• Title/Summary/Keyword: Wrist Motion

Search Result 203, Processing Time 0.031 seconds

Comparison of the Outcomes according to the Injury Type of the Short Radiolunate Ligament in Fracture-Dislocation of the Radiocarpal Joint (요수근 관절의 골절-탈구에서 단요월상인대의 손상 형태에 따른 치료 결과의 비교)

  • Heo, Youn Moo;Kim, Tae Gyun;Song, Jae Hwang;Jang, Min Gu;Lee, Seok Won
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.51-60
    • /
    • 2021
  • Purpose: Radiocarpal dislocation (RCD), which is caused by high-energy trauma, often involves radial styloid fractures and short radiolunate ligament (SRLL) injuries. Although SRLL injuries may occur as a simple rupture at the attachment site of radius, it may occur with a relatively large avulsed-fragment in the volar rim of the lunate facet of the radius. This study aimed to differentiate the injury type of SRLL and assess the differences in the treatment results depending on the treatment methods that have been applied in RCD with radial styloid fractures. Materials and Methods: Eighteen patients managed surgically with RCD were enrolled in this study. The patients were classified as Group 1 and Group 2 by using the Dumontier method. In this study, Group 2 was subdivided into 2A (purely ligamentous or small avulsion fracture of the volar rim of lunate facet) and 2B (large avulsed-fragment enough to internal fixation) according to the injury type of SRLL. Groups 2A and 2B were treated with direct repair and screw fixation, respectively. Pain, range of motion of the wrist joint, grip strength, and complications on final radiographs were examined. The outcomes were evaluated using patient-rated wrist evaluation (PRWE), and modified Mayo wrist score (MMWS). Results: All patients were Group 2 (six and twelve patients in 2A and 2B, respectively). The mean flexion to extension arch recovered 79%,and the mean grip strength was 72.9% of the uninjured side. Group 2A showed better recovery in extension, flexion and pronation than Group 2B, but there was no difference in radial deviation, ulnar deviation, supination, grip strength and pain. No differences in the PRWE and MMWS were observed between two groups. Complications included traumatic arthritis in seven patients and residual instability in five patients. Conclusion: When the SRLL was injured, the involvement of a large avulsion fracture on the anterior plane of the radiolunate did not affect the test results. On the other hand, it should be observed cautiously because avulsion fractures tend to disturb the joint's reduction through rotation or displacement. In addition, anatomical reduction and sturdy internal fixation are important for restoring the function of the SRLL.

Arm Morbidity after Breast Cancer Treatments and Analysis of Related Factors (유방암 환자의 상지 부작용과 관련 요인)

  • Chun Mi Son;Moon Seong Mi;Lee hye Jin;Lee Eun-Hyun;Song Yeoung Suk;Chung Yong Sik;Park Hee Bung;Kang Seung Hee
    • Radiation Oncology Journal
    • /
    • v.23 no.1
    • /
    • pp.32-42
    • /
    • 2005
  • Purpose : To evaluate the incidence of arm morbidity following breast cancer surgery including axillary dissection and to identify related factors. Materials and Methods : One hundred and fifty nine patients were studied using a self-report questionnaire and a clinical examination. Lymphedema, reduction of range of motion in shoulder joint and subjective symptoms (pain, impaired arm movement, numbness, stiffness) were evaluated. As related factors, demographic, oncologic characteristics and types of treatment were analysed. Results : The incidence of lymphedema ($\geqq$2 cm difference comparing to unaffected arm) was $6.3\%$, $10.7\%$, $22.5\%$ and $23.3\%$ at each 10 cm, 20 cm, 30 cm, and 40 cm from wrist. Reduction of range of motion in shoulder joint ($\geqq$ 20 degree difference comparing to unaffected arm) was noted In more than 1/3 patients for flexion, abduction and internal rotation. Especially the reduction of range of motion in internal rotation was severe ($>50\%$ reduction) in 1/3 patients. Approximately 50 to $60\%$ of patients complained impaired arm movement, numbness, stiffness and pain. Body mass index (BMI) was the significant risk factor for lymphedema. Conclusion : Lymphedema was present in 1/3 of patients and the common sites of edema were 30 cm 40 cm proximal from the wrist. Also most severe reduction of range of motion in shoulder joint was with internal rotation. There needs weight control for lymphedema because BMI was the significant risk factor for lymphedema. Also rehabilitation program for range of motion especially internal rotation In shoulder joint should be developed.

