Transmission Characteristics on Wire-Driven Links of a Bridge Transported Servo Manipulator for the ACP Equipment Maintenance (사용후핵연료 차세대관리 공정장치 유지보수용 천정이동 서보 매니퓰레이터 와이어 구동부 동작특성)

  • 박병석;진재현;송태길;김성현;윤지섭
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.3
    • /
    • pp.189-199
    • /
    • 2004
  • A bridge transported servo manipulator (BTSM) system for the advanced spent fuel conditioning process (ACP) has been developed to overcome the limitation of access, which is a drawback of mechanical master-slave manipulators (MSM) for the equipment maintenance. The servo manipulator is composed of a slave manipulator attached to the telescoping tubesets equipped with the overhead bridge installed at a hot cell and a master manipulator installed at an out-of-hot cell. Each manipulator has 7 degrees-of-freedom (DOF): a body rotation, an upper-arm tilt, a lower-arm tilt, a lower-arm rotation, a wrist pan & tilt, and a grasp motion. A wire-driven mechanism for a lower-arm rotation, a wrist pan and tilt, and a grasp motion of the manipulator has been adopted to increase the handling capacity compared to the manipulator weight and decrease the friction. The main disadvantage of the wire-driven mechanism is that if one link is in motion, other links can be affected. In this paper, the transmission characteristics among the wire-driven links have been formulated to overcome this drawback. The unexpected behaviors are confirmed by analyses of transmission characteristics as well as experiments. Also, the experimental results show that the unexpected behaviors are greatly decreased by the proposed compensation equations.

  • PDF

Effect of posture correction training in dental scaling using rapid upper limb assessment and 3D motion analysis (Rapid upper limb assessment와 3차원 동작 분석을 활용한 치석제거 자세교정 교육의 효과)

  • Yoon, Tae-Lim;Min, Ji-Hyun;Kim, Han-Na
    • Journal of Korean society of Dental Hygiene
    • /
    • v.18 no.3
    • /
    • pp.269-280
    • /
    • 2018
  • Objectives: The purpose of this study was to investigate the change in the posture of dental hygiene students and clinical dental hygienists when implementing dental scaling before and after posture correction training using the rapid upper limb assessment (RULA) method and 3D motion analysis. Methods: Thirty-two healthy volunteers performed dental scaling to remove artificial calculus on dental manikin. The movement and angle of the joints were verified by RULA and 3D motion analysis during the procedure. The subjects were also photographed for 1 minute during the procedure for 10 minutes while the calculus was removed. After the removal of the calculus, the subject and the instructor checked the video together. Posture correction training was conducted by the instructor so that the subject could perform the calculus removal operation in the correct posture. Artificial calculus of the adjacent teeth was then removed for the same period of time, and the change in posture was reviewed. Results: The total score of the posture change using RULA was $5.72{\pm}0.58$ before training and $4.31{\pm}0.10$ after training, showing a significant decrease after training (p<0.001), and upper arm, lower arm, wrist position, neck and waist position showed significant decrease after training. The three-dimensional motion analysis showed significant differences according to the criteria measured at all measurement sites except the left shoulder (p<0.05) Conclusions: It was confirmed through RULA and 3D motion analysis that postural correction training using calculus removal images was effective, and that correct postural education is essential to preventing musculoskeletal diseases caused by removal of calculus.

Effects of Passive Upper Arm Exercise on Range of Motion, Muscle Strength, and Muscle Spasticity in Hemiplegic Patients with Cerebral Vascular Disease (입원초기에 적용된 상지수동운동이 뇌혈관질환자의 환측 관절가동범위, 근력 및 상지 경직에 미치는 효과)

  • Shin, Dong Soon;Song, Rhayun;Shin, Eun Kyung;Seo, Sung Ju;Park, Jeong Eun;Han, Seung Yeon;Jung, Hoi Yong;Ryu, Choon Ji
    • Journal of Korean Academy of Nursing
    • /
    • v.42 no.6
    • /
    • pp.783-790
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the effects of passive upper arm exercise on range of motion, muscle strength, and muscle spasticity in hemiplegic patients with cerebral vascular disease. Methods: A quasi-experimental design with nonequivalent control group was utilized. According to inclusion criteria, 25 patients were assigned to the control group with routine care, followed by 25 to the intervention group with passive exercise for 30 minutes per session, twice a day for 2 weeks. Eighteen patients in the intervention group and 17 in the control group completed the posttest measurement, including range of motion for upper arm joints, manual muscle test, and Modified Ashworth Scale for muscle spasticity. Results: The intervention group had a significantly improved range of motion in the shoulder and wrist joints. No interaction effect was found for the elbow joint. No significant differences were found in muscle strength or muscle spasticity between the groups. Conclusion: Results of the study indicate that passive exercise safely applied for two weeks improves range of motion in joints of the upper arm in these patients. Further study with long-term follow-up is needed to verify the role of passive exercise in preventing muscle spasticity in this population.

