• Title/Summary/Keyword: Working Gas

Search Result 705, Processing Time 0.031 seconds

Analysis of Patients with Acute Carbon Monoxide Poisoning in one Hospital (일개 병원에서의 일산화탄소 중독증으로 내원한 환자에 대한 분석)

  • Kim Kyung Hwan;Kim Ah Jin;Shin Dong Wun;Rho Jun Young
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.3 no.1
    • /
    • pp.27-32
    • /
    • 2005
  • Purpose: The frequency of carbon monoxide poisoning has been decreased in the interior of the Korea. But occasionally it is occurred and the risk of exposure is high in working place so far. Because of the characteristics of gas, the detection of exposure and poisoning could be delayed and fatality is high. We should apprehend of carbon monoxide poisoning. So we would report analysis of patients with carbon monoxide poisoning. Methods: A retrospective review of CO poisoned patients visited emergency department from January 2000 to December 2004 was conducted. Results: 24 patients were enrolled. Their average of age was $37.6\pm20.9$ years old and COHb was $19.4\pm13.32\%$. The blood level of initial COHb and mental status on arrival were not correlated each other. The blood level of initial COHb and loss of consciousness were not correlated, too. Initial electrocardiography (EKG) was not correlated with cardiac enzymes such as CK-MB and troponin I. But base excess was correlated with mental status on arrival and complication such as rhabdomyolysis. Hyperbaric oxygen therapy was correlated with base excess and mental status on arrival. Conclusion: The clinical features of carbon monoxide poisoning are nonspecific. For proper diagnosis, it is important that we should consider patient's environment and take patient's history carefully. The blood level of initial COHb does not reflect severity of poisoning accurately. So We should determine the treatment of choice depending on patient's status.

  • PDF

The characteristics of farmer's dermal exposure during pesticide spraying and dilution in cut rose greenhouse (절화장미 시설하우스에서 방제 작업시 농약의 피부노출 특성)

  • Kim, Hyo-Cher;Kim, Kyung-Ran;Lee, Kyung-Suk;Kim, Kyung-Su;Cho, Kyun-Ah
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.3
    • /
    • pp.203-211
    • /
    • 2007
  • This study was conducted in cut rose cultivation field in Goyang to evaluate pesticide exposure of farmers and the relationship between the exposure and work environment/method for cut rose farmers. Dermal exposure was assessed with patch (thin chromatography layer paper), cotton glove by body parts during mixing and spraying works in which pyrethroid, organophosphate, carbamate pesticide were used in 4 cut rose greenhouses located in Goyang province, checking characteristics of environment/working method at the same time. Body parts assessed were as follows ; glove : hand, patch : head, neck(front/back), chest, back, shoulder(right/left), upperarm(right/left), forearm(right/left), thigh(right/left), shin(right/left). Pesticides were analyzed using gas chromatography(NPD/FID) after extracting with ethyl acetate. Exposure amount differed according to pesticide type. But after standardizing with total net weight of pesticide sprayed, there were no significant difference among pesticides. There were significant difference in exposure amount among body parts(especially exposure amount of thigh, shin were more than the others), which means exposure happen not by pesticide dispersion in air but by contact with cut rose(leaf, branch) indirectly. Walking forward during spraying made farmers more exposed than waling backward, these results means contacts with leaves/branches made exposure happen in cut rose greenhouse also. As a result, pesticide exposure in cut rose greenhouse was related with contact of leaf/branch which pesticide remained in, which made exposure pattern (especially exposure amount) differ by body parts

Development of Variable Deposition manufacturing for Ethylene Vinyl Acettecopolymer (EVA를 이용한 가변 용착 쾌속 조형 공정의 개발)

