Characteristics of domestic coals and efficient control of coal dust (국내 석탄광 분진의 특성과 효율적 제어)

  • Kim, Soo Hong;Kwon, Jun Wook;Kim, Sun Myung;Kim, Yun kwang;Jang, Yun Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.4
    • /
    • pp.589-609
    • /
    • 2017
  • This study carried out the density and energy dispersive X-ray spectroscopy and particle size analysis which are the physical characteristics of coal dust by collecting samples of coal dust in the five domestic mines to control the coal dust through ventilation in the workplace for coal mining in the country. This will contribute to a more comfortable working environment by understanding the physical characteristics of the coal dust which is derived from any hard coal produced domestically. In particular, the result of PSA analysis showed that the size of coal dust sample for this study ranged from $0.007{\sim}88.614{\mu}m$ were the particles less than $3.5{\mu}m$, the size range responsible for pneumoconiosis. To observe the flow of coal dust collected on the wind speed, the fallout of coal dust produced by the wind tunnel for the wind was measured and the particle size analysis of coal dust fallout was carried out. In addition, airborne dust is measured according to the mine velocity by using a multi-stage Anderson sampler in the mine where fine dust is generated in a large amount and the wind speed is found out to control the coal dust below $3.5{\mu}m$. In addition, natural ventilation pressure of A mine was calculated to prevent over design of the main fan.

Use of Smoke-less Tobacco Amongst the Staff of Tertiary Care Hospitals in the Largest City of Pakistan

  • Valliani, Arif;Ahmed, Bilawal;Nanji, Kashmira;Valliani, Salimah;Zulfiqar, Beenish;Fakih, Misbah;Mehdi, Mehwish;Khan, Anam;Sheikh, Sana Arshad;Fatima, Nida;Ahmad, Sobia;Farah, Fariya;Saleem, Shaheera;Ather, Sana;Majid, Syed Khubaib;Hashmi, Syed Salman;Arjan, Sunil
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.5
    • /
    • pp.2315-2317
    • /
    • 2012
  • Background: Use of smoke-less tobacco (SLT) is very common in South and South-East Asian countries. It is significantly associated with various types of cancers. The objectives of this study were to assess the proportion of hospital staff that use SLT, and to identify the factors associated with its use and their practices. Methods: In a cross-sectional study, 560 staff of two tertiary care hospitals were interviewed in the year 2009. Nurses, ward boys and technicians were counted as a paramedic staff while drivers, peons, security guards and housekeeping staff were labeled as non-paramedic staff. SLT use was considered as usage of any of the following: betel quid (paan) with or without tobacco, betel nuts with or without tobacco (gutkha) and snuff (naswar). Results: About half (48.6%) of the hospital staff were using at least one type of SLT. Factors found to be statistically significant with SLT were being a male (OR=2.5; 95% CI=1.8-3.7); having no/fewer years of education (OR=1.7; 95% CI=1.2-2.4) and working as non-paramedic staff (OR=2.6; 95% CI=1.8-3.8). Majority of SLT users were using it on regular basis, for > 5 years and keeping the tobacco products in the oral cavity for >30 minutes. About half of the users started due to peer pressure and had tried to quit this habit but failed. Conclusion: In this study, about half of the study participants were using SLT in different forms. We suggest educational and behavioral interventions for control of SLT usage.

A Study on Modelling and Tracking Control System Design of RTGC(Rubber-Tired Gantry Crane) (RTGC의 모델링 및 주행제어기 설계에 관한 연구)

  • Jeong, Ji-Hyun;Lee, Dong-Seok;Jeong, Jeong-Soon;Kim, Young-Bok
    • Journal of Navigation and Port Research
    • /
    • v.34 no.6
    • /
    • pp.479-485
    • /
    • 2010
  • To handle container effectively is one of the most important factors in a port because working time is linked soon into cost. Since the middle of 1990s, RMGC(Rail-Mounted Gantry Crane) and RTGC(Rubber-Tired Gantry Crane) have been developed and widely used to operate containers in the yard. The RTGC is more difficult than RMGC in the automatic control system design. Although, the RTGC is largely advantaged to free driving environment, it has some considerable disadvantages in the system operating. In general, the problems are due to tire slip and lack of tire pressure etc. Therefore, a desirable research result has not been shown in this time. So, in this paper, we propose a new approach to design tracking control system for the RTGC in which the mathematical modeling is included. From the simulation results, the control performance of the designed control systems is evaluated.

