• Title/Summary/Keyword: Worst scenario

Search Result 105, Processing Time 0.021 seconds

A Sensitivity Study of a Steam Generator Tube Rupture for the SMART-P (SMART 연구로의 증기발생기 전열관 파열사고 민감도 분석)

  • Kim Hee-Kyung;Chung Young-Jong;Yang Soo-Hyung;Kim Hee-Cheol;Zee Sung Quun
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.2 s.70
    • /
    • pp.32-37
    • /
    • 2005
  • The purpose of this study is for the sensitivity study f9r a Steam Generator Tube Rupture (SGTR) of the System-integrated Modular Advanced ReacTor for a Pilot (SMART-P) plant. The thermal hydraulic analysis of a SGIR for the Limiting Conditions for Operation (LCO) is performed using TASS/SMR code. The TASS/SMR code can calculate the core power, pressure, flow, temperature and other values of the primary and secondary system for the various initiating conditions. The major concern of this sensitivity study is not the minimum Critical Heat Flux Ratio(CHFR) but the maximum leakage amount from the primary to secondary sides at the steam generator. Therefore the break area causing the maximum accumulated break flow is researched for this reason. In the case of a SGIR for the SMART-p, the total integrated break flow is 11,740kg in the worst case scenario, the minimum CHFR is maintained at Over 1.3 and the hottest fuel rod temperature is below 606"I during the transient. It means that the integrity of the fuel rod is guaranteed. The reactor coolant system and the secondary system pressures are maintained below 18.7MPa, which is system design pressure.

Health Risk Assessment by Potential Exposure of NO2 and VOCs in Apartments (공동주택내 이산화질소(NO2) 및 휘발성유기화합물(VOCs) 노출에 따른 건강 위해성 평가)

  • Jung, Soon-Won;Yang, Won-Ho;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.4
    • /
    • pp.242-249
    • /
    • 2007
  • Indoor air quality has become a topic of interest and concern. Especially changes in construction design and the increased use of synthetic products may result in an increasing of complaints and health effects about the quality of indoor air at home. In this study, nitrogen dioxide($NO_2$) and volatile organic compounds(VOCs) within new and established apartments on the basis of 4 years of building year were measured every 3 days consecutively during 60 days. We selected each 10 house in Seoul, Asan and Daegu, respectively, and produced risk numbers for hazard quotients, and predicted increases in incidence of cancer. The calculations were made for the adult with default exposure values and also made for a worst case scenario using Monte-Carlo simulation as describing the reasonable exposure(RME). Mean of Monte carlo analysis by benzene, in the construction under 4 years (male: $9.2{\times}10^{-5}$, female: $1.0{\times}10^{-4}$) and over 4 years (male: $6.8{\times}10^{-5}$, female: $8.3{\times}10^{-5}$) exceeded $10^{-6}$ of permitted standards in US EPA, RME of Monte carlo analysis. In construction under 4 yews (male: $9.9{\times}10^{-3}$, female: $9.6{\times}10^{-3}$) and over 4 years (male: $9.8{\times}10^{-3}$, female: $7.8{\times}10^{-3}$) exceeded $10^{-4}$ of maximum permitted standards in US EPA. The hazard index of non-carcinogenic pollutants by nitrogen dioxide, toluene, m,p-xylene and o-xylene, both male and female in apartment constructed under 4 yews and over 4 years was found less than the permitted standards of hazardous health effects in CTE. Significant cancer risks and non-cancer hazard quotients were predicted in under 4 yews of building year.

Permitted Daily Exposure for Diisopropyl Ether as a Residual Solvent in Pharmaceuticals

  • Romanelli, Luca;Evandri, Maria Grazia
    • Toxicological Research
    • /
    • v.34 no.2
    • /
    • pp.111-125
    • /
    • 2018
  • Solvents can be used in the manufacture of medicinal products provided their residual levels in the final product comply with the acceptable limits based on safety data. At worldwide level, these limits are set by the "Guideline Q3C (R6) on impurities: guideline for residual solvents" issued by the ICH. Diisopropyl ether (DIPE) is a widely used solvent but the possibility of using it in the pharmaceutical manufacture is uncertain because the ICH Q3C guideline includes it in the group of solvents for which "no adequate toxicological data on which to base a Permitted Daily Exposure (PDE) was found". We performed a risk assessment of DIPE based on available toxicological data, after carefully assessing their reliability using the Klimisch score approach. We found sufficiently reliable studies investigating subchronic, developmental, neurological toxicity and carcinogenicity in rats and genotoxicity in vitro. Recent studies also investigated a wide array of toxic effects of gasoline/DIPE mixtures as compared to gasoline alone, thus allowing identifying the effects of DIPE itself. These data allowed a comprehensive toxicological evaluation of DIPE. The main target organs of DIPE toxicity were liver and kidney. DIPE was not teratogen and had no genotoxic effects, either in vitro or in vivo. However, it appeared to increase the number of malignant tumors in rats. Therefore, DIPE could be considered as a non-genotoxic animal carcinogen and a PDE of 0.98 mg/day was calculated based on the lowest No Observed Effect Level (NOEL) value of $356mg/m^3$ (corresponding to 49 mg/kg/day) for maternal toxicity in developmental rat toxicity study. In a worst-case scenario, using an exceedingly high daily dose of 10 g/day, allowed DIPE concentration in pharmaceutical substances would be 98 ppm, which is in the range of concentration limits for ICH Q3C guideline class 2 solvents. This result might be considered for regulatory decisions.

