• Title/Summary/Keyword: Work Factor

Search Result 3,625, Processing Time 0.048 seconds

Influence of the hydrogen post-annealing on the electrical properties of metal/alumina/silicon-nitride/silicon-oxide/silicon capacitors for flash memories

  • Kim, Hee-Dong;An, Ho-Myoung;Seo, Yu-Jeong;Zhang, Yong-Jie;Kim, Tae-Geun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.122-122
    • /
    • 2008
  • Recently, Metal/Alumina/Silicon-Nitride/Silicon-Oxide/Silicon (MANOS) structures are one of the most attractive candidates to realize vertical scaling of high-density NAND flash memory [1]. However, as ANO layers are miniaturized, negative and positive bias temperature instability (NBTI/PBTI), such as the flat band voltage shift, ${\Delta}V_{FB}$, the interfacial trap density increase, ${\Delta}D_{it}$, the gate leakage current, ${\Delta}I_G$. and the retention characteristics, in MONOS capacitors, becomes an important issue in terms of reliability. It is well known that tunnel oxide degradation is a result of the oxide and interfacial traps generation during FN (Fowler-Nordheim) stress [2]. Because the bias temperature stress causes an increase of both interfacial-traps and fixed oxide charge could be a factor, witch can degrade device reliability during the program and erase operation. However, few studies on NBTI/PBTI have been conducted on improving the reliability of MONOS devices. In this work, we investigate the effect of post-annealing gas on bias temperature instability (BTI), such as the flat band voltage shift, ${\Delta}V_{FB}$, the interfacial trap density shift, ${\Delta}I_G$ retention characteristics, and the gate leakage current characteristics of MANOS capacitors. MANOS samples annealed at $950^{\circ}C$ for 30 s by a rapid thermal process were treated via additional annealing in a furnace, using annealing gases $N_2$ and $N_2-H_2$ (2 % hydrogen and 98 % nitrogen mixture gases) at $450^{\circ}C$ for 30 min. MANOS samples annealed in $N_2-H_2$ ambient had the lowest flat band voltage shift, ${\Delta}V_{FB}$ = 1.09/0.63 V at the program/erase state, and the good retention characteristics, 123/84 mV/decade at the program/erase state more than the sample annealed at $N_2$ ambient.

  • PDF

System Throughput of Cognitive Radio Multi-hop Relay Networks (무선인지 멀티홉 릴레이 네트워크의 시스템 스루풋)

  • Hassan, I.;Rho, Chang-Bae;Song, Ju-Bin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.4
    • /
    • pp.29-39
    • /
    • 2009
  • The need for radio spectrum is recently considered as a huge hurdle towards the rapid development of wireless networks. Large parts of the spectrum are allocated to licensed radio services in proprietary way. However, enormous success of the wireless services and technologies in the unlicensed bands has brought new ideas and innovations. In recent years cognitive radio has gained much attention for solving the spectrum scarcity problem. It changes the way spectrum is regulated so that more efficient spectrum utilization is possible. Multi-hop relay technology on the other hand has intensively been studied in the area of ad hoc and peer-to-peer networks. But in cellular network, only recently the integration of multi-hop capability is considered to enhance the performance significantly. Multi-hop relaying can extend the coverage of the cell to provide high data rate service to a greater distance and in the shadowed regions. Very few papers still exist that combine these methods to maximize the spectrum utilization. Thus we propose a network architecture combining these two technologies in a way to maximize the system throughput. We present the throughput capacity equations for the proposed system model considering various system parameters like utilization factor by the primary users and primary users' transmission radius and through extensive numerical simulations we analyze the significance of work.

Gross Beta Screening and Monitoring Procedure using Urine Bioassay for Radiation Workers of Radioisotope Production Facilities (뇨시료 전베타 분석법을 이용한 동위원소 생산시설 종사자 내부오염 스크리닝 및 감시절차 개발)

  • Yoon, Seokwon;Kim, Mee-Ryeong;Park, Seyoung;Pak, Min-Jeong;Yoo, Jaeryong;Jang, Han-Ki;Ha, Wi-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.2
    • /
    • pp.52-59
    • /
    • 2013
  • The internal contamination screening method using gross beta measurement was performed for radioisotope workers. 24 h and spot urine samples from workers of medical isotope production facilities were collected and measured. Most of the results were similar with the background level of gross beta activity except for a specific worker. Gross beta activity was slightly increased in several hours after finishing work. And the environmental factor of production facilities causing internal contamination were estimated based on screening results. The additional detailed internal dose assessment must be followed after the screening for protection of workers. Moreover, a procedure was established to apply a simple internal contamination assessment for radiation workers.