  • Lee, Sang-Ho;Sin, Bo-Seong;Jeong, Jun-Ho;An, Dong-Gyu;Yang, Dong-Yeol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.9
    • /
    • pp.189-195
    • /
    • 2000
  • RP techniques have their unique characteristics according to the working principles : star-stepped surface of parts due to layer-by-layer stacking low build speed caused by line-by-line solidification to fish one layer and post processing to improve surface finish etc The objective of this study is to propose a new RP technique Variable Deposition Mnanufacturing (VDM) which can make up for the disadvantages of the existing RP techniques and to develop an apparatus to implement the technique. The proposed process can greatly reduce the build time and improve the surface finish of parts generated. Experiments are carried out to obtain the range of temperature of molten material to maintain its fluidity and to investigate the effect of gas cooling on the preservation of the slopes. Some simple shapes such as a line-shape an S-shape and a circle-shape are fabricated from Ethylene Vinyl Acetatecopolymer(EVA) In order to examine the applicability of VDM to more general shapes a tensile specimen and a yo-yo shape were manufactured by the proposed RP method using EVA material as a trial approach. The current basic study shows a high potential of practical use of the proposed VDM process to prototyping of a general three-dimensional shape.

  • PDF

A Study on the Chattering under Cryogenic Flow Test of a Oxidizer Shutoff Valve (산화제 개폐밸브의 극저온 유동시험에서 채터링의 고찰)

  • Lee, JoongYoup;Han, SangYeop;Lee, SooYong
    • Aerospace Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.108-117
    • /
    • 2013
  • The oxidizer shutoff valve of a gas generator controls the mass flow rate of the propellant of a rocket engine using pilot pressure and spring the force of the valve. The developing oxidizer shutoff valve can be shut off if the pilot pressure is removed from the actuator. Therefore, force balancing is necessary to analyze the characteristics of the forces with respect to the opening and closing of the valve in order to evaluate its performance. In light of this, the valve has been designed to adjust the control pressure required to open the poppet and to determine the working fluid pressure at which the valve starts to close. Under cryogenic flow test as a tests level of C.R.T(Control Random Test), the chattering phenomena occurred due to much leakage of a metal seat section. The pressure for chattering of the oxidizer valve is predicted at about 11 bar using force balancing analysis.

Experimental Study on Effects of Inlet Boundary Layer Thickness and Boundary Layer Fence in a Turbine Cascade (터빈 캐스케이드 입구경계층 두께와 경계층 펜스 효과에 대한 실험적 연구)

  • Jun, Y.M.;Chung, J.T.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.853-858
    • /
    • 2000
  • The working fluid from the combustor to the turbine stage of a gas turbine makes various boundary layer thickness. Since the inlet boundary layer thickness is one of the important factors that affect the turbine efficiency. It is necessary to investigate secondary flow and loss with various boundary layer thickness conditions. In the present study, the effect of various inlet boundary layer thickness on secondary flow and loss and the proper height of the boundary layer fences for various boundary layer thickness were investigated. Measurements of secondary flow velocity and total pressure loss within and downstream of the passage were taken under 5 boundary layer thickness conditions, 16, 36, 52, 69, 110mm. It was found that total pressure loss and secondary flow areas were increased with increase of thickness but they were maintained almost at the same position. At the fellowing research about the boundary layer fences, 1/6, 1/3, 1/2 of each inlet boundary layer thickness and 12mm were used as the fence heights. As a result, it was observed that the proper height of the fences was generally constant since the passage vortex remained almost at the same position. Therefore once the geometry of a cascade is decided, the location of the Passage vortex and the proper fence height are appeared to be determined at the same time. When the inlet boundary layer thickness is relatively small, the loss caused by the proper fence becomes bigger than endwall loss so that it dominates secondary loss. In these cases the proper fence hight is decided not by the cascade geometry but by the inlet boundary layer thickness as previous investigations.

