• Title/Summary/Keyword: X선 투과성

Search Result 56, Processing Time 0.023 seconds

Preparation of Poly(vinyl acetate)/Silver Hollow Microspheres via Suspension Polymerization (현탁중합에 의한 폴리(비닐 아세테이트)/은 중공 미세입자의 제조)

  • Yeum, Jeong-Hyun
    • Polymer(Korea)
    • /
    • v.35 no.5
    • /
    • pp.390-394
    • /
    • 2011
  • Effects of silver nanoparticles on the polymerization rate and morphology of poly(vinyl acetate) (PVAc)/silver microspheres prepared by suspension polymerization of VAc were investigated. Scanning electron microscopy, transmission electron microscopy, X-ray diffraction and atomic absorption spectrometry were used to characterize the morphology and properties of the PVAc/silver microspheres. Due to the change of hydrophilicity of silver nanoparticles, appearance of the microspheres having golf ball-like convave surfaces was observed. Under controlled concentration of surfactant, PVAc/silver microspheres with various hollow structures were synthesized. In the case of silver nanoparticles modified by surfactant, the polymerization rate increased slightly. PVAc/silver microspheres with a conversion up to 80% were prepared via suspension polymerization.

Performance Evaluation of Domestic Prototype Dose Area Product Meter SFT-1 (국산 프로토타입 면적선량계 SFT-1의 성능평가)

  • Lee, Ho-Sun;Han, Seong-Gyu;Roh, Young-Hoon;Lim, Hyun-Jong;Kim, Jung-Min;Kim, Jong-Uk;Chae, Hyun-Sik;Yoon, Yong-Su
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.435-441
    • /
    • 2016
  • The importance of radiation dose display of medical X-ray equipment was emphasized, while third edition of IEC(International Electrotechnical Commission) 60601 started to apply. The existing medical X-ray equipment selected a method for attaching the DAP(Dose Area Product) meter when the dose display. However, because the DAP meter was dependent on all of the income, And it did not yet produced in Korea. So, we received the support of Seoul R&BD Program(Grants No. C1152055) to produce DAP meter prototype of the Domestically technology. In this study, the performance of this prototype was evaluated by comparing the German company's product Evaluation item was an electronic capture performance, radiation dose dependence, radiation quality dependence, energy transmittance, repeatability, light transmittance of 6 entries. And IEC 60580 was based on this evaluation. Evaluation results were electronic capture performance intrinsic error 9.5%, radiation dose dependence limits of variation 1%, repeatability coefficient of variation 2%, energy transmittance 91% each assessment was passed. However radiation quality dependence limits of variation 29%, light transmittance 55% was less than acceptance criteria.

Transmission Dose Estimation Algorithm for Tissue Deficit (조직 결손에 대한 투과선량 계산 알고리즘 보정)

  • Yun Hyong Geun;Chie Eui Kyu;Huh Soon Nyung;Lee Hyoung Koo;Woo Hong Gyun;Shin Kyo Chul;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.186-192
    • /
    • 2002
  • Purpose : Measurement of transmission dose is useful for in vivo dosimetry. In this study, previous algorithm for estimation of transmission dose was modified for use in cases with tissue deficit. Materials and Methods : The beam data was measured with flat solid phantom in various conditions of tissue deficit. New algorithm for correction of transmission dose for tissue deficit was developed by physical reasoning. The algorithm was tested in experimental settings with irregular contours mimicking breast cancer patients using multiple sheets of solid phantoms. Results : The correction algorithm for tissue deficit could accurately reflect the effect of tissue deficit with errors within ${\pm}1.0\%$ in most situations and within ${\pm}3.0\%$ in experimental settings with irregular contours mimicking breast cancer treatment set-up. Conclusion : Developed algorithm could accurately reflect the effect of tissue deficit and irregularly shaped body contour on transmission dosimetry.

