The Physiological Responses of Material-improved Working Clothes for Construction Site Worker (건설현장 작업복의 소재 기능성 향상에 따른 생리반응)

  • Kim, Seong-Suk;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.13 no.5
    • /
    • pp.752-758
    • /
    • 2011
  • In this paper, experiments to develop working clothes and evaluated, including the current and material-improved working clothes in relation to physiological functionality measurement. Experiments were conducted on subjects after wearing working clothes in an climate chamber, and the thermo-physiological response, such as human body temperature, micro-climate within the clothes, blood pressure, heart rate were measured. In this manner, the physiological functionality of improved working clothes was compared with that of current working clothes and evaluated. The summary of obtained results is as follows: For physiological functionality evaluation through material-improved working clothes, P working clothes showed significantly lower rectal temperature than C working clothes. For mean skin temperature, P's skin temperature was significantly higher than C's in the second half of the experiment. P working clothes's temperature around the thighs in Micro climate was significantly lower than that of the C working clothes. Also, humidity within the clothes showed similar trends. During the exercise period, C working clothes showed higher blood pressure than P, but P showed higher heart rates than C. Also, the oxygen uptake amount was higher in C than P during the exercise period, it explains that the energy consumption amount of P working clothes was smaller than that of C working clothes. Of the subjective evaluation, for temperature sensation, workers wearing P working clothes felt cooler. For humidity, C working clothes showed more humidity. For comfort, P working clothes were better, and for sense of fatigue, workers felt less tired wearing P working clothes. From results above, we can see that physiological functionality improved in the material-improved working clothes in the working clothes for construction site workers. The improvement of working clothes through functionality improvements not only will provide personal pleasantness to constriction site workers, but will also generate efficiency and productivity improvements at construction sites. All in all, the continuous study of functionality improvements in working clothes taking into consideration the human body's physiological responses is required.

Thermo-physiological Responses by Presence of Vents and Difference in Clothing Length for Construction Site Working Clothes (통기구 유무와 옷 길이 차이에 따른 건설현장 작업복의 온열생리반응)

  • Kim, Seong-Suk;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.20 no.2
    • /
    • pp.202-209
    • /
    • 2018
  • This study examined thermo-physiological responses according to the design change of construction site working clothes (control (C) working clothes; prototype (P) working clothes). We measured rectal temperature, skin temperature, micro-climate within the clothes and sweat rate. In the evaluation of physiological functionality, based on pattern improvement in working clothes, P working clothes showed significantly lower rectal temperatures, trunk and thigh skin temperatures than C working clothes. It is preferable that rectal temperature should be kept low during work that is not favorable to an increase in body temperature. P working clothes were more physiologically functional than C working clothes. In addition, P working clothes showed significantly lower temperatures in the trunk and thigh parts in a micro climate temperature. We could explain that the side seam zipper on the pants and the gusset on armpit parts create an air permeability effect of lowering the temperature of micro-climate. Aggressive ventilation through the slit of the garment is an important factor for the restoration of the physiological function of the worker at rest between work. Sweat rate showed a higher level in C working clothes than P working clothes. When working in a hot environment, workwear needs to be designed so that the worker is not exposed to thermal stress. Therefore, it was evaluated that the P work clothes used in this study alleviated the physiological burdens of heat.

Relationships between Exotherm Temperature and Working Life of Lightweight Polyester Mortars (경량 폴리머 모르타르의 발열온도특성과 가사시간의 관계)

  • ;;Katsunori Demura
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.315-318
    • /
    • 1999
  • This paper deals with the relationships between the exotherm temperature and working life of lightweight polyester mortar. Polyester mortars using types of lightweight aggregate compositions are prepared, and tested for exotherm temperature during hardening and working life. It is concluded from the test results that the behavior of exotherm temperature of lightweight polyester mortars is considerably affected by the lightweight aggregate composition. The lightweight polyester mortars using a lightweight aggregate compositeion ES gradually develop an exotherm temperature from 2$0^{\circ}C$, and give a working life. Then the exotherm temperature rises sharply up to a maximum exotherm temperature. The working life of the lightweight polyester mortars shortens with increasing catalyst and accelerator contents. The maximum exotherm temperature of the lightweight polyester mortars rises with increasing catalyst and accelerator contents.

