• 제목/요약/키워드: X-RAY SCATTERING

검색결과 449건 처리시간 0.028초

MONTE CARLO SIMULATION OF COMPTONIZATION IN A SPHERICAL SHELL GEOMETRY

  • SEON KWANG IL;MIN KYOUNG WOOK;CHOI CHUL SUNG;NAM UK WON
    • 천문학회지
    • /
    • 제27권1호
    • /
    • pp.45-53
    • /
    • 1994
  • We present the calculation of X -ray spectra produced through Compton scattering of soft X-rays by hot electrons in the spherical shell geometry, using fully relativistic Monte Carlo simulation. With this model, we show that the power-law component, which has been observed in the low luminosity state of low-mass X-ray binaries (LMXBs), is explained physically. From a spectral. analysis, we find that spectral hardness is mainly due to the relative contribution of scattered component. In addition, we see that Wi en spectral features appear when the plasma is optically thick, especially in the high energy range, $E{\gtrsim}100keV$. We suggest that after a number of scattering the escape probability approaches an asymptotic form depending on the geometry of the scattering medium rather than on the initial photon spectrum.

  • PDF

A New Approach on the Correction for Compton Escape Component in X-Ray Unfolding Algorithm

  • Kim, Soon-Young;Kim, Jong-Kyung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(2)
    • /
    • pp.925-930
    • /
    • 1995
  • A new approach on the correction for Compton escape component in X-ray unfolding algorithm was investigated to obtain more accurate X-ray source spectrum. The X-ray detector used in this study was a planar type HPGe detector(EG&G ORTEC, GLP-32340/13-P-LP) whose energy response has been blown and ISO narrow beam series were employed as source spectrum. At lower energy Part of measured X-ray spectrum including the correction for Compton escape component more accurate unfolded spectrum was obtained by letting down the starting energy level of the collection in existing spectrum correction procedure to consider multiple scattering effects. It is, from this study, concluded that accurate correction for Compton escape component is needed in X-ray unfolding procedure since Compton scattering becomes more important as incident X-ray energies increase.

  • PDF

X선촬영시(X線撮影時) 피사체(被寫體) 두께에 따른 격자비(格子比) 선정(選定)에 관한 연구(硏究) (Studios in Selected Grid Ratio of Objective Thickness on X-ray Exposure)

  • 윤철호;추성실;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제5권1호
    • /
    • pp.21-34
    • /
    • 1982
  • When unattenuated x-ray radiation passes through the object it is transmitted and scattered from objectes and impinging on the film. During this process certain radiation is absorbed within the object and others transmitted in reduced scattering. The scattering radiation influence upon radiation image quality, confining x-ray beam which means scattering radiation produce increased fog on x-ray film image and as a consequence decrease contrast and less detail of the film there for the elimination of fog and for absorbing scattered radiation, the grid has been used between the object and the film in order to rid of scattering rays. Using grid is good method for the qualification of the better image as well as in using air gap technique. The grid is easy to manipulate and promote good efficiency which is defined by ICRU and JIS. It is the purpose to study for eliminating scattered radiation from the tissue equivalent acryl phantom using grid, we have studied and evaluated the grid permeability about the x-ray exposure, the selection of grid ratio according to phantom thickness, on x-ray exposure are performed as follows. 1. The penetrating ratio of primary x-ray is remarkably decreased by increasing of the grid ratio, but it is almost not influenced in KVP difference and phantom thickness. 2. The scattered radiation is proportionaly increased by thickness of the phantom, having nothing to do with grid ratios. 3. The relative between the penetration rate of primary and secondary x-ray is improved by increasing grid ratio, and decreased by phantom thickness, and slightly decreased by high tube voltage. 4. The grid of 5:1 and 10:1 ratio are adequate to the phantom of 10cm and 15cm thickness, respectively.

