• Title/Summary/Keyword: X-Ray 영상

Search Result 1,391, Processing Time 0.027 seconds

An Effective Extraction Algorithm of Pulmonary Regions Using Intensity-level Maps in Chest X-ray Images (흉부 X-ray 영상에서의 명암 레벨지도를 이용한 효과적인 폐 영역 추출 알고리즘)

  • Jang, Geun-Ho;Park, Ho-Hyun;Lee, Seok-Lyong;Kim, Deok-Hwan;Lim, Myung-Kwan
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.7
    • /
    • pp.1062-1075
    • /
    • 2010
  • In the medical image application the difference of intensity is widely used for the image segmentation and feature extraction, and a well known method is the threshold technique that determines a threshold value and generates a binary image based on the threshold. A frequently-used threshold technique is the Otsu algorithm that provides efficient processing and effective selection criterion for choosing the threshold value. However, we cannot get good segmentation results by applying the Otsu algorithm to chest X-ray images. It is because there are various organic structures around lung regions such as ribs and blood vessels, causing unclear distribution of intensity levels. To overcome the ambiguity, we propose in this paper an effective algorithm to extract pulmonary regions that utilizes the Otsu algorithm after removing the background of an X-ray image, constructs intensity-level maps, and uses them for segmenting the X-ray image. To verify the effectiveness of our method, we compared it with the existing 1-dimensional and 2-dimensional Otsu algorithms, and also the results by expert's naked eyes. The experimental result showed that our method achieved the more accurate extraction of pulmonary regions compared to the Otsu methods and showed the similar result as the naked eye's one.

image processing and development of digital X-ray using CCD Camera (CCD 카메라를 이용한 디지털 X-ray개발과 영상처리에 관한 연구)

  • Jeong, Jae-Sang;Gang, Yong-Cheol;HwangBo, Soung
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2795-2797
    • /
    • 2003
  • 기존의 X-ray System을 보면 방사선 소스와 방사선을 가시광선으로 변환시키는 형광판, 그리고 이 발광된 빛을 증폭시키는 작용을 하는 영상 증배관과 필름으로 구성된다. 이에 따른 시스템의 부피와 한 장의 필름이 나오기까지의 과정 등이 매우 번거롭다. 이 시스템을 저비용의 디지털 X-ray 시스템으로 대체함에 있어서 형광판과 디지털 CCD카메라를 이용하여 저가이면서 시스템 자체는 간소화시킨 X-ray시스템을 개발하고자한다. X-ray이미지는 형광판의 밀도와 카메라의 분해능에 따라 그 해상도가 결정이 되지만, 이번연구에서는 8bit의 분해능에 $1300{\times}1030$의 해상도를 갖는 Monochrome Digital 카메라를 사용하고, 기존 시스템에 사용되던 간접촬영용 형광판을 사용하였다. 기존시스템의 영상증배관을 배제시켜 후처리에 중점을 두어 시스템은 간소화하고, 저비용을 실현시켰다.

  • PDF

Body and Region of Interest Segmentation Algorithm for Chest X-ray Image (흉부 X-ray 영상에서 몸체 및 관심영역 분할 알고리즘)

  • Park, Jin Woo;Song, Byung Cheol
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2015.07a
    • /
    • pp.133-134
    • /
    • 2015
  • 흉부 X-ray 영상에서 몸체 및 관심영역 분할 기법은 의료 X-ray 영상의 화질 개선 알고리즘을 더 효과적으로 적용하기 위해 전처리 단계로 영상의 물체와 배경을 분할하거나 관심영역만을 분할하는 방법이다. 보통 화질 개선 알고리즘을 적용할 때 영상의 밝기 정보나 주파수 정보를 이용하여 영상 디테일과 대비를 개선하는 방법을 사용한다. 영상 전체에 이러한 알고리즘을 적용하는 경우 불필요한 배경 정보가 포함되기 때문에 디테일과 대비가 떨어질 수 있다. 본 논문은 사용자가 보고자 하는 부분의 정보만을 사용하도록 물체를 분할하는 알고리즘을 제안한다. 1 단계로 몸체 분할 알고리즘을 이용하여 배경 성분의 정보를 제외하고 2 단계에서는 몸체의 중심인 폐와 폐사이의 장기 정보만을 볼 때의 관심영역 분할 알고리즘으로 팔이나 목, 복부의 불필요한 정보를 제외하는 방법을 제안한다.

