• Title/Summary/Keyword: X-Ray 영상

Search Result 1,395, Processing Time 0.022 seconds

Analysis of Image Quality According to Imaging Parameters in Digital Tomosynthesis (디지털 단층영상합성장치의 영상획득 조건에 따른 화질 분석)

  • Lee, Dahye;Lee, Seungwan;Kim, Burnyoung;Yim, Dobin;Nam, Kibok;Cho, Jeonghyo
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.477-486
    • /
    • 2020
  • The purpose of this study was to evaluate the effects of reconstruction filters, X-ray source trajectories and intervals in the quality of digital tomosynthesis (DT) images, and the results was clinically validated. The filtered back-projection was implemented by using Ramp, Shepp-Logan, Cosine, Hamming, Hann and Blackman filters, and the X-ray source trajectories were simulated with 1 × 36, 2 × 18, 3 × 12, 4 × 9 and 6 × 6 arrays. The X-ray source intervals were 5, 10, 20, 30 and 40 mm. The depth resolution, spatial resolution and noise of DT image were evaluated by measuring artifact spread function (ASF), full width at half maximum (FWHM) and signal-to-noise ratio (SNR), respectively. The results showed that the spatial resolution and noise properties of DT images were maximized by the Ramp and Blackman filters, respectively, and the depth resolution and noise properties of the DT images obtained with a 1 × 36 X-ray source trajectory were superior to the other trajectories. The depth resolution and noise properties of DT images improved with an increase of X-ray source intervals, and the high X-ray source intervals degraded the spatial resolution of DT images. Therefore, the characteristics of DT images are highly dependent on reconstruction filters, X-ray source trajectories and intervals, and it is necessary to use optimal imaging parameters in accordance with diagnostic purpose.

Flow Measurement in Xylem Vessels of a Bamboo Leaf Using Synchrotron X-ray Micro Imaging (Synchrotron X-ray 미세영상기법을 이용한 식물 목질부 내부 수액 유동의 계측)

  • Kim Yang Min;Lee Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.83-86
    • /
    • 2003
  • Synchrotron X-ray micro imaging technique was employed to non-invasively monitor the water flow inside xylem vessels in a bamboo leaf. The phase contrast X-ray images clearly visualized plant anatomy and the rise of a water front inside the vessels. Consecutive X-ray images taken for 60 seconds revealed water rise kinetics against gravity in the xylem of a cut dry leaf taken from a bamboo tree. For the first time, traces of water rise, variation of contact angle between water and xylem wall as well as the internal structure of xylem were obtained. In xylem vessels, a repeating flow pattern has a typical flow velocity of $30.7{\mu}m/s$ and faster flow is established intermittently. It is concluded that the transmission type of X-ray micro imaging can be used as a powerful tool to investigate the ascent of sap in the xylem vessels at a resolution higher than that of MRI.

  • PDF

Feasibility study of insertable miniature x-ray source for dental imaging (치과 영상용 삽입형 초소형 X선 튜브의 가능성 연구)

  • Cho, Sung-Ho;Kim, So-Yeong;An, So-Hyun;Lim, Soo-Mee;Lee, Re-Na
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.39-45
    • /
    • 2012
  • Conventional periphery radiography system has a various problem such as patient dose and the pain of X-ray examination. In this paper, to solve these problems, we suggested insertional miniature x-ray system and we verified the feasibility of this system. First, we performed the Geant4 x-ray simulation to design x-ray collimator and filter to use miniature x-ray tube and we decided optimized thickness of filter and collimator. Also, we measured x-ray spectrum using CdTe detector and PX4 module to verify simulation results. Also, we acquired teeth image of fabricated phantom using conventional dental x-ray and prosed miniature x-ray system. As a results, our system has good image quality as compared to those of conventional systems. Our evaluation of the proposed system indicates that it can be potentially very useful for dental imaging.

The energy spectrum and phantom image quality according to mammography target-filter combinations (유방촬영장치의 타깃에 따른 에너지스펙트럼 및 팬텀영상화질)

  • Jang, Seyoung;Oh, Wanggyun;Park, Jongbae;Jin, Gyehwan
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.51-55
    • /
    • 2013
  • When the X-ray energy is high, the X-ray penetrates the object and decrease the contrast of imaging, and when the X-ray energy is low, the X-ray increases the contrast of imaging but it is to be absorbed into the object, which in the long run increases patient's radiation exposure level. Therefore, appropriate X-ray energy is an essential element affecting the imaging quality and radiation exposure level. This study simulated the energy spectrums according to the target materials of mammography, and compared qualities of phantom imaging for the management of radiolographic quality and patient's radiation exposure level with the introduction of the mammography that employs diversified radiation quality by using new anode materials.

Block-based Contrast Enhancement Algorithm for X-ray Image (X-ray 영상을 위한 블록 기반 대비 개선 알고리즘)

  • Choi, Kwang Yeon;Song, Byung Cheol
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2015.07a
    • /
    • pp.536-537
    • /
    • 2015
  • 지역적으로 영상의 대비를 개선하는 알고리즘은 X-ray 영상에서 효과적인 대비 개선의 결과를 얻을 수 있는 방법이다. 그러나 일반영상과는 다른 X-ray 영상의 특성으로 과도한 개선과 인접한 지역간의 특성이 비슷하지 않은 경우가 있기 때문에 부자연스러운 결과를 발생시킨다. 본 논문은 위와 같은 문제들을 해결하기 위해 비 중첩 서브블록 기반 영상 대비 개선 알고리즘으로 각 서브블록당 대비 개선 적용 방법과 블록화 현상 제거 방법을 제안한다. 제안 대비 개선 방법은 적절한 대비 개선과 빠른 연산 결과를 보이며, 블록화 제거 방법은 자연스러운 최종 결과를 얻는다.