  • PDF

X선촬영시(線撮影時) 연부조직(軟部組織) 두께에 따른 선량분포(線量分布)에 관(關)한 연구(硏究) (A Study on the Distribution of X-ray according to the Thickness of Soft Tissue in Radiography)

  • 박성옥
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제11권2호
    • /
    • pp.3-15
    • /
    • 1988
  • When X-rays were projected into a patient, there occured the phenomena such as penetration, absorption and scattering etc. The penetrating rays were recorded on films as X-ray image used for diagnosis but scattered rays caused the radiation hazard both to the patient, specialist and technicians. The soft tissue includes many organs which are sensitive to the radiation and in may occupy $40{\sim}50%$ of body weight. Therefore X-rays should be carefully projected to the patient and it is strongly recommended to analyse the distribution of X-rays, when ever the patient is exposed to X-rays. In this study, the distribution of X-ray according to the thickness, the radiation field and the tube voltages (kVp) in soft tissue, the following results were obtained: 1. Total transmitted rays which kept the step with X-ray tube voltage (kVp) increased in proportion to the increasing of X-ray tube voltage. 2. The scattered ray rate in the total transmitted ray was not significantly found with X-ray tube voltage. 3. The affecting factors of the scattered ray rate in total transmitted ray were shown through the radiation field and the thickness. 4. The dose of scattered ray by the angle was observed more in direction of primary ray ($0^{\circ}$) and back scattering ($160^{\circ}$) than in direction of $90^{\circ}$. 5. The more the distance from phantom to the patient should be less distribution of scattered ray.

  • PDF

X선 촬영실 내 공간선량의 분포와 거리 역자승 법칙과의 관련성 (Relationship between the Distribution of Space doses in X-ray Rooms and the "Inverse Square Law of Distance")

  • 최성관
    • 한국콘텐츠학회논문지
    • /
    • 제13권8호
    • /
    • pp.301-307
    • /
    • 2013
  • 본 연구는 손, 머리, 복부 등의 X선 촬영 시에 발생되는 공간선량이 어느 정도인지를 알아보고, 산란선에 의한 공간선량의 강도가 "거리 역자승 법칙"에 의해 감쇠하는지를 파악했다. 첫째, 손처럼 X선 산란선 발생량이 적은 촬영의 공간선량은 대부분 "거리 역자승 법칙"에 근접한 감쇠가 이루어지면서, 2m 거리에서는 전혀 측정되지 않았다. 둘째, 머리나 복부처럼 X선 산란선 발생량이 많은 촬영의 공간선량은 조사야 중심을 기준으로 30cm에서 1m 거리까지는 "거리 역자승 법칙"보다 더 높은 비율의 감쇠가 이루어지고, 1m에서 2m 거리까지는 "거리 역자승 법칙"에 의한 감쇠가 이루어졌다. 따라서 X선 촬영실 내에서는 손 촬영의 경우 조사야 중심으로부터 적어도 2m 이상 떨어져 있어야 하고, 머리나 복부 촬영의 경우 촬영실 내 모든 공간에서 보호용구를 이용한 X선 피폭 방어조치가 요구된다.

엑스선 공명 자기 산란을 이용한 자성 다층박막 및 나노 구조체의 자기 구조와 자기 스위칭 메커니즘의 연구 (X-Ray Resonant Magnetic Scattering Study of Magnetic Structures and Magnetic Switching Mechanism in Magnetic Multilayers and Nanostructures)

  • 이동렬
    • 한국자기학회지
    • /
    • 제20권4호
    • /
    • pp.160-166
    • /
    • 2010
  • 엑스선 공명 자기산란은 엑스선 반사율과 회절의 원리를 이용하여 자기 다층박막 내 깊이 방향의 자화 모양 및 자기 나노 구조체 내의 자화 분포를 특정 원소별로 구할 수 있다. 여기서는 엑스선 공명 자기산란에 대한 간단한 설명과 이를 이용한 자성 다층박막 및 나노 구조체의 자기 구조와 자기 스위칭의 연구에 대하여 몇 가지 예를 들어 설명하려 한다.