The Kinematic Analysis of the Pitching motion for the Straight and Curve ball (직구와 커브 투구동작의 운동학적 비교 분석)

  • Lee, Young-Jun;Kim, Jung-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.109-130
    • /
    • 2002
  • The purpose of this paper was to make a comparative analysis for the difference of the various kinematic variation which is occurred in the each situation when pitchers throw a straight and a curve ball. Four pitchers, who are two national team players and two high level pitchers, were selected among the right over hand pitchers of D university in the Busan for this paper. The data were analyzed by using 3D equipment. The results of the analysis which was about the elapsed time of the pitching, the movement of the body center-point, the highest height of the left knee, stride length, knee joint angle, shoulder joint angle, elbow joint angle and wrist joint angle in the each section(ST, LKU, HBP, LCF, MCP, BRP) were as follows : 1. Pitching time in the each section and step in the pitching for straight and curve ball was similar. The total elapsed time of the straight and curve ball was 1.78${\pm}$0.07sec and 1.77${\pm}$0.11sec in the order. 2. The position change of the body center to the Z(above below) direction did not show significant difference in the each situation of the section and step between pitching for the straight and curve ball. 3. Height of the left knee did not show significant difference as 125.38${\pm}$11.85cm and 124.95${\pm}$11.63m in the each pitching motion for straight and curve ball. The rate(%H) between height and stride length showed 68.42${\pm}$5.53(%H), 68.40${\pm}$5.45(%H) in the each pitching motion. 4. Pitching for curve ball showed longer stride length than pitching for straight ball that as the stride length was 140.35${\pm}$4.96cm and 144.8${\pm}$1.69cm. The rate(%H) between height and stride length showed 76.9${\pm}$3.77(%H), 79.39${\pm}$2.23(%H) in the each pitching motion. 5. Left knee joint angle did not show significant difference in the ST, LKU and HBP section in the each pitching motion. However, it was shown that knee joint angle was flexed much more in the LFC, MCP and BRP section in the pitching for curve ball. 6. Right shoulder joint angle did not show significant difference in the ST, LKU and HSP section. However, when pitches threw a curve ball in the LKU section. In the LFC section, the right shoulder joint angle was extended much more in the pitching for curve ball, and the angle was extended much in the MCP and BRP section in the pitching for curve ball than straight ball. 7. Right elbow joint angle did not show significant difference in the ST, LKU and HRP section in the two pitching motion. The angle had more flexion in the LFC and MCP section in the pitching for curve ball than the pitching for straight ball. The angle in the each pitching motion for straight ball and curve ball were extended by a narrow margin in the BRP section. 8. Right wrist joint angle was extended much more in the LFC and MCP section in the pitching for curve ball. In the BRP section, the angle was extended much more in the pitching for straight ball than curve ball.

Long-Term Result of the Epiphyseal Transplantation in Distal Forearm (전완원위부 변형에 대한 혈관부착 성장판 이식술)

  • Chung, Duke-Whan;Han, Chung-Soo;Yoo, Myung-Chul;Han, Soo-Hong
    • Archives of Reconstructive Microsurgery
    • /
    • v.4 no.1
    • /
    • pp.16-22
    • /
    • 1995
  • We analyzed 11 children who underwent epiphyseal transplantation to the forearm for manage growing deformity ranged from 2 years 6 months to years(average 5 years 10 months) follow-up period. Etiologies of the functional impairment of the eleven were five traumatic, three congenital and three tumorous conditions. Lesions of epiphysis were distal radius in eight patients and distal ulna in three patients. Operation was performed with removal of non-functioning or deformed epiphysis followed by transplantation of free vascularized proximal fibular epiphysis with microvascular anastomesis. Evaluation was performed radiologically and functionally. The 9(81.8%) patients showed growth of transplanted epiphysis by radiological examination during follow up. At the last follow up, average growth rate was 0.86cm per year excepts 2 cases of no growth. Active wrist motion near normal to contralateral joint was achieved in 7 patients. In other 2 patients, active joint motion was improved but weaker than contralateral joint. Complications on donor site were two transient peroneal nerve palsy which have been resolved after 2 and 5 months post operation and one valgus ankle deformity. The ankle deformity was corrected with $Langenski\"{o}ld$ operation of the dital tibiofibular fusion. At recipient site, there was one superficial infection and it was easily controlled by systemic antibiotics. Many subsequent reports have described successful nonvascularized epiphyseal transplante, but overall results have been inconsistent and unsatisfactory. Other experimental and clinical studies in the transfer of vascularized epiphyses has encourage its clinical application. We also could gel successful growth in several cases with free vascularized epiphyseal transplantation.