Redundant Design of Wearable Robot Mechanism for Upper Arm (여자유도를 이용한 상지 착용형 로봇의 메커니즘 설계)

  • Lee, Young-Su;Hong, Sung-Jun;Jang, Hye-Yeon;Jang, Jae-Ho;Han, Chang-Su;Han, Jung-Su
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.7
    • /
    • pp.134-141
    • /
    • 2009
  • Recently, many researchers have tried to develop wearable robots for various fields such as medical and military purposes. We have been studying robotic exoskeletons to assist the motion of persons who have problems with their muscle function in daily activities and rehabilitation. The upper-limb motions (shoulder, elbow and wrist motion) are especially important for such persons to perform daily activities. Generally for shoulder motion 300F is needed to describe its motion(extension/flexion, abduction/adduction, internal/external rotation) but we have used a redundant actuator thus making a 4 DOF system. In this paper, we proposed the mechanism design of the exoskeleton which consists of 4-DOF for shoulder and 1-DOF for elbow robotic exoskeleton to assist upper-limb motion. Then we compared the new mechanism design and prototype mechanism design. Here we also analyze the proposed system kinematically to find out and to avoid the singular point. This research will ensure that the proposed wearable robot system make human's motion more powerfully and more easily.

Light Modulation based on PPG Signal Processing for Biomedical Signal Monitoring Device (생체 정보 감시 장치를 위한 광변조 기법의 PPG 신호처리)

  • Lee, Han-Wook;Lee, Ju-Won;Jeong, Won-Geun;Kim, Seong-Hoo;Lee, Gun-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.503-509
    • /
    • 2009
  • The development of technology has led to ubiquitous health care service, which enables many patients to receive medical services anytime and anywhere. For the ubiquitous health care environment, real-time measurement of biomedical signals is very important, and the medical instruments must be small and portable or wearable. So, such devices have been developed to measure biomedical signals. In this study, we develop the biomedical monitoring device which is sensing the PPG signal, one of the useful signal in the field of ubiquitous healthcare. We design a watch-like biomedical signal monitoring system without a finger probe to prevent the user's inconvenience. This system obtains the PPG from the radial artery using a sensor in the wrist band. But, new device developed in this paper is easy to get the motion artifacts. So, we proposed new algorithm removing the motion artifacts from the PPG signal. The method detects motion artifacts by changing the degree of brightness of the light source. If the brightness of the light source is reduced, the PPG pulses will disappear. When the PPG pulses have disappeared completely, the remaining signal is not the signal that results from the changing blood flow. We believe that this signal is the motion artifact and call it the noise reference signal. The motion artifacts are removed by subtracting the noise reference signal from the input signal. We apply this algorithm to the system, so we can stabilize the biomedical monitoring system we designed.

Mechanical Analysis of throw motion in Bowling (볼링투구동작의 운동역학적 분석(II))

  • Lee, Kyung-Il
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.1
    • /
    • pp.173-191
    • /
    • 2002
  • The purpose of this study was defined efficient throw motion pattern to obtain the quantitative data and to achieve successful bowling through kinetic - kinematic variables on the throw motion. Subject of group composed of three groups : Higher bowlers who are two representative bowlers with 200 average points and one pro-bowler. Middle bowlers who are three common persons with 170 average points. Lower bowler who are three common persons with 150 average points. Motion analysis on throw motion in three groups respectively has been made through three-dimension cinematography using DLT method. Two high-speed video camera at operating 180 frame per secondary. One-way ANOVA has been used to define variable relations. Analyzed result and conclusion are the following : The displacement of back of the hand must have wider difference of each right-left displacement to increase the spin of the ball. In high bowlers group, difference between the front-rear position of back of the hand in case of success and that in case of failure in follow throw is 0.17m. That is to say, momentum in case of success come to increase greatly, compared with that in case of failure. To increase the spin of the ball, the potential difference should be narrower in follow through. In case of the high bowlers, the velocity of the front-rear direction of the back of the hand has been the fastest both in release and follow through, compared with those in other groups, which has contributed to increasing the spin force of the ball. The orders in the resultant velocity of the back of the hand has shown the this : the finger tip$\rightarrow$the back of the hand$\rightarrow$wrist.These orders made the proximal segment support the distal segment. The distal segment has provided the condition to accelerate the velocity. In case of failure, the suddenly increased velocity has caused the failure in the follow through. Acutely flexing the angle of the back of the hand has contributed to lifting to increase the spin of the ball.