  • PDF

A Study on the Parallel Processing Architecture for the Real Time Image Reconstruction of X-ray CT (X-ray CT의 실시간 영상재구성을 위한 병렬처리 구조에 관한 연구)

  • Jin, Seung-Oh;Heo, Chang-Won;Huh, Young
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3153-3155
    • /
    • 1999
  • 최근 수년간 의료영상분야는 국내외적으로 급격한 발전을 거듭하고 있다. 특히 자기공명영상장치 (Magnetic Resonance Imaging), X-ray CT(Computed Tomography)와 단층촬영장치는 인체내부를 비침습적(non-invasive)으로 영상화함으로써 해부학적인 질병진단에 많은 장점을 가지고 있다. 이와같은 단층영상 재구성에는 역매트릭스법(matrix inversion). 반복재구성법(interative method), 역투영 법(back-projection), 2차원 Fourier 변환법(2D FFT), 중첩재구성법(Filtered back-projection) 등의 다양한 알고리즘을 사용하고 있다. 본 연구에서는 X-ray CT에서의 단층영상재구성 기법 중 널리 사용되고 있는 Filtered Back Projection 기법의 연산순서도와 연산량을 분석하고 이를 시뮬레이션을 통하여 확인하고 실시간 영상재구성을 위하여 범용 Digital Signal Processor의 병렬처리시스템 구성에 기반된 최적 Architecture를 선정하고자 한다.

  • PDF

Measurement of Spinal Curvature by Using Enhanced Hough Transform on X-ray Imaging (X-ray 영상에서 개선된 허프 변환을 이용한 척추만곡도 측정)

  • Jeong, Hyang su;Kim, Kwang Beak
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.360-362
    • /
    • 2018
  • 본 논문에서는 X-ray 영상에서 척추 영역을 추출 및 분석하여 척추만곡도를 자동으로 측정하는 방법을 제안한다. 제안된 방법은 X-ray 영상에서 어깨뼈와 골반뼈 등과 같이 필요 없는 영역을 제거한 ROI(Region of Interest) 영역을 추출하고, 추출된 ROI 영역에서 척추 에지를 검출하기 위해 가우시안-라플라시안(Laplacian of Gaussian) 필터를 적용하여 척추 에지를 검출한다. 추출된 척추 영역을 척추의 Apex를 기준으로 Above Apex와 Below Apex 영역으로 구분하고 허프 변환(Hough Transform) 기법을 적용하여 두 영역에 대한 ($r,{\theta}$) 허프 공간을 구한다. ($r,{\theta}$) 허프 공간에서 척추만곡도 측정에 필요한 수평 직선만을 검출하기 위하여 수직 직선을 나타내는 교점들의 영역을 제거하여 척추만곡도 측정에 필요한 영역을 추출한다. 제안된 척추 추출 방법을 다양한 X-ray 영상을 대상으로 실험한 결과, 전문의가 척추만곡도를 효과적으로 측정하고 분석할 수 있는 척추 영역이 추출된 것을 확인할 수 있었다.

  • PDF

X-ray Image Histogram Equalization based on Understanding of Background Information (배경 정보 파악을 통한 X-ray 영상 히스토그램 평활화)

  • Kang, Young-Min;Lee, Kyung-Jun;Jeong, Je-Chang
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2014.11a
    • /
    • pp.283-286
    • /
    • 2014
  • X-ray 영상의 경우 검은 배경으로 인해 기존의 히스토그램 평활화를 사용하여 대비비를 향상 시킬 경우 문제가 발생한다. 전역 히스토그램 평활화의 경우 영상의 특징을 고려하지 않은 채 전체적으로 히스토그램 평활화가 이루어지기 때문에 부분적인 명암값을 개선시키기 어렵다. BBHE(Bright Preserving Bi-Histogram Equalization)과 DSIHE(Dualistic Sub-Image Histogram Equalization)과 같은 영역별 히스토그램 평활화의 경우 X-ray 사진특성상 검은 배경으로 인하여 히스토그램 평활화를 적용해도 원하는 대비비를 얻기 힘들며 부분적으로 왜곡이 발생한다. 이러한 문제를 해결하기 위해 본 논문에서는 영상의 히스토그램을 통해 배경 정보를 파악하여 밝기 영역을 나눈 후 히스토그램 평활화를 진행함으로써 X-ray 사진의 대비비를 효율적으로 향상시킨다.

