• Title/Summary/Keyword: X선량

Search Result 899, Processing Time 0.025 seconds

Energy Distribution of X-rays from Medical Linear Accelerator (의료용 선형 가속기에서 발생된 X-선의 에너지 분포에 대한 고찰)

  • 김진기;김정홍;김부길
    • Progress in Medical Physics
    • /
    • v.2 no.1
    • /
    • pp.29-35
    • /
    • 1991
  • For accureate treatment planning, new models of dose calculations are being developed which require the knowledge of the energy spectra and angular distributions of the X-rays incident on the surface of the material. In this present study, we applied the Monte Carlo methods to the systematic analysis of the spectra distribution of X-ray beams produced by medical linear accelerator. As expected, the spectra become softer as the distance is farther from the central axis. also, its influenced by the geometrical dffect of head system.

  • PDF

The Study for Radio Protection According to a Possible Danger of Exposure During low energy X-ray Examination (저 에너지 방사선 검사 시 노출 위험성에 따른 피폭선량 방어연구)

  • Lim, Cheong-Hwan;Jeong, Cheon-Soo
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2011.05a
    • /
    • pp.187-188
    • /
    • 2011
  • 저 에너지 방사선검사 시 부득이하게 방사선 노출을 받게 되는 방사선 작업종사자나 환자의 보호자가 위치와 거리에 따른 방사선 피폭 선량의 감소 방안을 알아보고자 한다. Ion chamber mode 2026c, Reader기 20X6-1800을 사용하여 구강내 검사와 구강외 검사의 각각 검사실과 조정실에서의 관전압의 변화, 관전류와 조사시간의 변화, 조사방향의 변화에 따라 선량을 측정하였다. 그 결과 검사실 안에서는 최고선량이 평균 $702.8{\mu}R$으로 측정 되었으며, 조정실 안에서 측정하였을 경우 $20{\mu}R$이하의 낮은 선량을 보였으며, 후방검사보다 측방검사가 낮은 선량으로 나타났다. 방사선검사 시 위치와 거리에 따른 조사선량을 비교 분석하여, 적절한 거리 확보와 조사되는 중심방사선을 기준으로 측방($90{\sim}135^{\circ}$)에 위치함으로써 방사선 방어에 도움을 줄 것이며, 차폐문을 이용하여 방사선 피폭으로부터 감소 효과를 볼 수 있을 것이다.

  • PDF

구동 팬톰 시스템을 통한 내부 장기 움직임의 선량 평가

  • Kim, Jae-Gyun;Kim, Yun-Jong;Lee, Dong-Han;Lee, Dong-Hun;Kim, Mi-Suk;Jo, Cheol-Gu;Ryu, Seong-Ryeol;Yang, Gwang-Mo;Yu, Hyeong-Jun;Ji, Yeong-Hun
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.64-67
    • /
    • 2005
  • 본 연구의 목적은 호흡 운동에 영향을 받는 내부 장기의 움직임을 정량적으로 분석하고, 그 결과를 토대로 움직이는 내부 장기의 선량 분포를 측정하고 평가하는 것이다. 그리고 이전에 보고된 논문에서 개발된 움직임 감소 장치의 사용 유무에 따른 내부 장기의 선량 분포 또한 분석하는 것이다. 이를 위하여 1차원적으로 움직이는 구동 팬톰 시스템을 개발하였고, 6MV X-ray에서 Kodak X-omat V 필름을 사용하여 움직이는 내부 장기의 선량분포를 실험적으로 측정하였다. 이 결과로부터 호흡 운동으로 인한 움직이는 내부 장기 및 종양에 조사되는 선량의 부정확도를 평가할 수 있었고, 움직임 감소 장치를 사용했을 때 선량의 부정확도가 감소함을 확인할 수 있었다.

  • PDF

Investigation of organ dose difference of age phantoms for medical X-ray examinations (X선 촬영 시 연령별 장기선량 차이 연구)

  • Park, Sang-Hyun;Lee, Choon-Sik;Kim, Woo-Ran;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.1
    • /
    • pp.35-42
    • /
    • 2003
  • Methodology for calculating the organ equivalent doses and the effective doses of pediatric and adult patients undergoing medical X-ray examinations were established. The MIRD-type mathematical phantoms of 4 age groups were constructed with addition of the esophagus to the same phantoms. Two typical examination procedures, chest PA and abdomen AP, were simulated for the pediatric patients as well as the adult as illustrative examples. The results confirmed that patients pick up approximate 0.03 mSv of effective dose from a single chest PA examination, and 0.4 to 1.7 mSv from an abdomen AP examination depending on the ages. For dose calculations where irradiation is made with a limited field, the details of the position, size and shape of the organs and the organ depth from the entrance surface considerably affect the resulting doses. Therefore, it is important to optimize radiation protection by control of X-ray properties and beam examination field. The calculation result, provided in this study, can be used to implement optimization for medical radiation protection.