Study on Wet chemical Etching Characterization of Zinc Oxide Film for Transparency Conductive Oxide Application (투명 전도성 산화물 전극으로의 응용을 위한 산화아연(ZnO) 코팅막의 습식 식각 특성연구)

  • Yoo, Dong-Geun;Kim, Myoung-Hwa;Jeong, Seong-Hun;Boo, Jin-Hyo
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.1
    • /
    • pp.73-79
    • /
    • 2008
  • In order to apply for transparent conductive oxide(TCO), we deposited ZnO thin films on the glass at room temperature by RF magnetron sputtering method. Deposition conditions for high transmittance and low resistivity were optimized in our previous studies. Under the deposition condition with the RF power of 200 W, target to substrate distance of 30 mm and working pressure of 5 mTorr, highly conductive($7.4{\times}10^{-3}{\Omega}cm$) and transparent(over 85%) ZnO films were prepared. Highly oriented ZnO film in the [002] direction were obtained with specifically designed ZnO targets. Systematic study on dependence of deposition parameters on electrical and optical properties of the as-grown ZnO films were mainly investigated in this work. And for application tests using these films as transparent conductive oxide anodes, wet chemical etching behaviors of ZnO films were also investigated using various chemicals. Wet-chemical etching behavior of ZnO films were investigated using various acid solutions. The concentrations of these different acid solutions were controlled to study the etching shapes and etching rate. ZnO films were anisotropically etched at various concentrations and wet etching led to crater-like surface structure. Also we firstly found that the etching rate and etching shapes of ZnO films strongly depended on the etchant concentrations (i.e. pH) and the etching rate is exponentially decreased with increasing pH values regardless of the acid etchants.

AN ELECTROCHEMICAL STUDY BY USING A POTENTIOSTAT ON THE CORROSION OF AMALGAMS IN SALIVA (Potentiostat를 이용한 타액에서의 아말감부식에 대한 전기화학적 연구)

  • Son, Yoon-Hee;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.534-548
    • /
    • 1994
  • The purpose of this study is to observe the corrosion characteristics of seven dental amalgams (CAULK FINE CUT, CAULK SPHERICAL, OPTALLOY II, DISPERSALLOY, HI VERALOY, TYTIN, VALIANT) through the anodic polarization curve obtained by using a potentiostat. After each amalgam alloy and Hg being triturated, the triturated mass was inserted into the cylindrical metal mold, and condensed by hydrolic pressure(160 kg/$cm^2$). Each specimen was removed from the metal mold. 24 hours after condensation, specimens were polished with the emery paper and stored at room temperature for 1 week. The anodic polarization curves were employed to compare the corrosion behaviours of the amalgam in 0.9% saline solution, Fusayama's artificial saliva, and stimulated parotid saliva at $37^{\circ}C$ with 3-electrode potentiostat. After the immersion of specimen in electrolyte for 1 hour, the potential scan was begun. The potential scan range was. -1700m V ~ + 400m V(vs. S. C. E) in the working electrode and the scan rate was 50m V /sec. The results were as follows, 1. The corrosion potential, the potential of anodic current peak, and transpassive potential in the stimulated parotid saliva shifted to more anodic direction than those in saline solution, and the current density in the stimulated parotid saliva was lower than that in saline solution. Those in Fusayama's artificial saliva was similar to those in stimulated parotid saliva. 2. The anodic polarization profiles in Fusayama's artificial saliva and stimulated parotid saliva indicated a region of slow slope current density, which is extending from the corrosion potential to the potential of anodic current peak, but that in 0.9% saline solution indicated no region of slow slope. 3. The corrosion potentials for CAULK FINE CUT, CAULK SPHERICAL, and OPT ALLOY II had the similarity in 0.9% saline solution, Fusayama's artificial saliva and stimulated parotid saliva, but those for high coper amalgam and VALIANT had no similarity. 4. The current density for TYTIN amalgam in stimulated parotid saliva was the lowest among the others. 5. As for current density, there was no significant difference between palladium enriched VALINAT and other high copper amalgams.

  • PDF

Nephropathy in Chronic Lead Poisoning (만성 연중독자에서 발생한 신장해)