  • PDF

Synchrotron Radiation Imaging of Tissues Using Phase Contrast Technique (방사광 위상차 현미경을 이용한 생체조직의 미세구조 영상)

  • Kang, Bo-Sun;Lee, Dong-Yeol;Kim, Ki-Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.2
    • /
    • pp.23-30
    • /
    • 2008
  • X-ray microscopy with synchrotron radiation(SR) might be a useful tool for novel x-ray imaging in the clinical and laboratory settings. Microscopically, it enables us to observe detailed structure of animal organs samples with a great magnification power and an excellent resolution. The phase contrast mechanisms in image by X-ray are described. The phase-contrast X-ray imaging with SR from in-vivo and in-vitro mouse tail, rat nerve and rat lung were obtained with an 8 KeV monochromatic beam. The visual image was magnified using 10x microscope objective lens and captured using an digital CCD camera. The results showed more structural details and high resolution images with SR imaging system than conventional X-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications and clinical radiography.

  • PDF

The Measurement and Analysis by Free Space Scatter Dose Distribution of Diagnostic Radiology Mobile Examination Area (영상의학과 이동검사 영역의 공간선량 분포에 대한 측정 및 분석)

  • Kim, Sung-Kyu;Son, Sang-Hyuk
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.5-13
    • /
    • 2009
  • There are several reasons to take X-ray in case of inpatients. Some of them who cannot ambulate or have any risk if move are taken portable X-ray at their wards. Usually, in this case, many other people-patients unneeded X-ray test, family, hospital workers etc-are indirectly exposed to X-ray by scatter ray. For that reason I try to be aware of free space scatter dose accurately and make the point at issue of portable X-ray better in this study. kVp dose meter is used for efficiency management of portable X-ray equipment. Mobile X-ray equipment, ionization chamber, electrometer, solid water phantom are used for measuring of free space scatter dose. First of all the same surroundings condition is made as taken real portable X-ray, inquired amount of X-ray both chest AP and abdomen AP most frequently examined and measured scatter ray distribution of two tests individually changing distance. In the result of measuring horizontal distribution with condition of chest AP it is found that the mAs is decreased as law of distance reverse square but no showed mAs change according to direction. Vertical distribution showed the mAs slightly higher than horizontal distribution but it isnt found out statistical characteristic. In abdomen AP, compare with chest AP, free space scatter dose is as higher as five-hundred times and horizontal, vertical distribution are quite similar to chest AP in result. In portable X-ray test, in order to reduce the secondary exposure by free space scatter dose first, cut down unnecessary portable order the second, set up the specific area at individual ward for the test the third, when moving to a ward for the X-ray test prepare a portable shielding screen. The last, expose about 2m apart from patients if unable to do above three ways.

  • PDF

How to Improve Image Quality for the Chest PA and the Simple Abdomen X-ray Examinations (흉, 복부 단순 X-ray 검사 시 영상의 질 향상 방법)

  • Cho, Pyong Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.165-173
    • /
    • 2013
  • The purpose of this study is to examine how much the movement at X-ray examinations like breathing or the positioning affects the image during chest or abdomen X-ray examination so as to create an image containing information as much as possible. The study method adopted is doing the X-ray in each of the states including breathing (inspiration & expiration) and movement in the standing chest PA X-ray and simple abdomen X-ray among the kinds of examination selected the most in hospitals and then evaluating them by applying the standards of image evaluation for each region. According to the study result, about the standing chest PA X-ray, the images taken at inspiration contain more information than those taken at expiration or having subtle movement during the examination. About the simple abdomen X-ray, the images taken at expiration contain more information than those taken at inspiration or movement. The above study results imply that regarding general X-ray examination, information we can find from the images may differ significantly according to the region examined, examination purpose, or movement during the examination like breathing.

Quality Control of Diagnostic X-ray Equipment in Medical Field (의료분야 진단용방사선발생장치의 품질관리)

  • Cho, Pyong-Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.159-164
    • /
    • 2021
  • The examination using diagnostic x-ray equipment is one of the most useful diagnostic equipment for identifying information in the human body in diagnostic radiology. For this reason, the number of examinations has recently increased a lot. Increasing the number of examinations will accelerate the aging of the device. In addition, this makes them aware of the importance of quality control for the diagnostic x-ray device. Particularly, in a diagnostic x-ray device, quality control refers to an act of always maintaining a certain level of image quality by identifying and correcting all problems that may lead to reduction of the diagnosis area in advance. Therefore, this study summarizes and reports general information about quality control in examinations using diagnostic x-ray equipment.