• Title/Summary/Keyword: X rays

Search Result 782, Processing Time 0.032 seconds

Real-time X-ray Scattering as a Nanostructure Probe for Organic Photovoltaic Thin Films

  • Lee, Hyeon-Hwi;Kim, Hyo-Jeong;Kim, Jang-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.181-181
    • /
    • 2013
  • Recently, nanostructure and the molecular orientation of organic thin films have been largely paid attention due to its importance in organic electronics such as organic thin film transistors (OTFTs), organic light emitting diodes (OLEDs), and organic photovoltaics (OPVs). Among various methods, the diffraction and scattering techniques based on synchrotron x-rays have shown powerful results in organic thin film systems. In this work, we introduce the in-situ annealing system installed at PLS-II (Pohang Light Source II) for organic thin films by simultaneously conducting various x-ray scattering measurements of x-ray reflectivity, conventional x-ray scattering, grazing incidence wide angle x-ray scattering (GI-WAXS) and so on. Using the in-situ measurement, we could obtain real time variation of nanostructure as well as molecular orientation during thermal annealing in metal-phthalocyanine thin films. The variation of surface and interface also could be simultaneously investigated by the x-ray reflectivity measurement.

  • PDF

Experimental study for the irradiation effect of x-ray on the hatching process of fertilized eggs (X선 조사가 닭 유정란 부화과정에 미치는 영향)

  • Jeon, Byeong-Kyou;Yeo, Jin-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6413-6419
    • /
    • 2013
  • This study examined the irradiation effect of high energy x-rays on the hatching process of fertilized eggs, particularly with regard to malformation and blood cells change. The experimental groups were five day old fertilized eggs irradiated with x rays at doses of 5, 7.5, 10 Gyusing alinear accelerator. The control group was not irradiated. After three weeks, hatched chicks were sacrificed and examined for blood sampling. The survival rate of the x-ray irradiated groups were significantly lower than that of the control group (46.7vs 80%). The malformation rate of the experimental groups was60%, whereas no congenital malformations were observed in the control group. The experimental groups had a significantly higher malformation rate. The types of malformation were left wing defect, proptosis, microcephaly, cervical spine, and feet anomaly. The incidence of malformation increased with increasing radiation dose. The white blood cell count of control group and eachexperimental groups (5 and 7.5 Gy) were 87.64, 100.76 and 81.42 ($10^3/{\mu}L$), respectively. X-ray irradiation of 5 day old chick embryos increased the rate of death and malformation significantly.The malformations were estimated to have occurred by chromosomal abnormalities. Further genetic studies will be needed to confirm the correlation between high energy X-rays and the cause of malformations.

Development of Multi-channel Detector of X-ray Backscatter Imaging (후방산란 엑스선 영상획득을 위한 다채널 검출기 개발)

  • Lee, Jeonghee;Park, Jongwon;Choi, Yungchul;Lim, Chang Hwy;Lee, Sangheon;Park, Jaeheung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.245-247
    • /
    • 2022
  • Backscattered x-ray imaging is a technology capable of acquiring an image inside an irradiated object by measuring X-rays scattered from an object. For image acquisition, the system must include an X-ray generator and a detection system for measuring scattered x-rays. The imaging device must acquire a real-time signal at sampling intervals for x-rays generated by passing through a high-speed rotating collimator, and for this purpose, a high-speed signal acquisition device is required. We developed a high-speed multi-channel signal acquisition device for converting and transmitting signals generated by the sensor unit composed of a large-area plastic scintillator and a photomultiplier tube. The developed detector is a system capable of acquiring signals at intervals of at least 15u seconds and converting and transmitting signals of up to 6 channels. And a system includes remote control functions such as high voltage, signal gain, and low level discrimination for individual calibration of each sensor. Currently, we are conducting an application test for image acquisition under various conditions.

  • PDF

Comparison of Quality of Bologna Sausage Manufactured by Electron Beam or X-Ray Irradiated Ground Pork

  • Shin, Mee-Hye;Lee, Ju-Woon;Yoon, Young-Min;Kim, Jong Heon;Moon, Byeong-Geum;Kim, Jae-Hun;Song, Beom-Suk
    • Food Science of Animal Resources
    • /
    • v.34 no.4
    • /
    • pp.464-471
    • /
    • 2014
  • Ground lean pork was irradiated by an electron beam or X-rays to compare the effects of two types of radiation generated by a linear accelerator on the quality of Bologna sausage as a model meat product. Raw ground lean pork was vacuum packaged at a thickness of 1.5 cm and irradiated at doses of 2, 4, 6, 8, or 10 kGy by an electron beam (2.5 MeV) or X-rays (5 MeV). Solubility of myofibrillar proteins, bacterial counts, and thiobarbituric acid reactive substance (TBARS) values were determined for raw meat samples. Bologna sausage was manufactured using the irradiated lean pork, and total bacterial counts, TBARS values, and quality properties (color differences, cooking yield, texture, and palatability) were determined. Irradiation increased the solubility of myofibrillar proteins in a dose-dependent manner (p<0.05). Bacterial contamination of the raw meat was reduced as the absorbed dose increased, and the reduction was the same for both radiation types. Differences were observed only between irradiated and non-irradiated samples (p<0.05). X-ray irradiation may serve as an alternative to gamma irradiation and electron beam irradiation.