MINISCREW STABILITY REGARDING DESIGN OF MINISCREW AND THICKNESS OF CORTICAL BONE (교정용 미니스크류의 디자인과 피질골의 두께에 따른 역학적 안정성 평가)

  • Kweon, Young-Sun;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.3
    • /
    • pp.250-259
    • /
    • 2011
  • The aim of this study was to suggest a design for an orthodontic miniscrew which may work most favorably in the thin cortical bone of the adolescent. In this study, orthodontic miniscrews with different diameters, lengths, and body types were manufactured and implanted in two artificial bone samples with different cortical bone thickness. Maximum insertion torque, maximum removal torque, and lateral alteration torque were measured. As a result, the bone quality, body type, diameter, and the length all had their effects on the maximum insertion torque, maximum removal torque, and lateral alteration torque. Cortical bone thickness was the most important factor. In initial stability, conical types showed better results than cylindrical types. Increase in the diameter had favorable effects in achieving mechanical stability. Increase in the length did not have as much influence as the other factors did on the initial stability, but there was a statistically significant difference between screws of 6 mm and 8 mm lengths(p<0.05). In conclusion, the conical type screw with a diameter of 1.8 mm is most favorable in the thin cortical bone of the adolescent. In terms of length, the 8 mm screw is expected to perform better than the 6 mm screw.

Investigating the Au-Cu thick layers Electrodeposition Rate with Pulsed Current by Optimization of the Operation Condition

  • Babaei, Hamid;Khosravi, Morteza;Sovizi, Mohamad Reza;Khorramie, Saeid Abedini
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.172-179
    • /
    • 2020
  • The impact of effective parameters on the electrodeposition rate optimization of Au-Cu alloy at high thicknesses on the silver substrate was investigated in the present study. After ensuring the formation of gold alloy deposits with the desired and standard percentage of gold with the cartage of 18K and other standard karats that should be observed in the manufacturing of the gold and jewelry artifacts, comparing the rate of gold-copper deposition by direct and pulsed current was done. The rate of deposition with pulse current was significantly higher than direct current. In this process, the duty cycle parameter was effectively optimized by the "one factor at a time" method to achieve maximum deposition rate. Particular parameters in this work were direct and pulse current densities, bath temperature, concentration of gold and cyanide ions in electrolyte, pH, agitation and wetting agent additive. Scanning electron microscopy (SEM) and surface chemical analysis system (EDS) were used to study the effect of deposition on the cross-sections of the formed layers. The results revealed that the Au-Cu alloy layer formed with concentrations of 6gr·L-1 Au, 55gr·L-1 Cu, 24 gr·L-1 KCN and 1 ml·L-1 Lauryl dimethyl amine oxide (LDAO) in the 0.6 mA·cm-2 average current density and 30% duty cycle, had 0.841 ㎛·min-1 Which was the highest deposition rate. The use of electrodeposition of pure and alloy gold thick layers as a production method can reduce the use of gold metal in the production of hallow gold artifacts, create sophisticated and unique models, and diversify production by maintaining standard karats, hardness, thickness and mechanical strength. This will not only make the process economical, it will also provide significant added value to the gold artifacts. By pulsating of currents and increasing the duty cycle means reducing the pulse off-time, and if the pulse off-time becomes too short, the electric double layer would not have sufficient growth time, and its thickness decreases. These results show the effect of pulsed current on increasing the electrodeposition rate of Au-Cu alloy confirming the previous studies on the effect of pulsed current on increasing the deposition rate of Au-Cu alloy.

A Highly Linear Self Oscillating Mixer Using Second Harmonic Injection (2차 고조파 주입을 사용한 고 선형성의 자체 발진 혼합기)

  • Kim, Min-Hoe;Cho, Choon-Sik;Lee, Jae-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.6
    • /
    • pp.682-690
    • /
    • 2012
  • In this paper, a highly linear self oscillating mixers(SOM) using second harmonic injections are presented. The H-slot defected ground structure(DGS) is designed as a balanced resonator for oscillation in the proposed SOM. Since the H-slot DGS resonator achieves a high Q factor, it is a suitable structure to provide low phase noise for the oscillator. The single balanced mixer is utilized in this work and it provides good LO-RF isolation since balanced LO signals are suppressed at the RF input port. In order to inject the second harmonic of the IF, we propose two different methods using feedback loops. In the first method, IF achieves a 3.08 dB conversion gain at 226 MHz with input power of -20 dBm at 5 GHz RF input signal. The IF achieves 2 dB conversion gain at 423 MHz with the input power of -20 dBm at 5.2 GHz RF input signal in the second method. The measured IMD3s are 61.8 dB and 65 dB for the each method. These SOMs present improved linearity compared to that without the second harmonic injection because IMD3s are improved by 18. dB and 21 dB for each method.

