• 제목/요약/키워드: Work motions

검색결과 240건 처리시간 0.023초

A Study on Spin-Lattice Relaxation of $^{19}$F Spins in Benzotrifluoride: Contributions from Dipole-Dipole Interaction and Spin-Rotation Interaction

  • Hyun Namgoong;Jo Woong Lee
    • Bulletin of the Korean Chemical Society
    • /
    • 제14권1호
    • /
    • pp.91-95
    • /
    • 1993
  • In this work we have studied the spin-lattice relaxation of $^{19}$F spins in benzotrifluoride in our quest for a reliable method of discriminating the contribution due to dipolar relaxation mechanism from that due to spin-rotational mechanism for nuclear spins located on methyl or substituted methyl group in organic molecules. Over the temperature range of 248-268 K the decay of normalized longitudinal magnetization was found to be well described by a two parameter equation of the form R(t) = exp(-st){$\frac{5}{6}$exp(-s$_1$)+$\frac{1}{6}$} which was derived under the assumption that interactions in the A3 spin system are modulated randomly and predominantly by internal rotational motions of -CF_3$ top, and it was shown that the separation of contribution due to dipolar interactions from that due to spin-rotation interaction could be successfully achieved by least-square fitting of observed data to this equation. The results indicate that the spin-rotational contribution is overwhelmingly larger than that of dipolar origin over the given temperature range and becomes more deminating at higher temperature.

Some properties of the Green's function of simplified elastodynamic problems

  • Sanchez-Sesma, Francisco J.;Rodriguez-Castellanos, Alejandro;Perez-Gavilan, Juan J.;Marengo-Mogollon, Humberto;Perez-Rocha, Luis E.;Luzon, Francisco
    • Earthquakes and Structures
    • /
    • 제3권3_4호
    • /
    • pp.507-518
    • /
    • 2012
  • It is now widely accepted that the resulting displacement field within elastic, inhomogeneous, anisotropic solids subjected to equipartitioned, uniform illumination from uncorrelated sources, has intensities that follow diffusion-like equations. Typically, coda waves are invoked to illustrate this concept. These waves arrive later as a consequence of multiple scattering and appear at "the tail" (coda, in Latin) of seismograms and are usually considered an example of diffuse field. It has been demonstrated that the average correlations of motions within a diffuse field, in frequency domain, is proportional to the imaginary part of Green's function tensor. If only one station is available, the average autocorrelation is equal to the average squared amplitudes or the average power spectrum and this gives the Green's function at the source itself. Several works address this point from theoretical and experimental point of view. However, a complete and explicit analytical description is lacking. In this work we study analytically some properties of the Green's function, specifically the imaginary part of Green's function for 2D antiplane problems. This choice is guided by the fact that these scalar problems have a closed analytical solution (Kausel 2006). We assume the diffusiveness of the field and explore its analytical consequences.

A study on the liquefaction risk in seismic design of foundations

  • Ardeshiri-Lajimi, Saeid;Yazdani, Mahmoud;Assadi-Langroudi, Arya
    • Geomechanics and Engineering
    • /
    • 제11권6호
    • /
    • pp.805-820
    • /
    • 2016
  • A fully coupled non-linear effective stress response finite difference (FD) model is built to survey the counter-intuitive recent findings on the reliance of pore water pressure ratio on foundation contact pressure. Two alternative design scenarios for a benchmark problem are explored and contrasted in the light of construction emission rates using the EFFC-DFI methodology. A strain-hardening effective stress plasticity model is adopted to simulate the dynamic loading. A combination of input motions, contact pressure, initial vertical total pressure and distance to foundation centreline are employed, as model variables, to further investigate the control of permanent and variable actions on the residual pore pressure ratio. The model is verified against the Ghosh and Madabhushi high acceleration field test database. The outputs of this work are aimed to improve the current computer-aided seismic foundation design that relies on ground's packing state and consistency. The results confirm that on seismic excitation of shallow foundations, the likelihood of effective stress loss is greater in deeper depths and across free field. For the benchmark problem, adopting a shallow foundation system instead of piled foundation benefitted in a 75% less emission rate, a marked proportion of which is owed to reduced materials and haulage carbon cost.

TMD effectiveness in nonlinear RC structures subjected to near fault earthquakes

  • Domizio, Martin N.;Ambrosini, Daniel;Curadelli, Oscar
    • Smart Structures and Systems
    • /
    • 제24권4호
    • /
    • pp.447-457
    • /
    • 2019
  • The use of Tuned mass dampers (TMD) has proved to be effective in reducing the effects of vibrations caused by wind loads and far-field seismic action. However, its effectiveness in controlling the dynamic response of structures under near-fault earthquakes is still under discussion. In this case, the uncertainty about the TMD performance arises from the short significant duration of near-fault ground motions. In this work, the TMD effectiveness for increasing the safety margin against collapse of structures subjected to near-fault earthquakes is investigated. In order to evaluate the TMD performance in the proposed scenario, the nonlinear dynamic response of two reinforced concrete (RC) frames was analyzed. TMDs with different mass values were added to these structures, and a set of near-fault records with frequency content close to the fundamental frequency of the structure was employed. Through a series of nonlinear dynamic analysis, the minimum amplitude of each seismic record that causes the structural collapse was found. By comparing this value, called collapse acceleration, for the case of the structures with and without TMD, the benefit produced by the addition of the control device was established.