  • Kim, Byoung-Gwon;Kim, Sung-Ryul;Hong, Young-Seoub;Rha, Seo-Hee;Kim, Jung-Man;Jung, Kap-Yull;Kim, Joon-Youn
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.1 s.52
    • /
    • pp.43-50
    • /
    • 1996
  • We experienced a case of nephropathy in chronic lead poisoning. The patient was 43-year-old male who has been working in secondary lead smelting plant for 14 years. On admission, blood pressure was 160/90 mmHg and the others were non-specific. In past history, he received chelating agent administration for lead poisoning irregularly and medicated for gout, and the blood lead concentration was $180.0{\mu}g/dl$ on 2 months before admission. Smoking habit has been 1 pack per day for 15 years and drinking habit has been 1 bottle of Soju per day but less flow. In liver function test, AST/ALT were 27/28 IU/l and $\gamma-GT$ was 456 IU/l. In blood test, Hb : 11.5 g/dl, Hct : 34.0% and basophilic stipplings were found in peripheral blood smear. Chest PA was normal and abdominal ultrasonographic finding was non-specific except fatty liver. In the test of lead exposure indices, $PbB:83.0{\mu}g/dl,\;PbU:28.3{\mu}g/l$, and blood ZPP was $300.0{\mu}g/dl$. And in renal function test, BUN : 31.4 mg/dl, blood creatinine : 2.7mg/dl, blood uric acid. 9.1 mg/dl, urinary albumin : 100.0 mg/g creatinine, urinary $\alpha_1-microglobulin$ : 120.5 mg/g creatinine, urinary $\beta_2-microglobulin$ : $183.8{\mu}g/g$ creatinine, and 24 hours urinary creatinine clearance was 31.9 ml/min. The ultrasonoguided renal biopsy showed the global sclerosis of glomerulus, moderate atrophy and loss of tubule, and interstitial fibrosis in light microscopy. There were diffuse losses of brush border of proximal tubule in electronmicroscopy.

  • PDF

A Study on Experiments the Environmental Conditions and the Adaptation of the Human Body in the Vinyl House (Vinyl House 내의 환경조건과 인체적응에 관한 실험연구)

  • Shim, Bu-Ja
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.1 s.45
    • /
    • pp.59-73
    • /
    • 1994
  • The purpose of this study is to experiments the environmental conditions and the adaption of the human body in the vinyl house. The study was done in spring and winter and experimental clothes were used working clothes in the vinyl house. The results are as follows. 1. Environmental Conditions In the spring season, the indoor air temperature was $27.4{\pm}3.7^{\circ}C$ and the outdoor air temperature was $14.4{\pm}2.7^{\circ}C$. In the winter season, the indoor air temperature was $18.3{\pm}4.8^{\circ}C$ and the outdoor air temperature was $7.6{\pm}2.5^{\circ}C$ on the average. 2. Skin Temperature In the spring season, the mean skin temperatures indoor and outdoor were $33.81{\pm}0.7^{\circ}C\;and\;31.57{\pm}0.8^{\circ}C$ respectively, a difference of $2.24^{\circ}C$. In the winter season, they were $31.95{\pm}1.93^{\circ}C\;and\;29.86{\pm}0.55^{\circ}C$ respectively, a difference of $2.09^{\circ}C$. 3. Clothing Climate In the spring season, the temperature and humidity in the inner layer of clothing were $34.77{\pm}0.80^{\circ}C\;and\;70.75{\pm}1.65%$ indoor, $31.9{\pm}0.52^{\circ}C\;and\;51.9{\pm}3.70%$ outdoor respectively. In the winter season, those were $32.52{\pm}1.04^{\circ}C\;and\;64.65{\pm}3.68%$ indoor, $30.27{\pm}0.96^{\circ}C\;and\;45.07{\pm}2.68%$ outdoor respectively. 4. Physiological Factors Body temperature increased slightly and the pulse rate also rises, but blood pressure decreased a little with the rise of environmental temperature both in the spring and winter seasons. 5. Psychological Factors Thermal sensation in the spring season was expressed as 'slightly warm' or 'warm' indoor and as 'neutral' in the open air, while in the winter it was expressed as 'neutral' or 'slightly warm' outdoor the house and as 'cold' in the open air. Comfort sensation was characterized as 'uncomfortable' or 'slightly uncomfortable' indoor both in the spring and winter seasons, but in the open air it was characterized as 'comfortable' in the spring and as 'slightly uncomfortable' in the winter.

  • PDF

The Study of Ag Thin Film of Suitable Anode for T-OLED: Focused on Nanotribology Methode (UV 처리에 의한 T-OLED용 산화전극에 적합한 Ag 박막연구: Nano-Mechanics 특성 분석을 중심으로)

  • Lee, Kyu Young;Kim, Soo In;Kim, Joo Young;Kwon, Ku Eun;Kang, Yong Wook;Son, Ji Won;Jeon, Jin Woong;Kim, Min Chul;Lee, Chang Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.6
    • /
    • pp.328-332
    • /
    • 2012
  • The work function of Ag (silver) is too low (~4.3 eV) to be used as an electrode of T-OLED (Top Emission Organic Light Emitting Diode). To solve this weakness, researches used plasma-, UV-, or thermal treatment on Ag films in order to increase the work function (~5.0 eV). So, most of studies have focused only on the work function of various treated Ag films, but studies focusing on nanomechanical properties were very important to investigate the efficiency and life time of T-OLED etc. In this paper, we focused on the mechanical properties of the Ag and $AgO_x$ film. The Ag was deposited on a glass substrate with the thickness of 150 nm by using rf-magnetron sputter with the power was fixed at 100 W and working pressure was 3 mTorr. The deposited Ag film was UV treated by UV lamp for several minutes (0~9 min). We measured the sheet resistance and mechanical property of the deposited film. From the experimental result, there were some differences of the sheet resistance and surface hardness of Ag thin film between short time (0~3 min) and long time UV treatment. These result presumed that the induced stress was taken place by the surface oxidation after UV treatment.