  • PDF

Changes of Walking Pattern for Young Adults dur ing Level Walking under Low Illumination (20대 남성의 낮은 조도의 평지 보행 시 보행 패턴 변화)

  • Choi, Jin-Seung;Kang, Dong-Won;Bang, Yun-Hwan;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.4
    • /
    • pp.381-386
    • /
    • 2010
  • This study examined the changes in the walking pattern during level walking under low illumination conditions. Fourteen male subjects ($22.1{\pm}2.21$ years, $174{\pm}3.74\;cm$, $68.86{\pm}10.81\;kg$) with normal vision and no disabilities were enrolled in this study. All experiments were performed on a level walkway with three conditions: normal walking (preferred & low speed) and walking with low illumination. 3D motion capturing system was used for acquisition and analysis of the walking motion data with a sampling frequency of 120Hz. The walking speed, normalized jerk(NJ) at the center of mass(COM), wrist and heel, knee and elbow joint angle, ratio of the knee joint angle to elbow joint angle and the toe clearance on stance phase were used to compare the differences in walking pattern between the two illumination conditions, The results showed that the walking speed and joint angles decreased in low illumination, whereas the NJ and toe minimum clearance increased. In low illumination, most variables were similar to effects of low speed walking, but toe clearance was different from the effects of low speed. These results can be used as primary data for examining the changes in the level walking pattern of young adults under low illumination. Further study will be needed to compare these results in young adults with those in the elderly.

Effect of Electrical Stimulation on Upper Extremity Function in Stroke Patients: A Systematic Review Based on Randomized Controlled Trials (뇌졸중 환자의 상지 기능에 기능적 전기 자극이 미치는 영향: 무작위대조군연구에 기초한 체계적 고찰)

  • Hwang, Su-jin;Seo, Yeon-ju
    • PNF and Movement
    • /
    • v.20 no.2
    • /
    • pp.147-156
    • /
    • 2022
  • Objective: Electrical stimulation is an assistive technology used to aid the recovery of upper limb use after stroke. The purpose of this systematic review was to determine the effects of electrical stimulation on upper extremity function in individuals with hemiparetic stroke and to develop an evidence base that supports the use of electrical stimulation for upper limb recovery after stroke. Design: A systematic review based on randomized controlled trials (RCTs). Methods: Studies published before April 20 2021 were collected for this review by searching PubMed, four other databases, and RCTs that reported the effects of electrical stimulation on upper extremity function in individuals with the characteristic stroke type. Information on the following parameters was extracted from each study: surname of first author, published year, country, participants, intervention, intervention's intensity, comparison, outcomes, additional therapy, and summary of results. This review also evaluated the bias within each study, including any selection bias, performance bias, detection bias, attrition bias, and reporting bias. Results: This review included five RCTs, and 208 stroke patients were included in the analysis. Stroke patients who underwent electrical stimulation showed significantly improved grip and pinch strengths, wrist range of motion, and basic daily living compared to those in the control group; however, there was no improvement in upper extremity function. Of the selected papers, 60% showed a "high risk" of performance bias, and 20% showed a "high risk" of detection bias. Conclusions: The results of this systematic review suggest that electrical stimulation provides some benefits to stroke patients, such as improved hand strength and range of motion. However, future studies are needed to provide clinical evidence of the effects of electrical stimulation on upper extremity function in stroke patients.

Effects on Mechanical Properties, Joint Range of Motion, and Grip Strength of Forearm Muscles Depending on Wrapping Direction of the Floss Band