Vehicle-Level Traffic Accident Detection on Vehicle-Mounted Camera Based on Cascade Bi-LSTM

  • Son, Hyeon-Cheol;Kim, Da-Seul;Kim, Sung-Young
    • 한국정보기술학회 영문논문지
    • /
    • 제10권2호
    • /
    • pp.167-175
    • /
    • 2020
  • In this paper, we propose a traffic accident detection on vehicle-mounted camera. In the proposed method, the minimum bounding box coordinates the central coordinates on the bird's eye view and motion vectors of each vehicle object, and ego-motions of the vehicle equipped with dash-cam are extracted from the dash-cam video. By using extracted 4 kinds features as the input of Bi-LSTM (bidirectional LSTM), the accident probability (score) is predicted. To investigate the effect of each input feature on the probability of an accident, we analyze the performance of the detection the case of using a single feature input and the case of using a combination of features as input, respectively. And in these two cases, different detection models are defined and used. Bi-LSTM is used as a cascade, especially when a combination of the features is used as input. The proposed method shows 76.1% precision and 75.6% recall, which is superior to our previous work.

Axial frequency analysis of axially functionally graded Love-Bishop nanorods using surface elasticity theory

  • Nazemnezhad, Reza;Shokrollahi, Hassan
    • Steel and Composite Structures
    • /
    • 제42권5호
    • /
    • pp.699-710
    • /
    • 2022
  • This work presents a comprehensive study on the surface energy effect on the axial frequency analyses of AFGM nanorods in cylindrical coordinates. The AFGM nanorods are considered to be thin, relatively thick, and thick. In thin nanorods, effects of the inertia of lateral motions and the shear stiffness are ignored; in relatively thick nanorods, only the first one is considered; and in thick nanorods, both of them are considered in the kinetic energy and the strain energy of the nanorod, respectively. The surface elasticity theory which includes three surface parameters called surface density, surface stress, and surface Lame constants, is implemented to consider the size effect. The power-law form is considered for variation of the material properties through the axial direction. Hamilton's principle is used to derive the governing equations and boundary conditions. Due to considering the surface stress, the governing equation and boundary condition become inhomogeneous. After homogenization of them using an appropriate change of variable, axial natural frequencies are calculated implementing harmonic differential quadrature (HDQ) method. Comprehensive results including effects of geometric parameters and various material properties are presented for a wide range of boundary condition types. It is believed that this study is a comprehensive one that can help posterities for design and manufacturing of nano-electro-mechanical systems.

동역학 시뮬레이션을 이용한 함재기 견인차량의 주행특성 분석 기법에 관한 연구 (A Study on Analytical Method of Driving Characteristics of Carrier Aircraft Towing Vehicles Using Dynamic Simulation)

  • 오재원;홍사영;홍섭
    • 대한조선학회논문집
    • /
    • 제60권4호
    • /
    • pp.288-295
    • /
    • 2023
  • This paper deals with the dynamic simulation method for analysis of driving characteristics of aircraft and towing vehicles (TUG) on carrier vessel in wave motions. For prompt deployment in a short period of time, optimization of the movement of carrier aircraft becomes a major issue. In this regards, strategy studies using real-time simulation technology and optimal decision-making technologies are being conducted. In the present work, the dynamic characteristics of carrier aircraft and TUG connected by towbar or towbarless mechanism were investigated by means of multi-body dynamics model. Meanwhile, for real-time simulation, Dugoff's model of tire loads calculation was adopted. Through comparative analysis it was confirmed that the similarity of results between the multi-body contact model and the tire load calculation model can be achieved by coefficients tuning.