Establishment of Korean Environmental Sensitivity Index Map (ESI Map 구축 연구)

  • Sung H. G.;Lee H. J.;Lee M. J.;Kang C. G.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.6 no.4
    • /
    • pp.3-12
    • /
    • 2003
  • Due to the high demand on energy resources accompanied by continuing industrialization and urbanization, the world marine transportation of crude and product oils is being gradually increased. In Korea, we are exposed to the large-scale marine oil spill accidents because a very large oil tanker of 300,000 tonnage must enter Korean Ports every day to meet the domestic demand on oils. Although we are exerting our strength to reduce the probability of marine oil pollution accidents, a unrestorable oil spill is to occur owing to human errors, severe weather conditions, or combined causes. Thus, area contingency plan equipped with appropriate management system for response and restoration for the worst case discharge scenario must be entirely prepared to protect mine environments and coastal resources. In particular, we are focusing on the Environmental Sensitivity Index Map(ESI Map) to reduce the environmental consequences of both spills and clean-up efforts by specifying protection Priorities in advance and identifying in-situ response strategies. In this paper, Korean ESI Map is introduced with brief definition of sensitivity to oiling and main features of the software developed hitherto.

  • PDF

Energy Balance and Power Performance Analysis for Satellite in Low Earth Orbit

  • Jang, Sung-Soo;Kim, Sung-Hoon;Lee, Sang-Ryool;Choi, Jae-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.3
    • /
    • pp.253-262
    • /
    • 2010
  • The electrical power system (EPS) of Korean satellites in low-earth-orbit is designed to achieve energy balance based on a one-orbit mission scenario. This means that the battery has to be fully charged at the end of a one-orbit mission. To provide the maximum solar array (SA) power generation, the peak power tracking (PPT) method has been developed for a spacecraft power system. The PPT is operated by a software algorithm, which tracks the peak power of the SA and ensures the battery is fully charged in one orbit. The EPS should be designed to avoid the stress of electronics in order to handle the main bus power from the SA power. This paper summarizes the results of energy balance to achieve optimal power sizing and the actual trend analysis of EPS performance in orbit. It describes the results of required power for the satellite operation in the worst power conditions at the end-of-life, the methods and input data used in the energy balance, and the case study of energy balance analyses for the normal operation in orbit. Both 10:35 AM and 10:50 AM crossing times are considered, so the power performance in each case is analyzed with the satellite roll maneuver according to the payload operation concept. In addition, the data transmission to the Korea Ground Station during eclipse is investigated at the local-time-ascending-node of 11:00 AM to assess the greatest battery depth-of-discharge in normal operation.

A Study on the Damage Range of Chemical Leakage in Polysilicon Manufacturing Process (폴리실리콘 제조 공정에서 화학물질 누출 시 피해범위에 관한 연구)

  • Woo, Jongwoon;Shin, Changsub
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.55-62
    • /
    • 2018
  • There is growing interest in solar power generation due to global warming. As a result, demand for polysilicon, which is the core material for solar cells, is increasing day by day. As the market grows, large and small accidents occurred in the production process. In 2013, hydrochloric acid leaked from the polysilicon manufacturing plant in SangJu. In 2014, a fire occurred at a polysilicon manufacturing plant in Yeosu, and in 2015, STC(Silicon Tetrachloride) leaked at a polysilicon manufacturing plant in Gunsan City. Leakage of chemicals in the polysilicon manufacturing process can affect not only the workplace but also the surrounding area. Therefore, in this study, we identified the hazardous materials used in the polysilicon manufacturing process and quantitatively estimate the amount of leakage and extent of damage when the worst case scenario is applied. As a result, the damage distance by explosion was estimated to be 726 m, and the damage distance to toxicity was estimated to be 4,500 m. And, if TCS(Trichlorosilane), STC(Silicon Tetrachloride), DCS(Dichlorosilane) leaks into the air and reacts with water to generate HCl, the damage distance is predicted to 5.7 km.

