• 제목/요약/키워드: Work pressure

검색결과 2,342건 처리시간 0.03초

Limit analysis of rectangular cavity subjected to seepage forces based on Hoek-Brown failure criterion

  • Yang, X.L.;Qin, C.B.
    • Geomechanics and Engineering
    • /
    • 제6권5호
    • /
    • pp.503-515
    • /
    • 2014
  • On the basis of Hoek-Brown failure criterion, a numerical solution for the shape of collapsing block in the rectangular cavity subjected to seepage forces is obtained by upper bound theorem of limit analysis. The seepage forces obtained from the gradient of excess pore pressure distribution are taken as external loadings in the limit analysis, and the pore pressure is easily calculated with pore pressure coefficient. Thus the seepage force is incorporated into the upper bound analysis as a work rate of external force. The upper solution of the shape of collapsing block is derived by virtue of variational calculation. In order to verify the validity of the method proposed in the paper, the result when the pore pressure coefficient equals zero, and only hydrostatic pressure is taken into consideration, is compared with that of previous work. The results show good effectiveness in calculating the collapsing block shape subjected to seepage forces. The influence of parameters on the failure mechanisms is investigated.

원통다관식 열교환기의 쉘측 압력 손실의 연구 (Investigation of Pressure drop on shell side of shell and tube heat exchanger)

  • 이용범;한성건;고재명
    • 동력기계공학회지
    • /
    • 제12권3호
    • /
    • pp.32-37
    • /
    • 2008
  • The present work aims to determine the overall pressure losses in the shell from the point of entry of the fluid to the outlet point of fluid of shell and tube heat exchanger. The main contribution of the present work is concerned with calculating the pressure drop in the interior section and window section. Shell-side flow velocity distributions have been evaluated. We assume that the shell-side fluid is turbulent. The calculation procedure is based upon the Delaware method. Evaluation of pressure drop on the shell side will be helpful for a designer or manufacturer of a heat exchanger.

  • PDF

흰-관 열교환기에서 재료절감 흰의 제습특성 (Dehumidifying Performance of Material-Saving Fin in Fin-tube Heat Exchanger)

  • 강희찬;김무환
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.730-738
    • /
    • 2001
  • This work discusses the pressure droop, heat and mass transfer of the finned-tube heat exchangers having 7 mm tubes and offset strips in dehumidifying applications. It focuses on the fin material saving and the reduction of pressure drop. The experiment was conducted using three times scaled-up models to simulate the performance of the prototype. Eight kinds of fins having different strips and S shape edges were tested. the area density of the strip was a major factor and its shape and the location were secondary factors on the pressure drop, the heat and mass transfer. The reduced-area fin can almost equal the non-reduced fin in the aspect of heat and mass transfer. The strip fins proposed in the present work can considerably reduce both the pressure drop and the fin material for similar thermal load.

  • PDF

Performance predictions and acoustic analysis of the HVAB rotor in hover

  • Mali, Hajar;Benmansour, Kawtar;Elsayed, Omer;Qaissi, Khaoula
    • Advances in aircraft and spacecraft science
    • /
    • 제9권4호
    • /
    • pp.319-333
    • /
    • 2022
  • This work presents a numerical investigation of the aerodynamics and aero acoustics of the HVAB rotor in hover conditions. Two fully turbulent models are employed, the one-equation Spalart-Allmaras model and the two-equation k-ω SST model. Transition effects are investigated as well using the Langtry-Menter γ-Re θt transition transport model. The noise generation and propagation are being investigated using the Ffows-Williams Hawking model for far-field noise and the broadband model for near-field noise. Comparisons with other numerical solvers and with the PSP rotor test data are presented. The results are presented in terms of thrust and power coefficients, the figure of merit, surface pressure distribution, and Sound pressure level. Velocity, pressure, and vortex structures generated by the rotor are also shown in this work. In addition, this work investigates the contribution of different blade regions to the overall noise levels and emphasizes the importance of considering specific areas for future improvements.

