Effects of Physical Factors on Computed Tomography Image Quality

  • Jeon, Min-Cheol;Han, Man-Seok;Jang, Jae-Uk;Kim, Dong-Young
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.227-233
    • /
    • 2017
  • The purpose of this study was to evaluate the effects of X-ray photon energy, tissue density, and the kernel essential for image reconstruction on the image quality by measuring HU and noise. Images were obtained by scanning the RMI density phantom within the CT device, and HU and noise were measured as follows: images were obtained by varying the tube voltages, the tube currents and eight different kernels. The greater the voltage-dependent change in the HU value but the noise was decreased. At all densities, changes in the tube current did not exert any significant influence on the HU value, whereas the noise value gradually decreased as the tube current increased. At all densities, changes in the kernel did not exert any significant influence on the HU value. The noise value gradually increased in the lower kernel range, but rapidly increased in the higher kernel range. HU is influenced by voltage and density, and noise is influenced by voltage, current, kernel, and density. This affects contrast resolution and spatial resolution.

Correction Factor for the Eenergy Dependence of a Optically Stimulated Luminescent Dosimeter in Diagnostic Radiography (진단방사선촬영에서 광자극형광선량계의 에너지의존성에 대한 보정인자)

  • Kim, Jong-Eon;Im, In-Chul;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.261-265
    • /
    • 2011
  • The purpose of this study is to calculate correction factors for energy dependence of a nanoDotdosimeter to measure patient's skin dose in diagnostic radiography. The correction factors were calculated by using the values of mean energy for the RQR standard radiation qualities of IEC publicated by Rosado et al. and the energy response graph of dosimeter relative X-ray on phantom calibration provided by landaur corporation. Results showed the correction factors of 1-1.33 over the tube voltage range of 40-50 kVp. Acquired correction factors are considered to be useful in the clinics for the measurement of accurate skin dose at each tube voltage.

Laser Welding of Seal Tube for Instrumented Irradiation Fuel Test (계장핵연료 조사시험용 실튜브 레이저용접기술)

  • Kim Soo-Sung;Lee Chul-Yong;Kim Woong-Ki;Park Geun-Il;Koh Jinh-Yun;Seo Jun-Seok
    • Journal of Welding and Joining
    • /
    • v.23 no.6
    • /
    • pp.43-48
    • /
    • 2005
  • This work was carried out to obtain sound welds and to select a most suitable binary metal joint among three different dissimilar binary metal combinations such as Zr-4/Ta, Mo/Ta and Ti/Ta(seal tube/sensor sheath) joints fur the instrumented nuclear fuel irradiation test. To do this, Taguchi experimental method was employed to optimize the experimental data. In addition, metallography, micro-focus x-ray radiography and hardness test were conducted to examine the welds. From the weld bead appearance, penetration depth and bead width as well as weld defects standpoint, Zr-4/Ta joint is suggested for the circumferential joining between a seal tube and a sensor sheath. The optimized welding parameters based on Zr-4/Ta joint are suggested as well.

Performance Change in Medical X-ray Image Intensifier Tube Depending on Terms of Use (사용년한에 따른 의료용 X선 영상증강장치의 성능변화)

  • Kim, Min-Jung;Ahn, Sung-Min;Cho, Young-Kwon;Choi, Jung-Hyun;Kim, Sung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.7
    • /
    • pp.253-258
    • /
    • 2010
  • The image intensifier tube that is clinically used gets changed depending on its terms of use. As the brightness gets deteriorated and the performance gets decrease, the X-ray output needs to be increased to maintain the identical diagnosis outcome. As a consequence, the patients are exposed to the increased radiation. Since not many accurate studies have been made, this study measured the conversion factor and resolution depending on the use of the devices that were currently used in Korea. When comparison was made with a device with less than 1 year-use, the conversion factor of a device with 6 year-use got decreased up to 25% while its resolution was reduced from 3.4 lp/mm to 2.5 lp/mm. Such outcome highlights the necessary measures to be supplemented as the increased terms of use implied also the increased radiation exposure among the patients as well as difficulty to conduct an accurate exam.