Small-Angle X-ray Scattering Station 4C2 BL of Pohang Accelerator Laboratory for Advance in Korean Polymer Science

  • Yoon, Jin-Hwan;Kim, Kwang-Woo;Kim, Je-Han;Heo, Kyu-Young;Jin, Kyeong-Sik;Jin, Sang-Woo;Shin, Tae-Joo;Lee, Byeong-Du;Rho, Ye-Cheol;Ahn, Byung-Cheol;Ree, Moon-Hor
    • Macromolecular Research
    • /
    • 제16권7호
    • /
    • pp.575-585
    • /
    • 2008
  • There are two beamlines (BLs), 4C1 and 4C2, at the Pohang Accelerator Laboratory that are dedicated to small angle X-ray scattering (SAXS). The 4C1 BL was constructed in early 2000 and is open to public users, including both domestic and foreign researchers. In 2003, construction of the second SAXS BL, 4C2, was complete and commissioning and user support were started. The 4C2 BL uses the same bending magnet as its light source as the 4C1 BL. The 4C1 BL uses a synthetic double multilayer monochromator, whereas the 4C2 BL uses a Si(111) double crystal monochromator for both small angle and wide angle X-ray scattering. In the 4C2 BL, the collimating mirror is positioned behind the monochromator in order to enhance the beam flux and energy resolution. A toroidal focusing mirror is positioned in front of the monochromator to increase the beam flux and eliminate higher harmonics. The 4C2 BL also contains a digital cooled charge coupled detector, which has a wide dynamic range and good sensitivity to weak scattering, thereby making it suitable for a range of SAXS and wide angle X-ray scattering experiments. The general performance of the 4C2 BL was initially tested using standard samples and further confirmed by the experience of users during three years of operation. In addition, several grazing incidence X-ray scattering measurements were carried out at the 4C2 BL.

실리콘 웨이퍼 표면에서 X-선 산만산란에 의한 기계적 손상층의 상대 정량 평가 (Relative quantitative evaluation of mechanical damage layer by X-ray diffuse scattering in silicon wafer surface)

  • 최치영;조상희
    • 한국결정성장학회지
    • /
    • 제8권4호
    • /
    • pp.581-586
    • /
    • 1998
  • 초크랄스키 실리콘 기판의 뒷면에 형성된 기계적 손상이 미치는 효과에 대하여 고찰하였다. 기계적 손상의 정도는 레이저 여기/극초단파 반사 광전도 감쇠법에 의한 소수반송자 재결합 수명, X-선 단면 측정 및 습식 산화/선택적 식긱 방법으로 평가하였다. 그 결과, 웨이퍼 뒷면에 가해지는 기계적 손상의 세기가 강할수록 소수반송자 재결합 수명은 짧아지고, 산만 산란 정도와 X-선 과잉 강도의 적분값은 비례적으로 증가하였으며, 그 값을 Grade 1의 손상된 웨이퍼에서의 과잉 강도로 정규화하면 과잉 강도의 상대 정량비는 Geade 1:Grade 2:Grade 3 = 1:7:18.4이다.

  • PDF

X선 산란분석법을 이용한 액정에멀젼 구조분석 (Structure Analysis of Liquid Crystal Emulsions Using X-ray Scattering Analysis)

  • 박소현;김수지;노민주;이준배;박수남
    • 대한화장품학회지
    • /
    • 제42권3호
    • /
    • pp.297-302
    • /
    • 2016
  • 본 연구에서는 $C_{12-20}$ 알킬글루코사이드, $C_{14-22}$ 알코올 및 베헤닐알코올로 구성된 액정에멀젼을 제조하고 다양한 분석장비를 이용하여 구조분석을 실시하였다. 먼저 제조한 액정에멀젼을 편광현미경과 cryo-SEM을 이용하여 각각 액정에멀젼의 특징인 maltese cross 무늬와 다층 구조를 확인하였다. 또한, DSC를 이용하여 액정상 형성을 확인하였고, small angle x-ray scattering (SAXS) 분석을 통하여 약 $305{\AA}$의 층간 간격을 갖는 다층 라멜라 구조를 확인하였다. 한편, wide angle x-ray scattering (WAXS) 분석을 통해 제조된 액정에멀젼의 라멜라 구조를 이루고 있는 알킬 사슬 간 배열이 사방정계 구조로 되어 있음을 확인할 수 있었다. 액정에멀젼 구조 연구를 통해 얻어진 다양한 물성 정보는 향후 산업적으로 많이 이용될 것으로 기대된다.