Production and Assessing Usefulness of the Moving Phantom for Respiration Gated Radiotherapy (호흡동조 방사선치료용 팬텀의 제작 및 유용성 평가)

  • Lee, Yang-Hoon;Lee, Jae-Hee;Yoo, Suk-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.135-144
    • /
    • 2010
  • Purpose: The purpose of this study is that through production of phantom for respiration gated radiotherapy, assessing appropriacy of exposure dose for the therapy using RPM (Real-time Position Management). Materials and Methods: We located measurement object on the phantom for respiration gated radiotherapy made of 2 linear actuator, acrylic panel, stanchion, iron plate ets. to drive (up, down, front, back). Using 4D CT scan, we analyzed patient's respiration and reproduced the movement by computer. On the phantom, we located a 2D-Array (PTW) and an White water phantom (4.5 cm) and used DMLC (interval 2 cm) in the field size $10{\times}10\;cm$, then exposed 21EX X-ray 100 MU, in the case of phantom was (1) static (2) moving (3) gated using RPM respectively gantry $0^{\circ}$ and $90^{\circ}$ We measured with a 0.125 CC ionization chamber (PTW) on the phantom (7.5 cm) in the same condition. Results: Ionization chamber: There were within 0.3% of error with gating respiration and approximately 2% of error without gating in the same condition. 2D-Array: Gantry $90^{\circ}$, field size $10{\times}10\;cm$, using DMLC. There were within 3% of error with gating respiration and approximately 16% of error without gating. Conclusion: The phantom for respiration gated radiotherapy makes plans considering patient's movement, quantitative analysis of exposure dose and proper assessment therapy for IMRT patients using RPM possible.

  • PDF

Characteristic Evaluation of Optically Stimulated Luminescent Dosimeter (OSLD) for Dosimetry (광유도발광선량계(Optically Stimulated Luminescent Dosimeter)의 선량 특성에 관한 고찰)

  • Kim, Jeong-Mi;Jeon, Su-Dong;Back, Geum-Mun;Jo, Young-Pil;Yun, Hwa-Ryong;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.123-129
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate dosimetric characteristics of Optically stimulated luminescent dosimeters (OSLD) for dosimetry Materials and Methods: InLight/OSL $NanoDot^{TM}$ dosimeters was used including $Inlight^{TM}MicroStar$ Reader, Solid Water Phantom, and Linear accelerator ($TRYLOGY^{(R)}$) OSLDs were placed at a Dmax in a solid water phantom and were irradiated with 100 cGy of 6 MV X-rays. Most irradiations were carried out using an SSD set up 100 cm, $10{\times}10\;cm^2$ field and 300 MU/min. The time dependence were measured at 10 minute intervals. The dose dependence were measured from 50 cGy to 600 cGy. The energy dependence was measured for nominal photon beam energies of 6, 15 MV and electron beam energies of 4-20 MeV. The dose rate dependence were also measured for dose rates of 100-1,000 MU/min. Finally, the PDD was measured by OSLDs and Ion-chamber. Results: The reproducibility of OSLD according to the Time flow was evaluated within ${\pm}2.5%$. The result of Linearity of OSLD, the dose was increased linearly up to about the 300 cGy and increased supralinearly above the 300 cGy. Energy and dose rate dependence of the response of OSL detectors were evaluated within ${\pm}2%$ and ${\pm}3%$. $PDD_{10}$ and PDD20 which were measured by OSLD was 66.7%, 38.4% and $PDD_{10}$ and $PDD_{20}$ which were measured by Ion-chamber was 66.6%, 38.3% Conclusion: As a result of analyzing characteration of OSLD, OSLD was evaluated within ${\pm}3%$ according to the change of the time, enregy and dose rate. The $PDD_{10}$ and $PDD_{20}$ are measured by OSLD and ion-chamber were evaluated within 0.3%. The OSL response is linear with a dose in the range 50~300 cGy. It was possible to repeat measurement many times and progress of the measurement of reading is easy. So the stability of the system and linear dose response relationship make it a good for dosimetry.