Evaluation of the Usefulness of the Transmittance of Metal Filaments Fabricated by 3D Printers in Radiation Therapy (방사선 치료에서 3D 프린터로 제작된 금속 필라멘트의 투과율에 관한 유용성 평가)

  • Kwon, Kyung-Tae;Jang, Hui-Min;Yoon, Myeong-Seong
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.965-973
    • /
    • 2021
  • Since radiation therapy is irradiated with high-energy X-rays in a variety of at least 20 Gy to 80 Gy, a high dose is administered to the local area where the tumor is located, and various side effects of some normal tissues are expected. Currently, in clinical practice, lead, a representative material, is used as an effort to shield normal tissues, but lead is classified as a heavy metal harmful to the human body, and a large amount of skin contact can cause poisoning. Therefore, this study intends to manufacture a measurement sheet that can compensate for the limitations of lead using the materials Tungsten, Brass, and Copper of the 3D printer of the FDM (Fused Deposition Modeling) method and to investigate the penetration performance. Tungsten mixed filament transmission measurement sheet size was 70 × 70 mm and thickness 1, 2, 4 mm using a 3D printer, and a linear accelerator (TrueBeam STx, S/N: 1187) was measured by irradiating 100 MU at SSD 100 cm and 5 cm in water using a water phantom, an ion chamber (FC-65G), and an elcetrometer (PTW UNIDOSE), and the permeability was evaluated. As a result of increasing the measurement sheet of each material by 1 mm, in the case of Tungsten sheet at 3.8 to 3.9 cm in 6 MV, the thickness of the lead shielding body was thinner than 6.5 cm, and in case of Tungsten sheet at 4.5 to 4.6 cm in 15 MV. The sheet was thinner than the existing lead shielding body thickness of 7 cm, and equivalent performance was confirmed. Through this study, the transmittance measurement sheet produced using Tungsten alloy filaments confirmed the possibility of transmission shielding in the high energy region. It has been confirmed that the usability as a substitute is also excellent. It is thought that it can be provided as basic data for the production of shielding agents with 3D printing technology in the future.

A study of the crystallinity and microstructure of the $Si_{1-X}Ge_X$ alloys deposited on the $SiO_2$at various temperatures ($SiO_2$위에 증착된 $Si_{1-X}Ge_X$합금의 증착온도 변화에 따른 결정성 및 미세구조에 관한 연구)

  • Kim, Hong-Seung;Lee, Jeong-Yong;Lee, Seung-Chang;Gang, Sang-Won
    • Korean Journal of Materials Research
    • /
    • v.4 no.4
    • /
    • pp.416-427
    • /
    • 1994
  • The changes of crystallinity and microstructure and the $Si_{1-x}Ge_x/Sio_2$ interfaces of $Si_{1-x}Ge_x$ alloys deposited on amorphous $SiO_{2}$ were studied as a function of deposition temperature. The crystallinity, microstructure, and compositional uniformity of $Si_{1-x}Ge_x$ alloys deposited on the SiOl at different temperature were investigated by X-ray diffraction and transmission electron microscopy. And $Si_{1-x}Ge_x/Sio_2$ interface were investigated by high-resolution transmission electron microscopy. The $Si_{0.7}Ge_{0.3}/Sio_2$ films were deposited on amorphous $SiO_{2}$ at $300^{\circ}C,400^{\circ}C,500^{\circ}C,600^{\circ}C,$ and $700^{\circ}C$ by Si-MBE. In the film deposited at $300^{\circ}C$, only amorphous phase were observed. In the film deposited at $400^{\circ}C$, both amorphous and polycrystalline films were observed. Both phases were deposited simultaneously, but, at initial film growth, amorphous phase prevailed over polycrystalline phase. As the film thickness increased, the fraction of polycrystalline phase increased. At $500^{\circ}C$, thin amorphous layer was observed at lOnm from $SiO_{2}$ surface. In the films deposited at higher than $600^{\circ}C$, only crystalline phase were observed. Polycrystalline films had columnar structure. Compositional uniformity for deposited films were good regardless of deposition temperature. The interfaces of $Si_{1-x}Ge_x/Sio_2$ were flat, whatever polycrystal or amorphous was deposited on $SiO_{2}$.

  • PDF

Highly-permeable Mixed Matrix Membranes Based on SBS-g-POEM Copolymer, ZIF-8 and Ionic Liquid (SBS-g-POEM 공중합체, ZIF-8, 이온성 액체에 기반한 고투과성 혼합 매질 분리막)