Implementation and Evaluation of Optimal Dose Control for Portable Detectors with SiPM (SiPM을 통한 휴대용 검출기의 최적 선량 제어에 대한 구현 및 평가)

  • Byung-Wuk Kang;Sun-Kook Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1139-1147
    • /
    • 2023
  • The purpose of this paper is to present and evaluate the performance of a method for controlling the dose for optimal image acquisition while minimizing patient exposure by applying a small-sized Photomultiplier(SiPM) sensor inside a portable detector. Portable detectors have the advantage of being able to quickly access the patient's location for rapid diagnosis, but this mobility comes with the challenge of dose control. This paper presents a method to identify the dose that can have the DQE and optimal image quality of the detector through image evaluation based on IEC62220-1-1, an international standard for X-ray imaging devices, and to identify the optimal dose by matching the ADU of the image and the output of the SiPM Sensor. The Skull AP image was acquired by implementing the detector manufacturer's reference dose. The optimal dose was 342.8 µGy, and the optimal controlled dose was 148.3 µGy, which is 57 % of the manufacturer's reference dose. The Chest AP image was 81.9 µGy and the optimal controlled dose was 27.9 µGy, which is a high dose reduction effect of 66 %. In addition, the two images were analyzed by five radiologists and found to have no clinically significant difference in anatomical delineation.

Doses of Electron Beam and X-ray Irradiation for Inhibition of Development and Reproduction in Four Insect Pests (4종 해충의 발육과 생식에 대한 전자빔과 X-ray의 억제선량)

  • Yun, Seung-Hwan;Kim, Minjun;Kim, Hyunah;Lee, Seon-Woo;Yoo, Dae Hyun;Kim, Hyun Kyung;Koo, Hyun-Na;Kim, Gil-Hah
    • Korean journal of applied entomology
    • /
    • v.53 no.4
    • /
    • pp.391-398
    • /
    • 2014
  • This study investigated inhibitory doses of electron beam and X-ray irradiation by comparing their effects on the development and reproduction of four insect pests (Myzus persicae, Tetranychus urticae, Liriomyza trifolii, and Frankliniella intonsa). When M. persicae nymphs were irradiated with 100 Gy of electron beam and 30 Gy of X-ray beam, offspring production by adults that developed from the treated nymphs was completely inhibited. When M. persicae adults were irradiated with 200 Gy of electron beam and 50 Gy of X-ray beam, emergence of the $F_1$ generation was inhibited. However, these two ionizing radiations did not affect adult longevity. When T. urticae eggs were irradiated with 150 Gy of electron beam and 50 Gy of X-ray beam, egg hatching was completely inhibited. When L. trifolii pupae were irradiated, the emergence rate decreased with increasing doses of X-ray irradiation. After F. intonsa adults were irradiated with 250 Gy of electron beam and 200 Gy of X-ray beam, egg hatching of the $F_1$ generation was completely suppressed.

The Enhancement of Skin Sparing by Tray Materials for High Energy Photon Beam (고에너지 광자선치료에서 고정판 흡수물질을 이용한 피부보호효과의 향상)

  • Chu, Sung-Sil;Lee, Chang-Geol;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.449-454
    • /
    • 1993
  • The skin sparing effect associated with high energy x-ray or gamma ray beams may be reduce or lost under certain conditions of treatment. Current trends in using large fields. Shield carrying trays, compensating filters, and isocentric methods of treatment have posed problems of increased skin dose which sometimes become a limiting factor in giving adquate tumor doses. We used the shallow ion chamber to measure the phantom surface dose and the physical treatment variables for Co-60 gamma ray, 4MV and 10 MV x-ray beam. The dependence of percent surface dose on field sizes, atomic number of the shielding tray materials and its distance from the surface for 4, 10MV x-rays and Co-60 gamma ray is qualitatively similar. The use of 2 mm thick tin filter is recommended for situations where a low atomic number tray is introduced into the beam at distances less than 15 cm from the surface and with the large field sized for 4 MV x-ray beam. In case of Co-60 gamma ray, the lead glass tray is suitable for enhancement of skin sparing. Also, the filter distance should be as large as possible to achieve substantial skin sparing.

