A Case of Focal Reexpansion Pulmonary Edema after Chest Tube Insertion (흉관 삽관 후 발생한 국소성 재팽창성 폐부종 1예)

  • Chung, Hye Kyoung;Jang, Won Ho;Kim, Yang Ki;Lee, Young Mok;Hwang, Jung Hwa;Kim, Ki-Up;Uh, Soo-Taek
    • Tuberculosis and Respiratory Diseases
    • /
    • v.67 no.1
    • /
    • pp.59-62
    • /
    • 2009
  • Reexpansion pulmonary edema is not a common phenomenon after chest tube insertion but some reports from 0% to 14%. There are various resulting complications, including acute respiratory distress syndrome. We report a case of focal reexpansion pulmonary edema after chest tube insertion. A 49-year-old male came to the hospital due to ongoing dyspnea and left chest pain for 3 days. On chest X-ray, the patient had a left pneumothrax. We planned to insert a chest tube for symptom relief. To determine whether or not the chest had expanded as a result of the chest tube insertion, the patient underwent repeated chest X-rays the following day. The patient experienced brief respiratory symptoms upon initial suction; a chest PA showed patchy consolidated infiltration at the inserted site. After 5 days of conservative management, the recovered completely.

Measurement of Apron Shielding Rate for X-ray and Gamma-ray (X선 및 감마선에 대한 apron의 차폐율 측정)

  • Park, Myeong-Hwan;Kwon, Deok-Moon
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.245-250
    • /
    • 2007
  • This research measured the shielding rates of apron 0.25 and 0.5 mmPb for X-ray energy in diagnosis radiation system and gamma-ray energy of $^{99m}Tc$-MDP and $^{18}F$-FDG. X-ray energies were measured on effective energy of $26.2{\sim}45.6\;keV$ when additional filtering plate of 0, 2 mmAl is used within the range of tube voltage $40{\sim}120\;kVp$, and at this time, apron 0.5 mmPb has shown about 5.5% of increase in its shielding rate over 0.25 mmPb at the highest quality. Besides, the aprons of the two types have shown high shielding rate of over 90% for direct X-ray and spatial dose rate. And, in case 0.25 and 0.5 mmPb aprons were used at 140keV of $^{99m}Tc$-MDP, the shielding effects were between 30 and 53%, and at high energy of 511 keV, $^{18}F$-FDG, the shielding effects of apron, $1.3{\sim}3.6%$, were very small.

  • PDF

Preliminary Study (1) for Development of Computed Radiography (CR) Image Analysis according to X-ray Non-destructive Test by Wood Species (Computed Radiograhpy (CR)를 통한 목재 수종별 X선 투과 이미지 해석을 위한 기초연구 (1))

  • Song, Jung Il;Kim, Han Seul
    • Journal of Conservation Science
    • /
    • v.37 no.3
    • /
    • pp.220-231
    • /
    • 2021
  • The use of digital copies of film-based analog images and the introduction of digital radiographic imaging systems using image plates gradually replace the non-destructive radiationirradiation method of Cultural Heritage. The quality of images obtained from this technique is affected by conditions such as tube voltage, tube current, and exposure time, type of image acquisition medium, distance of the artifacts from the image acquisition medium, and thickness of artifacts. In this study, we evaluated the grayscale image obtained using GE's Computed Radiograhpy (CR) imaging system, the transmission characteristics of the X-ray source for each tree type (pine, chestnut, sawtooth oak, ginkgo) used in wooden Cultural Heritage, and the signal-to-noise ratio (SNR) and contrast. The GE's CR imaging were analyzed using the Duplex wire image quality indicator, line-pair gauges.

Comparative Study of the Effective Dose from Panoramic Radiography in Dentistry Measured Using a Radiophotoluminescent Glass Dosimeter and an Optically Stimulated Luminescence Detector