  • PDF

Accuracy Evaluation of Tumor Therapy during Respiratory Gated Radiation Therapy (호흡동조방사선 치료 시 종양 치료의 정확도 평가)

  • Jang, Eun-Sung;Kang, Soo-Man;Lee, Chol-Soo;Kang, Se-Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.113-122
    • /
    • 2010
  • Purpose: To evaluate the accuracy of a target position at static and dynamic state by using Dynamic phantom for the difference between tumor's actual movement during respiratory gated radiation therapy and skin movement measured by RPM (Real-time Position Management). Materials and Methods: It self-produced Dynamic phantom that moves two-dimensionally to measure a tumor moved by breath. After putting marker block on dynamic phantom, it analyzed the amplitude and status change depending on respiratory time setup in advance by using RPM. It places marker block on dynamic phantom based on this result, inserts Gafchromic EBT film into the target, and investigates 5 Gy respectively at static and dynamic state. And it scanned investigated Gafchromic EBT film and analyzed dose distribution by using automatic calculation. Results: As a result of an analysis of Gafchromic EBT film's radiation amount at static and dynamic state, it could be known that dose distribution involving 90% is distributed within margin of error of 3 mm. Conclusion: As a result of an analysis of dose distribution's change depending on patient's respiratory cycle during respiratory gated radiation therapy, it is expected that the treatment would be possible within recommended margin of error at ICRP 60.

  • PDF

Effect of Dietary Microbial Phytase on Laying Performance, Egg Quality, Phosphorus Utilization and Nutrient Metabolizability in Laying Hens (산란계에 Microbial Phytase 첨가시 산란율, 계란 품질, 인 이용율 및 영양소 대사율에 미치는 영향)

  • Jang, H.D.;Hyun, Y.;Kim, H.S.;Hwang, I.W.;Yoo, J.S.;Kim, H.J.;Shin, S.O.;Hwang, Y.;Zhou, T.X.;Chen, Y.J.;Cho, J.H.;Kim, I.H.
    • Korean Journal of Poultry Science
    • /
    • v.35 no.2
    • /
    • pp.115-121
    • /
    • 2008
  • The study was conducted to evaluate the effects of dietary microbial phytase on egg productivity, egg quality, phosphorus utilization and nutrient digestibility in laying hens. The animals used in the experiment were a total of 120 Hy-Line Brown laying hens (32 weeks old). Dietary treatments included 1) CON (basal diet), 2) LP (low phosphorus diet) 3) NP (low phosphorus diet + 0.03% normal microbial phytase) and 4) CP (low phosphorus diet + 0.03% coated microbial phytase). Six laying hens were allotted to a block (pen) with five replicated. Through the whole period of experiment, egg production was significantly increased in CON and CP treatments compared to LP treatment (P<0.05). CON, CP and NP treatments significantly increased their egg shell breaking strength and egg shell thickness compared to LP treatment (P<0.05). CON, CP and NP treatments resulted higher yolk color and Haugh unit than LP treatment (P<0.05). Calcium and inorganic phosphorus contents in blood were higher in CP treatment compared to LP treatment (P<0.05). Dry matter digestibility and nitrogen digestibility were greater in CP treatment than CON, LP and NP treatments (P<0.05). Crude ash was increased in CON, CP and NP treatments compared to LP treatment (P<0.05). Calcium digestibility and phosphorus digestibility were significantly improved in CP and NP treatments than CON and LP treatments (P<0.05). Calcium retention of CON, CP and NP treatments were higher than LP treatment (P<0.05). Phosphorus retention was increased in CP and NP treatments compared to CON and LP treatments (P<0.05). LP treatment significantly increased their nitrogen, calcium excretion compared to CON, CP and NP treatments (P<0.05). Phosphorus excretion was decreased in LP, CP and NP treatments compared to CON treatment (P<0.05). In conclusion, CP treatment improved egg production, egg quality, inorganic calcium and phosphorus in blood, calcium and phosphorus retention and nutrient digestibility and decreased nitrogen and calcium excretion in laying hens.