  • PDF

Investigation of Bubble Behavior in Rectangular Microchannels for Different Aspect Ratios (다른 세장비의 사각 마이크로채널 내의 기포 거동에 관한 연구)

  • Choi, Chi-Woong;Yu, Dong-In;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.5
    • /
    • pp.471-479
    • /
    • 2010
  • The adiabatic two-phase flow in single rectangular microchannels was studied for different aspect ratios. The working fluids were liquid water and nitrogen gas. The hydraulic diameters of the rectangular microchannels were 490, 322, and $143\;{\mu}m$, and the widths of the microchannels were around $500\;{\mu}m$. The two-phase flow pattern was visualized using a high-speed camera and a long-distance microscope. This study was focused on bubble flow regimes. From the visualized images, the bubble velocity, bubble length, number of bubbles, and void fraction were evaluated. Further, the pressure drop in a single bubble was evaluated by using a unit cell model. The bubble velocity is proportional to the superficial velocity. Further, the relationship between the void fraction and the volumetric quality is linear. The pressure drop in a single elongated bubble is strongly related to the aspect ratio. Finally, the new correlation about the pressure drop of a single elongated bubble in the rectangular microchannel was proposed.

Effect of process parameters of antimony doped tin oxide films prepared on flexible substrate at room temperature

  • Lee, Seong-Uk;Hong, Byeong-Yu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.175-175
    • /
    • 2010
  • Transparent conducting oxide (TCO) films are widely used as transparent conducting thin film material for application in various fields such as solar cells, optoelectronic devices, heat mirrors and gas sensors, etc. Recently the increased utilization of many transparent electrodes has accelerated the development of inexpensive TCO materials. Indium tin oxide (ITO) film is well-known for TCO materials because of its low resistivity, but there is disadvantage that it is too expensive. ZnO film is cheaper than ITO but it shows thermally poor stability. On the contrary, antimony-doped tin oxide films (ATO) are more stable than TCO films such as Al-doped zinc oxide (AZO) and ITO. Moreover, SnO2 film shows the best thermal and chemical stability, low cost and mechanical durability except the poor conductivity. However, annealing is proved to improve the conductivity of ATO film. Therefore, in this work, antimony (6 wt%) doped tin oxide films to improve the conductivity were deposited on 7059 corning glass by RF magnetron sputtering method for the application to transparent electrodes. In general, of all TCO films, glass is the most commonly selected substrate. However, for future development in flexible devices, glass is limited by its intrinsic inflexibility. In this study, we report the growth and properties of antimony doped tin oxide (ATO) films deposited on PES flexible substrate by using RF magnetron sputtering. The optimization process was performed varying the sputtering parameters, such as RF power and working pressure, and parameter effect on the structural, electrical and optical properties of the ATO films were investigated.

  • PDF

Evaluation and Selection Method of Best Available Techniques for Integrated Environmental Management System (통합환경관리제도 운영을 위한 최적가용기법 평가·선정기법 연구)

  • Park, Jae Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.3
    • /
    • pp.348-358
    • /
    • 2017
  • The process of evaluating and selecting the best available techniques presents various characteristics for each country. In the case of EU, BAT is selected through TWG meeting after first screening, mass and energy balance, impact assessment and decision support process. Korea has proposed four principles to select BAT that can be carbon neutral for each environmental infrastructure in order to reduce greenhouse gas emissions. In order to evaluate and select the best available technique, it is necessary to differentiate the method according to whether it is a technique generally applied at the current workplace, whether it is a single technique or a combination technique, and whether it is a technology technique or management technique. In the case of a single technique, it should be evaluated whether it is a technique applied in the workplace, excessive cost, superior environmental technique over BAT, and secondary environmental pollution. In the case of multiple techniques, it is necessary to examine whether the emission standards are met and whether the pollutants can be treated at the same level as BAT. In the case of BAT candidates for management techniques, whether or not they contribute directly or indirectly to lowering the emission level of pollutants can be an important evaluation item. In the case of environmental techniques that are not generally applied in the workplace, it is recommended that the following 8 steps be carried out, including those prescribed by law. In the first stage, the list of performance evaluation factors is listed. In the second stage, the level of disposal of pollutants and the level of satisfaction with standards are listed. In the third stage, the environmental evaluation elements are listed. In the fourth stage, Is to list the economic evaluation elements, step 6 is to list the pollution and accident prevention evaluation factors, step 7 is the quantitative evaluation of the technical working group, and step 8 is BAT confirmation through deliberation of the central environmental policy committee.