Green Tea Extract Decreases the Lymphatic Absorption of Trans Fat in Rats (흰쥐에서 녹차추출물의 트랜스 지방 소장 흡수 억제 작용)

  • Kim, Ju-Yeon;Noh, Sang-K.
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.1
    • /
    • pp.73-78
    • /
    • 2012
  • Excessive intake of trans fats is known to be a risk factor for cardiovascular diseases. Previously, we have shown that green tea extract (GTE) lowers the intestinal absorption of lipids and lipid-soluble compounds in rats. This study was conducted to investigate a possible role of GTE on the lymphatic absorption of elaidic acid, a major trans fat in the diet. Adult male Sprague-Dawley rats with lymph duct cannula were infused via an intraduodenal catheter at 3.0 mL/hr for 8 hr with a lipid emulsion containing $180.0{\mu}mol$ elaidic acid, $400.0{\mu}mol$ triolein, $20.7{\mu}mol$ cholesterol, $3.1{\mu}mol$ ${\alpha}$-tocopherol, and $396.0{\mu}mol$ sodium-taurocholate with or without (control) GTE in a 24 mL PBS buffer (pH, 6.4). Simultaneously, lymph was collected hourly for 8 hr via the lymph duct cannula. There was a significant difference in lymph flow by GTE. Also, the lymphatic absorption of elaidic acid for 8 hr was significantly lower in rats infused with GTE than in those not infused with GTE. Similarly, GTE infusion decreased the lymphatic outputs of cholesterol, oleic acid, and phospholipids, compared with the controls. These findings provide clear evidence that GTE has an inhibitory effect on the intestinal absorption of elaidic acid and other lipids. Our work here provides the foundation for further studies to examine and evaluate dietary strategies to ameliorate dietary trans fats from the diet.

Acceleration Test Method for Failure Prediction of the End Cap Contact Region of Sodium Cooled Fast Reactor Fuel Rod (소듐냉각 고속로 연료봉단의 접촉부 손상예측을 위한 가속시험 방법)

  • Kim, Hyung-Kyu;Lee, Young-Ho;Lee, Hyun-Seung;Lee, Kang-Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.5
    • /
    • pp.375-380
    • /
    • 2017
  • This paper reports the results of an acceleration test to predict the contact-induced failure that could occur at the cylinder-to-hole joint for the fuel rod of a sodium-cooled fast reactor (SFR). To incorporate the fuel life of the SFR currently under development at KAERI (around 35,000 h), the acceleration test method of reliability engineering was adopted in this work. A finite element method was used to evaluate the flow-induced vibration frequency and amplitude for the test parameter values. Five specimens were tested. The failure criterion during the life of the SFR fuel was applied. The S-N curve of the HT-9, the material of concern, was used to obtain the acceleration factor. As a result, a test time of 16.5 h was obtained for each specimen. It was concluded that the $B_{0.004}$ life would be guaranteed for the SFR fuel rods with 99% confidence if no failure was observed at any of the contact surfaces of the five specimens.

Fatigue Crack Growth Characteristics of Cold Stretched STS 304 Welded Joint (콜드 스트레칭 STS 304강 용접부의 저온피로균열진전 특성)

  • Lee, Jeong Won;Na, Seong Hyeon;Yoon, Dong Hyun;Kim, Jae Hoon;Kim, Young Kyun;Kim, Ki Dong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.9
    • /
    • pp.809-815
    • /
    • 2017
  • STS 304 steel is used as pressure vessel material, and although it exhibits excellent mechanical characteristics at a low temperature, it is heavier than other materials. To address this issue, a method using cold-stretching techniques for STS 304 can be applied. In this study, a cold-stretching part and welded joint specimen were directly obtained from a cold-stretching pressure vessel manufactured according to ASME code. Fatigue crack propagation tests were carried out at room temperature and $-170^{\circ}C$ using the compliance method for stress ratios of 0.1 and 0.5. The results indicate that crack growth rate of the welded joint is higher than that of the cold-stretching part within the same stress intensity factor range. The outcome of this work is expected to serve as a basis for the development of a cold-stretched STS 304 pressure vessel.

A Study on Influence of Naeil Cheum Deduction System on Job Satisfaction of small and medium-sized enterprises in Daegu and Gyeongbuk region (대구.경북지역 중소기업의 내일채움공제 제도가 직무만족도에 미치는 영향에 관한 연구)

  • Kim, Dae-Gyu;Lim, Sang-Ho
    • Industry Promotion Research
    • /
    • v.2 no.1
    • /
    • pp.39-44
    • /
    • 2017
  • The purpose of this study is to analyze the effect of the Naeil Chaeum deduction system on job satisfaction. The results of the study are summarized as follows. A total of 159 small to medium-sized enterprise workers participated in the deduction for Naeil Chaeum. The data were analyzed using SPSS Statistics 20, which included frequency analysis, factor analysis, reliability analysis, correlation analysis, regression analysis, and post analysis. First, the suitability of the method of the Naeil Chaeum deduction system has the highest positive effect on the job satisfaction. Second, the correlation of job satisfaction after filling in Naeil Chaeum deductions showed that fitness (p <.01, ${\beta}=.307$) and efficiency (p <.01, ${\beta}=.296$) had a significant effect on job satisfaction. Third, the analysis of the difference of job satisfaction according to the academic ability of the workers who were enrolled in Naeil Chaeum deduction system was analyzed that professional college graduates (2.08) were higher than job college graduates (1.99).The purpose of this study is to analyze the impact of the Fill - Down System on the job satisfaction by analyzing the importance of quality of life, job satisfaction, and muscle strength, analyzing the difference according to the demographic characteristics of the workers, And helping to stabilize the work life, and to verify the effectiveness of the study.