• Title/Summary/Keyword: X rays

Search Result 782, Processing Time 0.029 seconds

A Study of Shielding Properties of X-ray and Gamma in Barium Compounds

  • Seenappa, L.;Manjunatha, H.C.;Chandrika, B.M.;Chikka, Hanumantharayappa
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.1
    • /
    • pp.26-32
    • /
    • 2017
  • Background: Ionizing radiation is known to be harmful to human health. The shielding of ionizing radiation depends on the attenuation which can be achieved by three main rules, i.e. time, distance and absorbing material. Materials and Methods: The mass attenuation coefficient, linear attenuation coefficient, Half Value Layer (HVL) and Tenth Value Layer (TVL) of X-rays (32 keV, 74 keV) and gamma rays (662 keV) are measured in Barium compounds. Results and Discussion: The measured values agree well with the theory. The effective atomic numbers ($Z_{eff}$) and electron density (Ne) of Barium compounds have been computed in the wide energy region 1 keV to 100 GeV using an accurate database of photon-interaction cross sections and the WinXCom program. Conclusion: The mass attenuation coefficient and linear attenuation coefficient for $BaCO_3$ is higher than the $BaCl_2$, $Ba(No_3)_2$ and BaSO4. HVL, TVL and mean free path are lower for $BaCO_3$ than the $BaCl_2$, $Ba(No_3)_2$ and $BaSO_4$. Among the studied barium compounds, $BaCO_3$ is best material for x-ray and gamma shielding.

Surface Dynamics using Coherent X-rays : X-ray Photon Correlation Spectroscopy (코히런트한 X-선을 이용한 표면 거동 연구)

  • Kim Hyeon Jeong
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.22-23
    • /
    • 2003
  • The new method of x-ray photon correlation spectroscopy (XPCS) [1] is developed recently for probing the dynamics of surface height fluctuations as a function of lateral length scale. Measurements were performed on supported polystyrene (PS) films of thicknesses varying from 84 to 333 nm at temperatures above the PS glass transition temperature. Within a range of wave vectors spanning $10^{-3}$ to $10^{-2}$ $nm^{-1}$, good agreement is found between the measured surface dynamics and the theory of overdamped thermal capillary waves on thin films. Quantitatively, the data can be accounted for using the viscosity of bulk PS. (omitted)

  • PDF

Influence of Methylene Blue on Liver Glycogen, Blood Glucose, and Electrolytes in Serum of Rats Exposed to X-rays (Methyleue blue가 X線에 照射된 흰쥐의 肝臟 glycogen, 血糖 및 血液內 電解質에 미치는 影響)

  • Chang, Seung-Han;Nam, Sang-Yul
    • The Korean Journal of Zoology
    • /
    • v.11 no.2
    • /
    • pp.48-54
    • /
    • 1968
  • Male rats of the Albino strain received methylene blue in the dose of 40mg/kg by subcutaneous injection and were subjected to total body X-irradiation, 300 roentgen, at 30 minutes after the injection. The protective effect of methylene blue against the single total body X-irradiation was studied for 24 days after X-irradiation with regard to the levels of liver glycogen, blood glucose, and electrolytes in serum. 1. Total body X-irradiation generally casued an increase in the levels of the liver glycogen and blood glucose in both methylene blue treated and control group during the entire experiment. 2. Methylene blue has been shown to delay slightly the increase of the levels of the liver glycogen and blood glucose when comparing with both groups which were given methylene blue and control saline injection before irradiation in the rats. 3. The delay in the increase in the levels of liver glycogen, in experimental group injected with methylene blue, significantly came in two phases. The first phase appeared at there days after the exposure, the second followed at eighth day. It appeared that the recovery phase was at nineteenth day. 4. During the experimental days the levels of the blood glucose increased generally, methylene blue, however, caused delay in two phases; the first at fifth day, the second at eighteenth day after the exposure to X-rays. 5. In electrolytes, there was not a significant difference. The levels of chloride were, however, slightly decreased in both groups, levels of potassium appeared different in two phases at first day and twelfth day, and the levels of sodium appeared to show irregular changes at the same levels, but there was no significant difference. 6. It may be considered that methylene blue greatly reduces the sensitivity of rats to X-rays, provided that methylene blue is given before the exposure.

