• Title/Summary/Keyword: Withstand voltage test

Search Result 76, Processing Time 0.028 seconds

The Properties of Breakdown and Test for Resistance to Cracking of Power Cable for PL Countermeasure (PL법 대응을 위한 전력케이블의 열 충격 및 절연파괴 특성)

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Sun-Gu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.349-352
    • /
    • 2007
  • It is impossible to database(DB) the patterns of cable events and cause analysis of faulted cable because the product liability(PL) law have been enforced in Korea, since 2002. In additions, simulation and pattern of cable events are needed for DB system under accelerated deterioration. In this paper, we tested for resistance to nicking of cable below the 22.9kV class due to thermal stresses. This method of exam is following IEC 60811-3-1(Common test methods for insulating and sheathing materials of electric cables). First of all, set the cable in the thermal stress instrument, temperature changed from -20 degree to 120 degree. After thermal stress, we observed a surface crack of cable through microscope and carried out AC withstand voltage test.

  • PDF

Reliability Assessment of Forest Fire on Transmission Lines Polymer Insulator(I) (송전용 폴리머 애자의 산불영향 신뢰성 평가(I))

  • Choi, In-Hyuk;Lee, Il-Dong;Jeon, Young-Joon;Lee, Chul-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.425-428
    • /
    • 2004
  • 65% of the Korean peninsula is composed of mountainous area, 97% of which is composed of forest. Therefore, there is high possibility of mountain fire because a lot of potential inflammables such as fallen leaves are stacked on the ground. Moreover, most of the overhead transmission lines in Korea are operated on the mountain. However, there has been very little study for the effect of mountain fire on polymeric insulator for transmission line, though the study is significantly required Therefore, in this study the authors observed the deformation of the housing of the insulator under fire with respect to the ignition time, using artificial ignition testing equipment, and investigated electrical and mechanical characteristics of the insulator by dry withstand voltage test, impulse flashover test and tensile load test.

  • PDF

Properties of double-layered anodizing films on Al alloys formed by two consecutive anodizings (알루미늄 합금의 연속식 양극산화법으로 형성시킨 이중 산화막층의 특성)

  • Jeong, Nagyeom;Choi, Jinsub
    • Journal of the Korean institute of surface engineering
    • /
    • v.54 no.1
    • /
    • pp.30-36
    • /
    • 2021
  • In this study, double-layered anodizing films were formed on Al 5052 and Al 6061 alloys consecutively first in sulfuric acid and then in oxalic acid, and hardness, withstand voltage, surface roughness and acid resistance of the anodizing films were compared with single-layered anodizing films in sulfuric acid and oxalic acid electrolytes. Hardness of the double-layered anodizing film decreased with increasing ratio of inner layer to outer layer for both Al 5052 and Al 6061 alloys, suggesting that outer anodizing film formed in sulfuric acid electrolyte is damaged during the second anodizing in oxalic acid electrolyte. Withstand voltage of the double-layered anodizing films increased with increasing the thickness ratio of inner layer to outer layer. Surface roughness of the double-layered anodizing films were comparable with that of single-layered anodizing film formed in sulfuric acid but higher than that of single layer anodizing film formed in oxalic acid electrolyte. In acid resistance test, all of the double-layered and single-layered anodizing films showed good acid resistance more than 3 h without any visible gas evolution, which is attributable to sealing of pores. Based on the experimental results obtained in this work, it is possible to design a double-layered anodizing film with cost-effectiveness and improved physical and electrical properties by combining two consecutive anodizing processes of sulfuric acid anodizing and oxalic acid anodizing methods.