  • Lee, Kyeong Hee;Kim, Myeong Seong;Kweon, Dae Cheol;Choi, Jiwon
    • Journal of the Korean Physical Society
    • /
    • v.73 no.9
    • /
    • pp.1377-1384
    • /
    • 2018
  • Accurate measurement of the absorbed dose and the effective dose is required in dental panoramic radiography involving relatively low energy with a rotational X-ray tube system using long exposures. To determine the effectiveness of measuring the irradiation by using passive dosimetry, we compared the entrance skin doses by using a radiophotoluminescent glass dosimeter (RPL) and an optically stimulated luminescence detector (OSL) in a phantom model consisting of nine and 31 transverse sections. The parameters of the panoramic device were set to 80 kV, 4 mA, and 12 s in the standard program mode. The X-ray spectrum was applied in the same manner as the panoramic dose by using the SpekCalc Software. The results indicated a mass attenuation coefficient of $0.008226cm^2/g$, and an effective energy of 34 keV. The equivalent dose between the RPL and the OSL was calculated based on a product of the absorbed doses. The density of the aluminum attenuators was $2.699g/cm^3$. During the panoramic examination, tissue absorption doses with regard to the RPL were a surface dose of $75.33{\mu}Gy$ and a depth dose of $71.77{\mu}Gy$, those with regard to the OSL were surface dose of $9.2{\mu}Gy$ a depth dose of $70.39{\mu}Gy$ and a mean dose of $74.79{\mu}Gy$. The effective dose based on the International Commission on Radiological Protection Publication 103 tissue weighting factor for the RPL were $0.742{\mu}Sv$, $8.9{\mu}Sv$, $2.96{\mu}Sv$ and those for the OSL were $0.754{\mu}Sv$, $9.05{\mu}Sv$, and $3.018{\mu}Sv$ in the parotid and sublingual glands, orbit, and thyroid gland, respectively. The RPL was more effective than the OSL for measuring the absorbed radiation dose in low-energy systems with a rotational X-ray tube.

A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography (C-arm CT의 필수 성능평가 기준 마련을 위한 연구)

  • Kim, Eun-Hye;Park, Hye-Min;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.

Monte Carlo Simulation-Based Mammographic Anti-Scatter Grids to Evaluate Performance of Digital Mammography Detector (디지털 맘모 디텍터 성능평가를 위한 몬테카를로용 산란선 제거 그리드 작성에 관한 연구)

  • Yeji Kim;Hyejin Jo;Yongsu Yoon
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.1-6
    • /
    • 2024
  • In Recent years, there has been a noticeable increase in the global incidence of breast cancer, with approximately 2.3 million cases of female breast cancer reported worldwide in 2020. Numerous studies are currently underway to enhance the accuracy of breast cancer diagnosis through the development of digital mammography detectors. This study aims to create Monte Carlo simulation-based mammographic anti-scatter grids and investigate their utility in evaluating the performance of digital mammography detector. Two types of mammographic anti-scatter grids, MAM-CP and Senographe 600T HF, were created using Monte Carlo simulation software (MCNPX 2.7.0), with grid ratios of 3.7 : 1 and 5 : 1, respectively. The grid physical characteristics (sensitivity, exposure factor, contrast improvement ratio) were calculated based on the KS C IEC60627 in the simulations using two X-ray qualities, RQA-M2 (28 kVp) and MW4 (35 kVp). As the X-ray tube voltage increased from 28 kVp to 35 kVp, sensitivity and exposure factor exhibited a decreasing trend, while contrast improvement ratio demonstrated an increasing trend. With an increase in grid ratio from 3.7 : 1 to 5 : 1, all physical characteristics showed an upward trend. Our results were consistent with a previous study that conducted measurements of physical properties using a real phantom. However, the pattern of change in the contrast improvement ratio with X-ray tube voltage differed from the previous study.

The Assessment of Tube Incidence Angle for Minimizing the Patellofemoral Joint Overlap Distance in Merchant View (Merchant 검사 시 슬개대퇴관절 겹침 최소화를 위한 중심 X선 입사각에 대한 평가)

  • Ko, Ye-Weon;Joo, Young-Cheol;Kim, Min-suk;Go, Yu-Rim
    • Journal of radiological science and technology
    • /
    • v.43 no.3
    • /
    • pp.161-167
    • /
    • 2020
  • This study aimed to found out the effect of patellofemoral overlap distance by changing femur thickness and center X-ray angles in Merchant method images. Based on the femur thickness, it suggested tube angle minimizes overlap. It was conducted by Merchant method, a knee tangential view, and the image was obtained by changing the thigh thickness from 14 to 20 cm and the center ray angle from 60°, 57°, 55°. The images were measured by five researchers using a method of measuring the overlap, which was designed by them. The results showed at 60°, 57°, 55° angle, the patellofemoral overlap distance resulted in 0.47±0.66 to 20.89±0.65 cm, 2.26±0.28 to 15.73±0.62 cm, 1.39 ± 0.83 to 12.49 ± 0.37 cm. However, for 57° and 55°, no overlap in thickness under 14.5 and 14 to 15.5 didn't appear. it showed high correlation between femur thickness and overlap. The difference in the mean value of overlap in each group showed a statistically significant difference (p<0.01), all were classified as independent groups in the post-hoc test. In all images, the patellofemoral overlap distance increased as the thickness increased, and at the average thickness of Korean men and women, overlap decreased when reducing center ray. When conducting Merchant tests on Koreans, it was suggested it would be useful to use 57° angle because it minimize the effects of overlap and intrusions of tibia.