  • PDF

Selection of Working fluid for the Organic Rankine Cycle to Utilize Low-Temperature Waste Heat (저온 폐열을 이용하기 위한 유기랭킨 사이클의 작동유체 선정에 관한 연구)

  • Cho, Soo-Yong;Cho, Chong-Hyun
    • New & Renewable Energy
    • /
    • v.10 no.4
    • /
    • pp.36-46
    • /
    • 2014
  • Low-grade heats are wasted even though an amount of their energy is huge. In the small and medium industrial complex sites, large amount of low-grade thermal energy generated during the manufacturing process is wasted if it is not used directly for building heating or air-conditioning. In order to utilize this waste thermal energy more efficiently, organic Rankine cycle (ORC) was adopted. The range of operating temperature of ORC was set to $60^{\circ}C$ from $30^{\circ}C$ applicable low-temperature waste heat. A study was conducted to select an appropriate organic working fluid based on these operating conditions. More than 60 working fluids were screened. Eleven working fluids were selected based on the requirements as working fluid for ORC such as environmentally friendly, safety, and good operation on the expander. Finally, six working fluids were selected by considering the operating temperature ranges. Then, a cycle analysis was conducted with these six working fluids. As a results, R-245fa and R-134a appeared as appropriate working fluids for ORC operating at low-temperature condition based on the system efficiency and the turbine output power.

A Comparison between the Internal Saturation Temperature of Working Fluid and the Surface Temperature of Adiabatic Zone of Two-Phase Closed Thermosyphons with Various Helical Grooves (평관형 및 나선 그루브형 열사이폰 내부 작동유체의 포화온도와 단열부의 표면온도에 관한 연구)

  • Han, K.I.;Cho, D.H.;Park, J.U.;Lee, S.J.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1243-1249
    • /
    • 2004
  • This study is focused on the comparison between the internal saturation temperature of the working fluid and the surface temperature of adiabatic zone of two-phase closed thermosyphons with various helical grooves. Distilled water, methanol and ethanol have been used as the working fluid. In the present work, a copper tube of the length of 1200mm and 14.28mm of inside diameter is used as the container of the thermosyphon. Each of the evaporator and the condenser section has a length of 550mm, while the remaining part of the thermosyphon tube is adiabatic section. A experimental study was carried out for analyzing the performances of having 50, 60, 70, 80, 90 helical grooves. A plain thermosyphon having the same inner and outer diameter as the grooved thermosyphons is also tested for the comparison. The results show that the numbers of grooves and the type of working fluids are very important factors for the operation of thermosyphons. A good agreement between the internal saturation temperature of working fluid and the surface temperature of adiabatic zone of two-phase closed thermosyphons with various helical grooves is obtained.

  • PDF

Effect of Working Temperature on Sensitivity of Au/SnO2 Core-Shell Structure Nanoparticles for CO Gas (Au/SnO2 core-shell 나노구조 센서의 구동온도가 CO 감동에 미치는 영향)

  • Yu, Yeon-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.456-460
    • /
    • 2012
  • Au/$SnO_2$ core-shell structure nanoparticles (NPs) were synthesized by microwave hydrothermal method, and the effect of working temperature on sensitivity of Au/$SnO_2$ core-shell NPs for CO gas was investigated. The $SnO_2$ shell layer was consisted of $SnO_2$ primary particles with 4.5 nm diameter. The response of Au/$SnO_2$ core-shell NPs for CO gas was maximized at the working temperature of $350^{\circ}C$ while the sensitivity increased with decreasing the working temperature due to the low grain size effect of $SnO_2$ NPs on the response of CO gas.