An experimental study on fire resistance of medical modular block

  • Kim, Hyung-Jun;Lee, Jae-Sung;Kim, Heung-Youl;Cho, Bong-Ho;Xi, Yunping;Kwon, Ki-Hyuck
    • Steel and Composite Structures
    • /
    • v.15 no.1
    • /
    • pp.103-130
    • /
    • 2013
  • Fire performance and fire safety of high-rise buildings have become major concerns after the disasters of World Trade Center in the U.S. in 2001 and Windsor tower in Spain in 2005. Performance based design (PBD) approaches have been considered as a better method for fire resistance design of structures because it is capable of incorporating test results of most recent fire resistance technologies. However, there is a difficulty to evaluate fireproof performance of large structures, which have multiple structural members such as columns, slabs, and walls. The difficulty is mainly due to the limitation in the testing equipment, such as size of furnace that can be used to carry out fire tests with existing criteria like ISO 834, BS 476, and KS F 2257. In the present research, a large scale calorie meter (10 MW) was used to conduct three full scale fire tests on medical modular blocks. Average fire load of 13.99 $kg/m^2$ was used in the first test. In the second test, the weighting coefficient of 3.5 (the fire load of 50 $kg/m^2$) was used to simulate the worst fire scenario. The flashover of the medical modular block occurred at 62 minutes in the first test and 12 minutes in the second test. The heat resistance capacity of the external wall, the temperatures and deformations of the structural members satisfied the requirements of fire resistance performance of 90 minutes burning period. The total heat loads and the heat values for each test are calculated by theoretical equations. The duration of burning was predicted. The predicted results were compared with the test results, and they agree quite well.

A sutdy on the District Unit Design for CO2 Reduction of Transportation (교통부문 CO2 저감을 위한 지구단위설계 방법에 관한 연구)

  • Jin, Jang-Won;Park, Min-Kwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.3
    • /
    • pp.1370-1376
    • /
    • 2012
  • This study tried to analyze $CO_2$ emission volume as green-house gases by application of land use patterns and transport policies in District Unit Design. It is postulated a Toy network and various scenarios which are combined land use patterns and transport policies for analyzing $CO_2$ gas reduction. As results, this study shows best District Unit Design technique is the policy that develop mid block and introduction of car free zone to inner 2 way streets. Worst design technique is the policy that make hierarchical network and introduction of access control to outer roads that have been known as a best road policy till nowadays. Therefore, we need more carefully introduce design technique for reduction of $CO_2$ in District Unit.

Stability Analysis of Mine Roadway Using Laboratory Tests and In-situ Rock Mass Classification (실내시험과 현장암반분류를 이용한 광산갱도의 안정성 해석)

  • Kim, Jong Woo;Kim, Min Sik;Lee, Dong Kil;Park, Chan;Jo, Young Do;Park, Sam Gyu
    • Tunnel and Underground Space
    • /
    • v.24 no.3
    • /
    • pp.212-223
    • /
    • 2014
  • In this study, the stability analyses for metal mine roadways at a great depth were performed. In-situ stress measurements using hydrofracturing, numerous laboratory tests for rock cores and GSI & RMR classifications were conducted in order to find the physical properties of both intact rock and in-situ rock mass distributed in the studied metal mine. Through the scenario analysis and probabilistic assessment on the results of rock mass classification, the in-situ ground conditions of mine roadways were divided into the best, the average and the worst cases, respectively. The roadway stabilities corresponding to the respective conditions were assessed by way of the elasto-plastic analysis. In addition, the appropriate roadway shapes and the support patterns were examined through the numerical analyses considering the blast damaged zone around roadway. It was finally shown to be necessary to reduce the radius of roadway roof curvature and/or to install the crown reinforcement in order to enhance the stability of studied mine roadways.

Quayside Mooring System Design of Prelude FLNG for Extreme Environmental Condition (극한환경조건에 대한 프릴루드 FLNG 안벽계류시스템 설계)

  • Cho, Jin-Woog;Yun, Sang-Woong;Kim, Bong-Jae;Choi, Jae-Woong;Kim, Booki;Yang, Seung-Ho
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.1
    • /
    • pp.21-27
    • /
    • 2018
  • The design and analysis of a quayside mooring system for safe mooring of Prelude FLNG under extreme environmental conditions were carried out. The design of the mooring system considered the yard operation conditions and maximum wind speed during a typhoon. In order to secure the mooring safety of Prelude FLNG under an extreme environment, a special steel structure was designed between the quay and Prelude FLNG to maintain the distance from the quay to a certain extent to avoid a collision with the inclined base. The mooring safety was also ensured by installing additional new parts on the quay. A mooring analysis and mooring safety review were performed with more rigorous modeling considering the nonlinearity of the mooring rope and fender. In order to secure additional safety of the mooring system under extreme environmental conditions, a safety assessment was conducted on the failures of the mooring components proposed in the marine mooring guidelines. Based on the results of the mooring analysis, it was confirmed that the Prelude FLNG can be safely moored even under the extreme conditions of typhoons, and a worst case scenario analysis verified that the mooring system design was robust enough. The proposed mooring analysis and design method will provide a basis for the safe mooring of ultra-large floating offshore structures of similar size in the future.