Correlation Analysis of Control Factors in Automatic Exposure Control of Digital Radiography System Based on Fine Contrast Images (미세 대조도 영상을 기반한 디지털 방사선 영상 시스템의 자동노출제어 조절인자 간의 상관관계 분석)

  • Lim, Se-Hun;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.44 no.1
    • /
    • pp.1-8
    • /
    • 2021
  • The purpose of this study was to analyze the effect of automatic exposure control (AEC) control factors in digital radiography systems based on the fine contrast images using coin phantoms. The AEC control factors were targeted at the range of dominent zone, sensitivity, and density. The dominent zone was divided into cases where a single coin was used to cover the field configuration, and cases where seven coins were used to cover the field configuration. The sensitivity was classified into three stages (200, 400, 800) and the density was classified into three stages (2.5, 0, 2.5). Image quality was evaluated by signal to noise ratio (SNR) and contrast to noise ratio (CNR). Then, the automatically exposed tube current was measured. As a result, the X-ray image of seven coins obtained a result value of about 1.2 times higher for SNR and 1.9 times higher for CNR than the X-ray image for one coin. The tube current was also about 1.6 times higher. In conclusion, In AEC, the higher the field configuration and dominent zone are matched and the higher the density, the lower the sensitivity, which increases the tube current and CNR, which increases the image quality. Therefore, it is judged that the appropriate setting of the range of dominent zone, sensitivity, and density of the control, which is the AEC control factor, could improve the fine contrast of images.

Epidural Emphysema Associated with Subcutaneous Emphysema after Chest Tube Placement: A Case Report (흉관 삽입 후 발생한 피하 기종을 동반한 척추 경막외 기종: 증례 보고)

  • Rho, Ji-Young;Yoo, Seung-Min;Cho, Young-Ah;Lee, Sang-Min
    • Tuberculosis and Respiratory Diseases
    • /
    • v.69 no.5
    • /
    • pp.389-391
    • /
    • 2010
  • Spinal epidural emphysema is rare and has been described secondary to following medical intervention, such as lumbar puncture and epidural analgesia, pneumothorax or pneumomediastinum, degenerative disk disease, epidural abscess, and trauma. Rarely, it occurs after chest tube placement. We report a case of spinal epidural emphysema incidentally noted on HRCT after chest tube placement.

A New Synthetic Route to Wustite

  • 박정철;김돈;이충섭;김동국
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.9
    • /
    • pp.1005-1009
    • /
    • 1999
  • Wustite with NaCl structure is successfully synthesized in a quartz tube sealed under vacuum ( ≒1×10 -3 torr). Hematite in an evacuated quartz tube progressively loses oxide ion at 1373 K. XRD patterns disclose that α-Fe2O3 is transformed into the Fe3O4 after heat treatment at 1373 K for 32 h, and the poorly crystallized FeO is appeared after heat treatment for 48 h. Finally, α-Fe2O3 is completely transformed into the well crystallized Fe 0.935O after heat treatment for 84 h. The electrical resistivity, ac-susceptibility measurement, Mossbauer spectroscopy, and x-ray absorption spectroscopy corroborate the structural phase transition on the iron oxides prepared in a sealed quartz tube depending on the heating time at 1373 K.