Microinstabilities at Quasi-Perpendicular Shocks in the High-�� ICM

  • Kim, Sunjung;Ha, Ji-Hoon;Ryu, Dongsu;Kang, Hyesung
    • 천문학회보
    • /
    • 제45권1호
    • /
    • pp.52.2-52.2
    • /
    • 2020
  • At quasi-perpendicular shocks in the high-�� (��=Pgas/Pmag~100) intracluster medium (ICM), various microinstabilities occur by the temperature anisotropies and/or drift motions of plasma. In the downstream, the Alfvén ion cyclotron instability (AIC) due to the ion temperature anisotropy (Ti⊥>Ti║) is triggered by shock-reflected ions, the whistler instability (WI) is driven by the electron temperature anisotropy (Te⊥>Te║) as a consequence of the shock compression of magnetic fields, and the mirror instability is generated due to the ion and/or electron temperature anisotropy. At the shock foot, the modified two stream instability (MTSI) is possibly excited by the cross-field drift between ions and electrons. In the upstream, electron firehose instability (EFI) is driven by the electron temperature anisotropy or the relative drift between incoming and reflected electrons. These microinstabilities play important roles in the particle acceleration in ICM shocks, so understanding of the microinstabilities and the resultant plasma waves is essential. In this study, based on a linear stability analysis, the basic properties of the microinstabilities in ICM shocks and the ion/electron scale fluctuations are described. We then discuss the implication of our work on the electron pre-acceleration in ICM shocks.

  • PDF

Recovery of 3-D Motion from Time-Varying Image Flows

  • Wohn, Kwang-Yun;Jung, Soon-Ki
    • Journal of Electrical Engineering and information Science
    • /
    • 제1권2호
    • /
    • pp.77-86
    • /
    • 1996
  • In this paper we deal with the problem of recovering 3-D motion and structure from a time-varying 2-D velocity vector field. A great deal has been done on this topic, most of which has concentrated on finding necessary and sufficient conditions for there to be a unique 3-D solution corresponding to a given 2-D motion. While previous work provides useful theoretical insight, in most situations the known algorithms have turned out to be too sensitive to be of much practical use. It appears that any robust algorithm must improve the 3-D solutions over time. As a step toward such algorithm, we present a method for recovering 3-D motion and structure from a given time-varying 2-D velocity vector field. The surface of the object in the scene is assumed to be locally planar. It is also assumed that 3-D velocity vectors are piecewise constant over three consecutive frames (or two snapshots of flow field). Our formulation relates 3-D motion and object geometry with the optical flow vector as well as its spatial and temporal derivatives. The linearization parameters, or equivalently, the first-order flow approximation (in space and time) is sufficient to recover rigid body motion and local surface structure from the local instantaneous flow field. We also demonstrate, through a sensitivity analysis carried out for synthetic and natural motions in space, that 3-D motion can be recovered reliably.

  • PDF

Ergonomic Design of Medic Work Table (MWT) for Medical Technologist

  • Choi, Kyeong-Hee;Lee, Sung-Yong;Lee, Jun-Hyub;Kong, Yong-Ku
    • 대한인간공학회지
    • /
    • 제35권6호
    • /
    • pp.595-609
    • /
    • 2016
  • Objective: The purpose of this study was to develop and validate the guidelines for Medic Work Table (MWT) based on the anthropometric data of medical technologists. Background: Users' anthropometric data such as sitting height, sitting elbow height, knee height, and so on are significant factors for designing comfortable and useful furniture. Thus, many guidelines for different types of desks and chairs based on the users' anthropometric data have been suggested to many researchers. However, few researches have been conducted to provide design guidelines for MWT for blood collecting task. Medical technologists often use their upper extremities to perform blood collecting task with high repetitions. These repeated motions could be a critical factor in the prevalence rate of Work-related Musculoskeletal Disorders (WMSDs). Therefore, a study on ergonomic design of MWT would be essential in preventing the WMSDs and improving the quality of the working environment of medical technologists. Method: This study suggested design guidelines for ergonomic MWT by focusing on the heights of the upper side and underside, depths of the inside and outside, and width of MWT through anthropometric studies and literature reviews. Afterwards, a new MWT was made using the suggested design guidelines for this study. Five healthy medical technologists participated to evaluate the original MWT and new MWT. All participants took part in the range of motion (ROM) test, electromyography (EMG) muscle activity test, and usability test to validate the suggested guidelines in this study. EMG signals of related muscles (Flexor Carpi Ulnaris, Extensor Carpi Ulnaris, Deltoid Anterior, and Biceps Branchii) were recorded through the surface electromyography system from both the original MWT and the new MWT. The ROM test of the shoulder and elbow flexion was also assessed using motion sensors. Results: The newly designed MWT showed decreased ROMs of the shoulder and elbow up to 22% and 18% compared to the original MWT. The muscle activities in the new MWT also showed a decrease of 13% in Anterior Deltoid, 6% in Biceps Brachii, 5% in Flexor Carpi Ulnaris, and 8% in Extensor Carpi Ulnaris muscle groups, compared to the original MWT. In the usability test, the satisfaction score of the new MWT was also 56.1% higher than that of the original MWT. Conclusion: This study suggested guidelines for designing MWT and validating the guidelines through qualitative and quantitative analyses. The results of motion analysis, muscle activity, and usability tests demonstrated that the newly designed MWT may lead to less physical stress, less awkward posture, and better physical user interface. Application: The recommended guidelines of the MWT would be helpful information for designing an ergonomic MWT that reduces physical loads and improves the performance of many medical technologists.