  • PDF

The Adequacy of a Cross Table Lateral Cervical X-ray in Severely Traumatized Korean Patients (한국인 중증 외상 환자에서 촬영한 경추 외측면 단순 방사선 영상의 적절성)

  • Lee, Kyung-Hag;Kim, Yeong Cheol;Choi, Seok Ho;Han, Gook Nam;Lee, Soo Un;Lee, Jung Eun;Suh, Gil Joon;Yoon, Yeo-Kyu
    • Journal of Trauma and Injury
    • /
    • v.25 no.4
    • /
    • pp.241-246
    • /
    • 2012
  • Purpose: The objective of this study was to investigate the appropriateness of the cross table lateral cervical X-ray used in the emergency department for severely traumatized Korean patients. Methods: Patients visiting our institution from May 2011 to May 2012, who had injury severity score (ISS) > 15 and who received a cervical X-ray in the emergency department, were included in this study. Data including demographics, ISS score, GCS score, and place where the x-ray was taken were collected to evaluate their relationship with appropriate coverage of the cervical X-ray. The appropriateness of a cervical cross lateral view X-ray was evaluated using exposure of the basion, and the opisthion, as well as the distal level of exposure. Results: Fifty-two patients were included in this study. The identification rate of the basion was 79.2%, and the identification rate of the opisthion was 88.7%. Complete exposure of C7/T1 was accomplished in 3.8% of the patients. The ISS was higher for X-ray taken in the trauma bay, but the range of exposure showed no difference between the places where the X-rays taken. Patients who had exposure of C 5/6 or more had lower body weight and body mass index (BMI) compared with unexposed patients. Conclusion: In severely traumatized Korean patients, the adequacy of the cross table lateral cervical X-ray was inappropriate in most cases. No difference was observed in the exposure range between the places where the X-rays were taken, and patients with less exposure showed higher body weight and higher BMI.

Analysis Method of X-Ray Diffraction Characteristic Values and Measured Strain for Steep Stress Gradient of Metal Material Surface Layer (금속재료 표면층의 급격한 응력구배에 대한 X-Ray회절 특성값과 측정된 변형률의 해석방법)

  • Chang-Suk Han;Chan-Woo Lee
    • Korean Journal of Materials Research
    • /
    • v.33 no.2
    • /
    • pp.54-62
    • /
    • 2023
  • The most comprehensive and particularly reliable method for non-destructively measuring the residual stress of the surface layer of metals is the sin2ψ method. When X-rays were used the relationship of εφψ-sin2ψ measured on the surface layer of the processing metal did not show linearity when the sin2ψ method was used. In this case, since the effective penetration depth changes according to the changing direction of the incident X-ray, σφ becomes a sin2ψ function. Since σφ cannot be used as a constant, the relationship in εφψ-sin2ψ cannot be linear. Therefore, in this paper, the orthogonal function method according to Warren's diffraction theory and the basic profile of normal distribution were synthesized, and the X-ray diffraction profile was calculated and reviewed when there was a linear strain (stress) gradient on the surface. When there is a strain gradient, the X-ray diffraction profile becomes asymmetric, and as a result, the peak position, the position of half-maximum, and the centroid position show different values. The difference between the peak position and the centroid position appeared more clearly as the strain (stress) gradient became larger, and the basic profile width was smaller. The weighted average strain enables stress analysis when there is a strain (stress) gradient, based on the strain value corresponding to the centroid position of the diffracted X-rays. At the 1/5 Imax max height of X-ray diffraction, the position where the diffracted X-ray is divided into two by drawing a straight line parallel to the background, corresponds approximately to the centroid position.

Commissioning of a micro-MLC (mMLC) for Stereotactic Radiosurgery (방사선수술용 4뱅크 마이크로 다엽콜리메이터의 인수 검사)

  • Jeong, Dong-Hyeok;Shin, Kyo-Chul;Kim, Jeung-Kee;Kim, Soo-Kon;Moon, Sun-Rock;Lee, Kang-Kyoo
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.43-50
    • /
    • 2009
  • The 4 bank mico-MLC (mMLC; Acculeaf, Direx, Isral) has been commissioned for clinical use of linac based stereotactic radiosurgery. The geometrical parameters to control the leaves were determined and comparisons between measured and calculated by the calculation model were performed in terms of absolute dose (cGy/100 MU). As a result of evaluating calculated dose for various field sizes and depths of 5 and 10 cm in water in the geometric condition of fixed SSD (source to surface distance) and fixed SCD (source to chamber distance), most of differences were within 1% for 6 MV and 15 MV x-rays. The penumbral widths at the isocenter were approximately evaluated to 0.29~0.43 cm depending on the field size for 6 MV and 0.36~0.51 cm for 15 MV x-rays. The average transmission and leakage for 6 MV and 15 MV x-rays were 6.6% and 7.4% respectively in single level of leaves fully closed. In case of dual level of leaves fully closed the measured transmission is approximately 0.5% for both 6 MV and 15 MV x-rays. Through the commissiong procedure we could verify the dose characteristics of mMLC and approximately evaluate the error ranges for treatment planning system.