Global Left Ventricular Myocardial Work Efficiency in Patients With Severe Rheumatic Mitral Stenosis and Preserved Left Ventricular Ejection Fraction

  • Estu Rudiktyo;Amiliana M Soesanto;Maarten J Cramer;Emir Yonas;Arco J Teske;Bambang B Siswanto;Pieter A Doevendans
    • Journal of Cardiovascular Imaging
    • /
    • 제31권4호
    • /
    • pp.191-199
    • /
    • 2023
  • BACKGROUND: Assessment of left ventricular (LV) function plays a pivotal role in the management of patients with valvular heart disease, including those caused by rheumatic heart disease. Noninvasive LV pressure-strain loop analysis is emerging as a new echocardiographic method to evaluate global LV systolic function, integrating longitudinal strain by speckle-tracking analysis and noninvasively measured blood pressure to estimate myocardial work. The aim of this study was to characterize global LV myocardial work efficiency in patients with severe rheumatic mitral stenosis (MS) with preserved ejection fraction (EF). METHODS: We retrospectively included adult patients with severe rheumatic MS with preserved EF (> 50%) and sinus rhythm. Healthy individuals without structural heart disease were included as a control group. Global LV myocardial work efficiency was estimated with a proprietary algorithm from speckle-tracking strain analyses, as well as noninvasive blood pressure measurements. RESULTS: A total of 45 individuals with isolated severe rheumatic MS with sinus rhythm and 45 healthy individuals were included. In healthy individuals without structural heart disease, the mean global LV myocardial work efficiency was 96% (standard deviation [SD], 2), Compared with healthy individuals, median global LV myocardial work efficiency was significantly worse in MS patients (89%; SD, 4; p < 0.001) although the LVEF was similar. CONCLUSIONS: Individuals with isolated severe rheumatic MS and preserved EF, had global LV myocardial work efficiencies lower than normal controls.

중년의 일, 가족, 여가시간 배분유형과 유형결정요인: 취업한 기혼 남녀를 중심으로 (A Typology of Mid-life Adults' Everyday life : An Analysis of Time Diary)

  • 차승은
    • 대한가정학회지
    • /
    • 제46권1호
    • /
    • pp.103-116
    • /
    • 2008
  • The purpose of this study was to empirically describe the everyday life of middle-aged adults in terms of their time-use activities. From the original '2004 Time dairy' Data, developed by the Korean National Statistical Office (KNOS), 17,684 respondents aged between 35-59 were selected. In order to categorize their activity patterns, work/labour, domestic labour, and spare leisure time were classified according to the action classification system. As a result, four dominant types were found: namely work-leisure, work-oriented, family-oriented, and leisure-oriented activities. Results of multinomial logistic analysis revealed that gender, age, socioeconomic status, job characteristic, and family structure were the major determinants on time-use. Compared with work-leisure, young middle aged women holding a part-time job with less income tended to be involved in a family-centered time use. Dual earners with lower SES status were likely to have work-oriented time schedules. Older men with relatively lower income were more likely to be involved in leisure-oriented activities rather than work-leisure activities. Multitasking behavior was a significant variable in explaining the four different types of time-use. Work-oriented group showed the highest level of time pressure as well as fatigue. Group differences in these measures, however, was not as large as expected.

동절기 수압시험을 대체하는 공기압시험의 적정압력 비교분석에 관한 연구 (Winter to replace the hydraulic test and pneumatic test comparative analysis of study on the optimal pressure)

  • 권영희;황동환;김태길;강경식
    • 대한안전경영과학회지
    • /
    • 제16권2호
    • /
    • pp.211-216
    • /
    • 2014
  • Using a high-rise building water piping after hydrostatic test of the reliability of the leak to be completed if the pressure is maintained until the leak is not commercially available considered. Due to the nature of high-rise buildings and the construction period will take several years from the lower levels of use of the water supply and fire fighting water pipe construction is in progress, the order of which I do most of the first pipe to the construction and more than three years. So kind of riser pipe is complete, install the valve in the basement by installing an automatic pump to maintain a constant pressure after hydrostatic test and after each floor plumbing piping is complete, the progress of the hydrostatic test without undergoing a separate branch pipe the valve is opened automatically when the number of the pressing pressure of the structure. I kind of do and keep working pressure of pipe until the completion of the construction work to keep the damage to human error when it is intended to prepare. In winter, the frost protection and an alternative to drainage water pipe is damaged or deformed, even if unaware of the finishing work to the building, the use of the damage caused by a leak in a after construction of finish work to be expected. Alternative to reduce this damage if the pressure test without fear of freezing to help maintain long-term commercial pressures may be considered.