Analysis on the Optimum Location of an Wet Air Cleaner in a Livestock House using CFD technology (전산유체역학 기법을 이용한 돈사 내 습식 공기 정화기의 적정 위치 설계)

  • Kwon, Kyeong-Seok;Lee, In-Bok;Hwang, Hyun-Seob;Bitog, Jessie.P.;Hong, Se-Woon;Seo, Il-Hwan;Choi, Ji-Sun;Song, Sang-Hyeon;Moon, Oun-Kyung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.3
    • /
    • pp.19-29
    • /
    • 2010
  • In South Korea, as the living standard has been getting higher, meat consumption is steadily increasing. To meet the country's demand, livestock houses become larger and wider with increased raising density. In larger livestock houses, pollutants such as flake of pig skin, excrement, odor, various dusts and noxious gas like ammonia are excessively accumulated inside the facility. These will cause weak immunity for the pigs, diminution of productivity and degeneration of working condition. These problems can be solved through the ventilation performance of the facility. In the winter time, ventilation must be controlled to minimum to maintain a suitable thermal condition. However, this affects the other internal environmental condition because of the minimum ventilation. The installation of "wet air cleaner" especially in the winter time can be an alternative solution. For efficient application of this machine, there is a need to understand the existing ventilation condition and analyze the interaction of existing ventilation system with the wet air cleaner considering its appropriate location. In this study, the existing ventilation system as well as the internal environmental condition negatively inside the facility with the wet air cleaner has been studied using CFD technology. The CFD simulation model was validated from the study conducted by Seo et al. (2008). Results show that the elimination rate of ammonia was 39.4 % and stability could be improved to 35.1 % (Comparing case 5 to 1 where wet air cleaner machine was not used). It can therefore be concluded that case 5 shows the optimum location of a wet air cleaner in the livestock house.

Transparent Oxide Thin Film Transistors with Transparent ZTO Channel and ZTO/Ag/ZTO Source/Drain Electrodes

  • Choi, Yoon-Young;Choi, Kwang-Hyuk;Kim, Han-Ki
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.127-127
    • /
    • 2011
  • We investigate the transparent TFTs using a transparent ZnSnO3 (ZTO)/Ag/ZTO multilayer electrode as S/D electrodes with low resistivity of $3.24{\times}10^{-5}$ ohm-cm, and high transparency of 86.29% in ZTO based TFTs. The Transparent TFTs (TTFTs) are prepared on glass substrate coated 100 nm of ITO thin film. On atomic layer deposited $Al_2\;O_3$, 50 nm ZTO layer is deposited by RF magnetron sputtering through a shadow mask for channel layer using ZTO target with 1 : 1 molar ratio of ZnO : $SnO_2$. The power of 100W, the working pressure of 2mTorr, and the gas flow of Ar 20 sccm during the ZTO deposition. After channel layer deposition, a ZTO (35 nm)/Ag (12 nm)/ZTO(35 nm) multilayer is deposited by DC/RF magnetron sputtering to form transparent S/D electrodes which are patterned through the shadow mask. Devices are annealed in air at 300$^{\circ}C$ for 30 min following ZTO deposition. Using UV/Visible spectrometer, the optical transmittances of the TTFT using ZTO/Ag/ ZTO multilayer electrodes are compared with TFT using Mo electrode. The structural properties of ZTO based TTFT with ZTO/Ag/ZTO multilayer electrodes are analyzed by high resolution transmission electron microscopy (HREM) and X-ray photoelectron spectroscopy (XPS). The transfer and output characterization of ZTO TTFTs are examined by a customized probe station with HP4145B system in are.

  • PDF