  • PDF

A Monte Carlo Study of Dose Enhancement with kilovoltage and megavoltage photons (몬테칼로 기법을 이용한 kV, MV X선에서의 선량증가 효과 비교 평가)

  • Hwang, ChulHwan;Im, In-Chul;Kim, Jung-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.87-94
    • /
    • 2017
  • Monte Carlo simulations were used to assess dose enhancement effects for 60-, 90-, 120-, and 150-kV X-rays, and for 6- and 15-MV X-rays. The MCNPX code was used for a computer simulation of the ICRU slab phantom, and gold, gadolinium, and iron oxide (Fe2O3) were employed as dose enhancement agents. In consideration of the buildup region of the incident energy, agent concentrations of 5, 10, 15, and 20 mg/g were inserted on the surface of the phantom at a depth of 5 cm. Based on baseline values obtained in the absence of dose enhancement agents, a quantitative analysis was performed by evaluating depth-dependent changes in the absorbed energy and the dose enhancement factor (DEF). A higher concentration of dose enhancement agents led to a greater dose enhancement effect with iron oxide, gadolinium, and gold in descending order. For kilovoltage (kV) X-rays, as the incident energy was decreased and as the energy became closer to the ionization potential of the atoms in the enhancement agent, the dose enhancement effect increased. In the megavoltage (MV) X-ray range, dose enhancement was higher at 6 MV compared with 15 MV. However, the overall dose enhancements were significantly lower compared to the results obtained with kV X-rays.

Tuberculous chest wall abscess (결핵성 흉벽농양)

  • Jo, Gyu-Seok;U, Se-Yeong
    • Journal of Chest Surgery
    • /
    • v.17 no.1
    • /
    • pp.140-143
    • /
    • 1984
  • We have experienced 30 patients of tuberculous chest wall abscess which was surgically treated at Kyung Hee University hospital during 6 years from Jan, 1978 to Dec, 1983. We analyze 30 cases of clinical findings and surgically treated, and 20 cases of chest X-rays are available. The results of this sturdy are as follows: 1.Sex ratio ; Male: Female = 1:1.72. 2.Chief complaints are fluctuated mass with or without tenderness or pain and pus from wound. 3.Out of 20 cases of chest x-rays revealed 8 cases of osteolytic lesion, 11 cases of soft tissue swelling, 5 cases of pleural changes and 4 cases of negative findings. 4.We resected partially 43 ribs of 30 patients [average: 1.43 resected] in tuberculous chest wall abscess. 5.Operative methods of tuberculous chest wall abscess were partial resection of destructed or denuded periosteum of ribs and curettage of its surrounding tissues in operative field.

  • PDF

Computer Simulation of Double Osteotomy in Tibia Using Double-Hexapod External Fixator (이중 헥사포드 외고정 기구를 이용한 선천성 왜소증 환자의 경골 교정 시뮬레이션)

  • 주상민;김윤혁
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.916-919
    • /
    • 2004
  • In this paper, we proposed a new method of pre-operative planning for tibial deformity correction using double hexapod external fixator in pseudoacondroplasia. The 3-D computer graphic model of deformed tibia was reconstructed from 3 mm sliced CT data, and CAD model of double hexapod external fixator was developed. The fixator was composed of 170 mm diameter of three rings and 90 mm of twelve struts. The bone deformities and the osteotomy lines for double osteotomy were measured using X-rays, and the necessary joint values to correct the given deformities were obtained by inverse kinematics analysis. The computer graphic simulation was performed to visualize the deformity correction process and evaluate the analysis result. By examining the pre-op and post-op X-rays, the simulation result was in good agreement with the clinical outcomes.

  • PDF

Magnetic field imperfections of in-vacuum undulator on PLS-II beam dynamics

  • Chunjarean, Somjai;Hwan, Shin-Seung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.359-359
    • /
    • 2011
  • Many research applications in basic sciences and biology such as protein crystallography require hard x-rays in the range of 3-20 keV with high brightness. A medium energy storage ring as PLS-II with a beam energy of 3 GeV can meet such high photon energies. In-vacuum undulators (IVU) with a period length of 20 mm and a peak field of 0.97 T are used in the PLS-II ring to produce such X-rays in the fundamental or higher harmonics. Due to the many poles and high fields, insertion devices like wigglers and undulators have a significant impact on the stability of the electron beam with potential degradation of beam quality and life time. Therefore, nonlinear fields must be determined by measurement and evaluated as to their impact on beam stability. Specifically, transverse field roll-off can be a serious detriment to injection in top-up mode and must be corrected. We use magnetic field measurement data to evaluated beam stability by tracking particles using an explicit symplectic integrator in both, transverse and longitudinal planes.

  • PDF