current Topics on Quality Assurance of X-ray Diagnosis in Japan

  • Katoh, Tuguhisa;Imamura, Keiko;Matumoto, Toru
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.13-16
    • /
    • 2002
  • Recent topics on quality assurance (QA) of X-ray diagnosis in Japan were reported in this presentation. These were related to mass screening mammography (MMG), lung screening CT (LSCT), skin injury caused by interventional radiology (IVR) and traceable system of dosimeters for x-ray diagnosis. In these successful stories, the author would like to stress the cooperation of all the medical am: clinical staff including medical doctors, radiological technologists, medical physicists, manufacturers of medical devices and others.

  • PDF

A Study on the Use of Active Protocol Using the Change of Pitch and Rotation Time in PET/CT (PET/CT에서 Pitch와 Rotation Time의 변화를 이용한 능동적인 프로토콜 사용에 대한 연구)

  • Jang, Eui Sun;Kwak, In Suk;Park, Sun Myung;Choi, Choon Ki;Lee, Hyuk;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.67-71
    • /
    • 2013
  • Purpose: The Change of CT exposure condition have a effect on image quality and patient exposure dose. In this study, we evaluated effect CT image quality and SUV when CT parameters (Pitch, Rotation time) were changed. Materials and Methods: Discovery Ste (GE, USA) was used as a PET/CT scanner. Using GE QA Phantom and AAPM CT Performance Phantom for evaluate Noise of CT image. Images are acquired by using 24 combinations that four stages pitch (0.562, 0.938, 1.375, 1.75:1) and six stages X-ray tube rotation time (0.5s-1.0s). PET images are acquired using 1994 NEMA PET Phantom ($^{18}F-FDG$ 5.3 kBq/mL, 2.5 min/frame). For noise test, noise are evaluated by standard deviation of each image's CT numbers. And then we used expectation noise according to change of DLP (Dose Length Product) to experimental noise ratio for index of effectiveness. For spatial resolution test, we confirmed that it is possible to identify to 1.0 mm size of the holes at the AAPM CT Performance Phantom. Finally we evaluated each 24 image's SUV. Results: Noise efficiency were 1.00, 1.03, 1.01, 0.96 and 1.00, 1.04, 1.02, 0.97 when pitch changes at the QA Phantom and AAPM Phantom. In case of X-ray tube rotation time changes, 0.99, 1.02, 1.00, 1.00, 0.99, 0.99 and 1.01, 1.01, 0.99, 1.01, 1.01, 1.01 at the QA Phantom and AAPM Phantom. We could identify 1.0 mm size of the holes all 24 images. Also, there were no significant change of SUV and all image's average SUV were 1.1. Conclusion: 1.75:1 pitch is the most effective value at the CT image evaluation according to pitch change and It doesn't affect to the spatial resolution and SUV. However, the change of rotation time doesn't affect anything. So, we recommend to use the effective pitch like 1.75:1 and adequate X-ray tube rotation time according to patient size.

  • PDF

Background Removing for Digital image self-adaptive acquisition in medical X-ray imaging

  • Li, Xun;Kim, Young-Ju;Song, Young-Jun
    • International Journal of Contents
    • /
    • v.4 no.1
    • /
    • pp.12-15
    • /
    • 2008
  • In this paper, we propose a new method of background removing for digital self-adaptive acquisition in medical X-ray imaging. We analysis the construction of video digital acquisition system and main factors of acquired image quality, propose a more efficiency method to against background non-uniformly. With proposed method, non-uniform illumination back ground was well removed without image quality degradation.

Analysis of Porosity and Distribution of Pores in Rocks by Micro Focus X-Ray CT (미소 초점 X선 CT를 이용한 암석 내 공극의 분포 및 공극률 분석)

  • Jeong, Gyo-Cheol;Takahashi, Manabu
    • The Journal of Engineering Geology
    • /
    • v.20 no.4
    • /
    • pp.461-465
    • /
    • 2010
  • Weathering and permeability in rocks play a very important role in underground disposal of radioactive waste and their long-term management as well as stability security of rock structures. Weathering and permeability of rocks are largely controlled by the characters of inner structures of rocks. In other words, weathering rate can be accelerated depending on the quantity of pore and microcrack in rocks. Quantitative evaluation of inner structures of rocks can serve as a tool that can assess the degree of weathering of rocks. Therefore it can be said that the understanding of three dimensional distribution of the inner structure of rocks is important for long-term management of rock structures. This study was performed to analyze three dimensional distribution of pore in rocks using Micro Focus X-ray CT on fresh granite and weathered granite from Korea. Results of the analysis clearly show distribution of pore and porosity of the inner rock.