Usability Evaluation of Foot Pedal Switch in X-ray Radiography System (진단용 엑스선 촬영장치에서 발판 스위치의 유용성 평가)

  • Kwon, Hyeokjin;Jung, Hongmoon;Jung, Jaeeun;Jung, Kyunghwan;Won, Doyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.651-658
    • /
    • 2018
  • A foot pedal switch in the diagnosis x-ray radiography system has been researched to improve radiologic technologist works and patient satisfaction. The switch has been installed in the diagnosis x-ray radiography system used in domestic clinics. Quantitative evaluation has been conducted by measuring the exposure dose reproducibility test, tube voltage, mAs, and percentage average error. Qualitative evaluation has been conducted by analysis of the radiologic technologists questionnaire. In the quantitative evaluation for the use of the foot pedal switch, the coefficient of variation was less than 0.05 in the exposure dose reproducibility test. In the mAs test, percentage average error of ${\pm}20%$ was measured. There was no problem raised since it meets the all inspection standards of the diagnosis x-ray generator. In the qualitative evaluation, most of the opinions are that it has a clinical value for the foot pedal switch in the diagnosis x-ray radiography system. Therefore, developing the foot pedal switch for the diagnosis x-ray radiography system can improve effectively the rapidity and accuracy of the radiologic technologist work. In addition, it is effective in decreasing the x-ray exposure of patients and increasing satisfaction for the medical service due to reduction of retaking x-ray.

A Study on X-ray Radiography for the Diagnosis of Screw Insertion Operation of Odontoid Fracture Patients in Cervical (목뼈 치아돌기 골절 환자의 나사못 삽입수술 진단을 위한 X-Ray 촬영법 연구)

  • Byung-Ju-Ahn;In-Soo Kim;Jong-Nam Song;Jae-Bok Han
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.309-315
    • /
    • 2024
  • The Study In order to obtain a Clear Image of fractures in Atlas and Axis of Cervical Spin, this Study obtained Images examined using a Cervical Spin Pantom and a Radiation device, and then Commissioned five Radiologists and three Orthopedic Regent Doctors for Subjective Psychological ROC (Receiver, Operation, Characteristic) Evaluation. As aRresult, the X-ray Tube was Tilted 15° toward the leg to Receive a high score of 29 Points during the Eamination, and the Objective Evaluation Signal-to-noise Ratio (SNR) was 6.032 points, which was high. In Addition, by Tilting the X-ray tube 10° toward the head, it received a high score of 33 points during the Examination, and a high score of 7.840 Points in the objective evaluation. And as a result of Subjectively and Objectively Statistically Evaluating the Examined Images, the Cronbach Alpha value was Calculated as 0.791. Since the Cronbach Alpha value was 0.7 or higher, the Reliability could be Evaluated as 'very good', and the significance probability (p) was Statistically Significant at 0.042 points.

DR Responses to X-Ray: in Terms of Absorbed Energy

  • Kim, Do-Il;Lee, Hyoung-Koo;Kim, Sung-Hyeon;Ho, Dong-Su;Suh, Tae-Suk;Choe, Bo-Young
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.389-392
    • /
    • 2002
  • Digital radiography (DR) is being developed for numerous applications in medical imaging. For understanding DR image, it is necessary to comprehend DR responses to X-ray in terms of absorbed energy. This study reports on the relationship of absorbed energy in the scintillator vs. pixel value of detector. Pixel value and exposure were measured from 50 kVp to 120 kVp until the detector was saturated. For representing radiation produced at the X-ray tube, we used program Srs-78 and compared experimental exposure with calculated exposure. Absorbed energy was acquired using spectrum and we got the relation between the two values.