  • PDF

The MTF Measurement of the Conventional X-ray System by using the Computed Radiography (CR을 이용한 일반촬영장치의 MTF 측정)

  • Kim, Chang-Bok
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.111-115
    • /
    • 2005
  • The quality of image from the system that creates medical images by using X-ray depends on the various different reasons such as the X-ray generator, the subject and the image transmission medium. In other words, thereare various factors existing that can influence on the quality of image from the moment when the X-ray is generated and until the final image is created. Therefore, the operator who creates images at the clinical site should make continuous evaluation and observation from the final image. There are various methods of evaluating the medical images, but it is assumed that the MTF measurement method can be suitable for measuring actual or effective resolution. So in this study, the MTF measurement method by using X-ray film has been avoided and the MTF features according to the deterioration of the X-ray system have been measured by using the software (the program used Borland C++ builder software and LEAD tools software) that can measure the MTF of the digital medical images. As the result of this measurement, it has been found out through the MTF graph that the resolution and sharpness from the old x-ray generator with a many years of using and many numbers of times of using were deteriorated for the quality of image comparing to those from the new system. Also a simple and easy measurement method for the MTF from the digital medical images can be obtained in this study.

  • PDF

Algorithm development of automatic symptom degree for Patient with Hallux Valgus (무지외반증 환자의 증상정도의 자동분류 알고리즘 개발)

  • Han, Hyun-Ji;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.2
    • /
    • pp.96-102
    • /
    • 2011
  • In this study, we performed algorithm development of automatic symptom degree for patient with hallux valgus one of the representative foot disease of morden. And this study proposes an efficient automated technique that is different from the original analog diagnosis for treatment and surgery of hallux valgus using digital image process. And we used X-Ray images of both a normal and a patient with hallux valgus in the procedure. First, we marked the standard angle on the X-Ray image of normal through Overlap & Add technique. Then we created a standard image through thinning filter and roberts filter(edge detection algorithm). Second, we used sobel filter of edge detection algorithm on the X-Ray image of patient. Moreover, we went another overlap & add technique procedure with both normal and patient image that we made. With the output, we projected the display detection image onto the screen. Finally, with the display detection image, we could measure and project the diagnosis angle of hallux valgus. And this confirms that this method is much more practical and applicable for another orthopedics disease than the prior one.

An Implementation of Radiologic Imaging Device of Remote Emergency Medical System (원격응급시스템의 방사선 영상장치 구현)

  • Cho, Dong-Heon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.60-65
    • /
    • 2007
  • The radiologic imaging device was implemented. It can be installed in an ambulance or used when an accident happens. After an equipment which generates X-ray generating unit with a tube in DC 12[V] had been made, a trait experiment using an oscilloscope was made. An experiment was carried out where the generated X-ray was saved as a form of a file using a digital detector. In this experiment, as a result of generating X-ray and detecting it using a digital detector, 1.67[MB]-, jpg- radical rays information could be saved. One distinct advantage of the developed radiologic imaging device is the fact that we can efficiently deal with emergency cases too far from the hospital, difficult to diagnose but treat simultaneously. By using the radiologic imaging device at the urgent scene of an accident or in a moving ambulance, we can provide the patient's X-ray information with the emergency medical specialist who is in the emergent medical center and have the patients prescribed and treated appropriately. As a result the developed emergency medical treatment can be expected.

Utilization-Focused Reduction of Radiation Exposure with XCP-DS FIT Sensor Holder by Measuring Dose of Dental X-ray Generator (구내 방사선발생기의 선량 분포측정을 통한 필름유지기구(XCP-DS FIT)의 피폭선량감소에 대한 유용성)

  • Lee, Kyung Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.465-471
    • /
    • 2012
  • In this study, three dimensional X-ray dose distribution from dental X-ray generator system was measured by ALOKA PDM-117 dosimeter. The X-ray dose distribution will be change with XCP-DS FIT in oral shot, because the distance between X-ray generator and the dosimeter. The X-ray dose change affects on patient exposure and radiograph image quality. Therefore, it is important to obtain relation between the X-ray dose and the distance. The X-ray dose at the central position was decreased with increasing the distance. Furthermore, the dose at the edge of the X-ray flux was increased with increasing the distance. The increased dose affects on the patient radiation exposure. The present results will provide for good dental radiograph image and reducing radiation over-exposure on patient.

Development of Acanthial Parieto Projection for Maxillary Diagnosis in X-ray Paranasal Sinuses (X-ray 코곁굴 검사에서 위턱굴 진단을 위한 비극-두정방향 촬영법 개발)

  • Byung-Ju Ahn;Yong-Wan Kim;In-Soo Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.327-333
    • /
    • 2023
  • In Order to Diagnose Maxillary Bone and Maxillary Sinus in the X-Ray Paranasal Sinus Projection test, this Study used Skull Rando Phantom to Change the Posture and X-ray tube Angle to 5° of the Head or 5° of ROC Who worked for more than 10 years. The Significance of the Evaluated score was Verified through SPSS Ver. 3.0, and the Cronbach value was Significantly higher at 0.712. In addition, as a Result of Calculating SNR by Setting the ROI(Receiver Operation Characteristic) of the Maxillary bone and Maxillary sinus images, it was the Highest at 6,449 in the Examination by tilting 5° toward the Head or Leg of the X-ray tube. In the study, it is believed that among the X-Ray simple Paranasal Sinus projection tests, a sharp Image can be Obtained during the Examination by Tilting the X-ray tube 5° toward the Head or Leg.