Thickness-dependent magnetic domain structures of Co ultra-thin film investigated by scanning transmission X-ray microscopy

  • Yoon, Ji-Soo;Kim, Namdong;Moon, Kyoung-Woong;Lee, Joo In;Kim, Jae-Sung;Shin, Hyun-Joon;Kim, Wondong
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1185-1189
    • /
    • 2018
  • Thickness-dependent magnetic domain structure of ultrathin Co wedge films (0.3 nm-1.0 nm) sandwiched by Pt layers was investigated by scanning transmission x-ray microscopy (STXM) employing X-ray magnetic circular dichroism (XMCD), utilizing elliptically polarized soft x-rays and electromagnetic fields, with a spatial resolution of 50 nm. The magnetic domain images measured at the Co $L_3$ edge showed the evolution of the magnetic domain structures from maze-like form to the bubble-like form as the perpendicular magnetic field was applied. The asymmetric domain expansion of a 500 nm-scale bubble domain was also measured when the in-plane and perpendicular external magnetic field were applied simultaneously.

X-RAYING LARGE-SCALE STRUCTURE

  • HENRY J. PATRICK
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.5
    • /
    • pp.371-374
    • /
    • 2004
  • We review the observational evidence for the existence of a warm-hot intergalactic medium (WHIM). We expect that the morphology of this material is similar to that of cosmic rays and magnetic fields in large-scale structure, i.e., filaments connecting clusters of galaxies. Direct evidence for the WHIM, either in emission or absorption, is weak.

Measurement of Growth Delay and the Oxygen Enhancement Ratio of Fast Neutron Beam Using Mouse Model System (마우스모델을 이용한 고속중성자선의 성장지연 및 산소증강비의 측정)

  • Eom, Keun-Yong;Park, Hye-Jin;Kwon, Eun-Kyung;Ye, Sung-Joon;Lee, Dong-Han;Wu, Hong-Gyun
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.4
    • /
    • pp.178-183
    • /
    • 2007
  • Neutrons are high LET (linear energy transfer) radiation and cause more damage to the target cells than x-rays or gamma rays. The damage from neutrons is generally considered fatal to a cell and neutrons have a greater tendency to cause cell death through direct interaction on DNA. We performed experiments to measure growth delay ratio and oxygen enhancement ratio (OER) in mouse model system. We inoculated EMT-6 cells to the right hind leg of BALB-c mouse and X-rays and neutron beams were given when the average volume of tumors reached $200-300mm^3$. We irradiated 0, 11, 15.4 Gy of X-ray and 0, 5, 7 Gy of fast neutron beam at normoxic and hypoxic condition. The volume of tumors was measured 3 times per week. In x-ray experiment, growth delay ratio was 1.34 with 11 Gy and 1.33 with 15.4 Gy in normoxic condition compared to in hypoxic condition, respectively. In neutron experiment, growth delay ratio was 0.94 with 5 Gy and 0.98 with 7 Gy, respectively. The OER of neutron beam was 0.97. The neutron beam was more effective than X-ray in the control of hypoxic tumors.

Image Quality Improvement through Energy Spectrum Change for X-ray (엑스선 에너지스펙트럼 변경을 통한 영상 화질 향상에 관한 연구)

  • Kim, Gu;Kim, Neung Gyun;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.71-78
    • /
    • 2021
  • When continuous X-ray are used when acquiring and X-ray image, even the same material may not be accurately represented in the image according to the thickness due to various X-ray energies. To solve this problem, the X-ray energy spectrum was changed to improve the image quality. Using SPEKTR v3.0, an X-ray energy spectrum with an additional filter added and a general X-ray energy spectrum using only a unique filter were obtained. Simulation was performed using the obtained X-ray energy spectrum as a radiation source for Geant4 Application for Tomographic Emission (GATE). Using GATE data, an X-ray image with an additional filter and an image reconstructed from and X-ray image without an additional filter were compared and analyzed through a mono energy image of 74 keV. In the case of using the X-ray energy spectrum without using an additional filter, the amount of X-rays transmitted according to the thickness of the same material is different from the amount that decreases according to the thickness of the material. Similar results were obtained as the amount decreased with the material thickness. In other words, a similar result was obtained when the reduced dose was used with a mono energy. When an X-ray image is obtained by changing an X-ray energy spectrum using an additional filter, a more accurate result of transmission of X-rays may be obtained. In radiological examination, it was confirmed that the appropriate use of the additional filter has a great effect on improving the image quality.