• 제목/요약/키워드: Work Environment Monitoring

검색결과 345건 처리시간 0.032초

내진성능평가에 따른 정밀안전진단 및 내진 보수보강 조치의 개선방안 연구 (A study on the improvement plan for precision safety diagnosis and seismic repair and reinforcement measures according to seismic performance evaluation)

  • 김장욱
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.87-88
    • /
    • 2022
  • For an earthquake-safe urban environment, the Republic of Korea conducts seismic performance evaluation in accordance with laws and guidelines to assign safety ratings and implement necessary management measures such as repairs and reinforcements. In the seismic performance evaluation result, structures lacking in preparation for earthquakes are prioritized and classified into measures such as repair, reinforcement, or careful observation to respond to physical risks such as earthquakes. Such repair and reinforcement work is not a one-time thing, but it is necessary to further enhance the effect through continuous follow-up observation. In this study, the location of the vertical and horizontal displacement measuring part of the construction part is displayed so that the post-construction status of the reinforcement construction part can be visually checked by identifying the problems in the process of post-monitoring in 2022 for the maintenance and reinforcement work of local governments' public facilities carried out in 2021. We propose a plan to institutionalize the installation of, inspection tools, and crack gauges at certain locations in the construction department, and to have facility managers periodically inspect and manage them with a smartphone program or the 'Facility Autonomous Safety Inspection' app.

  • PDF

환경유래 식품오염물질의 범부처 통합 저감화 플랫폼 설계 (Design of Integrated Reduction Platform for Food Contaminants Derived from the Environment through Interagency Collaboration in Korea)

  • 고아라;허지영;강영운;강길진;정명섭;이헌주
    • 한국환경보건학회지
    • /
    • 제43권4호
    • /
    • pp.307-313
    • /
    • 2017
  • Objectives: Chemicals derived from various environment media contaminates food across the food supply chain. In Korea, levels of contaminants in food have been sporadically measured by monitoring programs of different government agencies. There is difficulty with data compilation and integrated analysis across media. Therefore, the aim of this study was to propose an overall integrated database and analytical platform design for the 'ECO-FOOD NET (Environmental COntaminant reduction platform for FOOD through an interagency collaboration NETwork)', a tool to support the reduction of environmental contaminants in food. Methods: We developed a new data structure and standardized protocols for the compilation of integrated data. In addition, we conducted subject-oriented logical and physical relational database modeling and created the architecture design of the platform. Results: We established a standardized code system related to exposure media and route, analysis method and food matrix. In addition, we designed the seven software modules of 'About the System', 'Introduction to Interagency Work', 'Media-Chemicals Profiles', 'Method Bank', 'Monitoring Data Base', 'Integrated Media Analysis', and 'Risk-Benefit Analysis'. Conclusions: This study will contribute to decision-making as a tool for executing risk management, such as sustainable reduction policies of contaminants in food.

한국의 지면 오존이 식생에 미치는 영향에 관한 연구 - 아까시나무 조기낙엽 현상과 관련성 검토 예비 연구 - (Effect of Surface Ozone on Vegetation in Korea - Preliminary Study on Early Foliage of Robinia pseudo-acacia -)