Insulation Test for the 22.9 kV Class HTS Power Transmission Cable

  • J.W. Cho;Kim, H.J.;K.C. Seong;H.M. Jang;Kim, D.W.;Kim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.3
    • /
    • pp.48-51
    • /
    • 2003
  • HTS power transmission cable is expected to transport large electric power with a compact size. We are developing a 3-core, 22.9 kV, 50 MVA class HTS power cable, and each core consists of a conductor and shield wound with Bi-2223 tapes, electrical insulation with laminated polypropylene paper (LPP) impregnated with liquid nitrogen. This paper describes the design and experimental results of the model cable for the 22.9 kV, 50 MVA class HTS power transmission cable. The model cable was used the SUS tapes instead of HTS tapes because of testing the electrical characteristics only. The model cable was 1.3 m long and electrical insulation thickness was 4.5 mm. The model cable was evaluated the partial discharge (PD), AC and Impulse withstand voltage in liquid nitrogen. The AC and Impulse withstands voltage and PD inception stress was satisfied with the standard of Korea Electric Power Corporation (KEPCO) in the test results. The 3-core 22.9 kV, 50 MVA class HTS power cable has been designed and manufactured based on these experimental results.

Electrical Properties of XLPE Cable Termination using Thermal Contraction Type (열수축형을 이용한 XLPE케이블 종단부의 전기적 특성)

  • Baek, Seung-Myeong;Choi, Jae-Hyeong;Choi, Jin-Wook;Kim, Sang-Hyun;Kim, Yeong-Seok;Kim, Seon-Gu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.395-396
    • /
    • 2009
  • For investigation of electrical properties of XLPE cable termination, we prepared a thermal contraction type kit and 6.6kV XLPE cable. The cable termination that have simulated defect by badness construction have been manufactured and their insulation characteristics such as ac and impulse withstand test have been measured. The influence of defects such as thickness decrease and heating time have been studied. When thickness decreased 1mm, the decreased of AC breakdown voltage value is not very distinctive. However, when thickness decreased 2mm, the insulation AC breakdown voltage value was very low down to 43kV. When approved heat for 300s than 60s, AC Breakdown voltage value appeared high. And also, after insulation breakdown took place, the sample was observed before and after disassembly, and the insulation breakdown hole was observed by means of optical microscope.

  • PDF

The Characteristic on Energy Capability of Varistor fabricated with ZnO Nano-powder (ZnO 나노파우더로 제작한 Bi계 바리스터의 에너지내량 특성)

  • Wang, Min-Sung;Jeong, Jong-Yub;Song, Min-Jong;Park, Choon-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.294-295
    • /
    • 2006
  • Varistor fabricated with ZnO nano-powder was studied about the characteristic of energy capability in this paper. ZnO nano-powder varistor were sintered in air at $1050\;^{\circ}C$. The electrical properties and residual voltage of ZnO nano-powder varistor were obtained. Our ZnO nano-powder varistor has about 3 times of electric field at varistor voltage as compared with commercial ZnO varistor fabricated with micro-powder. In the current impulse withstand test, our nano varistor has had better performance than micro varistor. To analysis energy capability take infrared images for pyrexia distribution of each varistor. ZnO Nano-powder varistor has shown much quick response property because of increasing effective cross-section.

  • PDF

Reliability Verification of Battery Disconnecting Unit (BDU 신뢰성 검증)

  • Yoon, Hye-Lim;Ryu, Haeng-Soo;Ji-Hong;Hong-Tae, Park
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.866-867
    • /
    • 2011
  • As part of the green growth, The Green Car has attracted wide attention. Types of the Green Car are Electric Vehicle, Plug-in Hybrid Electric Vehicle, Hybrid Electric Vehicle, Fuel Cell Vehicle and Clean Diesel Vehicle. Of these, The electric vehicle is equipped with the BDU(Battery Disconnecting Unit). BDU is supplying stable battery power and blocking it to protect electrical system of the electric vehicle. The BDU consists of electric components such as current sensor, fuse and pre-charge resistor. These must pass Voltage withstand test, Salt mist test, Thermal shock test, Vibration test and Short-circuit test commonly to verify reliability of the electric components. In addition, The current sensor should be verified whether normal operation. The breaking capacity of fuse should be verified. The durability of pre-charge resistor should be verified by supplying battery power and blocking it repeatedly. The reliability of BDU as well as the electric vehicle is secured by verifying the reliability of electric components. In addition, It will contribute to the acceleration and promotion of Green Car Technology.

