• 제목/요약/키워드: X선 가시화

검색결과 16건 처리시간 0.031초

상용 방사선 X선 발생 장치를 이용한 PEMFC 내부 물 분포 가시화를 위한 실험적 연구 (Experimental Study on Visualization of Water Distribution Inside PEMFC Using a Commercial Radiation X-ray Generator)

  • 김영현;김태준;최선호;유동인
    • 한국가시화정보학회지
    • /
    • 제22권2호
    • /
    • pp.20-26
    • /
    • 2024
  • Water management is crucial for the performance, durability, and stability of Polymer Electrolyte Membrane Fuel Cells (PEMFCs). Due to its importance, various methods for visualizing PEMFC's internal water distribution have been adapted to study and manage water within the cells. However, these methods often require large facilities, leading to high costs and significant barriers to entry. This study addresses these challenges by using a commercial Radiation (X-ray) Generator (RG) for internal water distribution visualization and comparing the results with synchrotron X-ray data from the Pohang Accelerator Laboratory (PAL) 9D beamline. Despite the lower resolution and potential beam distortion challenges, the RG shows promise for PEMFC water distribution visualization, suggesting the need for further research to refine water attenuation coefficients and build-up factors for improved measurement accuracy.

X선 영상기법을 이용한 고분자 전해질형 연료전지의 수분분포 가시화 (Visualization of Water Distribution in a Polymer Electrolyte Fuel Cell Using an X-ray Imaging Technique)

  • 임남윤;박구곤;김창수;이상준
    • 한국가시화정보학회지
    • /
    • 제5권2호
    • /
    • pp.33-38
    • /
    • 2007
  • Water management in polymer electrolyte fuel cell (PEFC) has been receiving large attention as an important issue in practical applications. Proper water management is vital to achieve high performance and durability of PEFC. In this study, an X-ray imaging technique was employed to visualize the water distribution in a PEFC quantitatively. X-ray images of the PEFC components with and without water were distinguished clearly. From the visualized X-ray images, we could evaluate the water distribution in the region between separator and gas diffusion layer (GDL) quantitatively. In addition, the contact angle of water in the micro-channels was also clearly visualized.

미세 X선 단층촬영 기법의 개발과 적용 (Development of X-ray Micro Computed Tomography and Applications)

  • 김승곤;임재홍;김보흠;이의재;이상준
    • 한국가시화정보학회지
    • /
    • 제8권2호
    • /
    • pp.45-50
    • /
    • 2010
  • The objective of this study is to elucidate the feasibility of synchrotron X-ray micro CT as a non-destructive imaging method to visualize the three-dimensional morphological structures of biological and non-biological samples. The experiments were conducted in 7B2 X-ray micro CT beamline in Pohang Accelerate Laboratory (PAL). A rotational 3-axis stage was specially designed for $0^{\circ}-180^{\circ}$ scanning of test samples. Preliminary tests were performed for opaque samples including a mosquito head, a plant seed and gas diffusion layer (GDL) of polymer electrolyte fuel cell to verify the feasibility of the X-ray micro CT. It visualized clearly the internal structure of all the test samples, supporting its usefulness.

X-ray 시스템의 구성 및 TSV (Through Silicon Via) 결함 검출을 위한 응용

  • 김명진;김형철
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.108.1-108.1
    • /
    • 2014
  • 제품의 고성능 사양을 위해 초미소 크기(Nano Size)의 구조를 갖는 제품들이 일상에서 자주 등장한다. 대표 제품은 주변에서 쉽게 접할 수 있는 전자제품의 반도체 칩이다. 반도체 칩 소자 구조는 크기를 줄이는 것 외에도 적층을 통해 소자의 집적도를 높이는 방향으로 진화를 하고 있다. 복잡한 구조로 인해 발생되는 여러 반도체 결함 중에 TSV 결함은 현재 진화하는 반도체 칩의 구조를 대변하는 대표 결함이다. 이 결함을 효율적으로 검출하고 다루기 위해서는 초미소 크기(Nano Size)의 결함을 비파괴적인 방법으로 가시화하고 분석하는 장비가 필요하다. X-ray 시스템은 이러한 요구를 해결하는 훌룡한 한 방법이다. 이 논문에서는 X-ray 시스템의 구성 및 위의 TSV 결함을 검출하고 분석하기 위한 시스템의 특징에 대해 설명을 한다. X-ray 시스템은 크게 X선을 발생시키는 X선튜브와 대상 물체를 투과한 X선을 영상화하는 디텍터, 대상물체의 영상화를 위해 물체를 적절하게 구동시키는 이동장치로 구성되어 있다. 초미소크기(Nano Size)의 결함 검출을 위해서는 X선 튜브, 디텍터, 이동장치에 요구되는 사양의 복잡도, 정밀도는 이러한 시스템의 개발을 어렵게 만든다. 이 논문에서는 이러한 시스템을 개발 시에 시스템 핵심 요소의 특징을 분석한다.