요통에서의 pressure biofeedback unit(stabilizer)를 사용한 안정화 운동 (The study of stability exercise using pressure biofeedback unit for low back pain)

  • 김국주;공관우;권순오;장용근;황희준;박준기
    • 대한물리치료과학회지
    • /
    • 제19권2호
    • /
    • pp.63-71
    • /
    • 2012
  • Purpose : This study aimed to acquire a basic knowledge about lumbar stability and inquire into exercise approach of pressure biofeedback unit for lumbar stability. Methods : This study was composed with reviewed theory of lumbar stability and several books and articles for exercise using pressure biofeedback unit. Results : The stability of lumbar should work symmetrical with passive, active, control subsystem in neutral zone, and local muscles should be using for stability. Especially, selective using of transverse abdominis work for lumbar stability importantly. The control of using pressure biofeedback unit may important not only examination but treatment. Conclusion : The stability of lumbar need co-contraction of specific local muscle and training for timing as well as using pressure biofeedback unit for accurate control may use for examination and therapedic approach.

  • PDF

초고압수를 이용한 노후한 도수 강관 내 스케일 제거에 대한 실험적 연구 (The Experimental Study of Scale Removal Using Ultra High Water Pressure in the Old Steel Water Pipe)

  • 서태원;김진동;서현원;김태동
    • 상하수도학회지
    • /
    • 제22권4호
    • /
    • pp.405-409
    • /
    • 2008
  • This technical paper is proposing a sound concept in the application of the rehabilitation method of the water supply steel pipe in the large diameter ranged from 1,800mm to 3,500mm. There were conducted the experimental tests for the specimens as well as the real steel pipe of diameter 2,200mm. The water pressure ejected from nozzle tip should be at least 2,500bar to have the satisfied surface profiles required in the design criterion. The most difficult thing is to keep the water pressure at the nozzle tip as 2,500bar during the consecutive work in the interval of the work site more than 1km. It is found that the method suggested in this study is adequate method to meet the specified design criteria. The results of this study provide the useful information how to setup the equipments for the successful work. This method also provides not only the omission of the blasting process but also the effect of the budget reduction.

간호사의 야간교대근무로 인한 혈압의 일중 변동 양상 (The Effect of Shift Work on the Diurnal Rhythm of Blood Pressure in Nurses)

  • 이안생;이상재;김남호
    • 한국직업건강간호학회지
    • /
    • 제18권1호
    • /
    • pp.14-21
    • /
    • 2009
  • Purpose: This study was performed to investigate the effect of shift work on diurnal blood pressure (BP) pattern in nurses. Method: We studied 20 healthy nurses engaged in 3 shift work. 24-hour ambulatory BP monitoring was performed to each nurse two times during the day and night shift. Five nurses were excluded because of inadequate BP measurement. Results: All subjects were female. The mean age was 27.4 years (range: 23-33 years) and mean body mass index was 19.7 Kg/$m^2$ (range: 18.0-21.2 Kg/$m^2$). The changes of systolic BP ($17.8{\pm}9.1$ vs. $13.2{\pm}4.7%$, p=0.031), diastolic BP ($22.3{\pm}8.7$ vs. $17.3{\pm}9.0%$, p=0.061), and heart rate ($25.2{\pm}5.2$ vs. $12.5{\pm}8.7%$, p=0.001) during the sleeping period were decreased after a night shift compared with day shift. The non-dipper group significantly increased from 20% to 40% after a night shift (p=0.018). Conclusion: Working night shift is significantly associated with non-dipper status in nurses.

  • PDF