  • Ki Bum Jung;Seohui Kim;Yongwoo Lee
    • Physical Therapy Rehabilitation Science
    • /
    • v.13 no.1
    • /
    • pp.95-105
    • /
    • 2024
  • Objective: The purpose was to investigate changes in mechanical properties, range of motion, and grip strength of the forearm muscle in 13 students depending on the wrapping direction of the floss band. Design: A single-blind, crossover study Methods: Subjects were randomly assigned to the wrapping direction of the flossing band and then performed a concentric exercise of the wrist flexors using a Flex-Bar. Intervention A applied the flossing band in a right spiral direction, Intervention B applied the flossing band in a left spiral direction, and Intervention C performed the exercise alone. All subjects used their dominant right hand, and pre- and post-assessments were conducted between interventions. To analyze differences in changes between groups pre- and post-, all results were subjected to one-way ANOVA, followed by Scheffe's test as a post-hoc analysis. The paired samples t-test was used to analyze the difference between pre- and post-change within groups. Results: First, in the mechanical properties of the Flexor carpi ulnaris (FCU) muscle, interventions A and B significantly improved muscle tone and stiffness than intervention C (p<0.05), and intervention A showed a significant decrease in decrement (muscle elasticity) than intervention B (p<0.05). Second, interventions A and B showed significant improvement in grip strength than intervention C (p<0.05). Conclusions: The right spiral direction of the flossing band tended to increase the elasticity of the muscles compared to the left spiral direction. Therefore, in future studies, it is necessary to choose the direction of the flossing band to increase the elasticity of the muscles.

A Simple Control Method for Opening a Door with Mobile Manipulator

  • Kang, Ju-Hyun;Hwang, Chang-Soon;Park, Gwi-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1593-1597
    • /
    • 2003
  • The home service robot supports human beings by performing various kinds of works at home. This paper presents a simple control method for opening a door from the viewpoint of the mobile manipulation. The simulation shows various results of path planning and motion planning for opening a door. The joint trajectories were generated by the simulation system. In general, a six-axis force/torque sensor at an end-effector is needed in order to maintain the static equilibrium of the manipulator. But we show another method. From three components of applied forces which was directly obtained by the three-axis force sensor and three components of applied forces which was indirectly estimated by the joint-torque sensors, all of joint torques that will exactly balance forces at the end-effector in the static situation can be found. It is more practical method than using a six-axis force sensor in a wrist. Experimental results have shown that the opening a door can be realized more effectively from the suggested control method of mobile manipulation.

  • PDF

Measurement of Arterial Pulse Wave at the Temple Using PZT Piezo Sensor

  • Kil Se Kee;Han Young Hwan;Lee Eung Hyuk;Park Young Bae;Cho Heung Ho;Min Hong Ki;Hong Seung Hong
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.772-775
    • /
    • 2004
  • Generally, arterial pulse waves are measured at the radial arterial of wrist or carotid arterial of neck using a sensor such as pressure sensor, piezoelectric sensor or optic sensor. But in this paper, arterial pulse wave is measured at the temple using PZT piezo sensor which is attached on the temple in form of a hair-band. Arterial Pulse waves are generally measured when a reagent is in a static state. But in this paper, we implemented the arterial pulse wave measurement system, as a previous stage of the arterial pulse wave measurement system for running at outdoors or on a running machine, that measures arterial pulse waves at the temple, which is the least moving part when running. Thorough the continuous study, if the motion artifact when running is possible to be removed, the system will be able to perform monitoring of running men's states and especially emergency signals such as serious pulse waves of an/old and feeble persons and handicapped persons.

  • PDF

Kinematic Analysis of Service Movement In Each Position of Soft Tennis (포지션별 정구 플랫서비스의 운동학적분석)

  • Kim, Hun-Soo
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.1
    • /
    • pp.221-231
    • /
    • 2002
  • The purpose of this study was to clarify the differences in service patterns of a forward and backward soft tennis players using 3D motion analyzer. Subjects were 4 forward players of $24.0\pm5.23$yrs and 4 backward players of $23.5\pm1.73$yrs. The results were as following: 1. There was no difference among each positions on swinging-time. The longest racket swinging-time was in the phase of takeback, the second one was in follow-through. The shortest one was in the phase of forward-swing so called force production phase, which had an influence on ball's velocity. 2. The racket speed on impact was 16.3m/s in forward subject and 19.53m/s in backward subject, when each velocity of balls was 44.6m/s, 52.9m/s. Although there was no significant difference along by positions, backward subject showed faster result. 3. The maximum speed of each performance was reached before the impact, and the speed at impact along by positions did not show any significant difference. The summation of velocity was measured in good order as following; hip, shoulder, elbow, wrist, top of racket. 4. In the angular velocity of all examine except one, the angular velocity of forearm was bigger than the one of racket top although there was no statistically significant difference between forward and backward subject. 5. The service grip of the forward players was shorter than that of backward players.