Visualization of the Gastric Calcification due to Cancer on Tc-99m DPD and Abdominal CT Images (Tc-99m DPD 골스캔과 복부 CT 영상에서 보이는 위암의 석회화)

  • Jeong, Young-Jin;Kang, Do-Young
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.5
    • /
    • pp.344-346
    • /
    • 2004
  • A 69-year-old woman was presented with progressed dysphagia, gastric soreness and weight loss during 2 months. She was performed abdomen x-ray, EGDS and abdomen CT. Abdomen x-ray demonstrated punctuate calcification on LUQ. EGDS showed an ulceroinfiltrative mass with bleeding on cardia to antrum of stomach. And CT showed diffuse gastric wall thickness with multiple calcifications. Biopsy of the stomach and esophagus during EGDS examination revealed an adenocarcinoma, with signet ring cell type, infiltrating the wall of the stomach and the distal esophagus. Then acne scan was performed a few days later. It revealed intense uptake in LUQ, corresponding to the calcium containing neoplasm seen on the abdomen x-ray, EGDS and abdomen CT. And there was no evidence of any metastatic lesion and thyroid uptake on the bone scan. There are many reports about accumulation of the tracer in extraosseous lesion, but only a few literatures were reported about gastric calcification in stomach cancer. More over, no reports showed CT images. We are performed many diagnostic examinations and found well correlation between them. The reason of gastric calcification is considered with calcium deposition within extracellular space due to hemorrhage or necrosis. Other possibility offered to explain gastric calcification have been increased blood flow and/or increased neovascularity with capillary leaks of tracer, and specific enzymatic (phosphatases) receptor binding of tracer. So, it was happened ion exchange between intracellular calcium and phosphate groups of tracer.

PLUG-IN MODULES ON PLUTO FOR IDENTIFYING INFLAMMATORY NODULES FROM LUNG NODULES IN CHEST X-RAY CT IMAGES

  • Hirano, Yasushi;Seki, Nobuhiko;Eguchi, Kenji
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.794-798
    • /
    • 2009
  • We introduce an implementation of plug-ins on PLUTO. These plug-ins discriminate inflammatory nodules from other types of nodules in chest X-ray CT images. The PLUTO is a common platform for computer-aided diagnosis systems on Microsoft Windows series and it is easy to add new functions as plug-ins. We coded two plug-ins. One of the them calculates features based on medical knowledge. The other plug-in calculates parameters to classify the type of nodules, and it also classifies nodules into inflammatory nodules and others using SVM. These plug-ins are coded using MIST library which is produced at Nagoya University, Japan. In our previous study, the MIST library was parallelized, so that we can utilize a number of CPUs to calculate features and SVM learning/classifying depending on the amount of computation. Using these plug-ins, it became easy to extract features to discriminate inflammatory nodules from other types of nodules and to change parameters for feature extraction and SVM learning/classifying with GUI interface. The accuracy of the classifying result is 100% with 78 solid nodules which contains 43 inflammatory nodules and 35 other type of nodules.

  • PDF

Practical Approach to the Diagnosis of Pediatric Nasal Bone Fractures (소아 환자의 코뼈 골절 진단을 위한 실제적 접근)

  • Lee, Yulkok;Oh, Sungchan;Cho, Sukjin;Kim, Hyejin;Kang, Taekyung;Choi, Seungwoon;Yoo, Hanbin;Ryu, Seokyong
    • Journal of Trauma and Injury
    • /
    • v.27 no.4
    • /
    • pp.95-100
    • /
    • 2014
  • Purpose: Nasal bone fractures are the most common childhood facial bone fractures, with an incidence of about 39%. While taking a nasal bone x-ray is a common modality used in the emergency department, reports have expressed concerns with its low sensitivity and low specificity. Our study was aimed at comparing accuracy of physical and x-ray examination with that of facial bone computed tomography (CT). Methods: Electronic medical records (EMR) were retrospectively reviewed for patients under the age of 15 who visited our emergency department from January 2010 to December 2011with a chief complaint of nasal pain due to trauma and who had also undergone a nasal bone x-ray and facial bone CT. Patients who had not taken facial bone CT, who had been transferred, and who did not have EMR were excluded. We divided the patients into 2 groups, those who had nasal bone fractures and those without a fracture on their facial bone CT. We analyzed other parameters such as age, sex, and type of fracture to find statistical differences between the two groups. Results: A total of 209 patients were included. The patients with nasal bone fractures on their facial bone CT were older, and their traumas were more violent. Ten patients who had apparent nasal bone fractures on their facial bone CT had no definite signs of a fracture on their plain x-ray. Conclusion: Though facial bone CT is an effective modality in detecting nasal bone fractures, in evaluating younger patients suspected of having nasal bone fractures, prudent use of facial bone CT is needed to reduce unnecessary exposure to radiation.

Diagnosis of Location and Size of Lesions using Chest X-ray Image (X-선 영상을 이용한 암의 위치 및 크기 진단)

  • Jung-Min, Son;Byung-Ju, Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.167-173
    • /
    • 2023
  • X-ray general radiography is the simplest and most important one to get a lot of information. Nevertheless, current x-ray general radiography does not observation in-depth observation. Information about the anatomy of the human body and changes in disease in x-ray general radiography can be obtained but it is difficult to determine the size and shape of the actual lesion due to the disadvantage of expanding the image. In this study, PA and LAT images were acquired and cancer magnification was calculated in the images by measuring the distance of cancer samples. By adjusting the magnification the actual cancer length and thickness were measured and compared with the CT image and the actual cancer sample size. After the PA and LAT images of the inserted 6.0 mm cancer sample were obtained and the magnification was corrected, the length was 5.9 mm and the thickness was 6.1 mm. This value was measured similarly to the actual. The problem of obtaining the magnification that needs to know the actual length from the detector to the cancer sample was secured by obtaining the magnification through PA and LAT images and it is possible to accurately measure the cancer sample size. X-ray general radiography may provide useful information in situations where CT imaging is difficult.