Analysis of the Spatial Dose Rates during Dental Panoramic Radiography (치과 파노라마 촬영에서 공간선량률 분석)

  • Ko, Jong-Kyung;Park, Myeong-Hwan;Kim, Yongmin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.509-516
    • /
    • 2016
  • A dental panoramic radiography which usually uses low level X-rays is subject to the Nuclear Safety Act when it is installed for the purpose of education. This paper measures radiation dose and spatial dose rate by usage and thereby aims to verify the effectiveness of radiation safety equipment and provide basic information for radiation safety of radiation workers and students. After glass dosimeter (GD-352M) is attached to direct exposure area, the teeth, and indirect exposure area, the eye lens and the thyroid, on the dental radiography head phantom, these exposure areas are measured. Then, after dividing the horizontal into a $45^{\circ}$, it is separated into seven directions which all includes 30, 60, 90, 120 cm distance. The paper shows that the spatial dose rate is the highest at 30 cm and declines as the distance increases. At 30 cm, the spatial dose rate around the starting area of rotation is $3,840{\mu}Sv/h$, which is four times higher than the lowest level $778{\mu}Sv/h$. Furthermore, the spatial dose rate was $408{\mu}Sv/h$ on average at the distance of 60 cm where radiation workers can be located. From a conservative point of view, It is possible to avoid needless exposure to radiation for the purpose of education. However, in case that an unintended exposure to radiation happens within a radiation controlled area, it is still necessary to educate radiation safety. But according to the current Medical Service Act, in medical institutions, even if they are not installed, the equipment such as interlock are obliged by the Nuclear Safety Law, considering that the spatial dose rate of the educational dental panoramic radiography room is low. It seems to be excessive regulation.

Reduction of Electron Contamination Using a Filter for 6MV Photon Beam (6MV 광자선에서 전자오염 감소에 관한 연구)

  • Lee, Choul-Soo;Yoo, Myung-Jin;Yum, Ha-Yong
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.159-165
    • /
    • 1997
  • Purpose : Secondary electrons generated by interaction between Primary X-rar beam and block tray in megavoltage irradiation, result in excess soft radiation dose to the surface layer To reduce the surface dose from the electron contamination, electron filters were attached under the tray when a customized block was used. Materials and Methods : Cu, Al or Cu/Al combined Plate with different thickness was used as a filter and the surface dose reduction was measured for each case. The measurement to find optimal filter was performed with $10m\times10cm$ field size and 78.5cm source to surface distance. The measurement points are positioned with 2mm intervals from surface to maximum build-up point. To acquire the effect of field size dependence on optimal electron filter, the measurement was performed from $4cm\times4cm\;to\;25cm\times25cm$ field sizes. Results : The surface dose was slowly increased by increasing irradiation field but rapidly increased beyond $15cm\times15cm$ field size. Al plate was found to be inadequate filter because of the failure to have surface dose kept lowering than the dose of deep area. Cu 0.5mm plate and Cu/Al=0.28mm/1.5mm combined plate were found to be optimal filters. By using these 2 filters, the absorbed dose to the surface layer was effectively reduced by $5.5\%,\;11.3\%,\;and\;22.3\%$ for the field size $4cm\times4cm,\;10m\times10cm,\;and\;25cm\times25cm$, respectively. Conclusion : The surface dose attributable to electron contamination had a dependence on field size. The electron contamination was increased when tray was used. Specially the electron contamination in the surface layer was greater when the larger field was used. 0.5mm Cu Plate and Cu/Al=0.28mm/15mm combined plates were selected as optimal electron filters. When the optimal electron filter was attached under the tray, excessive surface dose was decreased effectively The effect of these electron filters was better when a larger field was used.