  • 조석연
    • 한국대기환경학회지
    • /
    • 제23권1호
    • /
    • pp.29-38
    • /
    • 2007
  • Recently, the tropospheric ozone has gained a global attention for its adverse effect on vegetation as well as its contribution to the global warming. Although a number of studies have been carried out for the urban ozone, the effect of ozone on vegetation is still largely unknown in Korea. The present work aimed at performing the first evaluation of forest damage by ozone using the national air monitoring data from the year 2000 to the year 2005. Moreover, it also explored the relevance of adverse effect of ozone to the recent events on leaf chlorosis of black locust, Robinia pseudo-acacia, leading to early foliage widely observed in Korea since 2001. In the nineties, forest damages caused by ozone such as leaf chlorosis occurred in Europe and North America and led to invoke comprehensive field and laboratory studies. As a result, AOT40, implying the accumulated dose over a threshold 40 ppb, was developed to assess the forest damage by ozone. 19 air monitoring stations were selected across Korea to calculate AOT40 from the year 2000 to the year 2005. The calculated AOT40 generally increased during April and May and reached the maximum after May. The increase of AOT40 diminished substantially from the mid-June as the rainy season started. The calculated AOT40 in the nine rural sites from the year 2002 to th ε year 2005 ranged from 6.8 to 29.4 ppm-hr. And all the AOT40 at th ε year 2005 exceeded the critical value of 10 ppm-hr for forest damage. Morevoer the calculated AOT40 of Korea appeared higher than the AOT40 of Europe in the year 2004/2005 and comparable to the AOT40 of China in the year 2000. Despite the high levels of the calculated AOT40 since the year 2001 and the consistency of time of seasons between high AOT40 values and occurrence of chlorosis of black locust, further studies are required to conclude that the chlorosis of black locust occurred from the year 2001 to the year 2005 were resulted from a damage by ozone.

상관관계 기반 신호 분류를 이용한 비정상 호흡 상태 모니터링 시스템 (Cross Correlation based Signal Classification for Monitoring System of Abnormal Respiratory Status)

  • 이덕우
    • 한국산학기술학회논문지
    • /
    • 제21권5호
    • /
    • pp.7-13
    • /
    • 2020
  • 본 논문에서는 사람의 비정상적인 호흡과 정상적인 호흡 신호를 획득한 후, 이 신호들을 분석하고, 특히 비정상 호흡신호를 감지하는 방법과 정상 및 비정상 신호를 분류하는 방법을 제시한다. 본 연구에서 사람의 호흡신호는 BIOPAC 장비를 활용하여 획득하며, 사람의 호흡 상태를 정량적인 수치 정보를 활용하여 판단한다. 궁극적으로 본 논문에서는 일반 환경에서 사람의 호흡상태를 신호로 획득하여 분석하고, 호흡상태를 모니터링 할 수 있는 시스템을 개발하고자 하며, 무호흡 상태를 감지 할 수 있는 방법을 제안한다. 획득되는 호흡신호를 활용하여 정량적인 정보를 바탕으로 호흡신호를 상태에 따라 분류한다. 접촉식 의료장비를 활용하여 호흡신호를 획득하고 호흡상태를 분류하기 전에 잡음제거 알고리즘을 적용한다. 기존의 사비츠키-골레이 필터와 중간값 필터의 장점만을 활용하여 혼합필터를 사용하여 신호를 분석하기에 적절한 상태가 되도록 한다. 서로 다른 호흡 상태, 즉 서로 다른 클래스간 거리는 최대로 하고, 동일한 호흡상태, 즉 같은 클래스 간의 거리는 최소로 하기 위해 신호 획득후 신호의 특징값들 간의 상호상관 계수를 계산한다. 제안하는 알고리즘은 실제 호흡 환경에 적용할 수 있을 정도로 직관적이고, 제안하는 방법을 증명하기 위한 실험 결과들을 함께 제시한다.

보건의료시설의 실내 예상 평균 온열감(PMV), 이산화탄소 농도, 소음도, 조도의 통합실내쾌적도(IEQh)를 통한 연간 실내 쾌적도 평가 (Evaluation of Annual Indoor Environment Quality in Hospitals using Various Comfort-related Factors)

  • 이보람;이대엽;반현경;이세원;김규상;이기영
    • 한국환경보건학회지
    • /
    • 제43권3호
    • /
    • pp.214-222
    • /
    • 2017
  • Objectives: A hospital is a complex building that serves many different purposes. The indoor environment in a hospital plays a major role in patient well-being and the work efficiency of the hospital staff. This study was conducted to evaluate overall comfort in two major hospitals over the course of one year. Methods: Various indoor environmental conditions were measured in two general hospitals for one year (April 2014 to April 2015). Monitoring alternated between the hospitals at one month per respective monitoring session. The indoor air temperature, relative humidity (RH), mean radiant temperature and air velocity were measured in order to calculate the predicted mean vote (PMV). Carbon dioxide concentration, noise level and illumination level were concurrently measured and applied to the overall IEQ acceptance model for the hospitals (IEQh). Results: The IEQh at the two general hospitals was different at five spaces within a building. The IEQh for summer and winter were significantly different. Real-time IEQh demonstrated that indoor comfort was affected by the hospital's operating hours due to operation of the HVAC system. The percentage of indoor comfort in the hospitals was higher using PMV than IEQh. Conclusion: IEQh in the hospitals was different at locations with different purposes. Indoor comfort assessment using IEQh was stricter than with PMV. Additional research is needed in order to optimize the IEQh model.