An Approximate Analysis Method to Predict Power Output Characteristics of Stilting Engine (스터얼링 기관의 근사 출력 계산법)

  • 김태한;장익주;이시민
    • Journal of Biosystems Engineering
    • /
    • v.20 no.3
    • /
    • pp.205-216
    • /
    • 1995
  • A fast and inexpensive approximate analysis method to predict power output characteristics of the Stilting engines in a preliminary design stage was investigated. In basic equations proposed by Walker, typical temperatures of working fluids in expansion and compression spaces were treated as those of working fluids in heater and cooler respectively. While the temperature of working fluid in the expansion space was actually lower than that of working fluid in the heater, the temperature of working fluid in the compression space was higher than that of working fluids in the cooler. In this paper, the working fluid temperature of expansion space was treated as lower than the heater temperature and that of compression space was treated as higher than the cooler temperature. Also, according to them, the power output characteristics of the Stirling engine were evaluated with respect to the GPU-3 and 4-215 Stilting engines. The following conclusions were drawn from the analysis. 1. Using the available experimental data from the GPU-3 Stirling engine, it was shown that the approximate analysis predicts the brake power with a maximum error of 19 percent at 1, 000rpm and with a minimum error of 3 percent at 2, 000rpm. 2. The approximate analysis data which for the GPU-3 Stirling engine were much closer to the experimental data than those of adiabatic 2nd order and 3rd order analysis within 1, 500rpm to 2, 500rpm. 3. The approximate analysis data which for the GPU-3 and 4-215 Stilting engines were much closer to the experimental data than those of the Beal number analysis.

  • PDF

A Study of various Working Fluid in the Low Temperature Heat Pipe (저온용(低溫用) 히이트파이프의 작동유체(作動流體)에 관한 연구(硏究))

  • Chang, Young-Suk;Lee, Young-Soo;Seoh, Jeong-Il
    • Solar Energy
    • /
    • v.6 no.2
    • /
    • pp.76-85
    • /
    • 1986
  • The study on the characteristics of heat transfer by various working fluid and wick structure is an important subject in order to design low temperature heat pipe. The purpose of this research was to study the heat transfer characteristics of heat pipe according to various working fluid and wick thickness by ADI method and experimental results. As the results the heat transfer by various working fluid could improve by good heat conductivity of fluid and small ratio t/k. The working fluid could be selected in close vicinity to boiling temperature among fluid properties the value of ratio little influenced heat transfer of heat pipe. In case of distilled water, the response of the effect in heat recovery was more rapidly showed than response of other working fluid. The maximum heat flux increased in proportion to the characteristics of working fluid but the pore and wick permeability among wick characteristic was little effect in the wetting state.

  • PDF

A Study on the Working Condition Effecting on the Maximum Working Temperature and Surface Roughness in Side Wall End Milling Using Design of Experiment (실험계획법을 이용한 엔드밀 가공 시 최대가공온도와 표면조도에 미치는 가공조건에 관한 연구)

  • Hong, Do-Kwan;Ahn, Chan-Woo;Baek, Hwang-Soon;Choi, Seok-Chang;Park, Il-Soo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.3
    • /
    • pp.46-53
    • /
    • 2009
  • To find the working condition is one of the important factors in precision machining. In this study, we analyzed maximum working temperature by infra-red camera and surface roughness in side wall end milling using design of experiment (DOE): RSM(response surface methodology), ANOM(analysis of means) and ANOVA(analysis of variance) by table of orthogonal array. ANOM and ANOVA are well adapted to select sensitivity of design variables for maximum working temperature and surface roughness. The effective design variables and their levels should be determined using ANOM, ANOVA. RSM is presented 2nd order approximation polynomial of maximum working temperature and surface roughness is composed with design variables. Therefore, it is expected that the proposed procedure using design of experiment : table of orthogonal array, ANOM, ANOVA and RSM can be easily utilized to solve the problem of working condition.

  • PDF

Transient behavior of cryogenic thermosiphon working with R14 and nitrogen mixture (R14와 질소 혼합유체를 사용하는 극저온 열사이펀의 과도상태 거동)

  • Lee, Ji-Sung;Jeong, Sang-Kwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.1
    • /
    • pp.66-70
    • /
    • 2010
  • The operational temperature range of thermosiphon is generally limited from the critical point to the triple point of the working fluid to maintain two-phase state. Thermosiphon with mixed working fluid has a potential to widen the operational temperature range. In this study, the physical behavior of mixed working fluid during the transient operation of thermosiphon was analyzed with temperature-mole fraction diagram. The condenser and the evaporator temperature variations were explained by the dew line and the bubble line of the mixture. It is encouraging that the thermosiphon operation commences early with larger fraction of high boiling point component, but the temperature gap between the condenser and the evaporator due to the separation of two components has a negative effect on the officient cool down process.