  • PDF

Measurements of Setup Error and Physiological Movement of Liver by Using Electronic Portal Imaging Device in Patients with Hepatocellular Carcinoma (간암환자에서 Electronic Portal Imaging Device(EPID)를 이용한 자세 오차 및 종양 이동 거리의 객관적 측정)

  • Keum Ki Chang;Lee Sang-wook;Shin Hyun Soo;Kim Gwi Eon;Sung Jinsil Seong;Lee Chang Geol;Chu Sung Sil;Chang Sei-Kyung;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.107-113
    • /
    • 2000
  • Purpose : The goal of this study 닌as to improve the accuracy of three-dimensional conformal radiotherapy (3-D CRT) by measuring the treatment setup error and physiological movement of liver based on the analysis of images which were obtained by electronic portal imaging device (EPID). Materials and Methods : For 10 patients with hepatocellular carcinoma, 4-7 portal images were obtained by using EPID during the radiotherapy from each patient daiiy. We analyzed the setup error and physiological movement of liver based on the verification data. We also determined the safety margin of the tumor in 3-D CRT through the analysis of physiological movement. Results : The setup errors were measured as 3mm with standard deviation 1.70 mm in x direction and 3.7 mm with standard deviation 1.88 mm in y direction respectively. Hence, deviation were smaller than 5mm from the center of each axis. The measured range of liver movement due to the physiological motion was 8.63 mm on the average. Considering the motion of liver and setup error, the safety margin of tumor was at least 15 mm. Conclusion : EPID is a very useful device for the determination of the optimal margin of the tumor, and thus enhance the accuracy and stability of the 3-D CRT in patients with hepatocellular carcinoma.

  • PDF

The Role of Postoperative External Irradiation for the Incompletely Resected Meningiomas (불완전절제된 수막종에서 수술 후 방사선치료의 역할)

  • Kim Tae-Hyun;Yang Dae-Sik;Kim Chul-Young;Choi Myung-Sun
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.85-91
    • /
    • 2000
  • Purpose : The aim of this study is to look for the possible efficacy of postoperative external irradiation for incompletely resected meningiomas. Methods and Materials : From August 198: to January 1997, forty-four patients with intracranial meningioma were treated by postoperative external irradiation. Of the 44 meningiomas, 18 transitional, 13 meningotheliomatous, 6 hemangiopericytic, 4 atypical, 2 fibroblastic and 1 malignant meningioma were identified. We classified all patients into two groups by the histology. The benign group was consisted of the meningotheliomatous, transitional and fibroblastic types. The malignant group was consisted of the atypical, hemangiopericytic and malignat types. In the means of surgery, 37 patients were resected incompletely and 7 patients were managed by biopsy only. After surgery, all patients were received postoperative external irradiation. Radiotherapy was deliverd using Co-60 or 4 MV photon beam to a total dose of 50 to 65 Gy (mean dose 57.4 Gy) with a 1.8 to 2 Gy per fraction. The median follow-up was 48 months (range : 21 $\~$ 101 months). Multivariate analysis of the Influence by age, sex, location, histology and radiation dose on local control has been done using Cox's proportional hazard model. Results : 5-year local control rate was 93.8$\%$ for the benign histology and 51.8$\%$ for the malignant histology (p=0.0110) and overall local control rate at 5 years was 87.4$\%$. The analysis of the prognostic factors, such as age, sex, location, and radiation dose were not significant except for the histology. Conclusion : Adjuvant postoperative external irradiation appears to be significantly improved local control in the patients with incompletely resected meningiomas.

  • PDF

The Results of Radiation Therapy of Limited Stage Small Cell Lung Cancer (국한된 페소세포암의 방사선 치료성적)