  • PDF

Influence of Defects on Electrical Characteristics of Distributing Cable Termination (배전급 케이블 종단부의 결점이 전기적 특성에 미치는 영향)

  • Kim, Sang-Hyun;Choi, Jae-Hyeong;Choi, Jin-Wook;Kim, Young-Seok;Kim, Sun-Gu;Baek, Seung-Myeong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.190-195
    • /
    • 2009
  • This paper introduces experimental investigates of an electrical accident of the distributing cable termination with simulated a shoddy construction. We prepared two termination kites, one is built-in type, the other is heat contraction type. Also, we manufactured cable termination that have simulated defect by badness construction and investigated their insulation characteristics such as ac (35[kV], 1[min]) and impulse (95[kV], $1.2{\times}50[{\mu}s]$) withstand test. The influence of defects such as thickness decrease, the gap between stress-con of housing and semiconductor and heating time on insulating properties of the termination have been studied. The thickness decrease of an insulator decreases ac breakdown strength suddenly and the breakdown traces of the insulator that is damaged by knife displayed elliptic shape. The gap of between stress-con and semiconductor deteriorates dielectric strength of insulator seriously. In heat contraction type, the ac breakdown voltage became low when the heating time is short.

Insulation Design and Test of Model Windings for the Development of High Temperature Superconducting Transformer (고온초전도변압기 개발을 위한 모델 권선의 절연 설계 및 평가)

  • Joung, Jong-Man;Baek, Sung-Myeong;Kwak, Dong-Sun;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.19-22
    • /
    • 2003
  • In the response to increasing the demands for electrical energy, much effort aimed to develop and commercialize 1MVA HTS power equipments that is supported by a grant from center for Applied Superconductivity Technology of the 21st Century Frontier R&D Program funded by the Ministry of Science and Technology is going on in Korea. For the development, the cryogenic insulation and winding insulation of it in this paper are discussed. In the first many types of dielectric insulating tests were carried out. In detail Breakdown characteristics of $LN_2$, FRP and turn insulating films, flashover characteristics along the FRP surface in $LN_2$ were verified after distinguishing insulation components in HIS windings. And then model windings were designed and insulation test was conducted. These included a AC withstand voltage test of 50kV rms and a lightning impulse test of 150kV at peak.

  • PDF

Evaluation on the Lightning Breakdown Voltages of Palm Oil and Coconut Oil under Non-Uniform Field at Small Gap Distances

  • Thien, Yee Von;Azis, Norhafiz;Jasni, Jasronita;Kadir, Mohd Zainal Abidin Ab;Yunus, Robiah;Ishak, Mohd Taufiq;Yaakub, Zaini
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.184-191
    • /
    • 2016
  • In recent years, there are a number of studies that have been carried out to explore the alternative for Mineral Oil (MO) as dielectric insulating fluid in transformers due to the increasing tight regulation on safety and environment. Vegetable oils have been identified as suitable candidate since it is biodegradable, non-toxic and high flash/fire points which ensure more in-service safety. Among the types of vegetable oils considered for transformers application are Palm Oil (PO) and Coconut Oil (CO). This paper presents an experimental study on the lightning breakdown voltages of PO and CO under non-uniform electric field based on needle-sphere electrodes configuration at 3 small gap distances. The type of PO used in this study is Refined Bleached and Deodorized Palm Oil (RBDPO) Olein. The main focus of this study is to examine the lightning breakdown performance of RBDPO and CO under different test conditions and assess its suitability as dielectric insulating fluid in transformers. The effect of voltage polarities (positive and negative) and testing methods (rising-voltage, up-and-down and multiple-voltage) were investigated. The data obtained from all tests were analysed by Weibull distribution in order to determine the withstand voltages for each type of oils. It was found that the breakdown voltages of RBDPO and CO are comparable with MO under positive lightning impulse. Under negative lightning impulse, the breakdown voltage of MO is slightly higher than RBDPO and CO. There is no significant effect of testing methods and voltage polarities on lightning breakdown voltages of RBDPO and CO. Based on the statistical analysis, it is found that the breakdown voltages of RBDPO and CO at 1% probability are slightly lower than MO.