  • PDF

X선 위상차 가시화 기법을 이용한 GDI 인젝터 노즐 근방의 분무 간 상호간섭 해석 (Analyzing the Spray-to-spray Interaction of GDI Injector Nozzle in the Near-field Using X-ray Phase-Contrast Imaging)

  • 배규한;문석수
    • 한국분무공학회지
    • /
    • 제25권2호
    • /
    • pp.60-67
    • /
    • 2020
  • Despite its benefit in engine thermal efficiency, gasoline-direct-injection (GDI) engines generate substantial particulate matter (PM) emissions compared to conventional port-fuel-injection (PFI) engines. One of the reasons for this is that the spray collapse caused by the spray-to-spray interaction forms the locally rich fuel-air mixture and increases the fuel wall film. Previous studies have investigated the spray collapse phenomenon through the macroscopic observation of spray behavior using laser optical techniques, but it is somewhat difficult to understand the interaction between sprays that is initiated in the near-nozzle region within 10 mm from the nozzle exit. In this study, the spray structure, droplet size and velocity data were obtained using an X-ray imaging technique from the near-nozzle to the downstream of the spray to investigate the spray-to-spray interaction and discuss the effects of spray collapse on local droplet size and velocity distribution. It was found that as the ambient density increases, the spray collapse was promoted due to the intensified spray-to-spray interaction, thereby increasing the local droplet size and velocity from the near-nozzle region as a result of droplet collision/coalescence.

나비 펌프의 구조와 동적 거동의 in vivo 가시화 (In vivo visualization of liquid-feeding phenomena of a butterfly)

  • 이승철;김보흠;이상준
    • 한국가시화정보학회지
    • /
    • 제9권4호
    • /
    • pp.69-73
    • /
    • 2011
  • Butterflies have been known to suck viscous liquids through a long, cylindrical proboscis using the large pressure difference formulated by the cyclic expansion and contraction of a muscular pump located inside their head. However, there are few studies on the liquid-feeding phenomena in a live butterfly, because it is hard to observe the internal morphological structures under in vivo condition. In this study, the dynamic motion of the pump system in a butterfly was in vivo visualized using synchrotron X-ray micro-imaging technique to analyze the liquid-feeding mechanism. The period of the liquid-feeding process is about 0.3sec. The expansion stage is about two times larger than the contraction stage in one cycle. The cyclic variation of pump volume generate large negative suction pressure and the pressure difference inside the long proboscis of a butterfly is estimated to be larger than 1atm.

가속기 X선 영상기법을 이용한 애기장대 뿌리털의 물 흡수과정 가시화 (Visualization of Water-uptake Process in Excised Roots of Arabidopsis using Synchrotron X-ray Imaging Technique)

  • 황배근;김혜구;이상준
    • 한국가시화정보학회지
    • /
    • 제8권4호
    • /
    • pp.48-53
    • /
    • 2010
  • Water-uptake through roots, is an essential process of the water flow in plants. Its visualization is very useful for understanding sap flow dynamics at whole plant level. In this study, the tips of Arabidopsis' root hairs were excised and exposed to repeated dehydration and rehydration processes. The water-refilling through individual xylem vessels was visualized using the synchrotron X-ray micro-imaging technique. The high temporal resolution ($2\;{\mu}m$) and beam intensity of the X-ray source allowed to acquisition of consecutive X-ray images of the water-refilling process up to 10 frames/sec. Various flow patterns were observed and the ascending speed of the water-air interfaces was analyzed. The relation between the water-rising height and ascending speed was also analyzed. The present results would provide better alternative for investigating sap flows in roots.

X-ray Micro-Imaging 기법 소개 및 불투명 튜브 내부의 마이크로 버블 가시화 연구 (X-ray Micro-Imaging Technique and Its Application to Micro-Bubbles in an Opaque Tube)

  • 이상준;김석;백부근
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.31-34
    • /
    • 2002
  • Imaging techniques using x-ray beam at high energies (>6KeV) such as contact radiography, projection microscopy, and tomography have been used to nondestructively discern internal structure of objects in material science, biology, and medicine. This paper introduces the x-ray micro-imaging method using 1B2 micro-probe line of PAL (Pohang Accelerator Laboratory). Cross-sectional information on low electron density materials can be obtained by probing a sample with coherent synchrotron x-ray beam in an in-line holography setup. Living organism such as plants, insects are practically transparent to high energy x-rays and create phase shift images of x-ray wave front. X-ray micro-images of micro-bubbles of $20\~120\;{\mu}m$ diameter in an opaque tube were recorded. Clear phase contrast images were obtained at Interfaces between bubbles and surrounding liquid due to different decrements of refractive index.

  • PDF

X-ray 미세 영상기법을 이용한 불투명 튜브 내부 미세기포의 크기 및 속도 동시 측정 (Simultaneous measurement of size and velocity of micro-bubbles in an opaque tube using X-ray micro-imaging technique)

  • 김석;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2003년도 추계학술대회 논문집
    • /
    • pp.45-46
    • /
    • 2003
  • The x-ray micro-imaging technique was employed to measure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Phase contrast images were obtained at interfaces of micro-bubbles between water and air due to different refractive index. Micro-bubbles of $20\~120{\mu}m$ diameter moving upward in an opaque tube $(\phi=2.7mm)$ were tested. For two different working fluids of tap water and DI water, the measured velocity of micro-bubbles is roughly proportional to the square of bubble size.

  • PDF