  • Kang, Dong A;Kim, Kihoon;Kim, Jong Hak
    • Membrane Journal
    • /
    • v.29 no.1
    • /
    • pp.44-50
    • /
    • 2019
  • In this paper, we developed mixed matrix membranes (MMMs) consisting of SBS-g-POEM block-graft copolymer, ionic liquid (EMIMTFSI) and ZIF-8 nanoparticles to separate a $CO_2/N_2$ gas pair. The SBS-g-POEM is a rubbery block-graft copolymer synthesized through low-cost free-radical polymerization. The EMIMTFSI was dissolved into the SBS-g-POEM matrix and solution synthesized ZIF-8 nanoparticles were also dispersed into the copolymer matrix. The physico-chemical properties of manufactured membranes were characterized by Fourier transform infrared spectroscopy (FT-IR), differential scanning calorimetry (DSC), scanning electron microscopy (SEM), X-ray diffraction (XRD), which showed that the components were compatible with each other. The gas separation performance was confirmed by time-lag measurements showing $CO_2$ permeability of 537.0 barrer and $CO_2/N_2$ selectivity of 15.2. The result represents the EMIMTFSI and ZIF-8 nanoparticles improves the gas permeability more than two-times, without significantly sacrificing the $CO_2/N_2$ selectivity.

Synthesis of Mesoporous Tin Oxide and Its Application as a Gas Sensor (메조세공을 갖는 이산화 주석의 합성 및 가스센서로서의 응용)

  • Kim, Nam-Hyon;Kim, Geon-Joong
    • Applied Chemistry for Engineering
    • /
    • v.18 no.2
    • /
    • pp.142-147
    • /
    • 2007
  • In this study, mesoporous tin oxide was synthesized by sol-gel method using $C_{16}TMABr$ surfactant as a template in a basic condition. The optimum conditions for the synthesis of mesoporous $SnO_2$ were investigated and the obtained samples were characterized by XRD, nitrogen adsorption and TEM analysis. A mesoporous and nanostructured $SnO_2$ gas sensor with Au electrode and Pt heater has been fabricated on alumina substrate as one unit via a screen printing process. Sensing abilities of fabricated sensors were examined for CO and $CH_4$ gases, respectively, at $350^{\circ}C$ in the concentration range of 1~10,000 ppm. Influence of loading amount of palladium impregnated on $SnO_2$ was also tested in detection of those gases. High sensitivity to detecting gases and the fast response speed with stability were obtained with the mesoporous tin oxide sensor as compared to a non-porous one under the same detection conditions.

Synthesis of Heteroatom-Carbon Nanosheets by Solution Plasma Process (솔루션 플라즈마를 이용한 이종 원소 카본 나노시트의 합성)

  • Hyeon, Gwang-Ryong;Jeong, Gwang-Hu;Park, Il-Cho;Lee, Jeong-Hyeong;Han, Min-Su;Kim, Seong-Jong;Saito, Nagahiro
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.114-114
    • /
    • 2018
  • 탄소 재료는 뛰어난 물성에서 다양한 재료로의 응용이 기대되고 있다. 특히, 이종 원소 함유 카본 재료는 전기적 특성과 촉매성의 발현 등 새로운 기능을 카본 재료에 부여할 수 있어서 연료 전지, 에너지 저장, 태양 전지 등에의 응용이 기대되고 있다. 최근, 용액 중의 저온 플라즈마인 솔루션 플라즈마(solution plasma process)를 이용하여 벤젠 용액 등에서 탄소 재료 합성에 성공하였다. 그러나 기존의 연구에서는 솔루션 플라즈마 프로세스를 이용하여 합성한 이종원소 카본은 전도성이 낮아 이종원소의 함유량을 낮추는 고온의 열처리가 필요했다. 따라서 본 연구에서는 우수한 물리적 전기적 특성을 갖는 그래핀(graphene)과 같은 이종 원소 카본 나노시트(heteroatom carbon nanosheets)의 합성 및 메커니즘(mechanism)에 대해 검토하였다. 다양한 이종원소를 포함한 유기용매 안에 바이폴라 펄스 전원에 의한 전압을 두 텅스텐 전극 간에 인가하고, 솔루션 플라즈마를 생성하여 이종원소 카본 재료를 합성했다. 플라즈마 생성은 텅스텐 봉을 전극으로 사용하고 전압을 2.0 kV, 펄스 주파수를 200 kHz, 펄스 폭을 $1.0{\mu}s$, 전극 간 거리를 1.5 mm에서 일정하게 유지하며 200 mL 유기용매 중에서 방전시키는 것으로 재료를 합성했다. 플라즈마 방전 후, 필터을 이용하여 흡인 여과한 뒤 $200^{\circ}C$에서 1 시간 동안 건조 시켰다. 건조 후의 이종원소 카본의 물리적 특성을 원소 분석, X선 회절 법(XRD), 저항률 측정, 투과형 전자 현미경(TEM) 및 라만 분광법, 전자 현미경(SEM), X-선광전자분광기(XPS)등을 이용하여 카본의 형상 및 특성을 분석하였다. 그 결과 다양한 이종원소를 포함한 유기용매 중 2-pyrrolidone을 사용했을 때, 이종 원소 카본 나노시트를 합성하는데 성공하였다. 또한, 이 연구방법을 통해서 솔루션 플라즈마 프로세스를 통한 카본 나노시트 합성의 메커니즘을 규명하였다.