Study of Image Properties for Computed Radiography (Computed Radiography의 영상특성에 관한 연구)

  • Ryu, Ki-Hyun;Jung, Jae-Eun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.2
    • /
    • pp.23-31
    • /
    • 2008
  • Computed radiography(CR) has been widely used in the field of diagnostic radiography since digital X-ray image was introduced. The imaging performance of CR system was studied by analyzing the digital image data of the CR images which are the outcomes of the whole imaging system composed of image plate(IP), laser digitizer, analoge-digital convertor, and a given image processing unit. In this study, we used a conventional CR system made by Agfa. From the flat field image of 150$\times$150 image pixels, signal-to-noise ratio(SNR) was calculated. SNR of the CR image increases in proportion to logarithm value of the X-ray exposure irradiated on the IP. SNR is less than about 6 at the exposure below 0.2mR and is more than 10 at the exposure above 0.54mR. In our study, most of images obtained by the smaller exposures less than 2.0mR can not be readable. In general, the minimum value of the SNR ranges from 3 to 5. We obtained modulation transfer function(MTF) by analyzing the bar pattern image which was made under conditions as follows: X-ray tube potential was 55kVp, the IP exposure was 0.54 mR, and the distance between X-ray source to IP was 2m, where bar pattern was located on the IP. MTF is 23% at 2.5lp/mm spatial frequency. Provided that the MTF of noise equivalent modulation is 10%, the CR system has the limiting spatial resolution of 3.2lp/mm. If the image sharpness is evaluated by the spatial frequency where MTF is 50%. the corresponding spatial frequency is 0.5$\sim$0.75lp/mm. MTFA(Modulation Transfer Function Area) is 1.0lp/mm. Compared with the Fuji CR whose MTFA is 1.1lp/mm, Agfa CR in this study shows almost same MTFA performance.

  • PDF

Structural Design of Digital Radiography Detector using Hybrid Method for the Improvement of Response Property by X-ray (X-ray 반응 특성 개선을 위한 Hybrid형 디지털 방사선 검출기의 구조 설계)

  • Kim, Kyo-Tae;Han, Moo-Jae;Kim, Jin-Seon;Heo, Ye-Ji;Oh, Kyung-Min;Park, Ji-Koon;Nam, Sang-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.363-367
    • /
    • 2015
  • Digital radiography is divided into the direct method using photoconductor and indirect method using phosphor based on the principles in acquiring the image information, but both have different advantages and disadvantages. Therefore, this study conducted a preliminary research on the structure of the hybrid detector that combined phosphor and photoconductor to improve the sensitivity of X-ray. As a result, when the tube voltage was adjusted at 30ms of exposure time, the direct structure displayed an overall excellent sensitivity, but at the exposure time of 50ms or more, the hybrid structure displayed a better outcome. This seems to have enough research value considering that various clinical examinations usually include 50ms or more exposure time.

A grid-line suppression technique based on the nonsubsampled contourlet transform in digital radiography

  • Namwoo Kim;Taeyoung Um;Hyun Tae Leem;Bon Tack Koo;Kyuseok Kim;Kyu Bom Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.655-668
    • /
    • 2023
  • In radiography, an antiscatter grid is a well-known device for eliminating unexpected x-ray scatter. We investigate a new stationary grid artifact suppression method based on a nonsubsampled contourlet transform (NSCT) incorporated with Gaussian band-pass filtering. The proposed method has an advantage that extracts the Moiré components while minimizing the loss of image information and apply the prior information of Moiré component positions in multi-decomposition sub-band images. We implemented the proposed algorithm and performed a simulation and an experiment to demonstrate its viability. We did this experiment using an x-ray tube (M-113T, Varian, focal spot size: 0.1 mm), a flat-panel detector (ROSE-M Sensor, Aspenstate, pixel dimension: 3032 × 3800 pixels, pixel size: 0.076 mm), and carbon graphite-interspaced grids (JPI Healthcare, 18 cm × 24 cm, line density: 103 LP/inch and 150 LP/inch, ratio: 5:1, focal distance: 65 cm). Our results indicate that the proposed method successfully suppressed grid artifacts by reducing them without either reducing the spatial resolution or causing negative side effects. Consequently, we anticipate that the proposed method can improve image acquisition in a stationary grid x-ray system as well as in extended x-ray imaging.