The ergonomic analysis on dental hygienists' scaling treatment posture based on two dimensional motion (치과위생사 스켈링 시술자세의 2D에 의한 인간공학적 분석)

  • Jung, You-Sun
    • Journal of Korean society of Dental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.73-87
    • /
    • 2003
  • This study was performed on 17 female dental hygienists to find an appropriate method to reduce the hygienists' body discomfort while scaling, and provide a foundation to educate them how 10 posture during the process. To assess the arm abduction, elbow flexion, neck flexion, trunk flexion and trunk lateral bending through Video 2D(two dimensional motion) analysis and assessing the risk through the Action level of RULA(rapid upper limb assessment) checklist, an ergonomic analysis method. Correlation analyses on the posture angles and on body discomfort were performed. ANOVA analysis on scaling treatment position and the scaling treatment region of patients was also performed. The results are as following. 1. 20 analysis while scaling, arm abduction was $40{\sim}79.9^{\circ}$, elbow flexion $20{\sim}110^{\circ}$, neck flexion $50{\sim}100^{\circ}$, trunk flexion $60{\sim}80^{\circ}$, and trunk lateral bending $5{\sim}19.9^{\circ}$. 2. The Action level of RULA was 2. 3 resulted from scores 4 and 5 of group A which includes upper arm, lower ann, wrist, and scores 2 and 4 of group B which includes neck, trunk, legs. It means that the scaling treatment posture causes a high incidence rate of musculoskeletal that an additional investigation and improvement should be followed without hesitation. 3. There were significant differences among the maxilla right, maxilla anterior, maxilla left, mandible left, mandible anterior, and mandible right of a patient of the right and left upper arm, lower arm, neck, trunk, group A, group B, final RULA score while scaling treatment. 4. There were significant differences among the time position of 8, 9, 10, 11, 12, 13 of the right and left upper arm, lower arm, neck, trunk, group A, group B, final RULA score while scaling treatment, 5. As for the body discomfort, neck, right shoulder, left shoulder, right back, right wrist etc. were listed on top. As a conclusion, performing the time position of 12 which shows low right and left final RULA scores is better than the time position of 8 and 10 which show high final RULA scores to reduce the body discomfort while scaling treatment.

  • PDF

Design of A Portable Device for Measuring Heart Rate Using Harmonic Signal and Adaptive Filter (하모닉 신호와 적응 필터를 이용한 휴대형 심박수 측정 장치 설계)

  • Lee, Ju-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.3
    • /
    • pp.723-728
    • /
    • 2010
  • This study proposed a design of a portable device for measuring heart rate using photoplethysmograph signal to minimize load of a nurse increased from insufficiency of an internal hospital nurse, and algorithm to measure reliable heart rate in PPG signals despite the existence of patient's motion artifacts. The proposed method for measuring heart rate is the method to minimize the motion interference by using the adaptive filter based on harmonic characteristic of PPG signal. To evaluate the performances of the a portable device implemented by the proposed method, we used several motion artifacts including finger and wrist movements; we then compared out results with the performance of the moving average filter. In this results, the proposed method showed a better performance than that of the moving average filter. Therefore, when nurses use the a portable device for measuring heart rate proposed in this study, it will enable to improve nurse work and to measure the reliable heart rate.

Kinematical Analysis on the Head Hitting Motion Based on Weight Change of Bamboo Swords (죽도 무게변화에 따른 검도 머리치기 동작의 운동학적 분석)

  • Chung, Nam-Ju;Kim, Jae-Pil;Ku, Jong-Mo
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • This study was performed to investigate the kinematic factors on the head hitting motion based on weight change of bamboo swords in kumdo. The kinematic factors, needed time per phase, COB displacement and velocity, angle(wrist, elbow, shoulder joint, hip joint, knee joint), were analyzed by the 3-D motion analysis method against 6 male middle school athletes. The results were as follows. 1. The needed time of head hitting motion based on weight change of bamboo swords was shorter when weight was heavier. 2. The COB displacement of left/right was bigger when weight was heavier. the displacement of right foot was higher at backswing phase and impact phase when weight was heavier and at impact time when weight was lighter. 3. The COB velocity was faster at impact time when weight was heavier, the velocity of sword tip was fastest for each event with bamboo sword weight of 440 g. 4. The angle of left elbow was smaller at top of backswing and impact when weight was heavier, the angle of left shoulder was bigger when weight was heavier, the right knee angle was biger at start when weight was heavier, at impact when weight was lighter.

Technical Development of Interactive Game Interface Using Multi-Channel EMG Signal (다채널 근전도 신호를 이용한 체감형 게임 인터페이스 개발)

  • Kim, Kang-Soo;Han, Yong-Hee;Jung, Won-Beom;Lee, Young-Ho;Kang, Jung-Hoon;Choi, Heung-Ho;Mun, Chi-Woong
    • Journal of Korea Game Society
    • /
    • v.10 no.5
    • /
    • pp.65-73
    • /
    • 2010
  • In this paper, we developed the device for an interactive game interface using bio signals which were able to recognize user's motion intention using EMG signals and it was applied to the games which need the information of the muscle motion directions. The module for acquiring EMG signals consists of 4-Ch, wrist-motions were defined as up, right, down and left state. The user's intent was recognized through thresholding and comparing signals of each channel. The classification result of the motion directions could control the arrow keys on the keyboard of PC and it was applied on the various games. This proposed game device can be expected to induce an effective exercise with an interesting and enjoyment, and it can use both self-developed or commercial games.