  • Kim Sung Hwan;Choi Byung Ok;Gil Hak Joon;Yoon Sei Chul;Bahk Yong Whee;Shinn Kyung Sub;Kim Hoon Kyo;Lee Kyung Sik
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.97-102
    • /
    • 1993
  • A retrospective analysis of various characteristics in 32 limited stage small cell lung cancer patients treated at the Department of Therapeutic Radiology in Kangnam St. Mary's Hospital, Catholic University Medical College from April 1983 to September 1991, was carried out to identify factors which had prognostic significance for survival from initiation of radiation therapy. There were 26 men and 6 women. Median age was 63 years (range: 24-78 years). The follow up duration was 1.5 to 44 months (median: 9 months). External radiation therapy was done with daily 160-180 cGy,5 fraction/week, total of 1000-6660 cGy (median: 4500 cGy) to the mediastinum by 6 MV linear accelerator. Of 32 Patients, 27 ($84.4{\%}$) patients were treated with combined modality (chemotherapy plus radiation therapy), and 5 ($15.6{\%}$) patients were treated with radiation therapy only. Complete responders were 12 patients ($37.5{\%}$), partial responders were 11 ($34.4{\%}$), and no responders were 9($28.1{\%}$). Karnofsky performance status over 70 (p<0.04), chemotherapy regimen (CAV, PV, and CAV+PV) (p<0.04),6 or more cycles of chemotherapy (p<0.007), radiation therapy over 4500 cGy (p<0.03), and radiation therapy responder (CR+PR) (p<0.003) showed a significantly favorable influence on 1 year survival rate. Age (p=0.545), sex (p=0.666), presence of superior vena cava syndrome (p=0.719), prophylactic cranial irradiation (p=0.217), and radiation therapy duration (p=0.491) had no effect on survival. Radiation induced side effects were transient esophagitis in 11 ($34{\%}$), general weakness in 9($28{\%}$), gastrointestinal symptoms in terms of nausea, vomiting and indigestion in 5 ($15{\%}$) and leukopenia in 1 ($3{\%}$).

  • PDF

Tuberculosis in Infants (영아의 결핵)

  • Kim, Ee-Kyung;Nah, Song-Yi;Park, Jin-Young;Choi, Eun-Hwa;Lee, Hoan-Jong
    • Pediatric Infection and Vaccine
    • /
    • v.5 no.1
    • /
    • pp.69-78
    • /
    • 1998
  • Purpose : The risk of severe tuberculous disease such as meningitis or miliary tuberculosis increases as younger is the child at the time of infection. Therefore, the early diagnosis and prompt treatment is mandatory for infants with tuberculosis. This study was undertaken to describe the epidemiology, clinical and radiographic manifestations, and response to therapy in infants with tuberculous disease. Methods : Medical records of 29 infants with tuberculosis diagnosed at the Seoul National University Children's Hospital from July, 1985, to April, 1997, were reviewed, retrospectively. A case of tuberculosis was confirmed if M. tuberculosis was isolated from any body site or if there was histologic proof of tuberculosis. Otherwise, the diagnoses were individualized considering history of contact with contagious adult case, clinical manifestations, chest X-ray findings, result of a Mantoux test reaction with 5 tuberculin unit of PPD, and the response to therapy. Results : The mean age at diagnosis was $7.00{\pm}2.65$ months (range, 3 to 12 months). Twelve cases had isolated pulmonary diseases, and the rest had pulmonary disease and meningitis, 5 cases; pulmonary disease and cervical lymphadenitis, 3; isolated meningitis, 3; and miliary tuberculosis, 6. Source case was identified in 19 cases, 7 of which were detected with retrograde manner. Twenty seven of 29 were symptomatic at their initial visit. The presenting symptoms were mainly respiratory or neurologic, and respiratory difficulty was accompanied in 7 cases. Physical examination revealed wheezing in 7 cases and decreased breath sounds in 9. Hepatomegaly or hepatosplenomegaly were frequent. Chest radiographs showed lung parenchymal disease with hilar lymphadenopathy in 18 cases, and focal or generalized emphysematous change in 7 cases. Conclusion : Most of the infants with tuberculosis are symptomatic at diagnosis, and many of infants with intrathoracic tuberculosis presented with symptoms of bronchial obstruction. When tuberculosis is suspected in an infant, the adult source case should be vigorously investigated to aid in diagnosis and for the prevention of further transmission of tuberculous disease. Almost half of infant tuberculosis are preventable if prophylaxis were given when adult cases were diagnosed.

  • PDF