  • PDF

Rheological and Thermal Properties of PLA Nano-composite Modified by Reactive Extrusion (반응압출 공정으로 개질된 PLA 나노복합체의 유변학적 및 열적 물성)

  • Kang, Gyeoung-Soo;Kim, Bong-Shik;Shin, Boo-Young
    • Clean Technology
    • /
    • v.15 no.2
    • /
    • pp.102-108
    • /
    • 2009
  • In this study, poly(lactic acid) (PLA) was modified by reactive extrusion with a functional monomer GMA(glycidyl methacrylate), MMT(montmorillonite), and initiator to enhance the melt strength. Each modified PLA was prepared with different amounts of GMA and MMT and was characterized by measuring thennal- and melt-viscoelastic properties. The degree of dispersion of MMT was measured by X-ray diffraction(XRD) and transmission electron microscopy(TEM). The glass transition temperature($T_g$) of modified PLA-GMA-MMT nanocomposite decreased with increasing GMA content, but was a little affected by the amount of MMT. Surface analysis showed that the nanocomposite became more intercalated than exfoliated as the amount of MMT increases. The complex viscosity and storage modulus of the nano-composite were greatly increased by addition of MMT.

Conservation Treatment and Study on Manufacturing Techniques of Jija Chongtong Gun in the Middle of Joseon Dynasty (조선 중기 제작된 지자총통의 보존처리와 제작기법 연구 -동아대학교 석당박물관 소장 보물 지자총통을 중심으로-)

  • Nam Dohyeon;Park Younghwan;Lee Jaesung
    • Conservation Science in Museum
    • /
    • v.30
    • /
    • pp.23-46
    • /
    • 2023
  • The Jija Chongtong Gun, owned by Seokdang Museum of Dong-A University, is a tubedstyle heavy weapon of the battlefield in the mid-Joseon Dynasty and is the second largest firearm after Cheonja Chongtong. The original surface color of the Jija Chongtong Gun was obscured by foreign substances and therefore it was judged that its condition requires the conservation treatment. For stable conservation treatment, gamma ray and X-ray non-destructive transmission surveys was conducted to determine the internal structure and conservation condition. And the component analysis on the material components and surface contaminants of Jija Chongtong Gun was conducted by utilizing the p-XRF component analysis, SEM-EDS component analysis, and XRD analysis. As a result of the gamma-ray and X-ray non-destructive transmission investigation, a large amount of air bubbles was observed inside Jija Chongtong Gun, and the part that appeared to be a chaplet by visual observation was not identified. As a result of gamma-ray and p-XRF component analysis, it was confirmed that Jija Chongtong Gun was bronze made of copper (Cu), tin (Sn), and lead (Pb) alloy. As a result of surface analysis of foreign substances using SEM-EDS, it was confirmed that the main components of white foreign substances were calcium (Ca), sulfur (S), and titanium (Ti). Titanium was presumed to be titanium dioxide (TiO2), the main component of white correction fluid. The red foreign substance was confirmed to contain barium (Ba) as its main ingredient, and was presumed to be barium sulfate (BaSO4), an extender pigment in paint. White and red contaminants, mainly composed of titanium and barium, are presumed to have been deposited on the surface in recent years. The yellow foreign substances were confirmed to be aluminum (Al) and silicon (Si), and were presumed to have originated from soil components. As a result of SEM-EDS and XRD component analysis, the white foreign substance was confirmed to be gypsum (CaS). Based on the results of component analysis, surface impurities were removed, stabilization treatment, and strengthening treatment were performed. During the conservation process, unknown inscriptions Woo (右), Byeong (兵), Sang (上), and Yi (二) were discovered through a portable microscope and precise 3D scanning. In addition, the carving method, depth, and width of the inscription were measured. Woo Byeong Sang is located above Happo Fortress in Changwon, and Yi can be identified as the second hill.