Economic application of structural health monitoring and internet of things in efficiency of building information modeling

  • Cao, Yan;Miraba, Sepideh;Rafiei, Shervin;Ghabussi, Aria;Bokaei, Fateme;Baharom, Shahrizan;Haramipour, Pedram;Assilzadeh, Hamid
    • Smart Structures and Systems
    • /
    • 제26권5호
    • /
    • pp.559-573
    • /
    • 2020
  • One of the powerful data management tools is Building Information Modeling (BIM) which operates through obtaining, recalling, sharing, sorting and sorting data and supplying a digital environment of them. Employing SHM, a BIM in monitoring systems, would be an efficient method to address their data management problems and consequently optimize the economic aspects of buildings. The recording of SHM data is an effective way for engineers, facility managers and owners which make the BIM dynamic through the provision of updated information regarding the occurring state and health of different sections of the building. On the other hand, digital transformation is a continuous challenge in construction. In a cloud-based BIM platform, environmental and localization data are integrated which shape the Internet-of-Things (IoT) method. In order to improve work productivity, living comfort, and entertainment, the IoT has been growingly utilized in several products (such as wearables, smart homes). However, investigations confronting the integration of these two technologies (BIM and IoT) remain inadequate and solely focus upon the automatic transmission of sensor information to BIM models. Therefore, in this composition, the use of BIM based on SHM and IOT is reviewed and the economic application is considered.

Releasing a Genetically Engineered Microorganism for Bioremediation

  • Sayler, Gary;Burlage, Robert;Cox, Chris;Nivens, David;Ripp, Steven;Ahn, Yeonghee;Easter, Jim;Wrner, Claudia;Jarrell, John
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 추계학술대회
    • /
    • pp.153-162
    • /
    • 2000
  • A field study was performed to test effectiveness of a bloluminescent genetically engineered microorganism (GEM) for bioremediation process monitoring and control. The study employed Pseudomonas fluorescens HK44 that was the first strain approved for field application in the U.S. for bioremediation purposes. HK44 contains lux gene fused within a naphthalene degradative pathway, allowing this GEM to bioluminesce as it degrades naphthalene as well as substituted naphthalenes and other polycyclic aromatic hydrocarbons (PAHs) , Results showed that HK44 was maintained in both PAH-contarninated and uncontaminated soils even 660 days after inoculation. HK44 was able to produce bioluminescence in response to PAHs in soil. Although effectiveness of chemical remediation was not assessed due to heterogeneous distribution of contaminants, decreased concentration of naphthalene was shown in the soils, Taken together, HK44 was useful for in situ bioremediation process monitoring and control. This work is so far the only field release of a GEM for bioremediation purposes.

  • PDF

다변량분석법을 이용한 금강 유역의 수질오염특성 연구 (Evaluation of the Geum River by Multivariate Analysis: Principal Component Analysis and Factor Analysis)