  • PDF

The Impact of Tissue Inhomogeneity Corrections in the Treatment of Prostate Cancer with Intensity-Modulated Radiation Therapy (전립선암의 세기조절 방사선 치료시 밀도보정의 효과)

  • Han Youngyih;Park Won;Huh Seung Jae
    • Progress in Medical Physics
    • /
    • v.15 no.3
    • /
    • pp.149-155
    • /
    • 2004
  • Purpose: To investigate the effects of tissue inhomogeneity corrections on the dose delivered to prostate cancer patients treated with Intensity-Modulated Radiation Therapy (IMRT). Methods and Materials: For five prostate cancer patients, IMRT treatment plans were generated using 6 MV or 10 MV X-rays. In each plan, seven equally spaced ports of photon beams were directed to the isocenter, neglecting the tissue heterogeneity in the body. The dose at the isocenter, mean dose, maximum dose, minimum dose and volume that received more than 95% of the isocenter dose in the planning target volume ( $V_{p>95%}$) were measured. The maximum doses to the rectum and the bladder, and the volumes that received more than 50, 75 and 90% of the prescribed dose were measured. Treatment plans were then recomputed using tissue inhomogeneity correction maintaining the intensity profiles and monitor units of each port. The prescription point dose and other dosimetric parameters were remeasured. Results: The inhomogeneity correction reduced the prescription point dose by an average 4.9 and 4.0% with 6 and 10 MV X-rays, respectively. The average reductions of the $V_{p>95%}$ were 0.8 and 0.9% with the 6 and 10 MV X-rays, respectively. The mean doses in the PTV were reduced by an average of 4.2 and 3.4% with the 6 and 10 MV X-rays, respectively. The irradiated volume parameters in the rectum and bladder were less decreased; less than 2.1 % (1.2%) of the reduction in the rectum (bladder). The average reductions in the mean dose were 1.0 and 0.5% in the rectum and bladder, respectively. Conclusions: Neglect of tissue inhomogeneity in the IMRT treatment of prostate cancer gives rise to a notable overestimation of the dose delivered to the target, whereas the impact of tissue inhomogeneity correction to the surrounding critical organs is less significant.

  • PDF

대두의 방사선 감수성에 관한 연구(예보)

  • Shin-Han Kwon;Kun-Hyuk Im;Byeo-Jeong Kim
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.2
    • /
    • pp.46-49
    • /
    • 1964
  • 1. 본 시험에 사용된 선량범위내에서는 기건종자에 의한 Thermal neutron이나 X-ray의 처리가 발아율에 크게 영향을 미치지 못하였는데 Fast neutorn 처리종자의 발아율은 선량의 증가에 따라 거의 직선적 저하를 보였다. 2. 선량의 증가에 따라 기형엽발생율은 증가하였으며 특히 Fast neutron에서는 동일 flux일망정 Thermal neutron 조사구에 비해 발생율은 높다. 3. 저선량에서의 기형엽출현은 유식물기에서만 봇 수 있으며 성장함에 따라 회복한다. 이는 정상세포와 이상세포간의 분열속도의 차에 기인되는 상 싶다. 4. 같은 선량에서는 Fast neutron이 Thermal neutron에 비해 그 영향력이 크다는 것이 확실하며 이는 Energy의 차에서 오는 결과이다. 5. 일반적으로 선량의 증가에 따라 성숙이 연장되는 경향이 있었으며, 반면에 아주 희귀하기는 하나 개화와 성숙이 촉진되는 고체도 발견되었다. 6. 선량의 증가에따라 다소 왜소화되기는 하나 저선량에서는 오히려 유의성은 없으나 초장이 증가하였다. 7. 생육초기와 생육종기에 있어서의 선량에 따르는 초장에 대한 영향은 그 초기에 있어서 더 현저하며 성장함에 따라 회복되는 경향을 보인다. 8. 발아와 생육에 별 지장이 없이 재배할 수 있는 선량범위는 Thermal neutron에서 $1O^13$ N/$cm^2$, Fast neutron에서 5$\times$$1O^12$N/$cm^2$ 이하이면 무난할 것이며, X-ray는 본 시험에 이용한 32 Kr 이상에서도 이용에 지장이 없을 것이다.

  • PDF

The Measurement and Evaluation of X-ray Characteristics of Cadmium Sulfide as a Multi-function Dosimeter (다기능 선량계로서의 Cadmium sulfide의 X-선에 대한 특성 평가)

  • Park, Sung-Kwang;Park, Young-Min;Cho, Heung-Lae;Nam, Sang-Hee
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.161-166
    • /
    • 2003
  • To evaluate the performance of cadmium sulfide as a multi-function X-ray dosimeter, we made an X-ray detector that was based on cadmium sulfide using evaporation technology, and measured its response to X-ray exposure. The voltages of cadmium sulfide were measured on the various X-ray tube potentials, X-ray tube currents and exposure times. The regression analysis of the voltage response of CdS on the tube-potential variation was y=0.0995x-0.1146 ($R^2$=0.9595, $\sigma$=0.08, standard error=2%) and the regression analysis of the voltage response of CdS on the tube-potential variation was y=0.0439x+1.1891 ($R^2$=0.9021, $\sigma$=0.04, standard error=1.8%) The regression analysis of the voltage response of CdS on the X-ray exposure time variation was y=8.2853+5.5878 ($R^2$=0.7287, $\sigma$=0.06, standard error=1.9%). In conclusion, cadmium sulfide responded linearly to the variation X-ray conditions, suggesting cadmium sulfide to be a feasible X-ray sensor of multi-function dosimeter related instruments.

  • PDF