Atrial Septal Defect Closure: Comparison of Vertical Axillary Minithoracotomy and Median Sternotomy

  • Poyrazoglu, Huseyin Hakan;Avsar, Mustafa Kemal;Demir, Serafettin;Karakaya, Zeynep;Guler, Tayfun;Tor, Funda
    • Journal of Chest Surgery
    • /
    • v.46 no.5
    • /
    • pp.340-345
    • /
    • 2013
  • Background: This study aims to evaluate whether or not the method of right vertical axillary minithoracotomy (RVAM) is preferable to and as reliable as conventional sternotomy surgery, and also assesses its cosmetic results. Methods: Thirty-three patients (7 males, 26 females) with atrial septal defect were admitted to the Cardiovascular Surgery Clinic of Cukurova University from December 2005 until January 2010. The patients' ages ranged from 3 to 22. Patients who underwent vertical axillary minithracotomy were assigned to group I, and those undergoing conventional sternotomy, to group II. Group I and group II were compared with regard to the preoperative, perioperative and postoperative variables. Group I included 12 females and 4 males with an average age of $16.5{\pm}9.7$. Group II comprised 14 female and 3 male patients with an average age of $18.5{\pm}9.8$ showing similar features and pathologies. The cases were in Class I-II according to the New York Heart Association (NYHA) Classification, and patients with other cardiac and systemic problems were not included in the study. The ratio of the systemic blood flow to the pulmonary blood flow (Qp/Qs) was $1.8{\pm}0.2$. The average pulmonary artery pressure was $35{\pm}10$ mmHg. Following the diagnosis, performing elective surgery was planned. Results: No significant difference was detected in the average time of the patients' extraportal circulation, cross-clamp and surgery (p>0.05). In the early postoperative period of the cases, the duration of mechanical ventilator support, the drainage volume in the first 24 hours, and the hospitalization time in the intensive care unit were similar (p>0.05). Postoperative pains were evaluated together with narcotic analgesics taken intravenously or orally. While 7 cases (43.7%) in group I needed postoperative analgesics, 12 cases (70.6%) in group II needed them. No mortality or major morbidity has occurred in the patients. The incision style and sizes in all of the patients undergoing RVAM were preserved as they were at the beginning. Furthermore, the patients of group I were mobilized more quickly than the patients of group II. The patients of group I were quite pleased with the psychological and cosmetic results. No residual defects have been found in the early postoperative period and after the end of the follow-up periods. All of the patients achieved functional capacity per NYHA. No deformation of breast growth has been detected during 18 months of follow-up for the group I patients, who underwent RVAM. Conclusion: To conclude, the repair of atrial septal defect by RVAM, apart from the limited working zone for the surgeon in these pathologies as compared to sternotomymay be considered in terms of the outcomes, and early and late complications. And this has accounted for less need of analgesics and better cosmetic results in recent years.

Fabrication and Characteristics of a White Emission Electroluminicent Device (백색 전계발광소자의 제작과 그 특성)

  • Kim, Woo-Hyun;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.295-303
    • /
    • 2001
  • White emission thin film electroluminecent device was fabricated with ZnS for phosphor layers and BST ferroelectric thin film for insulating layers. The ZnS:Mn and $ZnS:SmF_3$ layers were used for emission of red color. Also the $ZnS:TbF_3$ and $ZnS:AgF_3$ layers were used to emission of green and blue color, respectively. And the fabrication conditions of the BST insulating layers were followings, that is, the composition ratio of target, substrate temperature, working pressure and operating gas ratio were $Ba_{0.5}Sr_{0.5}Ti_{0.3}$, $400^{\circ}C$, 30 mTorr and 9:1, respectively. The thickness of phosphor were 150 nm for each layers and the insulating layers of upper and bottom were 400 nm and 200 nm, respectively. The luminesence threshold voltage was $75\;V_{rms}$ and the maximum brightness of the thin film electroluminecent device was $3200\;cd/m^2$ at $100\;V_{rms}$.

  • PDF