  • 김미아;이재관;조경덕
    • 한국물환경학회지
    • /
    • 제23권1호
    • /
    • pp.161-168
    • /
    • 2007
  • The main aim of this work is focus on the Geum river water quality evaluation of pollution data obtained by monitoring measurement during the period 2001-2005. The complex data matrix 19 (entire monitoring stations)*13 (parameters), 60 (month)*13 (parameters) and 20 (season)*13 (parameters) were treated with different multivariate techniques such as factor analysis/principal component analysis (FA/PCA). FA/PCA identified two factor (19*13) classified pollutant Loading factor (BOD, COD, pH, Cond, T-N, T-P, $NH_3$-N, $NO_3$-N, $PO_4$-P, Chl-a), seasonal factor (water temp, SS) and three Factor (60*13, 20*13) classified pollutant Loading factor (BOD, COD, Cond, T-N, T-P, $NH_3$-N, $NO_3$-N, $PO_4$-P), seasonal factor (water temp, SS) and metabolic factor (Chl-a, pH). Loadings of pollutant factor is potent influence main factor in the Geum river which is explained by loadings of pollutant factor at whole sampling stations (71.16%), month (52.75%) and season (56.57%) of main water quality stations. Result of this study is that pollutant loading factor is affected at Gongju 1, 2, Buyeo 1, 2, Gangkyeong, Yeongi stations by entire stations and entire month (Gongju 1, Cheongwon stations), April, May, July and August (buyeo 1) by month. Also the pollutant Loading factor is season gives an influence in winter (Gongju 1, buyeo 1) from main sampling stations, but Cheongwon characteristic is non-seasonal influenced. This study presents necessity and usefulness of multivariate statistic techniques for evaluation and interpretation of large complex data set with a view to get better information data effective management of water sources.

ICT 센서를 기반한 스마트 안전관리 시스템 (Smart Safety Management System based on ICT Sensor)

  • 이승철;정영수;조민준;전동주;백욱진;김남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 춘계학술대회
    • /
    • pp.542-545
    • /
    • 2022
  • 최근 중대재해의 처벌관련법이 건설 환경에 대한 관심을 끌고 있다. 공사현장의 안전관리를 점검하는 일반적인 방법은 근무자가 직접 그들의 눈으로 현장을 확인하는 것이다. 하지만 이 방식은 근무자의 능력의 한계에 영향을 받을 수밖에 없고, 그 결과 피로와 작업 능률 저하를 일으키게 된다. 이런 이유로, 이는 효율적인 방법이 될 수 없다. 이에 우리는 본 연구를 통해 상기 방법을 보완할 수 있는 효율적인 ICT 안전관리 시스템을 제안하여, 작업환경 및 공사 현장 안전에 도움 주고자 한다. 본 논문은 RFID를 활용한 출입 관리 시스템 설계와 소음 센서 및 미세 먼지 센서를 통한 현장 정보 모니터링 방식을 설명한다. 또한, PIR 센서로 중장비와 사람 간의 사고를 예방하고, 자이로 센서를 통해 작업 중인 건물의 기울기를 파악하여 안전사고를 예방할 수 있는 시스템을 제안한다.

  • PDF

Influence of operation of thermal and fast reactors of the Beloyarsk NPP on the radioecological situation in the cooling pond: Part II, Macrophytes and fish

  • Aleksei Panov ;Alexander Trapeznikov;Vera Trapeznikova ;Alexander Korzhavin
    • Nuclear Engineering and Technology
    • /
    • 제55권2호
    • /
    • pp.707-716
    • /
    • 2023
  • The influence of waste technological waters of thermal and fast reactors of Beloyarsk NPP (Russia) on the accumulation of 60Co, 90Sr and 137Cs in macrophytes and ichthyofauna of the cooling pond has been studied. Critical radionuclides, routes of their entry into the ecosystem and periods of maximum discharge of radioisotopes into the cooling pond have been determined. It is shown that the technology of electricity generation at the Beloyarsk NPP, based on fast reactors, has a much smaller effect on the release of artificial radionuclides into the environment. Therefore, during the entire period of monitoring studies (1976-2019), the decrease in the specific activity of radionuclides of NPP origin in macrophytes was 13-25800 times, in ichthyofauna 1.5-44.5 times. The maximum discharge of artificial radionuclides into the Beloyarsk reservoir was noted during the period of restoration and decontamination work aimed at eliminating the emergencies at the AMB reactors of NPP. The factors influencing the accumulation of artificial radionuclides in the components of the freshwater ecosystem of the Beloyarsk cooling pond have been determined, including: the physicochemical nature of radioisotopes, their concentration in surface water, the temperature of the aquatic environment, the trophicity of the reservoir, the species of hydrobionts.